At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the p...At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the parameters that tension sensors and angle sensors on suspended points detect, and combines with the parameters of the wire itself, and also considers the deflection angel of wires due to wind. In this model, mechanics parameters of wires are turned into the new coordinate plane after deflection angel of wires due to wind, or windage yaw plane. A statics tension balance equation is built in the vertical direction of the new windage yaw plane. According to the theoretical analysis and algorithm, we verify the accuracy of this newly developed mechanical calculation model.展开更多
Ice shedding problems have severely threatened the safety of overhead transmission lines and caused enormous ruptures or failures of the conductors and their accessories.It is of great importance to study the dynamic ...Ice shedding problems have severely threatened the safety of overhead transmission lines and caused enormous ruptures or failures of the conductors and their accessories.It is of great importance to study the dynamic properties of the transmission lines under ice shedding loads.To perform such analysis,the dynamic behavior of two typical strain sections for UHVDC transmission lines under different ice shedding conditions were simulated in this paper.Then,the dynamic response of the key tension plate as well as its buckling properties was analyzed based on the extacted ice shedding results.Finally,laboratory tests were conducted at the China Electric Power Research Institute to assess the critical value of the buckling of the tension plate.The results show that the key tension plate studied in this paper is primarily influenced by the loads along the transmission lines after taking its dynamic response and buckling properties under synthetic ice shedding conditions into consideration.The short-term fluctuation of the tension should be the major focus in tension plate designs.展开更多
This paper presented a method of fabricating radio frequency( RF) transmission lines by embroidering conductive thread on fabric. A digital embroidery machine was selected to fabricate transmission lines. Effects of t...This paper presented a method of fabricating radio frequency( RF) transmission lines by embroidering conductive thread on fabric. A digital embroidery machine was selected to fabricate transmission lines. Effects of the typical process parameters on the S-parameter of these RF transmission lines were tested and discussed. And the results showed that embroidery process parameters such as stitch direction,stitch spacing,stitch length and embroidered tension had significant effects on the RF performance of embroidered transmission lines,of which stitch type was the most important factor for the measured S-parameter of transmission lines.展开更多
文摘At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the parameters that tension sensors and angle sensors on suspended points detect, and combines with the parameters of the wire itself, and also considers the deflection angel of wires due to wind. In this model, mechanics parameters of wires are turned into the new coordinate plane after deflection angel of wires due to wind, or windage yaw plane. A statics tension balance equation is built in the vertical direction of the new windage yaw plane. According to the theoretical analysis and algorithm, we verify the accuracy of this newly developed mechanical calculation model.
基金supported by the Science and Technology Project of the State Grid Corporation of China“Research on Optimization of Typical Tension Insulator String and Quality Improvement of Key Fittings for UHV Transmission Line”(GCB17201900164).
文摘Ice shedding problems have severely threatened the safety of overhead transmission lines and caused enormous ruptures or failures of the conductors and their accessories.It is of great importance to study the dynamic properties of the transmission lines under ice shedding loads.To perform such analysis,the dynamic behavior of two typical strain sections for UHVDC transmission lines under different ice shedding conditions were simulated in this paper.Then,the dynamic response of the key tension plate as well as its buckling properties was analyzed based on the extacted ice shedding results.Finally,laboratory tests were conducted at the China Electric Power Research Institute to assess the critical value of the buckling of the tension plate.The results show that the key tension plate studied in this paper is primarily influenced by the loads along the transmission lines after taking its dynamic response and buckling properties under synthetic ice shedding conditions into consideration.The short-term fluctuation of the tension should be the major focus in tension plate designs.
基金National Natural Science Foundation of China(No.51405079)the Fundamental Research Funds for the Central Universities,China
文摘This paper presented a method of fabricating radio frequency( RF) transmission lines by embroidering conductive thread on fabric. A digital embroidery machine was selected to fabricate transmission lines. Effects of the typical process parameters on the S-parameter of these RF transmission lines were tested and discussed. And the results showed that embroidery process parameters such as stitch direction,stitch spacing,stitch length and embroidered tension had significant effects on the RF performance of embroidered transmission lines,of which stitch type was the most important factor for the measured S-parameter of transmission lines.