期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
CHARACTERISTICS ANALYSIS OF THE INDUCED OVERCURRENT GENERATED BY CLOSE TRIGGERED LIGHTNING ON THE OVERHEAD TRANSMISSION POWER LINE 被引量:8
1
作者 杨少杰 陈绍东 +5 位作者 张义军 董万胜 王建国 周蜜 王孝波 余晖 《Journal of Tropical Meteorology》 SCIE 2010年第1期59-65,共7页
Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightni... Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightning electromagnetic pulses.In this study,using capacitive and resistive dividers,current probes and optical fiber transmission devices,we measured and analyzed the induced overvoltage on the overhead transmission line and the overcurrent through Surge Protective Devices(SPD) when a lightning discharge was artificially triggered nearby on August 12,2008 at Conghua Field Lightning Experiment Site.The triggered lightning discharge contained an initial current stage and eight return strokes whose peak currents ranged from 6.6kA to 26.4kA.We found that overcurrents through SPD were induced on the power line both during the initial continuous current stage and the return stroke processes.During the return strokes,the residual voltage and the current through the SPD lasted up to the ms(millisecond) range,and the overcurrents exhibited a mean waveform up to 22/69μs with a peak value of less than 2kA.Based on the observed data,simple calculations show that the corresponding single discharge energy was much greater than the values of the high voltage pulse generators commonly used in the experiments regulated for SPD.The SPD discharge current peak was not synchronous to that of the residual voltage with the former obviously lagging behind the latter.The SPD discharge current peak was well correlated with the triggered lightning current peak and the wave-front current gradient.The long duration of the SPD current is one of the major reasons why the SPD was damaged even with a big nominal discharge current. 展开更多
关键词 triggered lightning overhead transmission line SPD induced overcurrent
下载PDF
The Development of High Voltage Overhead Transmission Line Technology in China
2
《Electricity》 1999年第1期38-41,共4页
关键词 The Development of High Voltage overhead transmission Line Technology in China
下载PDF
Design of 1000-kV AC Single-Circuit Overhead Transmission Line
3
作者 Li Yongwei1,Yuan Jun2,Zhao Quanjiang3,Cao Yujie4,Chen Haibo21.China Power Engineering Consulting Group Corporation 2.State Grid Corporation of China +1 位作者 3.Central Southern China Electric Power Design Institute 4.North China Electric Power Design Institute Co.Ltd. Wang Xingguo 《Electricity》 2010年第3期38-42,共5页
The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV ov... The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV overhead transmission line in China.Study on key technologies and design schemes shall be carried out to ascertain the technical principles and construction standards for project construction,which are presented in this paper based on the Southeast Shanxi-Nanyang-Jingmen test and demonstration transmission line.A comparison and analysis of technical data and economic indices between UHV line and other lines are also described. 展开更多
关键词 1 000-kV AC transmission test and demonstration project overhead line design
下载PDF
Evaluating transmission towers potentials during ground faults
4
作者 Maria VINTAN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期182-189,共8页
During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper pres... During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper presents analytical methods in order to determine the transmission towers potentials during ground faults,for long and short lines.The author developed a global systematic approach to calculate these voltages,which are dependent of a number of factors.Some of the most important factors are:magnitudes of fault currents,fault location with respect to the line terminals,conductor arrangement on the tower and the location of the faulted phase,the ground resistance of the faulted tower,soil resistivity,number,material and size of ground wires.The effects of these factors on the faulted tower voltages have been also examined for different types of power lines. 展开更多
关键词 overhead transmission lines Ground fault Tower potential
下载PDF
Galloping Vibration Monitoring of Overhead Transmission Lines by Chirped FBG Array 被引量:7
5
作者 Qizhong YAN Ciming ZHOU +3 位作者 Xuebin FENG Chi DENG Wenyu HU Yimin XU 《Photonic Sensors》 SCIE EI CSCD 2022年第3期88-97,共10页
A distributed online fiber sensing system based on the phase-sensitive optical time domain reflectometer(Φ-OTDR)enhanced by the drawing tower fiber Bragg grating(FBG)array is presented and investigated experimentally... A distributed online fiber sensing system based on the phase-sensitive optical time domain reflectometer(Φ-OTDR)enhanced by the drawing tower fiber Bragg grating(FBG)array is presented and investigated experimentally for monitoring the galloping of overhead transmission lines.The chirped FBG array enhanced Φ-OTDR sensing system can be used to measure the galloping behavior of the overhead transmission lines(optical phase conductor or optical power ground wire),which are helpful for monitoring the frequency response characteristics of the ice-induced galloping,evaluating the motion tendencies of these cables,and avoiding the risk of flashover during galloping.The feasibility of the proposed online monitoring system is demonstrated through a series of experiments at the Special Optical Fiber Cable Laboratory of State Grid Corporation of China(Beijing,China).Results show that the proposed system is effective and reliable for the monitoring of galloping shape and characteristic frequency,which can predict the trend of destructive vibration behavior and avoid the occurrence of cable breaking and tower toppling accidents,and these features are essential for the safety operation in smart grids. 展开更多
关键词 Distributed vibration sensing FBG array galloping monitoring overhead transmission lines
原文传递
Hand-eye-vision based control for an inspection robot's autonomous line grasping 被引量:14
6
作者 王伟 吴功平 +6 位作者 白玉成 肖华 杨智勇 严宇 何缘 徐显金 苏帆 《Journal of Central South University》 SCIE EI CAS 2014年第6期2216-2227,共12页
In order to ensure that the off-line arm of a two-arm-wheel combined inspection robot can reliably grasp the line in case of autonomous obstacle crossing,a control method is proposed for line grasping based on hand-ey... In order to ensure that the off-line arm of a two-arm-wheel combined inspection robot can reliably grasp the line in case of autonomous obstacle crossing,a control method is proposed for line grasping based on hand-eye visual servo.On the basis of the transmission line's geometrical characteristics and the camera's imaging principle,a line recognition and extraction method based on structure constraint is designed.The line's intercept and inclination are defined in an imaging space to represent the robot's change of pose and a law governing the pose decoupling servo control is developed.Under the integrated consideration of the influence of light intensity and background change,noise(from the camera itself and electromagnetic field)as well as the robot's kinetic inertia on the robot's imaging quality in the course of motion and the grasping control precision,a servo controller for grasping the line of the robot's off-line arm is designed with the method of fuzzy control.An experiment is conducted on a 1:1 simulation line using an inspection robot and the robot is put into on-line operation on a real overhead transmission line,where the robot can grasp the line within 18 s in the case of autonomous obstacle-crossing.The robot's autonomous line-grasping function is realized without manual intervention and the robot can grasp the line in a precise,reliable and efficient manner,thus the need of actual operation can be satisfied. 展开更多
关键词 inspection robot line grasping control visual servo overhead transmission line autonomous obstacle-crossing
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部