In the modern age, Wireless Body Area Network (WBAN) becomes very popular everywhere for monitoring healthcare services remotely. However, the WBAN system has lagged in efficient power consumption till now. As WBAN is...In the modern age, Wireless Body Area Network (WBAN) becomes very popular everywhere for monitoring healthcare services remotely. However, the WBAN system has lagged in efficient power consumption till now. As WBAN is formed with several portable devices, low power consumption will ensure battery lifetime. In this paper, an analysis of Transmission Power Control (TPC) over WBAN has been conducted. A ZigBee based WBAN model with different network topologies and data rates has been proposed in the experiment. WBAN data-management technique has been proposed due to reducing more data transmission. Less data transmission reduces overall power consumption. The whole work has been done using OPNET and OMNET++ network simulators. Six sensor nodes have been used with a ZigBee coordinator in the simulation scenario where throughput, load, delay, data traffic, amount of power consumption, packet delivery ratio, etc. have been used as simulation parameters. TPC analysis indicates the power consumptions in different topologies, with different data rates. Several simulation scenarios were run and the results were analyzed in this paper.展开更多
Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering ...Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering largescale wind-power transmission.First,the unique voltage characteristics of half-wavelength lines are deduced based on the distributed parameter model.In the secondary voltage-control level,reactive power-transmission limits of half-wavelength lines are introduced as another control objective except for tracing the pilot bus voltage reference.Considering the uncertainty and fluctuation of wind power,the overvoltage risk-assessment method of half-wavelength lines is presented to determine specific voltage-control strategies.Simulation results demonstrate that the proposed voltage-control method delivers superior tracking performance according to a voltage reference value and prevents the overvoltage risk of halfwavelength lines effectively in different wind-power penetrations.展开更多
Date: April 12-15, 2005 Venue: Zhejiang University, Hangzhou, P. R. China Organized by Institute of Mechatronic Control Engineering, Zhejiang University
Power sharing among multiterminal high voltage direct current terminals(MT-HVDC)is mainly developed based on a priority or sequential manners,which uses to prevent the problem of overloading due to a predefined contro...Power sharing among multiterminal high voltage direct current terminals(MT-HVDC)is mainly developed based on a priority or sequential manners,which uses to prevent the problem of overloading due to a predefined controller coefficient.Furthermore,fixed power sharing control also suffers from an inability to identify power availability at a rectification station.There is a need for a controller that ensures an efficient power sharing among the MT-HVDC terminals,prevents the possibility of overloading,and utilizes the available power sharing.A new adaptive wireless control for active power sharing among multiterminal(MT-HVDC)systems,including power availability and power management policy,is proposed in this paper.The proposed control strategy solves these issues and,this proposed controller strategy is a generic method that can be applied for unlimited number of converter stations.The rational of this proposed controller is to increase the system reliability by avoiding the necessity of fast communication links.The test system in this paper consists of four converter stations based on three phase-two AC voltage levels.The proposed control strategy for a multiterminal HVDC system is conducted in the power systems computer aided design/electromagnetic transient design and control(PSCAD/EMTDC)simulation environment.The simulation results significantly show the flexibility and usefulness of the proposed power sharing control provided by the new adaptive wireless method.展开更多
In this paper,the case of a battery charger for electric vehicles based on a wireless power transmission is addressed.The specificity of every stage of the overall system is presented.Based on calculated and measured ...In this paper,the case of a battery charger for electric vehicles based on a wireless power transmission is addressed.The specificity of every stage of the overall system is presented.Based on calculated and measured results,relevant capacitive compensations of the transformer and models are suggested and discussed in order to best match the operating mode and aiming at simplifying as much as possible the control and the electronics of the charger.展开更多
The problem of transmission power control in a rate-aware way is investigated to improve the throughput of wireless ad hoc network. The behavior of basic IEEE 802.11 DCF is approximated by the p-persistent CSMA throug...The problem of transmission power control in a rate-aware way is investigated to improve the throughput of wireless ad hoc network. The behavior of basic IEEE 802.11 DCF is approximated by the p-persistent CSMA through a Markov chain model. The throughput model takes hidden terminals, muhi-hop flow and concurrent interference into account. Numerical results show that the optimal transmission power derived from this model could balance the tradeoff between spatial reuse and data rate and hence yield maximum throughput.展开更多
A unified power flow controller(UPFC)combines the advantages of various flexible alternating current transmission system(FACTS)devices into a powerful format.Using a 500 kV power grid,this study evaluates the selectio...A unified power flow controller(UPFC)combines the advantages of various flexible alternating current transmission system(FACTS)devices into a powerful format.Using a 500 kV power grid,this study evaluates the selection and use of a UPFC to improve transmission capacity.The"UPFC unit capacity control proportionality coefficient"is introduced to quantify the control effect of the UPFC,and an optimal calculation method for the UPFC capacity is presented.Following the proposal of a UPFC site selection process,the data of an existing power grid is used to conduct simulations.The simulation results show that the UPFC has a strong ability to improve transmission capacity,and its use is greatly advantageous.Additionally,by applying the proposed selection method,the control effect and economic benefits of the UPFC can be comprehensively considered during project site selection.These findings have a guiding significance for UPFC site selection in ultra-high voltage power grids.展开更多
Inter-regional transmission line fault often results in power flow transferring, tie-line overloading and system islanding. Traditional control methods such asgenerator tripping and load shedding are costly, and also ...Inter-regional transmission line fault often results in power flow transferring, tie-line overloading and system islanding. Traditional control methods such asgenerator tripping and load shedding are costly, and also have undesirable impacts on theloadside. In this paper, a new emergency power control strategy is proposed for multi-channel interconnected system by using the overload capacity of non-fault DC lines. First of all, the capacity of emergency power control can be acquired by critical transmission power of a certain tie-line for stability. Secondly, the shortest electric distance can be calculated by Dijkstra algorithm, and then the priority of emergency control of the DC lines can be obtained by the entropy weight method. When the inter-regional transmission power decreases and the effect of single DC line emergency control is poor, the multi-channel cooperative emergency control strategy is proposed to ensure the system stability. Simulation results verify the effectiveness of the method proposed.展开更多
Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplie...Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplies have unstable output due to the influence of weather conditions such as wind speed variations, which may cause fluctuations of voltage and frequency in the power system. This paper proposes fuzzy PD based virtual inertia control system to decrease frequency fluctuations in power system caused by fluctuating output of renewable energy sources. The proposed new method is based on the coordinated control of HVDC interconnection line and battery, and energy balancing control is also incorporated in it. Finally, it is concluded that the proposed system is very effective for suppressing the frequency fluctuations of the power system due to the large-scale wind power generation and solar power generation and also for keeping the energy balancing in the HVDC transmission line.展开更多
The access of unified power flow controllers(UPFC)has changed the structure and operation mode of power grids all across the world,and it has brought severe challenges to the traditional real-time calculation of secur...The access of unified power flow controllers(UPFC)has changed the structure and operation mode of power grids all across the world,and it has brought severe challenges to the traditional real-time calculation of security correction based on traditionalmodels.Considering the limitation of computational efficiency regarding complex,physical models,a data-driven power system security correction method with UPFC is,in this paper,proposed.Based on the complex mapping relationship between the operation state data and the security correction strategy,a two-stage deep neural network(DNN)learning framework is proposed,which divides the offline training task of security correction into two stages:in the first stage,the stacked auto-encoder(SAE)classification model is established,and the node correction state(0/1)output based on the fault information;in the second stage,the DNN learningmodel is established,and the correction amount of each action node is obtained based on the action nodes output in the previous stage.In this paper,the UPFC demonstration project of NanjingWest Ring Network is taken as a case study to validate the proposed method.The results show that the proposed method can fully meet the real-time security correction time requirements of power grids,and avoid the inherent defects of the traditional model method without an iterative solution and can also provide reasonable security correction strategies for N-1 and N-2 faults.展开更多
In this paper, we first consider the problem of distributed power control in a Full Duplex (FD) wireless network consisting of multiple pairs of nodes, within which each node needs to communicate with its correspond...In this paper, we first consider the problem of distributed power control in a Full Duplex (FD) wireless network consisting of multiple pairs of nodes, within which each node needs to communicate with its corresponding node. We aim to find the optimal transmition power for the FD transmitters such that the network-wide capacity is maximized. Based on the high Signal-to-Interference-Plus-Noise Ratio (SINR) approximation and a more general approximation method for logarithm functions, we develop effective distributed power control algorithms with the dual decomposition approach. We also extend the work to the general FD network scenario, which can be decomposed into subproblems of isolated nodes, paths, and cycles. The corresponding power control problem is then be solved with the distributed algorithm. The proposed algorithms are validated with simulation studies.展开更多
For offshore hydraulic drive wind turbines,the problems of unsatisfactory speed control and low efficiency at low wind speeds are targeted.A low-speed high-torque radial piston pump is designed to replace the traditio...For offshore hydraulic drive wind turbines,the problems of unsatisfactory speed control and low efficiency at low wind speeds are targeted.A low-speed high-torque radial piston pump is designed to replace the traditional fixed pump with a particular focus on its low-speed performance.The pump is characterized by small internal leakage at low wind speeds and high volumetric efficiency,which is beneficial to improve the power generation efficiency of the system.A new linear control method based on the PID algorithm and feedforward compensation was proposed to obtain the constant speed output control of variable motor at low wind speed.With the model for wind turbine and fixed pump-variable motor main drive system,the system was simulated and experimentally proved to verify the feasibility and anti-interference performance of the system control method at low wind speeds.A promising outcome was obtained on the response characteristics of system power and efficiency at low wind speeds.This can be a powerful technical support for the normal ustility of hydraulic drive wind turbines.展开更多
文摘In the modern age, Wireless Body Area Network (WBAN) becomes very popular everywhere for monitoring healthcare services remotely. However, the WBAN system has lagged in efficient power consumption till now. As WBAN is formed with several portable devices, low power consumption will ensure battery lifetime. In this paper, an analysis of Transmission Power Control (TPC) over WBAN has been conducted. A ZigBee based WBAN model with different network topologies and data rates has been proposed in the experiment. WBAN data-management technique has been proposed due to reducing more data transmission. Less data transmission reduces overall power consumption. The whole work has been done using OPNET and OMNET++ network simulators. Six sensor nodes have been used with a ZigBee coordinator in the simulation scenario where throughput, load, delay, data traffic, amount of power consumption, packet delivery ratio, etc. have been used as simulation parameters. TPC analysis indicates the power consumptions in different topologies, with different data rates. Several simulation scenarios were run and the results were analyzed in this paper.
基金supported by State Grid Corporation of China,Projects under Grant 520626200031National Natural Science Foundation of China,No.51877200。
文摘Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering largescale wind-power transmission.First,the unique voltage characteristics of half-wavelength lines are deduced based on the distributed parameter model.In the secondary voltage-control level,reactive power-transmission limits of half-wavelength lines are introduced as another control objective except for tracing the pilot bus voltage reference.Considering the uncertainty and fluctuation of wind power,the overvoltage risk-assessment method of half-wavelength lines is presented to determine specific voltage-control strategies.Simulation results demonstrate that the proposed voltage-control method delivers superior tracking performance according to a voltage reference value and prevents the overvoltage risk of halfwavelength lines effectively in different wind-power penetrations.
文摘Date: April 12-15, 2005 Venue: Zhejiang University, Hangzhou, P. R. China Organized by Institute of Mechatronic Control Engineering, Zhejiang University
文摘Power sharing among multiterminal high voltage direct current terminals(MT-HVDC)is mainly developed based on a priority or sequential manners,which uses to prevent the problem of overloading due to a predefined controller coefficient.Furthermore,fixed power sharing control also suffers from an inability to identify power availability at a rectification station.There is a need for a controller that ensures an efficient power sharing among the MT-HVDC terminals,prevents the possibility of overloading,and utilizes the available power sharing.A new adaptive wireless control for active power sharing among multiterminal(MT-HVDC)systems,including power availability and power management policy,is proposed in this paper.The proposed control strategy solves these issues and,this proposed controller strategy is a generic method that can be applied for unlimited number of converter stations.The rational of this proposed controller is to increase the system reliability by avoiding the necessity of fast communication links.The test system in this paper consists of four converter stations based on three phase-two AC voltage levels.The proposed control strategy for a multiterminal HVDC system is conducted in the power systems computer aided design/electromagnetic transient design and control(PSCAD/EMTDC)simulation environment.The simulation results significantly show the flexibility and usefulness of the proposed power sharing control provided by the new adaptive wireless method.
文摘In this paper,the case of a battery charger for electric vehicles based on a wireless power transmission is addressed.The specificity of every stage of the overall system is presented.Based on calculated and measured results,relevant capacitive compensations of the transformer and models are suggested and discussed in order to best match the operating mode and aiming at simplifying as much as possible the control and the electronics of the charger.
基金the National High Technology Research and Development Programme of China(No.2004AA104280.2006AA01Z172)
文摘The problem of transmission power control in a rate-aware way is investigated to improve the throughput of wireless ad hoc network. The behavior of basic IEEE 802.11 DCF is approximated by the p-persistent CSMA through a Markov chain model. The throughput model takes hidden terminals, muhi-hop flow and concurrent interference into account. Numerical results show that the optimal transmission power derived from this model could balance the tradeoff between spatial reuse and data rate and hence yield maximum throughput.
基金supported by State Grid Corporation’s Science and Technology Project“Research and Demonstration of Technical Measures for Improving Voltage Supporting Capacity of Large-scale Urban Power Grid”(52094016000Y)
文摘A unified power flow controller(UPFC)combines the advantages of various flexible alternating current transmission system(FACTS)devices into a powerful format.Using a 500 kV power grid,this study evaluates the selection and use of a UPFC to improve transmission capacity.The"UPFC unit capacity control proportionality coefficient"is introduced to quantify the control effect of the UPFC,and an optimal calculation method for the UPFC capacity is presented.Following the proposal of a UPFC site selection process,the data of an existing power grid is used to conduct simulations.The simulation results show that the UPFC has a strong ability to improve transmission capacity,and its use is greatly advantageous.Additionally,by applying the proposed selection method,the control effect and economic benefits of the UPFC can be comprehensively considered during project site selection.These findings have a guiding significance for UPFC site selection in ultra-high voltage power grids.
文摘Inter-regional transmission line fault often results in power flow transferring, tie-line overloading and system islanding. Traditional control methods such asgenerator tripping and load shedding are costly, and also have undesirable impacts on theloadside. In this paper, a new emergency power control strategy is proposed for multi-channel interconnected system by using the overload capacity of non-fault DC lines. First of all, the capacity of emergency power control can be acquired by critical transmission power of a certain tie-line for stability. Secondly, the shortest electric distance can be calculated by Dijkstra algorithm, and then the priority of emergency control of the DC lines can be obtained by the entropy weight method. When the inter-regional transmission power decreases and the effect of single DC line emergency control is poor, the multi-channel cooperative emergency control strategy is proposed to ensure the system stability. Simulation results verify the effectiveness of the method proposed.
文摘Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplies have unstable output due to the influence of weather conditions such as wind speed variations, which may cause fluctuations of voltage and frequency in the power system. This paper proposes fuzzy PD based virtual inertia control system to decrease frequency fluctuations in power system caused by fluctuating output of renewable energy sources. The proposed new method is based on the coordinated control of HVDC interconnection line and battery, and energy balancing control is also incorporated in it. Finally, it is concluded that the proposed system is very effective for suppressing the frequency fluctuations of the power system due to the large-scale wind power generation and solar power generation and also for keeping the energy balancing in the HVDC transmission line.
基金supported in part by Science and Technology Projects of Electric Power Research Institute of State Grid Jiangsu Electric Power Co.,Ltd.(J2021171).
文摘The access of unified power flow controllers(UPFC)has changed the structure and operation mode of power grids all across the world,and it has brought severe challenges to the traditional real-time calculation of security correction based on traditionalmodels.Considering the limitation of computational efficiency regarding complex,physical models,a data-driven power system security correction method with UPFC is,in this paper,proposed.Based on the complex mapping relationship between the operation state data and the security correction strategy,a two-stage deep neural network(DNN)learning framework is proposed,which divides the offline training task of security correction into two stages:in the first stage,the stacked auto-encoder(SAE)classification model is established,and the node correction state(0/1)output based on the fault information;in the second stage,the DNN learningmodel is established,and the correction amount of each action node is obtained based on the action nodes output in the previous stage.In this paper,the UPFC demonstration project of NanjingWest Ring Network is taken as a case study to validate the proposed method.The results show that the proposed method can fully meet the real-time security correction time requirements of power grids,and avoid the inherent defects of the traditional model method without an iterative solution and can also provide reasonable security correction strategies for N-1 and N-2 faults.
基金This paper was presented in part at IEEE WCNC 2015, New Orleans, LA, USA, Mar. 2015 [1]. This work is supported in part by the US National Science Foundation under Grants CNS-1247955, and by the Wireless Engineering Research and Education Center (WEREC) at Auburn University, Auburn, AL, USA.
文摘In this paper, we first consider the problem of distributed power control in a Full Duplex (FD) wireless network consisting of multiple pairs of nodes, within which each node needs to communicate with its corresponding node. We aim to find the optimal transmition power for the FD transmitters such that the network-wide capacity is maximized. Based on the high Signal-to-Interference-Plus-Noise Ratio (SINR) approximation and a more general approximation method for logarithm functions, we develop effective distributed power control algorithms with the dual decomposition approach. We also extend the work to the general FD network scenario, which can be decomposed into subproblems of isolated nodes, paths, and cycles. The corresponding power control problem is then be solved with the distributed algorithm. The proposed algorithms are validated with simulation studies.
基金supported by Chongqing Natural Science Foundation(cstc2019jcyj⁃msxm2000),Chongqing University of Science and Technology Graduate Science and Technology Innovation Project(JXXY201901)。
文摘For offshore hydraulic drive wind turbines,the problems of unsatisfactory speed control and low efficiency at low wind speeds are targeted.A low-speed high-torque radial piston pump is designed to replace the traditional fixed pump with a particular focus on its low-speed performance.The pump is characterized by small internal leakage at low wind speeds and high volumetric efficiency,which is beneficial to improve the power generation efficiency of the system.A new linear control method based on the PID algorithm and feedforward compensation was proposed to obtain the constant speed output control of variable motor at low wind speed.With the model for wind turbine and fixed pump-variable motor main drive system,the system was simulated and experimentally proved to verify the feasibility and anti-interference performance of the system control method at low wind speeds.A promising outcome was obtained on the response characteristics of system power and efficiency at low wind speeds.This can be a powerful technical support for the normal ustility of hydraulic drive wind turbines.