期刊文献+
共找到674篇文章
< 1 2 34 >
每页显示 20 50 100
Application of Shear Wave Elastography and Contrast-Enhanced Ultrasound in Transrectal Prostate Biopsy 被引量:8
1
作者 Gao-wa SHAREN Jun ZHANG 《Current Medical Science》 SCIE CAS 2022年第2期447-452,共6页
Objective To explore the clinical value of ultrasound shear wave elastography(SWE)and contrast-enhanced ultrasound(CEUS)in transrectal prostate biopsy.Methods A total of 54 patients(average age:67.79±12.01 years)... Objective To explore the clinical value of ultrasound shear wave elastography(SWE)and contrast-enhanced ultrasound(CEUS)in transrectal prostate biopsy.Methods A total of 54 patients(average age:67.79±12.01 years)in the experimental group underwent transrectal prostate biopsy under the guidance of SWE,while 46 patients(average age:69.22±11.54 years)in the control group underwent transrectal prostate biopsy guided by CEUS.Results There were a total of 451 needles,with an average of 8.35±1.67 needles per patient in the experimental group,and a total of 462 needles,with an average of 10.04±1.33 needles per patient in the control group.The difference in puncture times between the two groups was statistically significant(P<0.05).There was no significant difference in the positive detection rate,sensitivity or specificity between the two groups(P>0.05),but there was a significant difference in the diagnostic accuracy between the two groups(P<0.05).The E_(mean)and E_(max)of prostate cancer were significantly higher in the experimental group than in benign prostatic hyperplasia(P<0.05).The receiver operating characteristic curve(ROC)analysis showed that the area under the ROC curve(AUC)of E_(mean)was 0.752(S.E.=0.072,95%CI=0.611-0.894,P=0.007),and the best cutoff value was 47.005 kPa.Conclusion In summary,both SWE-and CEUS-guided transrectal prostate biopsy can help find the focus and guide the puncture,and improve the positive detection rate. 展开更多
关键词 prostate puncture ultrasonic shear wave elastography contrast-enhanced ultrasound biopsy analysis
下载PDF
Value of contrast-enhanced ultrasound in deep angiomyxoma using a biplane transrectal probe:A case report 被引量:1
2
作者 Qiong Zhang Hua-Lin Yan +1 位作者 Qiang Lu Yan Luo 《World Journal of Gastroenterology》 SCIE CAS 2023年第26期4214-4221,共8页
BACKGROUND Deep angiomyxoma(DAM)is a very rare tumor type.Magnetic resonance imaging(MRI)is considered the best imaging modality for diagnosing DAM.Computed tomography(CT)is used mainly to assess the invasion range of... BACKGROUND Deep angiomyxoma(DAM)is a very rare tumor type.Magnetic resonance imaging(MRI)is considered the best imaging modality for diagnosing DAM.Computed tomography(CT)is used mainly to assess the invasion range of DAM.The value of ultrasonography in the diagnosis of DAM is still controversial.Through a literature review,we summarized the current state of ultrasonic examination for DAM and reported for the first time the contrast-enhanced ultrasound(CEUS)features of DAM seen using a biplane transrectal probe.CASE SUMMARY A 37-year-old woman presented with a sacrococcygeal mass that had gradually increased in size over the previous 6 mo.MRI and CT examinations failed to allow a definite diagnosis to be made.Transperineal core needle biopsy(CNB)guided by transrectal ultrasound and CEUS was suggested after a multidisciplinary discussion.Grayscale ultrasound of the lesion showed a layered appearance with alternating hyperechoic and hypoechoic patterns.Transrectal CEUS showed a laminated distribution of the contrast agent that was consistent with the layered appearance of the tumor on grayscale ultrasound.We performed transperineal CNB of the enhanced area inside the tumor under transrectal CEUS guidance and finally made a definitive diagnosis of DAM through histopathology.The patient underwent laparoscopic-assisted transabdominal surgery combined with transperineal surgery for large pelvic tumor resection and pelvic floor peritoneal reconstruction.No recurrence or metastasis was found at the ninemonth follow-up.CONCLUSION Transrectal CEUS can show the layered perfusion characteristics of the contrast agent,guiding subsequent transperineal CNB of the enhanced area within the DAM. 展开更多
关键词 contrast-enhanced ultrasound transrectal ultrasound Transperineal core needle biopsy Deep angiomyxoma Pelvic tumor Case report
下载PDF
Contrast-enhanced guided endoscopic ultrasound procedures 被引量:1
3
作者 Marcel Ioan Gheorghiu Andrada Seicean +3 位作者 Cristina Pojoga Claudia Hagiu Radu Seicean Zeno Sparchez 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2311-2320,共10页
Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of t... Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours.Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions,further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS.This review details the knowledge based on the available data on contrast-guided procedures.The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions,which occur in select cases.Additionally,the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage,and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented.Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours,in which case CH-EUS can be used to reveal the incomplete tumour destruction. 展开更多
关键词 ENDOSONOGRAPHY contrast-enhanced endoscopic ultrasound Tissue acquisition Fine needle aspiration Fine needle biopsy Drainage Pancreatic fluid collections BIOPSY PANCREAS
下载PDF
Survival Analysis of Patients Undergoing Intraoperative Contrast-enhanced Ultrasound in the Surgical Treatment of Malignant Glioma
4
作者 Xu CHEN Ya-ni PENG +3 位作者 Fang-ling CHENG Dan CAO An-yu TAO Jian CHEN 《Current Medical Science》 SCIE CAS 2024年第2期399-405,共7页
Objective:Complete resection of malignant gliomas is often challenging.Our previous study indicated that intraoperative contrast-enhanced ultrasound(ICEUS)could aid in the detection of residual tumor remnants and the ... Objective:Complete resection of malignant gliomas is often challenging.Our previous study indicated that intraoperative contrast-enhanced ultrasound(ICEUS)could aid in the detection of residual tumor remnants and the total removal of brain lesions.This study aimed to investigate the survival rates of patients undergoing resection with or without the use of ICEUS and to assess the impact of ICEUS on the prognosis of patients with malignant glioma.Methods:A total of 64 patients diagnosed with malignant glioma(WHO grade HI and IV)who underwent surgery between 2012 and 2018 were included.Among them,29 patients received ICEUS.The effects of ICEUS on overall survival(OS)and progression-free survival(PFS)of patients were evaluated.A quantitative analysis was performed to compare ICEUS parameters between gliomas and the surrounding tissues.Results:The ICEUS group showed better survival rates both in OS and PFS than the control group.The univariate analysis revealed that age,pathology and ICEUS were significant prognostic factors for PFS,with only age being a significant prognostic factor for OS.In multivariate analysis,age and ICEUS were significant prognostic factors for both OS and PFS.The quantitative analysis showed that the intensity and transit time of microbubbles reaching the tumors were significantly different from those of microbubbles reaching the surrounding tissue.Conclusion:ICEUS facilitates the identification of residual tumors.Age and ICEUS are prognostic factors for malignant glioma surgery,and use of ICEUS offers a better prognosis for patients with malignant glioma. 展开更多
关键词 intraoperative contrast-enhanced ultrasound malignant glioma extent of resection SURVIVAL PROGNOSIS
下载PDF
Evaluating the efficacy of percutaneous puncture biopsy guided by contrast-enhanced ultrasound for peripheral pulmonary lesions
5
作者 Xiao Jiang Jun Chen +8 位作者 Fang-Fang Gu Zhong-Rong Li Yu-Shan Song Jing-Jing Long Shu-Zhen Zhang Ting-Ting Xu Yong-Jun Tang Ji-Ying Gu Xiang-Ming Fang 《World Journal of Clinical Cases》 SCIE 2024年第19期3791-3799,共9页
BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for t... BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions. 展开更多
关键词 contrast-enhanced ultrasound Peripheral lung lesions ultrasound guidance BIOPSY Peripheral thoracic focal lesions
下载PDF
Clinical application of oral contrast-enhanced ultrasound in evaluating the preoperative T staging of gastric cancer
6
作者 Yu Liang Wan-Yi Jing +6 位作者 Jun Song Qiu-Xin Wei Zhi-Qing Cai Juan Li Ping Wu Dong Wang Yi Ma 《World Journal of Gastroenterology》 SCIE CAS 2024年第41期4439-4448,共10页
BACKGROUND Oral contrast-enhanced ultrasound(OCEUS)is widely used in the noninvasive diagnosis and screening of gastric cancer(GC)in China.AIM To investigate the clinical application of OCEUS in evaluating the preoper... BACKGROUND Oral contrast-enhanced ultrasound(OCEUS)is widely used in the noninvasive diagnosis and screening of gastric cancer(GC)in China.AIM To investigate the clinical application of OCEUS in evaluating the preoperative T staging of gastric cancer.METHODS OCEUS was performed before the operation,and standard ultrasound images were retained.The depth of infiltration of GC(T-stage)was evaluated according to the American Joint Committee on Cancer 8th edition of the tumor-nodemetastasis staging criteria.Finally,with postoperative pathological staging as the gold standard reference,the sensitivity,specificity,negative predictive value,positive predictive value,and diagnostic value of OCEUS T staging were evaluated.RESULTS OCEUS achieved diagnostic accuracy rates of 76.6%(T1a),69.6%(T1b),62.7%(T2),60.8%(T3),88.0%(T4a),and 88.7%(T4b),with an average of 75.5%.Ultrasonic T staging sensitivity exceeded 62%,aside from T1b at 40.3%,while specificity was over 91%,except for T3 with 83.5%.The Youden index was above 60%,with T1b and T2 being exceptions.OCEUS T staging corresponded closely with pathology in T4b(kappa>0.75)and moderately in T1a,T1b,T2,T3,and T4a(kappa 0.40-0.75),registering a concordance rate exceeding 84%.CONCLUSION OCEUS was effective,reliable,and accurate in diagnosing the preoperative T staging of GC.As a noninvasive diagnostic technique,OCEUS merits clinical popularization. 展开更多
关键词 Gastric cancer Oral contrast-enhanced ultrasound Tumor-node-metastasis staging Noninvasive diagnosis and screening Clinical value
下载PDF
Ultrasomics in liver cancer: Developing a radiomics model for differentiating intrahepatic cholangiocarcinoma from hepatocellular carcinoma using contrast-enhanced ultrasound
7
作者 Li-Ya Su Ming Xu +2 位作者 Yan-Lin Chen Man-Xia Lin Xiao-Yan Xie 《World Journal of Radiology》 2024年第7期247-255,共9页
BACKGROUND Hepatocellular carcinoma(HCC)and intrahepatic cholangiocarcinoma(ICC)represent the predominant histological types of primary liver cancer,comprising over 99%of cases.Given their differing biological behavio... BACKGROUND Hepatocellular carcinoma(HCC)and intrahepatic cholangiocarcinoma(ICC)represent the predominant histological types of primary liver cancer,comprising over 99%of cases.Given their differing biological behaviors,prognoses,and treatment strategies,accurately differentiating between HCC and ICC is crucial for effective clinical management.Radiomics,an emerging image processing technology,can automatically extract various quantitative image features that may elude the human eye.Reports on the application of ultrasound(US)-based radiomics methods in distinguishing HCC from ICC are limited.METHODS In our retrospective study,we included a total of 280 patients who were diagnosed with ICC(n=140)and HCC(n=140)between 1999 and 2019.These patients were divided into training(n=224)and testing(n=56)groups for analysis.US images and relevant clinical characteristics were collected.We utilized the XGBoost method to extract and select radiomics features and further employed a random forest algorithm to establish ultrasomics models.We compared the diagnostic performances of these ultrasomics models with that of radiologists.RESULTS Four distinct ultrasomics models were constructed,with the number of selected features varying between models:13 features for the US model;15 for the contrast-enhanced ultrasound(CEUS)model;13 for the combined US+CEUS model;and 21 for the US+CEUS+clinical data model.The US+CEUS+clinical data model yielded the highest area under the receiver operating characteristic curve(AUC)among all models,achieving an AUC of 0.973 in the validation cohort and 0.971 in the test cohort.This performance exceeded even the most experienced radiologist(AUC=0.964).The AUC for the US+CEUS model(training cohort AUC=0.964,test cohort AUC=0.955)was significantly higher than that of the US model alone(training cohort AUC=0.822,test cohort AUC=0.816).This finding underscored the significant benefit of incorporating CEUS information in accurately distin-guishing ICC from HCC.CONCLUSION We developed a radiomics diagnostic model based on CEUS images capable of quickly distinguishing HCC from ICC,which outperformed experienced radiologists. 展开更多
关键词 CHOLANGIOCARCINOMA Hepatocellular carcinoma contrast-enhanced ultrasound Radiomics Primary liver tumor
下载PDF
Ultrasound,contrast-enhanced ultrasound and pyelonephritis:A narrative review
8
作者 Andrea Boccatonda Roberta Stupia Carla Serra 《World Journal of Nephrology》 2024年第3期1-8,共8页
Acute pyelonephritis(APN)is a bacterial infection resulting in kidney inflammation,typically arising as a complication of an ascending urinary tract infection that ascends from the bladder to the kidneys.Clinical diag... Acute pyelonephritis(APN)is a bacterial infection resulting in kidney inflammation,typically arising as a complication of an ascending urinary tract infection that ascends from the bladder to the kidneys.Clinical diagnosis is generally based on clinical and laboratory findings.Recent guidelines recommend not performing diagnostic imaging unless a complicated APN is suspected or the infection affects high-risk patients such as the elderly,immunocompromised individuals,or diabetics.Contrast-enhanced ultrasound(CEUS)is a valuable tool in both the diagnosis and follow-up of APN.It aids in distinguishing small simple nephritic involvement from abscess complications and monitoring their evolution over time during antibiotic therapy.Given its lack of ionizing radiation and nephrotoxicity,CEUS is a valid diagnostic modality for approaching and monitoring pyelonephritis,improving early identification and characterization of inflammatory lesions.This review aims to summarize the main evidence on the use of ultrasound and CEUS in the diagnosis of APN and its follow-up. 展开更多
关键词 PYELONEPHRITIS contrast-enhanced ultrasound KIDNEY ABSCESS Urinary infection
下载PDF
Comparison of Cognitive Registration Transrectal Ultrasound-Guided Targeted Biopsy of Prostate to Systematic 12-Core Biopsy: A Retrospective, Multicentre Study
9
作者 Kevin Chang Yue Wei Lee Say Bob +4 位作者 Devindran Manoharan Liong Men Long Teoh Sze Yong Teo Rui Ling Chua Zi Wei 《Open Journal of Urology》 2024年第7期381-390,共10页
Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (... Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (TRUS-SB) is the primary diagnostic method, prebiopsy multiparametric magnetic resonance imaging (mpMRI) is gaining popularity in identifying suspicious lesions. This study addresses the lack of comprehensive investigations into the efficacy of cognitive registration TRUS targeted biopsy (COG-TB) compared to conventional TRUS-SB, considering the resource limitations of the Malaysian healthcare system. Materials and Methods: A retrospective cohort study was conducted in two Malaysian healthcare facilities. 116 adult patients with a prostate-specific antigen (PSA) level of more than 4 ng/mL who underwent both COG-TB and TRUS-SB between October 2020 and March 2022 were included. Primary outcomes were cancer detection rate and histopathological outcomes, including Gleason score. Results: COG-TB showed a higher overall cancer detection rate (50%) compared to TRUS-SB (44%). Clinically significant cancer detection rates were similar between COG-TB and TRUS-SB (37.1%). Further analysis revealed that both COG-TB and TRUS-SB detected clinically significant cancer in 30.2% of patients, did not detect it in 56.0%, and had conflicting findings in 16 patients (p Conclusion: COG-TB and TRUS-SB have comparable detection rates for clinically significant prostate cancer, with COG-TB showing a higher tendency to detect insignificant prostate cancer. Further studies comparing these methods are warranted. 展开更多
关键词 Prostate Cancer Multiparametric MRI Targeted Biopsy Cognitive Fusion transrectal ultrasound-Guided Biopsy
下载PDF
Contrast-enhanced ultrasound in the biliary system:Potential uses and indications 被引量:27
10
作者 Hui-Xiong Xu 《World Journal of Radiology》 CAS 2009年第1期37-44,共8页
Conventional ultrasound(US)is the first-line imaging investigation for biliary diseases.However,it is lack of the ability to depict the microcirculation of some lesions which may lead to failure in diagnosis for some ... Conventional ultrasound(US)is the first-line imaging investigation for biliary diseases.However,it is lack of the ability to depict the microcirculation of some lesions which may lead to failure in diagnosis for some biliary diseases.The use of contrast-enhanced US(CEUS)has reached the field of bile duct disease in recent years and promising results have been achieved.In this review,the methodology,image interpretation,enhancement pattern,clinical usefulness,and indications for CEUS in the biliary system are summarized.CEUS may be indicated in the biliary system under the following circumstances:(1)Where there is a need to make a characterization of intrahepatic cholangiocarcinoma(ICC);(2)For differentiation diagnosis between ICC and other tumors(i.e.hepatocellular carcinoma or liver metastasis)or infectious diseases;(3)For differentiation diagnosis between biliary cystadenoma and biliary cystadenocarcinoma;(4)To detect malignant change in Caroli’s disease;(5)To depict the extent of Klatskin’s tumor with greater clarity;(6)To make a distinction between gallbladder cholesterol polyp,adenoma and polypoid cancer;(7)To make a distinction between chronic cholecystitis with thickened wall and gallbladder cancer;(8)For differentiation diagnosis between motionless sludge and gallbladder cancer;(9)For differentiation diagnosis between common bile duct cancer and sludge or stone without acoustic shadowing;and(10)In patients who are suspected of having a drop of their percutaneous transhepatic cholangiodrainage tube,US contrast agent can be administered to through the tube detect the site of the tube. 展开更多
关键词 contrast-enhanced ultrasound BILE duct GALLBLADDER CHOLANGIOCARCINOMA POLYPOID lesion ultrasound contrast agent
下载PDF
Contrast-enhanced ultrasound in differentiating malignant from benign portal vein thrombosis in hepatocellular carcinoma 被引量:19
11
作者 Luciano Tarantino Pasquale Ambrosino Matteo Nicola Dario Di Minno 《World Journal of Gastroenterology》 SCIE CAS 2015年第32期9457-9460,共4页
Portal vein thrombosis(PVT) may occur in liver cirrhosis patients. Malignant PVT is a common complication in cirrhotic patients with concomitant hepatocellular carcinoma(HCC) and, in some cases, it may be even the ini... Portal vein thrombosis(PVT) may occur in liver cirrhosis patients. Malignant PVT is a common complication in cirrhotic patients with concomitant hepatocellular carcinoma(HCC) and, in some cases, it may be even the initial sign of an undetected HCC. Detection of malignant PVT in a patient with liver cirrhosis heavily affects the therapeutic strategy. Gray-scale ultrasound(US) is widely unreliable for differentiating benign and malignant thrombi. Although effective for this differential diagnosis, fine-needle biopsy remains an invasive technique. Sensitivity of color-doppler US in detection of malignant thrombi is highly dependent on the size of the thrombus. Contrast-enhanced computed tomography(CT) and contrast-enhanced magnetic resonance(MRI) can be useful to assess the nature of portal thrombus, while limited data are currently available about the role of positron emission tomography(PET) and PET-CT. In contrast with CT, MRI, PET, and PET-CT, contrast-enhanced ultrasound(CEUS) is a fast, effective, well tolerated and cheap technique, that can be performed even in the same session in which the thrombus has been detected. CEUS can be performed bedside and can be available also in transplanted patients. Moreover, CT and MRI only yield a snapshot analysis during contrast diffusion, while CEUS allows for a continuous real-time imaging of the microcirculation that lasts several minutes, so that the whole arterial phase and the late parenchymal phase of the contrast diffusion can be analyzed continuously by real-time US scanning. Continuous real-time monitoring of contrast diffusion entails an easy detection of thrombus maximum enhancement. Moreover, continuous quantitative analyses of enhancement(wash in- wash out studies) by CEUS during contrast diffusion is nowadays available in most CEUS machines, thus giving a more sophisticated and accurate evaluation of the contrast distribution and an increased confidence in diagnosis in difficult cases. In conclusion, CEUS is avery reliable technique with a high intrinsic sensitivity for portal vein patency assessment. More expensive and sophisticated techniques(i.e., CT, MRI, PET, and PET-CT) should only be indicated in undetermined cases at CEUS. 展开更多
关键词 contrast-enhanced ultrasound HEPATOCELLULAR carcin
下载PDF
The performance of transrectal ultrasound in the diagnosis of seminal vesicle defects: a comparison with magnetic resonance imaging 被引量:6
12
作者 Xu Chen Hua Wang +6 位作者 Rong-Pei Wu Hui Liang Xiao-Peng Mao Cheng-Qiang Mao Hong-Zhang Zhu Shao-Peng Qiu Dao-Hu Wang 《Asian Journal of Andrology》 SCIE CAS CSCD 2014年第6期907-911,共5页
Obstructive azoospermia (OA) is one of the most common causes of male infertility. Transrectal ultrasound (TRUS) has been used to diagnose OA for many years. From 2009 to 2013, we evaluated a prospective cohort of... Obstructive azoospermia (OA) is one of the most common causes of male infertility. Transrectal ultrasound (TRUS) has been used to diagnose OA for many years. From 2009 to 2013, we evaluated a prospective cohort of 1249 patients with suspected OA using TRUS. It was found that dilation of the ejaculatory duct (ED) (29.9%, 374/1249) was the most common cause of OA, followed by seminal vesicle (SV) abnormalities (28.5%, 356/1249). A total of 237 patients were diagnosed with congenital defects (agenesis and/or hypoplasia) of the SV, constituting more than half of the cases of SV disease in OA (19.0%, 237/1249). In contrast to ED, congenital defects of the SV could not be corrected with surgical treatment. Therefore, it is meaningful to compare TRUS and magnetic resonance imaging (MRI) for accurate diagnosis of SV defects. Among our patients, 30 with agenesis or/and hypoplasia of the SV on TRUS were further evaluated using pelvic MRI within 2 years, with the objective of verifying the TRUS results. The concordance rate for diagnosing congenital defects of the SV was 73.3% (22/30). We concluded that TRUS is a reliable and convenient method for diagnosing agenesis or hypoplasia of the SV in OA patients with a high concordance with MRI while MRI is useful in patients with inconclusive TRUS findings. 展开更多
关键词 DEFECTS magnetic resonance imaging obstructive azoospermia seminal vesicle transrectal ultrasound
下载PDF
Value of contrast-enhanced ultrasound combined with elastography in evaluating cervical lymph node metastasis in papillary thyroid carcinoma 被引量:22
13
作者 Wei Jiang Hong-Yan Wei +1 位作者 Hai-Yan Zhang Qiu-Luan Zhuo 《World Journal of Clinical Cases》 SCIE 2019年第1期49-57,共9页
BACKGROUND Cervical lymph node metastasis in papillary thyroid carcinoma(PTC) affects the treatment and prognosis of patients. Ultrasound is a common imaging method for detecting cervical lymph nodes in PTC patients; ... BACKGROUND Cervical lymph node metastasis in papillary thyroid carcinoma(PTC) affects the treatment and prognosis of patients. Ultrasound is a common imaging method for detecting cervical lymph nodes in PTC patients; however, it is not accurate in determining lymph node metastasis.AIM To evaluate the value of contrast-enhanced ultrasound combined with elastography in evaluating cervical lymph node metastasis in PTC.METHODS A total of 94 patients with PTC were recruited. According to pathological results,lymph nodes were divided into two groups: metastatic group(n = 50) and reactive group(n = 63). The routine ultrasound findings, contrast-enhanced ultrasound and elastography data were recorded and compared. Logistic regression was used to generate predictive probability distributions for the diagnosis of lymph node metastasis with different indicators. Receiver operating characteristic curve analysis was used to test the efficacy of contrast-enhanced ultrasound combined with elastography based on routine ultrasound in evaluating PTC cervical lymph node metastasis.RESULTS The ratio of long diameter/short diameter(L/S) ≤ 2, irregular marginal morphology, missing lymphatic portal, peripheral or mixed blood flow distribution, peak intensity(PI), non-uniform contrast distribution and elasticity score in the metastatic group were significantly higher than those in the reactive group(P < 0.05). L/S ratio, missing lymphatic portal, PI and elasticity score had a significant influence on the occurrence of PTC cervical lymph node metastasis(P< 0.05). Furthermore, the area under the curve(AUC) for lymph node metastasis diagnosed using the combination of PI ratio, elasticity score, missing lymphatic portal and LS was 0.936, which was significantly higher than the AUC for PI ratio alone. The difference was statistically significant(P < 0.05). The fitting equation for the combined diagnosis was logit(P) =-12.341 + 1.482 × L/S ratio + 3.529 ×missing lymphatic portal + 0.392 × PI + 3.288 × elasticity score.CONCLUSION Based on the gray-scale ultrasound, the combination of contrast-enhanced ultrasound and elastography can accurately assess PTC cervical lymph node metastasis. 展开更多
关键词 contrast-enhanced ultrasound ELASTOGRAPHY PAPILLARY THYROID cancer CERVICAL LYMPH node metastasis
下载PDF
Contrast-enhanced ultrasound:Improving the preoperative staging of hepatocellular carcinoma and guiding individual treatment 被引量:16
14
作者 Xiao-Yun Zhang Yan Luo +8 位作者 Tian-Fu Wen Li Jiang Chuan Li Xiao-Fei Zhong Jing-Yi Zhang Wen-Wu Ling Lu-Nan Yan Yong Zeng Hong Wu 《World Journal of Gastroenterology》 SCIE CAS 2014年第35期12628-12636,共9页
AIM: To investigate the clinical role of contrast-enhanced ultrasound (CEUS) combined with contrast-enhanced computed tomography (CE-CT) or magnetic resonance imaging to improve the preoperative staging of hepatocellu... AIM: To investigate the clinical role of contrast-enhanced ultrasound (CEUS) combined with contrast-enhanced computed tomography (CE-CT) or magnetic resonance imaging to improve the preoperative staging of hepatocellular carcinoma (HCC) and guide surgical decision-making. METHODS: Sixty-nine patients who underwent liver resection for HCC in our center were enrolled prospectively in the study. CEUS and CE-CT/MRI were performed before surgery. Intraoperative ultrasound (IOUS) was carried out after liver mobilization. Lesions depicted by each imaging modality were counted and mapped. To investigate the impact of tumor size on the study, we divided the patients into two groups, the 'Smaller group'(S-group, <= 5 cm in diameter) and the 'Largergroup' (L-group, > 5 cm in diameter). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CE-CT/MRI, CEUS, IOUS, CEUS+CE-CT/MRI and the tumor node metastasis staging of tumors were calculated and compared. Changes in the surgical strategy as a result of CEUS and IOUS were analyzed. RESULTS: One hundred and twenty-seven nodules, comprising 94 HCCs confirmed by histopathology and 33 benign lesions confirmed by histopathology and follow-up, were identified in 69 patients. The overall diagnostic sensitivity rates of CE-CT/MRI, CEUS, IOUS and CEUS+ CE-CT/MRI were 78.7%, 89.4%, 89.4% and 89.4%, respectively. There was a significant difference between CEUS + CE-CT/MRI and CE-CT/MRI (P = 0.046). Combining CEUS with CT or MRI increased, the diagnostic specificity compared with CT/MRI, CEUS and IOUS, and this difference was statistically significant (100%, 72.7%, 97.0%, and 69.7%, P = 0.004, P = 0.002, P = 0.002, respectively). The diagnostic accuracy was significantly higher for CEUS + CT/MRI compared with CT/MRI (92.1% vs 77.2%, P = 0.001). The TNM staging of tumors based on CEUS + CE-CT/MRI approximated to the final pathological TNM staging (P = 0.977). There was a significant difference in the accuracy of TNM staging when comparing CEUS + CECT/MRI with CE-CT/MRI (P = 0.002). Before surgery, strategies were changed in 15.9% (11/69) of patients as a result of CEUS. Finally, only 5.7% (4/69) of surgical strategies were changed because of IOUS findings. In the S-group, CEUS revealed 12 false positive lesions, including seven false positive lesions that were diagnosed by preoperative imaging examinations and five by IOUS. In contrast, in the L-group, IUOS revealed eight new malignant lesions; six of these lesions were true HCCs that were also identified by preoperative CEUS. CONCLUSION: CEUS combined with CT or MRI improves the accuracy of preoperative staging for hepatocellular carcinoma and may help to guide individualized treatment for patients with HCC. CEUS may better identify non-malignant lesions in patients with small tumors and discover new malignant lesions in patients with large tumors. (C) 2014 Baishideng Publishing Group Inc. All rights reserved. 展开更多
关键词 Hepatocellular carcinoma contrast-enhanced ultrasound Tumor node metastasis staging Intraoperative ultrasound Liver resection
下载PDF
Role of contrast-enhanced ultrasound in follow-up assessment after ablation for hepatocellular carcinoma 被引量:14
15
作者 Shu-Guang Zheng Hui-Xiong Xu +4 位作者 Ming-De Lu Xiao-Yan Xie Zuo-Feng Xu Guang-Jian Liu Lin-Na Liu 《World Journal of Gastroenterology》 SCIE CAS 2013年第6期855-865,共11页
AIM:To assess the usefulness of contrast-enhanced ultrasound (CEUS) during follow-up after percutaneous ablation therapy for hepatocellular carcinoma (HCC).METHODS:A total of 141 patients with HCCs who received percut... AIM:To assess the usefulness of contrast-enhanced ultrasound (CEUS) during follow-up after percutaneous ablation therapy for hepatocellular carcinoma (HCC).METHODS:A total of 141 patients with HCCs who received percutaneous ablation therapy were assessed by paired follow-up CEUS and contrast-enhanced computed tomography (CECT).The follow-up scheme was designed prospectively and the intervals between CEUS and CECT examinations were less than 14 d.Both im-ages of follow-up CEUS and CECT were reviewed by radiologists.The ablated lesions were evaluated and classified as local tumor progression (LTP) and LTPfree.LTP was defined as regrowth of tumor inside or adjacent to the successfully treated nodule.The detected new intrahepatic recurrences were also evaluated and defined as presence of intrahepatic new foci.On CEUS and CECT,LTP and new intrahepatic recurrence both were displayed as typical enhancement pattern of HCC (i.e.,hyper-enhancing during the arterial phase and washout in the late phase).With CECT as the reference standard,the ability of CEUS in detecting LTP or new intrahepatic recurrence during follow-up was evaluated.RESULTS:During a follow-up period of 1-31 mo (median,4 mo),169 paired CEUS and CECT examinations were carried out for the 141 patients.For a total of 221 ablated lesions,266 comparisons between CEUS and CECT findings were performed.Thirty-three LTPs were detected on CEUS whereas 40 LTPs were detected on CECT,there was significant difference (P < 0.001).In comparison with CECT,the numbers of false positive and false negative LTPs detected on CEUS were 6 and 13,respectively;the sensitivity,specificity,positive predictive value (PPV),negative predictive value (NPV) and overall accuracy of CEUS in detecting LTPs were 67.5%,97.4%,81.8%,94.4% and 92.3%,respectively.Meanwhile,131 new intrahepatic recurrent foci were detected on CEUS whereas 183 were detected on CECT,there was also significant difference (P < 0.05).In comparison with CECT,the numbers of false positive and false negative intrahepatic recurrences detected on CEUS were 13 and 65,respectively;the sensitivity,specificity,PPV,NPV and overall accuracy of CEUS in detecting new intrahepatic recurrent foci were 77.7%,92.0%,92.4%,76.7% and 84.0%,respectively.CONCLUSION:The sensitivity of CEUS in detecting LTP and new intrahepatic recurrence after percutaneous ablation therapy is relatively low in comparisonwith CECT. 展开更多
关键词 contrast-enhanced ultrasound Contrastenhanced COMPUTED tomography HEPATOCELLULAR CARCINOMA RADIOFREQUENCY ablation Microwave ablation
下载PDF
Review of dynamic contrast-enhanced ultrasound guidance in ablation therapy for hepatocellular carcinoma 被引量:24
16
作者 Yasunori Minami Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第45期4952-4959,共8页
Local ablative techniques-percutaneous ethanol injection, microwave coagulation therapy and radiofrequency ablation (RFA)-have been developed to treat unresectable hepatocellular carcinoma (HCC). The success rate of p... Local ablative techniques-percutaneous ethanol injection, microwave coagulation therapy and radiofrequency ablation (RFA)-have been developed to treat unresectable hepatocellular carcinoma (HCC). The success rate of percutaneous ablation therapy for HCC depends on correct targeting of the tumor via an imaging technique. However, probe insertion often is not completely accurate for small HCC nodules, which are poorly def ined on conventional B-mode ultrasound (US) alone. Thus, multiple sessions of ablation therapy are frequently required in diffi cult cases. By means of two breakthroughs in US technology, harmonic imaging and the development of second-generation contrast agents, dynamic contrast-enhanced harmonic US imaging with an intravenous contrast agent can depict tumor vascularity sensitively and accurately, and is able to evaluate small hypervascular HCCs even when B-mode US cannot adequately characterize the tumors. Therefore, dynamic contrast-enhanced US can facilitate RFA electrode placement in hypervascular HCC, which is poorly depicted by B-mode US. The use of dynamic contrast-enhanced US guidance in ablation therapy for liver cancer is an effi cient approach. Here, we present an overview of the current status of dynamic contrast-enhanced US-guided ablation therapy, and summarize the current indications and outcomes of reported clinical use in comparison with that of other modalities. 展开更多
关键词 Dynamic contrast-enhanced ultrasound Hepatocellular carcinoma Percutaneous ethanol injection Radiofrequency ablation
下载PDF
Application of contrast-enhanced ultrasound after livertransplantation:Current status and perspectives 被引量:11
17
作者 Jie Ren Tao Wu +3 位作者 Bo-Wen Zheng Ying-Yi Tan Rong-Qin Zheng Gui-Hua Chen 《World Journal of Gastroenterology》 SCIE CAS 2016年第4期1607-1616,共10页
Liver transplantation is an effective treatment for patients with end-stage liver disease. Accurate imaging evaluation of the transplanted patient is critical for ensuring that the limited donor liver is functioning a... Liver transplantation is an effective treatment for patients with end-stage liver disease. Accurate imaging evaluation of the transplanted patient is critical for ensuring that the limited donor liver is functioning appropriately. Ultrasound contrast agents(UCAs), in combination with contrastspecific imaging techniques, are increasingly accepted in clinical use for the assessment of the hepatic vasculature, bile ducts and liver parenchyma in pre-, intra- and posttransplant patients. We describe UCAs, their technical requirements, the recommended clinical indications, image interpretation and the limitations for contrastenhanced ultrasound applications in liver transplantation. 展开更多
关键词 Liver TRANSPLANT COMPLICATION ultrasoundcontrast AGENTS contrast-enhanced ultrasound Diagnosticalgorithms
下载PDF
Contrast-enhanced ultrasound in diagnosis and characterization of focal hepatic lesions 被引量:14
18
作者 Inés Gómez Molins Juan Manuel Fernández Font +3 位作者 Juan Carrero álvaro Jose Luís Lledó Navarro Marta Fernández Gil Conrado M Fernández Rodríguez 《World Journal of Radiology》 CAS 2010年第12期455-462,共8页
The extensive use of imaging techniques in differential diagnosis of abdominal conditions and screening of hepatocellular carcinoma in patients with chronic hepatic diseases,has led to an important increase in identif... The extensive use of imaging techniques in differential diagnosis of abdominal conditions and screening of hepatocellular carcinoma in patients with chronic hepatic diseases,has led to an important increase in identification of focal liver lesions.The development of contrastenhanced ultrasound(CEUS) opens a new window in the diagnosis and follow-up of these lesions.This technique offers obvious advantages over the computed tomography and magnetic resonance,without a decrease in its sensitivity and specificity.The new second generation contrast agents,due to their intravascular distribution,allow a continuous evaluation of the enhancement pattern,which is crucial in characterization of liver lesions.The dual blood supply in the liver shows three different phases,namely arterial,portal and late phases.The enhancement during portal and late phases can give important information about the lesion's behavior.Each liver lesion has a different enhancement pattern that makes possible an accurate approach to their diagnosis.The role of emerging techniques as a contrastenhanced three-dimensional US is also discussed.In this article,the advantages,indications and technique employed during CEUS and the different enhancement patterns of most benign and malignant focal liver lesions are discussed. 展开更多
关键词 FOCAL LIVER LESION ultrasound Contrast SONOGRAPHY contrast-enhanced ultrasound LIVER mass Hepatocellular carcinoma
下载PDF
Contrast-enhanced ultrasound:The evolving applications 被引量:23
19
作者 Hui-Xiong Xu 《World Journal of Radiology》 CAS 2009年第1期15-24,共10页
Contrast-enhanced ultrasound(CEUS)is a major breakthrough for ultrasound imaging in recent years.By using a microbubble contrast agent and contrast-specific imaging software,CEUS is able to depict the microand macro-c... Contrast-enhanced ultrasound(CEUS)is a major breakthrough for ultrasound imaging in recent years.By using a microbubble contrast agent and contrast-specific imaging software,CEUS is able to depict the microand macro-circulation of the targeted organ,which in turn leads to improved performance in diagnosis.Due to the special dual blood supply system in the liver,CEUS is particularly suitable for liver imaging.It is evident that CEUS facilitates improvement for characterization of focal liver lesions(FLLs),detection of liver malignancy,guidance for interventional procedures,and evaluation of treatment response after local therapies.CEUS has been demonstrated to be equal to contrast-enhanced computed tomography or magnetic resonance imaging for the characterization of FLLs.In addition,the applicability of CEUS has expanded to non-liver structures such as gallbladder,bile duct,pancreas,kidney,spleen,breast,thyroid,and prostate.The usefulness of CEUS in these applications is confirmed by extensive literature production.Novel applications include detecting bleeding sites and hematomas in patients with abdominal trauma,guiding percutaneous injection therapy and therefore achieving the goal of using interventional ultrasonography in managing splenic trauma,assessing the activity of Crohn’s disease,and detecting suspected endoleaks after endovascular abdominal aneurysm repair.Contrast-enhanced intraoperative ultrasound(US)and intracavitary use of CEUS have been developed and clinically studied.The potential use of CEUS involves sentinel lymph node detection,drug or gene delivery,and molecular imaging.In conclusion,the advent of CEUS has greatly enhanced the usefulness of US and even changed the status of US in clinical practice.The application of CEUS in the clinic is continuously evolving and it is expected that its use will be expanded further in the future. 展开更多
关键词 BILE duct Breast GALLBLADDER PANCREAS Kidney Liver contrast-enhanced ultrasound Prostate SPLEEN THYROID
下载PDF
Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions 被引量:18
20
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期610-617,共8页
AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesion... AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesions classified as BI-RADS 4 on conventional ultrasound were evaluated. CEUS was performed within one week before core needle biopsy or surgical resection and a revised BI-RADS classification was assigned based on 10 CEUS imaging characteristics. Receiver operating characteristic curve analysis was then conducted to evaluate the diagnostic performance of CEUS-based BI-RADS assignment with pathological examination as reference criteria. RESULTS: The CEUS-based BI-RADS evaluation classified 116/235(49.36%) lesions into category 3, 20(8.51%), 13(5.53%) and 12(5.11%) lesions into categories 4A, 4B and 4C, respectively, and 74(31.49%) into category 5. Selecting CEUS-based BI-RADS category 4A as an appropriate cut-off gave sensitivity and specificity values of 85.4% and 87.8%, respectively, for the diagnosisof malignant disease. The cancer-to-biopsy yield was 73.11% with CEUS-based BI-RADS 4A selected as the biopsy threshold compared with 40.85% otherwise, while the biopsy rate was only 42.13% compared with 100% otherwise. Overall, only 4.68% of invasive cancers were misdiagnosed.CONCLUSION: This pilot study suggests that evaluation of BI-RADS 4 breast lesions with CEUS results in reduced biopsy rates and increased cancer-to-biopsy yields. 展开更多
关键词 BREAST imaging REPORTING and data system contrast-enhanced ultrasound BIOPSY False POSITIVE BIOPSY
下载PDF
上一页 1 2 34 下一页 到第
使用帮助 返回顶部