Due to the importance of the inorganic materials removal from wastewater, experimental and analytical study to the concentration change with time of these materials became essential. In this work, experimental analyse...Due to the importance of the inorganic materials removal from wastewater, experimental and analytical study to the concentration change with time of these materials became essential. In this work, experimental analyses were performed to investigate the concentration changes of inorganic compounds during stages of activated sludge wastewater treatment plants at different sites in Jordan. The aim of this research is to examine the performance of the plants in treating pollutants and inorganic materials, and verify the quantitative and qualitative changes with time. Samples from the treatment stages were monthly taken and analyzed in the laboratory along a period of one year. The concentration changes of the inorganic solids in wastewater passing through treatment stages and aeration tank were recorded. Results show that the conventional treatment of the wastewater within different conditions in the year is not effective to decrease the concentrations of the inorganic compounds. Based on these results, we recommend adding tertiary advanced treatment unit in order to get acceptable water quality allowable to be reused for different purposes.展开更多
The sulfurous water deposit exploitation in volcanic, swamp, or wetland regions, represents an alternative option for potable water supply in cities and communities around the world. However, before its consumption, i...The sulfurous water deposit exploitation in volcanic, swamp, or wetland regions, represents an alternative option for potable water supply in cities and communities around the world. However, before its consumption, it must be treated by the application of physicochemical or biological methods with the ability to separate high contents in sulfates, hydrogen sulphite and sulphides which have laxative, allergic and toxic properties in humans. Conventional methods require the supply of chemical compounds or the adequate control of different parameters such as pH, temperature, etc., and the constant maintenance within their reactors. For these reasons, the systems could have elevated operating costs and require additional steps to enable the treatment of its separated products and the final disposal of its residual waste generated. In this research, compound parabolic collectors are implemented for the use of solar energy radiation, UV-B type, in Solar Advanced Oxidation Processes in H2O2/O3/UVsolar homogeneous phase. Its application during the pre-treatment of four sulfur water wells from the region of Puebla, Mexico, demonstrated its ability to transform their sulfur compounds in sulfates of easy removal by a later stage of reverse osmosis, in an approximately 15 min treatment time process.展开更多
Most of developing countries suffer from decreasing and poor quality of drinking water which led to emergence of many dangerous diseases. In addition, there isn’t any methodology followed to predict and disinfect dri...Most of developing countries suffer from decreasing and poor quality of drinking water which led to emergence of many dangerous diseases. In addition, there isn’t any methodology followed to predict and disinfect drinking water by using advanced software program. Maintaining water quality in the water distribution system has become a prominent issue in the study of the water network. Residual chlorine concentration is the indicator to ensure the quality of water in the water network because it eliminates contaminants in the distribution network beginning of the treatment plant down to the consumer. In collaboration with Alexandria (Egypt) Water Company, samples were taken from El-NOZHA water plant station and El-HADARA water distribution network to know the free residual chlorine. In this paper, WaterCAD software has been used to make hydraulic analysis and calibration of residual chlorine in water distribution network to know the ideal chlorine dose that should be added at the water treatment plant and to know the areas of strength and weakness in the concentration of free residual chlorine in the water distribution network. In addition different scenarios have been found to know the free residual chlorine at the weakness areas after injecting chlorine in some junctions and the impact of a fire case or breaking in the water pipe distribution network on the residual chlorine. Results showed ensuring in the water quality in the distribution network by adding chlorine dose in water less than the existing dose which has been added in the El-NOZHA water treatment plant. It is possible to maintain the percentage of free residual chlorine concentration at different locations without relying on adding chlorine only in water treatment plant by injecting low percentage of chlorine dose in the junctions.展开更多
文摘Due to the importance of the inorganic materials removal from wastewater, experimental and analytical study to the concentration change with time of these materials became essential. In this work, experimental analyses were performed to investigate the concentration changes of inorganic compounds during stages of activated sludge wastewater treatment plants at different sites in Jordan. The aim of this research is to examine the performance of the plants in treating pollutants and inorganic materials, and verify the quantitative and qualitative changes with time. Samples from the treatment stages were monthly taken and analyzed in the laboratory along a period of one year. The concentration changes of the inorganic solids in wastewater passing through treatment stages and aeration tank were recorded. Results show that the conventional treatment of the wastewater within different conditions in the year is not effective to decrease the concentrations of the inorganic compounds. Based on these results, we recommend adding tertiary advanced treatment unit in order to get acceptable water quality allowable to be reused for different purposes.
文摘The sulfurous water deposit exploitation in volcanic, swamp, or wetland regions, represents an alternative option for potable water supply in cities and communities around the world. However, before its consumption, it must be treated by the application of physicochemical or biological methods with the ability to separate high contents in sulfates, hydrogen sulphite and sulphides which have laxative, allergic and toxic properties in humans. Conventional methods require the supply of chemical compounds or the adequate control of different parameters such as pH, temperature, etc., and the constant maintenance within their reactors. For these reasons, the systems could have elevated operating costs and require additional steps to enable the treatment of its separated products and the final disposal of its residual waste generated. In this research, compound parabolic collectors are implemented for the use of solar energy radiation, UV-B type, in Solar Advanced Oxidation Processes in H2O2/O3/UVsolar homogeneous phase. Its application during the pre-treatment of four sulfur water wells from the region of Puebla, Mexico, demonstrated its ability to transform their sulfur compounds in sulfates of easy removal by a later stage of reverse osmosis, in an approximately 15 min treatment time process.
文摘Most of developing countries suffer from decreasing and poor quality of drinking water which led to emergence of many dangerous diseases. In addition, there isn’t any methodology followed to predict and disinfect drinking water by using advanced software program. Maintaining water quality in the water distribution system has become a prominent issue in the study of the water network. Residual chlorine concentration is the indicator to ensure the quality of water in the water network because it eliminates contaminants in the distribution network beginning of the treatment plant down to the consumer. In collaboration with Alexandria (Egypt) Water Company, samples were taken from El-NOZHA water plant station and El-HADARA water distribution network to know the free residual chlorine. In this paper, WaterCAD software has been used to make hydraulic analysis and calibration of residual chlorine in water distribution network to know the ideal chlorine dose that should be added at the water treatment plant and to know the areas of strength and weakness in the concentration of free residual chlorine in the water distribution network. In addition different scenarios have been found to know the free residual chlorine at the weakness areas after injecting chlorine in some junctions and the impact of a fire case or breaking in the water pipe distribution network on the residual chlorine. Results showed ensuring in the water quality in the distribution network by adding chlorine dose in water less than the existing dose which has been added in the El-NOZHA water treatment plant. It is possible to maintain the percentage of free residual chlorine concentration at different locations without relying on adding chlorine only in water treatment plant by injecting low percentage of chlorine dose in the junctions.