A mathematical model was developed to predict the maximum heat transfer capacity of high temperature heat pipe with triangular grooved wick. The effects of the inclination angle and geometry structure were considered ...A mathematical model was developed to predict the maximum heat transfer capacity of high temperature heat pipe with triangular grooved wick. The effects of the inclination angle and geometry structure were considered in the proposed model.Maximum heat transfer capacity was also investigated experimentally. The model was validated by comparing with the experimental results. The maximum heat transfer capacity increases with the vapor core radius increasing. Compared with the inclination angle of0°, the maximum heat transfer capacity increases at the larger inclination angle, and the change with temperature is larger. The performance of heat pipe with triangular grooved wick is greatly influenced by gravity, so it is not recommended to be applied to the dish solar heat pipe receiver.展开更多
In order to study the influence of inlet and outlet pressure difference and triangular buffer groove on the internal leakage of continuous rotary electro-hydraulic servo motor,the flow field model of motor with and wi...In order to study the influence of inlet and outlet pressure difference and triangular buffer groove on the internal leakage of continuous rotary electro-hydraulic servo motor,the flow field model of motor with and without triangular groove is established respectively.The mesh model is divided.The pressure distribution of the internal flow field under different pressure difference is analyzed by Fluent.Then,the gap leakage under different pressure difference is calculated,and the leakage curve is obtained.Finally,continuous rotary electro-hydraulic servo motor experimental system is built to conduct the internal leakage test,and the leakage under different pressure difference is measured and compared with the simulation results.The results show that the occurrence of leakage in the motor can be reduced by setting the triangular buffer groove on the flow plate,the simulation and experimental results are consistent.It can be concluded that the larger the pressure difference between the inlet and the outlet of the motor,the larger the gap leakage.The research lays foundation for the application of continuous rotary electro-hydraulic servo motor.展开更多
基金Project(51076062)supported by the National Natural Science Foundation of China
文摘A mathematical model was developed to predict the maximum heat transfer capacity of high temperature heat pipe with triangular grooved wick. The effects of the inclination angle and geometry structure were considered in the proposed model.Maximum heat transfer capacity was also investigated experimentally. The model was validated by comparing with the experimental results. The maximum heat transfer capacity increases with the vapor core radius increasing. Compared with the inclination angle of0°, the maximum heat transfer capacity increases at the larger inclination angle, and the change with temperature is larger. The performance of heat pipe with triangular grooved wick is greatly influenced by gravity, so it is not recommended to be applied to the dish solar heat pipe receiver.
基金the National Natural Science Foundation of China(No.51975164)the China Scholarship Council(No.201908230358)the Fundamental Research Fundation for Universities of Heilongjiang Province(No.2019-KYYWF-0205)。
文摘In order to study the influence of inlet and outlet pressure difference and triangular buffer groove on the internal leakage of continuous rotary electro-hydraulic servo motor,the flow field model of motor with and without triangular groove is established respectively.The mesh model is divided.The pressure distribution of the internal flow field under different pressure difference is analyzed by Fluent.Then,the gap leakage under different pressure difference is calculated,and the leakage curve is obtained.Finally,continuous rotary electro-hydraulic servo motor experimental system is built to conduct the internal leakage test,and the leakage under different pressure difference is measured and compared with the simulation results.The results show that the occurrence of leakage in the motor can be reduced by setting the triangular buffer groove on the flow plate,the simulation and experimental results are consistent.It can be concluded that the larger the pressure difference between the inlet and the outlet of the motor,the larger the gap leakage.The research lays foundation for the application of continuous rotary electro-hydraulic servo motor.