The matrix effects of 14 organophosphorus pesticides in 9 kinds of vegetables matrices were preliminarily studied by gas chromatography/flame photomet- ric detection(FPD) in the paper. The matrix effects of 14 organ...The matrix effects of 14 organophosphorus pesticides in 9 kinds of vegetables matrices were preliminarily studied by gas chromatography/flame photomet- ric detection(FPD) in the paper. The matrix effects of 14 organophosphoms pesticides in 9 kinds of vegetable matrices at 0.05, 0.1 and 0.2 mg/L were compared, respectively. The results showed that matrix enhancement effect and matrix attenuation effect existed in all cases, while matrix effects did not have strong correlation with concentrations of pesticides, but were related to species of vegetables and structure and polarity of pesticides.展开更多
Background: This study evaluates the quantitative assessment of persistent organochorine pesticide (OCPs) residues in vegetables (Senecio biafrae) from four selected cocoa plantations in Ekiti State, Nigeria. Methods:...Background: This study evaluates the quantitative assessment of persistent organochorine pesticide (OCPs) residues in vegetables (Senecio biafrae) from four selected cocoa plantations in Ekiti State, Nigeria. Methods: The pesticides were extracted from the vegetable samples by using USEPA 3500C method and later clean-up on activated silica gel. The pesticides residues in the samples were determined using Gas Chromatography coupled with Electron Capture Detector (GC-ECD). Results: The results showed that the analyzed samples were contaminated with ten OCPs. The mean OCPs concentration ranged from ND—0.399 mg/kg to ND—0.379 mg/kg during the wet and dry seasons respectively. α-BHC, β-BHC, p, p’-DDE, dieldrin, endrin, endosulfan sulphate and methoxychlor were not detected in the samples. Pesticides such as aldrin, endosulfan II, endrin aldehyde and heptachlor slightly exceeded their maximum residue limit. Conclusion: The hazard indices (HI) of heptachlor, endosulfan I, endosulfan II, aldrin, heptachlor-epoxide and p, p’-DDT exceeded 1 and thus pose likely potential non-carcinogenic health risk.展开更多
To establish a new GC-MS/MS method for quantitative detection of 22 kinds of pesticide in fruit and vegetable including organic phosphorus,carbamate & pyrethrin etc.Working was performed by Xcalibur software with ...To establish a new GC-MS/MS method for quantitative detection of 22 kinds of pesticide in fruit and vegetable including organic phosphorus,carbamate & pyrethrin etc.Working was performed by Xcalibur software with multitask mode.We Carried on qualitative and quantitative analysis to mass spectrum of MS/MS in order to obtained a credible experiment result.This method is sensitive and accurate,it is suitable for determination of multifarious pesticide residues.展开更多
The present study was aimed to validate an analytical method for the quantification of 19 organochlorine and 2 synthetic pyrethroid pesticide residues in water samples using modified quick, easy, cheap, effective, rug...The present study was aimed to validate an analytical method for the quantification of 19 organochlorine and 2 synthetic pyrethroid pesticide residues in water samples using modified quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction and Gas Chromatography coupled with Electron Capture Detector (ECD). The selected pesticide residues were determined by in-house validated method. The analytical method was validated by evaluating the accuracy, precision, linearity, limit of detection (LOD) and limit of quantification (LOQ). The average recoveries of the selected pesticides ranged from 78% to 117% with RSDr ≤ 12% in two fortification levels of 0.02 and 0.1 mg/L. The linearity was ≥0.995 for all of the selected pesticides. The LOD ranged from 0.003 to 0.006 mg/L and the LOQ was 0.02 mg/L for all the selected analytes. This method was applied satisfactorily for the residue analysis of 108 water samples collected from nine districts of Bangladesh. Among the analyzed samples, only 4 had cypermethrin residues (0.026 mg/L, 0.034 mg/L, 0.045 mg/L and 0.05 mg/L). The level of detected cypermethrin residues were above the WHO recommended guide line values of water quality.展开更多
文摘The matrix effects of 14 organophosphorus pesticides in 9 kinds of vegetables matrices were preliminarily studied by gas chromatography/flame photomet- ric detection(FPD) in the paper. The matrix effects of 14 organophosphoms pesticides in 9 kinds of vegetable matrices at 0.05, 0.1 and 0.2 mg/L were compared, respectively. The results showed that matrix enhancement effect and matrix attenuation effect existed in all cases, while matrix effects did not have strong correlation with concentrations of pesticides, but were related to species of vegetables and structure and polarity of pesticides.
文摘Background: This study evaluates the quantitative assessment of persistent organochorine pesticide (OCPs) residues in vegetables (Senecio biafrae) from four selected cocoa plantations in Ekiti State, Nigeria. Methods: The pesticides were extracted from the vegetable samples by using USEPA 3500C method and later clean-up on activated silica gel. The pesticides residues in the samples were determined using Gas Chromatography coupled with Electron Capture Detector (GC-ECD). Results: The results showed that the analyzed samples were contaminated with ten OCPs. The mean OCPs concentration ranged from ND—0.399 mg/kg to ND—0.379 mg/kg during the wet and dry seasons respectively. α-BHC, β-BHC, p, p’-DDE, dieldrin, endrin, endosulfan sulphate and methoxychlor were not detected in the samples. Pesticides such as aldrin, endosulfan II, endrin aldehyde and heptachlor slightly exceeded their maximum residue limit. Conclusion: The hazard indices (HI) of heptachlor, endosulfan I, endosulfan II, aldrin, heptachlor-epoxide and p, p’-DDT exceeded 1 and thus pose likely potential non-carcinogenic health risk.
文摘To establish a new GC-MS/MS method for quantitative detection of 22 kinds of pesticide in fruit and vegetable including organic phosphorus,carbamate & pyrethrin etc.Working was performed by Xcalibur software with multitask mode.We Carried on qualitative and quantitative analysis to mass spectrum of MS/MS in order to obtained a credible experiment result.This method is sensitive and accurate,it is suitable for determination of multifarious pesticide residues.
文摘The present study was aimed to validate an analytical method for the quantification of 19 organochlorine and 2 synthetic pyrethroid pesticide residues in water samples using modified quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction and Gas Chromatography coupled with Electron Capture Detector (ECD). The selected pesticide residues were determined by in-house validated method. The analytical method was validated by evaluating the accuracy, precision, linearity, limit of detection (LOD) and limit of quantification (LOQ). The average recoveries of the selected pesticides ranged from 78% to 117% with RSDr ≤ 12% in two fortification levels of 0.02 and 0.1 mg/L. The linearity was ≥0.995 for all of the selected pesticides. The LOD ranged from 0.003 to 0.006 mg/L and the LOQ was 0.02 mg/L for all the selected analytes. This method was applied satisfactorily for the residue analysis of 108 water samples collected from nine districts of Bangladesh. Among the analyzed samples, only 4 had cypermethrin residues (0.026 mg/L, 0.034 mg/L, 0.045 mg/L and 0.05 mg/L). The level of detected cypermethrin residues were above the WHO recommended guide line values of water quality.