期刊文献+
共找到36,963篇文章
< 1 2 250 >
每页显示 20 50 100
Stepped-up development of accelerator mass spectrometry method for the detection of ^(60)Fe with the HI-13 tandem accelerator 被引量:1
1
作者 Yang Zhang Sheng-Quan Yan +36 位作者 Ming He Qing-Zhang Zhao Wen-Hui Zhang Chao-Xin Kan Jian-Ming Zhou Kang-Ning Li Xiao-Fei Wang Jian-Cheng Liu Zhao-Hua Peng Zhuo Liang Ai-Ling Li Jian Zheng Qi-Wen Fan Yun-Ju Li You-Bao Wang Zhi-Hong Li Yang-Ping Shen Ding Nan Wei Nan Yu-Qiang Zhang Jia-Ying-Hao Li Jun-Wen Tian Jiang-Lin Hou Chang-Xin Guo Zhi-Cheng Zhang Ming-Hao Zhu Yu-Wen Chen Yu-Chen Jiang Tao Tian Jin-Long Ma Yi-Hui Liu Jing-Yu Dong Run-Long Liu Mei-Yue-Nan Ma Yong-Shou Chen Wei-Ping Liu Bing Guo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期136-143,共8页
The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides... The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides such as^(60)Fe.In this work,we stepped up the development of an accelerator mass spectrometry(AMS)method for detecting^(60)Fe using the HI-13tandem accelerator at the China Institute of Atomic Energy(CIAE).Since interferences could not be sufficiently removed solely with the existing magnetic systems of the tandem accelerator and the following Q3D magnetic spectrograph,a Wien filter with a maximum voltage of±60 kV and a maximum magnetic field of 0.3 T was installed after the accelerator magnetic systems to lower the detection background for the low abundance nuclide^(60)Fe.A 1μm thick Si_(3)N_(4) foil was installed in front of the Q3D as an energy degrader.For particle detection,a multi-anode gas ionization chamber was mounted at the center of the focal plane of the spectrograph.Finally,an^(60)Fe sample with an abundance of 1.125×10^(-10)was used to test the new AMS system.These results indicate that^(60)Fe can be clearly distinguished from the isobar^(60)Ni.The sensitivity was assessed to be better than 4.3×10^(-14)based on blank sample measurements lasting 5.8 h,and the sensitivity could,in principle,be expected to be approximately 2.5×10^(-15)when the data were accumulated for 100 h,which is feasible for future lunar sample measurements because the main contaminants were sufficiently separated. 展开更多
关键词 Accelerator mass spectrometry Wien filter Isobar separation SUPERNOVAE Chang'e-5 lunar samples
下载PDF
Pharmacokinetic Comparison of Four Major Bio-Active Components of Naoxintong Capsule in Normal and Acute Blood Stasis Rats Using Ultra-Performance Liquid Chromatography Coupled with Triple-Quadrupole Mass Spectrometry 被引量:1
2
作者 Wei-Xia Li Shu-Qi Zhang +5 位作者 Man-Man Li Hui Zhang Xiao-Yan Wang Lu Niu Jin-Fa Tang Xue-Lin Li 《World Journal of Traditional Chinese Medicine》 2022年第1期92-99,共8页
Objective: To compare the pharmacokinetic differences of the main components of Naoxintong capsule(NXTC) in normal and acute blood stasis rats. Materials and Methods: Rats were subcutaneously injected with adrenaline ... Objective: To compare the pharmacokinetic differences of the main components of Naoxintong capsule(NXTC) in normal and acute blood stasis rats. Materials and Methods: Rats were subcutaneously injected with adrenaline hydrochloride twice;during the two subcutaneous injections, the rats were placed in ice water for 4 min to reproduce the model rat of acute blood stasis. The normal and acute blood stasis rats were administrated a 5.04 g/kg dose of NXTC suspension. Then, blood samples were collected from the posterior retinal venous plexus at different time points. Plasma concentrations of four major bio-active components including caffeic acid, ferulic acid, formononetin, and tanshinone IIA in NXTC were measured using ultra-performance liquid chromatography coupled with triple-quadrupole mass spectrometry. Phoenix Win Nonlin v6.2 software was used to calculate the pharmacokinetic parameters. Results: Compared with the normal rats, the acute blood stasis rats showed a significant decrease in C_(max) of ferulic acid and formononetin, AUC_(all) of caffeic acid and ferulic acid, and AUC_(INF_obs) of ferulic acid. Conversely, an increase in the Vz_F_obs and MRT_(last) of ferulic acid and caffeic acid was observed. These findings demonstrate that the absorption of the four NXTC components was weakened in the acute blood stasis rats and that the elimination time was prolonged. Conclusions: The significant difference in some parameters of the four NXTC components between the normal and acute blood stasis rats might be caused by an increase in blood viscosity and the subsequent slowing down of blood flow in the acute blood stasis rats. The pharmacokinetic study conducted in pathological state can provide important information and scientific basis for further rational clinical application of NXTC. 展开更多
关键词 Acute blood stasis rat model Naoxintong capsules PHARMACOKINETICS ultra-performance liquid chromatography coupled with triple-quadrupole mass spectrometry
原文传递
Improved isochronous mass spectrometry with tune measurement
3
作者 Han-Yu Deng Yuan-Ming Xing +5 位作者 Xu Zhou Yu-Hu Zhang Xin-Liang Yan Jin-Yang Shi Ting Liao Meng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第11期174-181,共8页
In conventional isochronous mass spectrometry(IMS)performed on a storage ring,the precision of mass measurements for short-lived nuclei depends on the accurate determination of the revolution times(T)of stored ions.Ho... In conventional isochronous mass spectrometry(IMS)performed on a storage ring,the precision of mass measurements for short-lived nuclei depends on the accurate determination of the revolution times(T)of stored ions.However,the resolution of T inevitably deteriorates due to the magnetic rigidity spread of the ions,limiting the mass-resolving power.In this study,we used the betatron tunes Q(the number of betatron oscillations per revolution)of the ions and established a correlation between T and Q.From this correlation,T was transformed to correspond to a fixed Q with higher resolution.Using these transformed T values,the masses of ^(63)Ge,^(65)As,^(67)Se,and ^(71)Kr agreed well with the mass values measured using the newly developed IMS(Bρ-IMS).We also studied the systematics of Coulomb displacement energies(CDEs)and found that anomalous staggering in CDEs was eliminated using new mass values.This method of T transformation is highly effective for conventional IMS equipped with a single time-of-flight detector. 展开更多
关键词 Isochronous mass spectrometry Storage ring TUNE Natural chromaticity Nuclear mass measurement
下载PDF
Ultra-soft Desorption Assisted Mass Spectrometry using Picosecond Infrared Laser for the Detection of lons in the Liquid Surface
4
作者 Ziyuan Li Yue Wang +2 位作者 Tiantian Tong Ziwei Chen Shan Xi Tian 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2024年第4期461-464,I0093,共5页
To identify the species in liquid surface using mass spectrometry,we must eliminate or reduce interferences during the vaporization or desorption of the species from the liquid surface.It is much more challenging to i... To identify the species in liquid surface using mass spectrometry,we must eliminate or reduce interferences during the vaporization or desorption of the species from the liquid surface.It is much more challenging to isolate the ionic,larger species from the liquid surface,because of the frangible structures and the higher solvation energies of those species.Here we demonstrate a new mass spectrometry in which the ionic species at the liquid surface can be desorbed with ultrasoft infrared picosecond laser pulses while the liquid surface is not breached.This laser desorption assisted mass spectrometry is not only a powerful tool to detect the fragile species but also promising to investigate vibrational energy transfer dynamics in the liquid surface. 展开更多
关键词 Ultrasoft desorption Infrared laser Picosecond pulse mass spectrometry Liquid surface
下载PDF
Determination of Ten Kinds of Alpha-2 Agonists Residues in Animal Derived Food by UHPLC-Triple Quadrupole/Composite Linear Ion Trap Mass Spectrometry
5
作者 Fang LI Xuemei LI +3 位作者 Xiangang LI Sining LIU Sha LIU Ying WANG 《Plant Diseases and Pests》 2024年第1期28-32,共5页
[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f... [Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food. 展开更多
关键词 Animal derived food α_(2)-receptor agonist Solid-phase extraction Ultra-high performance liquid phase-triple quadrupole/linear ion trap composite mass spectrometry
下载PDF
Research on the Upper Limit of Accuracy for Predicting Theoretical Tandem Mass Spectrometry
6
作者 Changjiu He Xiaoyu Wang +1 位作者 Mingming Lyu Xinye Bian 《Journal of Computer and Communications》 2024年第3期184-195,共12页
In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy... In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy of current methods approaches this limit, further exploration of new prediction techniques may become redundant. Conversely, a need for more precise prediction methods or models may be indicated. In this study, we have experimentally analyzed the limits of accuracy at different numbers of ions and parameters using repeated spectral pairs and integrating various similarity metrics. Results show significant achievements in accuracy for backbone ion methods with room for improvement. In contrast, full-spectrum prediction methods exhibit greater potential relative to the theoretical accuracy limit. Additionally, findings highlight the significant impact of normalized collision energy and instrument type on prediction accuracy, underscoring the importance of considering these factors in future theoretical tandem mass spectrometry predictions. 展开更多
关键词 Tandem mass spectrometry Spectral Prediction Theoretical Limit
下载PDF
Spatiotemporal pharmacometabolomics based on ambient mass spectrometry imaging to evaluate the metabolism and hepatotoxicity of amiodarone in HepG2 spheroids 被引量:3
7
作者 Limei Li Qingce Zang +5 位作者 Xinzhu Li Ying Zhu Shanjing Wen Jiuming He Ruiping Zhang Zeper Abliz 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第5期483-493,共11页
Three-dimensional(3D)cell spheroid models combined with mass spectrometry imaging(MSI)enables innovative investigation of in vivo-like biological processes under different physiological and pathological conditions.Her... Three-dimensional(3D)cell spheroid models combined with mass spectrometry imaging(MSI)enables innovative investigation of in vivo-like biological processes under different physiological and pathological conditions.Herein,airflow-assisted desorption electrospray ionization-MSI(AFADESI-MSI)was coupled with 3D HepG2 spheroids to assess the metabolism and hepatotoxicity of amiodarone(AMI).High-coverage imaging of>1100 endogenous metabolites in hepatocyte spheroids was achieved using AFADESI-MSI.Following AMI treatment at different times,15 metabolites of AMI involved in Ndesethylation,hydroxylation,deiodination,and desaturation metabolic reactions were identified,and according to their spatiotemporal dynamics features,the metabolic pathways of AMI were proposed.Subsequently,the temporal and spatial changes in metabolic disturbance within spheroids caused by drug exposure were obtained via metabolomic analysis.The main dysregulated metabolic pathways included arachidonic acid and glycerophospholipid metabolism,providing considerable evidence for the mechanism of AMI hepatotoxicity.In addition,a biomarker group of eight fatty acids was selected that provided improved indication of cell viability and could characterize the hepatotoxicity of AMI.The combination of AFADESI-MSI and HepG2 spheroids can simultaneously obtain spatiotemporal information for drugs,drug metabolites,and endogenous metabolites after AMI treatment,providing an effective tool for in vitro drug hepatotoxicity evaluation. 展开更多
关键词 mass spectrometry imaging HepG2 spheroids HEPATOTOXICITY Drug metabolism AMIODARONE
下载PDF
Evaluation of allergenic protein profiles in three Chinese high-oleic acid peanut cultivars using NanoLC-Orbitrap mass spectrometry 被引量:1
8
作者 Xinke Yang Haochen Bai +3 位作者 Lijun Yin Jin Wang Wentong Xue Xin Jia 《Food Science and Human Wellness》 SCIE CSCD 2023年第3期851-860,共10页
High oleic-acid peanuts are known for their pre-longed shelf-life and health benefit due to high content of oleic fatty acid.However,the allergenicity and allergenic protein profiles in Chinese high-oleic peanuts have... High oleic-acid peanuts are known for their pre-longed shelf-life and health benefit due to high content of oleic fatty acid.However,the allergenicity and allergenic protein profiles in Chinese high-oleic peanuts have yet to be studied.For this purpose,an Orbitrap Fusion mass spectrometry(MS)-based method that is feasible for identification of putative allergenic protein as well as semi-quantitation of five major allergen protein in three different Chinese high-oleic peanut cultivars(JH 13,JH 16 and JH 18)have been reported.Results show that three Chinese high-oleic acid peanut cultivars selected all contained highly allergenic proteins Ara h1,Ara h 2,Ara h 3 and Ara h 6.The allergenic protein profiles of Chinese high-oleic acid peanut cultivars were very similar to that of conventional peanuts,but the allergenic protein subunits varied greatly among higholeic peanuts.Additionally,a comprehensive peptide-filtering pipeline had been developed for identification of potential peptide markers in peanut allergen proteins.Through the peptide-filtering pipeline,three novel peptide markers,IVQIEAKPNTLVLPK,SSNPDIYNPQAGSLR and AQSENYEYLAFK surrogate to Ara h 1,Ara h 3 with high abundance,good MS response and highly reliability were identified,which can be used as candidate peptide markers for the detection of peanut allergens in different food matrices. 展开更多
关键词 ALLERGY High-oleic acid peanut Peptide-filtering pipeline NanoLC-Orbitrap mass spectrometry
下载PDF
Nylon 6-cellulose composite hosted in a hypodermic needle: Biofluid extraction and analysis by ambient mass spectrometry in a single device
9
作者 Jaime Millan-Santiago Rafael Lucena Soledad Cardenas 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第11期1346-1352,共7页
This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed t... This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed to extract methadone from oral fluid samples.The cellulosic substrate provides the composite with high porosity,permitting the flow-through of the sample,while the polyamide contributes to the extraction of the analyte.The low price of the devices(considering the holder and the sorbent)contributes to the affordability of the method,and their small size allows easy transportation,opening the door to on-site extractions.Under the optimum conditions,the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection(LOD)as low as 0.3 mg/L and precision(expressed as relative standard deviation,RSD)better than 9.3%.The trueness,expressed as relative recovery(RR),ranged from 90%to 109%.As high-resolution mass spectrometers are not available in many laboratories,the method was also adapted to low-resolution spectrometers.In this sense,the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 mg/L.The RSD was better than 5.3%,and the RR ranged from 96%to 121%. 展开更多
关键词 ESI emitter mass spectrometry Hypodermic needle COMPOSITE METHADONE
下载PDF
Tracking gassing behavior in pouch cell by operando on-line electrochemical mass spectrometry
10
作者 Haitang Zhang Jianken Chen +10 位作者 Baodan Zhang Xiaohong Wu Zhengang Li Leiyu Chen Junhao Wang Xiaoyu Yu Haiyan Luo Jiyuan Xue Yu-Hao Hong Yu Qiao Shi-Gang Sun 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第9期286-291,共6页
As the rapid development of more powerful and safer lithiumion batteries, the mechanism study of gases evolution is attacking more and more attention in recent years. Especially under overcharge/discharge and/or high-... As the rapid development of more powerful and safer lithiumion batteries, the mechanism study of gases evolution is attacking more and more attention in recent years. Especially under overcharge/discharge and/or high-temperature working condition. 展开更多
关键词 Pouch cell Operando characterization mass spectrometry Lithium-ion batteries Gassing behavior
下载PDF
Integrated mass spectrometry imaging reveals spatial-metabolic alteration in diabetic cardiomyopathy and the intervention effects of ferulic acid
11
作者 Yanhua Liu Xin Zhang +6 位作者 Shu Yang Zhi Zhou Lu Tian Wanfang Li Jinfeng Wei Zeper Abliz Zhonghua Wang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第12期1496-1509,共14页
Diabetic cardiomyopathy(DCM)is a metabolic disease and a leading cause of heart failure among people with diabetes.Mass spectrometry imaging(MSI)is a versatile technique capable of combining the molecular specificity ... Diabetic cardiomyopathy(DCM)is a metabolic disease and a leading cause of heart failure among people with diabetes.Mass spectrometry imaging(MSI)is a versatile technique capable of combining the molecular specificity of mass spectrometry(MS)with the spatial information of imaging.In this study,we used MSI to visualize metabolites in the rat heart with high spatial resolution and sensitivity.We optimized the air flow-assisted desorption electrospray ionization(AFADESI)-MSI platform to detect a wide range of metabolites,and then used matrix-assisted laser desorption ionization(MALDI)-MSI for increasing metabolic coverage and improving localization resolution.AFADESI-MSI detected 214 and 149 metabolites in positive and negative analyses of rat heart sections,respectively,while MALDI-MSI detected 61 metabolites in negative analysis.Our study revealed the heterogenous metabolic profile of the heart in a DCM model,with over 105 region-specific changes in the levels of a wide range of metabolite classes,including carbohydrates,amino acids,nucleotides,and their derivatives,fatty acids,glycerol phospholipids,carnitines,and metal ions.The repeated oral administration of ferulic acid during 20 weeks significantly improved most of the metabolic disorders in the DCM model.Our findings provide novel insights into the molecular mechanisms underlying DCM and the potential of ferulic acid as a therapeutic agent for treating this condition. 展开更多
关键词 mass spectrometry imaging Diabetic cardiomyopathy Metabolic reprogramming Ferulic acid
下载PDF
Identification,structure elucidation and origin of a common pyridinium-thiocyanate intermediate in electrospray mass spectrometry among the benziamidazole-class proton pump inhibitors
12
作者 Dong Sun Chunyu Wang +1 位作者 Yanxia Fan Jingkai Gu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第6期683-688,共6页
During the analysis of benziamidazole-class irreversible proton pump inhibitors,an unusual mass spectral response with the mass-to-charge ratio at[Mt10]t intrigued us,as it couldn't be assigned to any literature k... During the analysis of benziamidazole-class irreversible proton pump inhibitors,an unusual mass spectral response with the mass-to-charge ratio at[Mt10]t intrigued us,as it couldn't be assigned to any literature known relevant structure,intermediate or adduct ion.Moreover,this mysterious mass pattern of[Mt10]t has been gradually observed by series of marketed proton pump inhibitors,viz.omeprazole,pantoprazole,lansoprazole and rabeprazole.All the previous attempts to isolate the corresponding component were unsuccessful.The investigation of present work addresses this kind of signal to a pyridinium thiocyanate mass spectral intermediate(10),which is the common fragment ion of series of labile aggregates.The origin of such aggregates can be traced to the reactive intermediates formed by acid-promoted degradation.These reactive intermediates tend to react with each other and give raise series of complicated aggregates systematically in a water/acetonitrile solution by electrospray ionization.The structure of the corresponding pyridinium thiocyanate species of omeprazole(10a)has been eventually characterized with the help of synthetic specimen(10a′).Our structural proposal as well as its origin was supported by in situ nuclear magnetic resonance,chemical derivatization and colorimetric experiments. 展开更多
关键词 Proton pump inhibitor mass spectrometry Electrospray ionization Pseudo-molecular ion Pyridinium thiocyanate
下载PDF
Rapid authentication of different herbal medicines by heating online extraction electrospray ionization mass spectrometry
13
作者 Zidong Qiu Chaofa Wei +9 位作者 Xiang Li Changjiangsheng Lai Zhilai Zhan Yan Jin Li Zhou Qingxiu Hao Jian Yang Shuanglong Wang Liping Kang Luqi Huang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第3期296-304,共9页
The rapid and accurate authentication of traditional Chinese medicines(TCMs)has always been a key scientific and technical problem in the field of pharmaceutical analysis.Herein,a novel heating online extraction elect... The rapid and accurate authentication of traditional Chinese medicines(TCMs)has always been a key scientific and technical problem in the field of pharmaceutical analysis.Herein,a novel heating online extraction electrospray ionization mass spectrometry(H-oEESI-MS)was developed for the rapid and direct analysis of extremely complex substances without the requirement for any sample pretreatment or pre-separation steps.The overall molecular profile and fragment structure features of various herbal medicines could be completely captured within 10–15 s,with minimal sample(<0.5 mg)and solvent consumption(<20μL for one sample).Furthermore,a rapid differentiation and authentication strategy for TCMs based on H-oEESI-MS was proposed,including metabolic profile characterization,characteristic marker screening and identification,and multivariate statistical analysis model validation.In an analysis of 52 batches of seven types of Aconitum medicinal materials,20 and 21 key compounds were screened out as the characteristic markers of raw and processed Aconitum herbal medicines,respectively,and the possible structures of all the characteristic markers were comprehensively identified based on Compound Discoverer databases.Finally,multivariate statistical analysis showed that all the different types of herbal medicines were well differentiated and identified(R^(2)X>0.87,R^(2)Y>0.91,and Q^(2)>0.72),which further verified the feasibility and reliability of this comprehensive strategy for the rapid authentication of different TCMs based on H-oEESI-MS.In summary,this rapid authentication strategy realized the ultra-high-throughput,low-cost,and standardized detection of various complex TCMs for the first time,thereby demonstrating wide applicability and value for the development of quality standards for TCMs. 展开更多
关键词 Heating online extraction electrospray ionization mass spectrometry Rapid authentication Traditional Chinese medicine
下载PDF
Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma
14
作者 Wei Zhou Martyna N.Wieczorek +1 位作者 Runshan Will Jiang Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第2期216-222,共7页
The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as b... The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma.In recent years,our lab has developed three novel SPME-MS techniques:SPME-microfluidic open interface-MS(SPME-MOI-MS),coated blade spray-MS(CBS-MS),and SPME-probe electrospray ionization-MS(SPME-PESI-MS).The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing.However,all these three techniques utilize different SPME geometries and were tested with different MS instruments.Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application.This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers,CBS blades,and SPME-PESI probes and SPME-liquid chromatography-MS(SPME-LC-MS)for the analysis of drugs of abuse using the same MS instrument.Furthermore,for the first time,we developed different desorption chambers for MOI-MS for coupling with SPME fibers,CBS blades,and SPME-PESI probes,thus illustrating the universality of this approach.In total,eight analytical methods were developed,with the experimental data showing that all the SPME-based methods provided good analytical performance with R^(2)of linearities larger than 0.9925,accuracies between 81%and 118%,and good precision with an RSD%≤13%. 展开更多
关键词 Solid-phase microextraction mass spectrometry Microfluidic open interface Coated blade spray Probe electrospray ionization Drug of abuse
下载PDF
Determination of Voriconazole in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application in Therapeutic Drug Monitoring
15
作者 Waleed Alhussaini Ezzeldeen Ghanem +4 位作者 Magd Alsahly Amani Kurdi Eman Alharbi Imadul Islam Majed Aljeraisy 《American Journal of Analytical Chemistry》 2023年第9期378-389,共12页
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona... A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM. 展开更多
关键词 VORICONAZOLE Human Plasma Liquid Chromatography Tandem mass spectrometry Therapeutic Drug Monitoring
下载PDF
Determination of egg and milk allergen in food products by liquid chromatography-tandem mass spectrometry based on signature peptides and isotope-labeled internal standard
16
作者 Sufang Fan Junmei Ma +4 位作者 Zhuo Liu Yawei Ning Meicong Cao Qiang Li Yan Zhang 《Food Science and Human Wellness》 SCIE CSCD 2023年第3期728-736,共9页
The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLD... The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples. 展开更多
关键词 Liquid chromatography-tandem mass spectrometry Egg and milk allergen Signature peptides Isotope-labeled internal standards
下载PDF
Simultaneous Determination of 14 β-Receptor Agonists Residues in Mutton by High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
17
作者 Zhe MENG Jianhua WANG +5 位作者 Bo LIU Yuhang GUO Haoshuang DONG Pingyang SHAN Dawei WANG Yajuan SONG 《Agricultural Biotechnology》 CAS 2023年第5期55-58,共4页
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g... [Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton. 展开更多
关键词 MUTTON High performance liquid chromatography-tandem mass spectrometry β-receptor agonist RESIDUE
下载PDF
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
18
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Determination on Heavy Metals Content of Achyranthes bidentata Blume. through Inductively Coupled Plasma Mass Spectrometry (ICP-MS) 被引量:4
19
作者 李宇伟 王新民 +3 位作者 连瑞丽 魏志华 介晓磊 陈士林 《Agricultural Science & Technology》 CAS 2008年第5期145-149,共5页
[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con... [Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places. 展开更多
关键词 MICROWAVE DIGESTION Inductively coupled plasma mass spectrometry(ICP-MS) Achyranthes bidentata Blume. HEAVY metal
下载PDF
Photoionization Mass Spectrometric and Kinetic Modeling of Low-pressure Pyrolysis of Benzene 被引量:2
20
作者 杨玖重 赵龙 +2 位作者 蔡江淮 齐飞 李玉阳 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2013年第3期245-251,I0003,共8页
Pyrolysis of benzene at 30 Torr was studied from 1360 K to 1820 K in this work. Synchrotron vacuum ultraviolet photoionization mass spectrometry was employed to detect the pyroly- sis products such as radicals, isomer... Pyrolysis of benzene at 30 Torr was studied from 1360 K to 1820 K in this work. Synchrotron vacuum ultraviolet photoionization mass spectrometry was employed to detect the pyroly- sis products such as radicals, isomers and polycyclic aromatic hydrocarbons, and measure their mole fraction profiles versus temperature. A low-pressure pyrolysis model of benzene was developed and validated by the experimental results. Rate of production analysis was performed to reveal the major reaction networks in both fuel decomposition and aromatic growth processes. It is concluded that benzene is mainly decomposed via H-abstraction reaction to produce phenyl and partly decomposed via unimolecular decomposition reac- tions to produce propargyl or phenyl. The decomposition process stops at the formation of acetylene and polyyne species like diacetylene and 1,3,5-hexatriyne due to their high thermal stabilities. Besides, the aromatic growth process in the low-pressure pyrolysis of benzene is concluded to initiate from benzene and phenyl, and is controlled by the even carbon growth mechanism due to the inhibited formation of C5 and C7 species which play important roles in the odd carbon growth mechanism. 展开更多
关键词 BENZENE Low-pressure pyrolysis PAH formation Synchrotron vacuum ultra-violet photoionization mass spectrometry Kinetic model
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部