As an efficient and energy-saving heat exchange technology, horizontal tube falling film evaporation has a great application prospect in refrigeration and air conditioning. The three-dimensional models of falling film...As an efficient and energy-saving heat exchange technology, horizontal tube falling film evaporation has a great application prospect in refrigeration and air conditioning. The three-dimensional models of falling film flow evaporation outside horizontal single tube and inside evaporator were established, and the accuracy of flow and heat transfer simulation process was verified by comparison. For horizontal single tube, the results showed that total heat transfer coefficient was low and increased with larger spray density and evaporation temperature. The thickness of liquid film outside tube decreased gradually with the increase of tube diameter, and the total heat transfer coefficient of small tube diameter was significantly greater than that of the large tube diameter. The total heat transfer coefficient presented an increasing trend with larger liquid distribution height and density. In addition, the fluctuation of tube axial liquid film thickness distribution decreased with larger liquid distribution density. For evaporator, the results indicated that part of liquid refrigerant was carried into the vapor outlet. The temperature of tube wall and fluid presented a gradually rising trend in vertical downward direction, while tube wall temperature within the same horizontal and transverse row had little difference. The high-temperature zone on the outer wall of heat exchange tube moved towards the inlet and gradually decreased, and the outlet temperature of water in the tube also gradually decreased with the increase of refrigerant spray density. The local heat transfer coefficient of heat exchanger tube in the vertical direction presented a downward trend which was more obvious with the smaller spray density and it was obviously higher located in the middle of upper tube row and both sides of lower tube row for horizontal tube rows.展开更多
A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distr...A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.展开更多
The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy ...The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant.展开更多
To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooli...To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooling technique.The design calculation of the porous ceramics tube type dew point indirect evaporative cooler are carried out from such aspects as the volumes and status parameters of the primary and secondary air,the cooler structure,the heat transfer of the solid porous ceramic tubes and the resistance of the cooler.The calculation results show that the design is reasonable.Finally,based on the design calculation,the porous ceramics tube type dew point indirect evaporative cooler is successfully manufactured.展开更多
The thermal resistances distribution in different wet-bulb temperatures, air velocities and spraying water densities were achieved by the experimental test. The fluctuation of the water film convection and the water-a...The thermal resistances distribution in different wet-bulb temperatures, air velocities and spraying water densities were achieved by the experimental test. The fluctuation of the water film convection and the water-air interfacial thermal resistance were reviewed especially. In the distribution of thermal resistance, the rank of the thermal resistance proportion (from max to min) is air flow heat transfer resistance, heat transfer resistance between refrigerant and wall, water film convection resistance and wall heat transfer resistance. When the heat flux is constant, the total resistance lowers nearly along with the increasing of air flow and water spray density. But there are a best air flow value of 2.98 m/s and a best spray water density of 0.064 kg/(m ·s) respectively, if continue to increase them, condensation performance is not significantly improved any more. The test results are available to improve the evaporative condenser performance and the designing lever.展开更多
基金financially supported by National Natural Science Foundation of China (No. 52006031)international cooperation project of China Manned Space Program (6903001173)。
文摘As an efficient and energy-saving heat exchange technology, horizontal tube falling film evaporation has a great application prospect in refrigeration and air conditioning. The three-dimensional models of falling film flow evaporation outside horizontal single tube and inside evaporator were established, and the accuracy of flow and heat transfer simulation process was verified by comparison. For horizontal single tube, the results showed that total heat transfer coefficient was low and increased with larger spray density and evaporation temperature. The thickness of liquid film outside tube decreased gradually with the increase of tube diameter, and the total heat transfer coefficient of small tube diameter was significantly greater than that of the large tube diameter. The total heat transfer coefficient presented an increasing trend with larger liquid distribution height and density. In addition, the fluctuation of tube axial liquid film thickness distribution decreased with larger liquid distribution density. For evaporator, the results indicated that part of liquid refrigerant was carried into the vapor outlet. The temperature of tube wall and fluid presented a gradually rising trend in vertical downward direction, while tube wall temperature within the same horizontal and transverse row had little difference. The high-temperature zone on the outer wall of heat exchange tube moved towards the inlet and gradually decreased, and the outlet temperature of water in the tube also gradually decreased with the increase of refrigerant spray density. The local heat transfer coefficient of heat exchanger tube in the vertical direction presented a downward trend which was more obvious with the smaller spray density and it was obviously higher located in the middle of upper tube row and both sides of lower tube row for horizontal tube rows.
基金supported by the open foundation of State Key Laboratory of Chemical Engineering (SKL-ChE-18B03)the Municipal Science and Technology Commission of Tianjin (No. 2009ZCKFGX01900)
文摘A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.
文摘The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant.
基金The National Natural Science Foundation of China(No.50846056)
文摘To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooling technique.The design calculation of the porous ceramics tube type dew point indirect evaporative cooler are carried out from such aspects as the volumes and status parameters of the primary and secondary air,the cooler structure,the heat transfer of the solid porous ceramic tubes and the resistance of the cooler.The calculation results show that the design is reasonable.Finally,based on the design calculation,the porous ceramics tube type dew point indirect evaporative cooler is successfully manufactured.
文摘The thermal resistances distribution in different wet-bulb temperatures, air velocities and spraying water densities were achieved by the experimental test. The fluctuation of the water film convection and the water-air interfacial thermal resistance were reviewed especially. In the distribution of thermal resistance, the rank of the thermal resistance proportion (from max to min) is air flow heat transfer resistance, heat transfer resistance between refrigerant and wall, water film convection resistance and wall heat transfer resistance. When the heat flux is constant, the total resistance lowers nearly along with the increasing of air flow and water spray density. But there are a best air flow value of 2.98 m/s and a best spray water density of 0.064 kg/(m ·s) respectively, if continue to increase them, condensation performance is not significantly improved any more. The test results are available to improve the evaporative condenser performance and the designing lever.