Influence of laser intensity in second-harmonic detection with tunable diode laser multi-pass absorption spectroscopy 被引量:9
1
作者 阚瑞峰 董凤忠 +5 位作者 张玉钧 刘建国 刘诚 王敏 高山虎 陈军 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第9期1904-1909,共6页
Tunable diode laser absorption spectroscopy (TDLAS) has been widely employed in atmospheric trace gases detection. The ratio of the second-harmonic signal to the intensity of laser beam incident to the multi-pass ce... Tunable diode laser absorption spectroscopy (TDLAS) has been widely employed in atmospheric trace gases detection. The ratio of the second-harmonic signal to the intensity of laser beam incident to the multi-pass cell is proved to be proportional to the product of the path length and the gas concentration under any condition. A new calibration method based on this relation in TDLAS system for the measurement of trace gas concentration is proposed for the first time. The detection limit and the sensitivity of the system are below 110 and 31ppbv (parts-per-billion in volume), respectively. 展开更多
关键词 tunable diode laser absorption spectroscopy multi-pass cell harmonic detection wavelength modulation
下载PDF
Measurements of argon metastable density using the tunable diode laser absorption spectroscopy in Ar and Ar/O2 被引量:1
2
作者 Dao-Man Han Yong-Xin Liu +3 位作者 Fei Gao Wen-Yao Liu Jun Xu You-Nian Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期298-306,共9页
Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate... Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate the effects of high-frequency(HF, 60 MHz) power, low-frequency(LF, 2 MHz) power, and working pressure on the density of Ar metastable states for three different gas components(0%, 5%, and 10% oxygen mixed in argon). The dependence of Ar metastable state density on the oxygen content is also studied at different working pressures. It is found that densities of Ar metastable states in discharges with different gas components exhibit different behaviors as HF power increases. With the increase of HF power, the metastable density increases rapidly at the initial stage, and then tends to be saturated at a higher HF power. With a small fraction(5% or 10%) of oxygen added in argon plasma, a similar change of the Ar metastable density with HF power can be observed, but the metastable density is saturated at a higher HF power than in the pure argon discharge. In the DF-CCP, the metastable density is found to be higher than in a single frequency discharge, and has weak dependence on LF power. As working pressure increases, the metastable state density first increases and then decreases,and the pressure value, at which the density maximum occurs, decreases with oxygen content increasing. Besides, adding a small fraction of oxygen into argon plasma will significantly dwindle the metastable state density as a result of quenching loss by oxygen molecules. 展开更多
关键词 argon metastable states tunable diode laser absorption spectroscopy capacitively coupled plasmas
下载PDF
Development of 2D Temperature and Concentration Measurement Method Using Tunable Diode Laser Absorption Spectroscopy 被引量:7
3
作者 Yoshihiro Deguchi Daisuke Yasui Akira Adachi 《Journal of Mechanics Engineering and Automation》 2012年第9期543-549,共7页
Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is int... Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is intrinsically a point temperature measurement method and noncontact 2D temperature distribution cannot be attained by thermocouples. Recently, as a measurement technique with high sensitivity and high response, laser diagnostics has been developed and applied to the actual engine combustions. With these engineering developments, transient phenomena such as start-ups and load changes in engines have been gradually elucidated in various conditions. In this study, the theoretical and experimental research has been conducted in order to develop the noncontact and fast response 2D temperature and concentration distribution measurement method. The method is based on a Computed Tomography (CT) method using absorption spectra of water vapor at 1388 nm. It has been demonstrated that the method has been successfully applied to engine exhausts to measure 2D temperature distributions. 展开更多
关键词 2D temperature measurement tunable diode laser absorption spectroscopy CT (computed tomography) engine exhausts.
下载PDF
Application of Tunable Diode Laser Absorption Spectroscopy with Optical Hollow Fiber to Engine Exhaust Gas Measurement
4
作者 Akira Adachi Yoshihiro Deguchi Shinichirou Konishi 《Journal of Mechanics Engineering and Automation》 2012年第11期656-662,共7页
In recent years, tighter regulation has been already enforced on harmful substances such as NOx, CO, and particles. Considering the above situation, it is important to monitor controlling factors of engine systems in ... In recent years, tighter regulation has been already enforced on harmful substances such as NOx, CO, and particles. Considering the above situation, it is important to monitor controlling factors of engine systems in order to improve efficiencies of their operations. As to car engines, an increasing concern in environmental issues such as air pollution, global warming and petroleum depletion has helped drive researches into various ways. Laser diagnostics has been applied to measure species concentration in the actual industrial fields. However there are several challenges to proceed in applying laser diagnostics to practical application. Especially stability of the measurement system is one of the most difficult issues. The purpose of this research is the development of a prompt measurement technique which can be applicable to various engine conditions. The Tunable Diode Laser Absorption Spectroscopy (TDLAS) using the hollow fiber has been developed to satisfy above requirements. By using a hollow fiber, misalignment of an optical axis and vulnerability of measurement environment such as vibration can be greatly reduced with sensitive and fast response features. It was demonstrated that this method can be applicable to measure gas compositions in engine exhaust with a range of millisecond response time. A sensitive method using tunable UV diode laser absorption spectroscopy was also discussed to detect NOx in exhausts. 展开更多
关键词 tunable diode laser absorption spectroscopy optical hollow fiber exhaust gas concentration measurement.
下载PDF
基于TDLAS的近红外甲烷高灵敏检测技术 被引量:1
5
作者 刘海芹 徐睿 +4 位作者 王振翔 赵天琦 赵春柳 石岩 陈亮 《光子学报》 EI CAS CSCD 北大核心 2024年第3期243-250,共8页
为增强甲烷气体检测技术的气体吸收率,提高检测灵敏度,利用可调谐二极管激光吸收光谱技术,采用中心波长为1 653.7 nm的分布反馈激光器作为光源,研制了有效光程为14.5 m的Herriott型气体吸收池,并采用波长调制光谱法进行甲烷气体浓度检... 为增强甲烷气体检测技术的气体吸收率,提高检测灵敏度,利用可调谐二极管激光吸收光谱技术,采用中心波长为1 653.7 nm的分布反馈激光器作为光源,研制了有效光程为14.5 m的Herriott型气体吸收池,并采用波长调制光谱法进行甲烷气体浓度检测。结果表明,二次谐波峰值信号与甲烷气体浓度成较强的线性关系,线性度为0.998 52,检测下限为4.82 ppm;初始积分时间为1 s时的Allan方差为6.37 ppm;积分时间到112 s时,Allan方差为427 ppb,检测灵敏度为4.27×10^(-7)。 展开更多
关键词 可调谐二极管激光吸收光谱 甲烷气体检测 波长调制法 高灵敏 Herriott腔
下载PDF
基于TDLAS的高温氧气标定方法研究
6
作者 黄小东 郝晓剑 +3 位作者 梁晓东 王正 裴攀 王佳 《传感器与微系统》 CSCD 北大核心 2024年第5期43-46,共4页
燃烧场温度的准确测量是评价燃烧状况的重要指标。可调谐二极管激光吸收光谱(TDLAS)技术是一种有效的非接触式燃烧诊断方法,其具有更广的测量范围、高精度和良好的抗干扰性能,且能实现连续测量。然而,在高分辨率透射分子吸收数据库(HITR... 燃烧场温度的准确测量是评价燃烧状况的重要指标。可调谐二极管激光吸收光谱(TDLAS)技术是一种有效的非接触式燃烧诊断方法,其具有更广的测量范围、高精度和良好的抗干扰性能,且能实现连续测量。然而,在高分辨率透射分子吸收数据库(HITRAN)中光谱数据都是以296 K的谱线参数为基础,通过计算获得较高温度下的光谱数据。因此,本文利用TDLAS波长调制技术标定了高温场中O_(2)的二次谐波信号强度与温度的函数关系,为后续燃烧场温度测量实验奠定基础。 展开更多
关键词 可调谐二极管激光吸收光谱 波长调制技术 燃烧场
下载PDF
基于改进VMD算法的TDLAS甲烷检测信号降噪研究
7
作者 唐奇超 王强 +2 位作者 洪志明 谷小红 肖瑶 《中国计量大学学报》 2024年第1期35-42,共8页
目的:提出一种北方苍鹰优化(NGO)改进变分模态分解(VMD)的降噪算法,以抑制基于可调谐半导体激光吸收光谱(TDLAS)的甲烷检测系统中的噪声。方法:首先基于MATLAB仿真了二次谐波信号,随后分别用VMD算法和NGO-VMD算法对二次谐波信号进行降噪... 目的:提出一种北方苍鹰优化(NGO)改进变分模态分解(VMD)的降噪算法,以抑制基于可调谐半导体激光吸收光谱(TDLAS)的甲烷检测系统中的噪声。方法:首先基于MATLAB仿真了二次谐波信号,随后分别用VMD算法和NGO-VMD算法对二次谐波信号进行降噪,并用信噪比(SNR)、均方根误差(RMSE)和相关性系数(PCC)对两种方法进行性能对比。结果:经NGO-VMD算法重构后的信号信噪比较之原信号提升约2倍,均方根误差减少97%,相关系数高达0.997。结论:所提出的NGO-VMD算法较于传统的VMD算法在各项指标上均有明显优势,提升了TDLAS甲烷检测系统的信噪比。 展开更多
关键词 可调谐半导体激光吸收光谱 北方苍鹰优化 变分模态分解 降噪
下载PDF
Laser absorption spectroscopy for high temperature H_2O time-history measurement at 2.55 μm during oxidation of hydrogen
8
作者 Yu-Dan Gou De-Xiang Zhang +3 位作者 Yi-Jun Wang Chang-Hua Zhang Ping Li Xiang-Yuan Li 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期376-381,共6页
Concentration time-histories of H20 were measured behind reflected shock waves during hydrogen combustion. Experiments were conducted at temperatures of 1117-1282 K, the equivalence ratios of 0.5 and 0.25, and a press... Concentration time-histories of H20 were measured behind reflected shock waves during hydrogen combustion. Experiments were conducted at temperatures of 1117-1282 K, the equivalence ratios of 0.5 and 0.25, and a pressure at 2 atm using a mixture of H2/O2 highly diluted with argon. H2O was monitored using tunable mid-infrared diode laser absorption at 2.55 μm (3920.09 cm-1). These time-histories provide kinetic targets to test and refine reaction mechanisms for hydrogen. Comparisons were made with the predictions of four detailed kinetic mechanisms published in the last four years. Such comparisons of H2O concentration profiles indicate that the AramcoMech 2.0 mechanism yields the best agreement with the experimental data, while CRECK, San Diego, and HP-Mech mechanisms show significantly poor predictions. Reaction pathway analysis for hydrogen oxidation indicates that the reaction H + OH + M = H20 + M is the key reaction for controlling the H2O formation by hydrogen oxidation. It is inferred that the discrepancy of the conversion percentage from H to H20 among these four mechanisms induces the difference of performance on H2O time-history predictions. This work demonstrates the potential of time-history measurement for validation of large reaction mechanisms. 展开更多
关键词 tunable diode laser absorption spectroscopy H20 time-history profile combustion process reac- tion mechanism
下载PDF
改善的LMS自适应算法在TDLAS甲烷检测的降噪研究
9
作者 陈新玉 陈红岩 《激光杂志》 CAS 北大核心 2024年第5期79-85,共7页
为进一步有效抑制检测系统的噪声,提高检测精度,研究了改善的最小均方差自适应算法在可调谐二极管激光吸收光谱甲烷浓度检测系统的降噪方法。通过基于TDLAS技术的matlab仿真实验,搭建的甲烷检测系统,选取1 653.72 nm的甲烷吸收峰位,分析... 为进一步有效抑制检测系统的噪声,提高检测精度,研究了改善的最小均方差自适应算法在可调谐二极管激光吸收光谱甲烷浓度检测系统的降噪方法。通过基于TDLAS技术的matlab仿真实验,搭建的甲烷检测系统,选取1 653.72 nm的甲烷吸收峰位,分析LMS自适应算法中滤波阶数、步长因子和采样周期三者对噪声的关系,改善参数的选取以最佳的滤波效果进行降噪优化处理。研究表明在高频采样时刻收敛到最佳的滤波阶数和步长因子可对系统起到最优滤波效果。研究结果显示信噪比有效提升了94%,拟合优度R~2达到0.997,证明改善的LMS自适应滤波算法可以有效抑制噪声对二次谐波信号的影响。 展开更多
关键词 改善的最小均方差自适应算法 可调谐二极管激光吸收光谱技术 降噪处理 二次谐波信号
下载PDF
基于TDLAS的变压器油中C_(2)H_(2)在线监测装置设计
10
作者 曹旺 万元 +4 位作者 唐伟 刘章进 李橙橙 廖学顺 吴昊天 《农村电气化》 2024年第2期61-64,共4页
随着电力行业的不断发展,变压器的安全与稳定愈发重要。为满足变压器油中C_(2)H_(2)的在线监测需要,选取1532 nm的分布式半导体激光器与12 m光程怀特池,研制了基于可调谐二极管激光吸收光谱技术与波长调制技术的变压器油中C_(2)H_(2)在... 随着电力行业的不断发展,变压器的安全与稳定愈发重要。为满足变压器油中C_(2)H_(2)的在线监测需要,选取1532 nm的分布式半导体激光器与12 m光程怀特池,研制了基于可调谐二极管激光吸收光谱技术与波长调制技术的变压器油中C_(2)H_(2)在线监测装置,实现了油中溶解C_(2)H_(2)分离、气体检测、结果分析等功能,测量周期约为25 min,测试过程无损样本。该装置检测精准快速,无需人工操作,可为变压器提供实时的安全参考意见。 展开更多
关键词 变压器油 C_(2)H_(2) 可调谐二极管激光吸收光谱 波长调制 在线监测
下载PDF
Dynamic thermal modeling and parameter identification for a monolithic laser diode module
11
作者 李金义 杜振辉 +1 位作者 马艺闻 徐可欣 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第3期317-322,共6页
We improved the thermal equivalent-circuit model of the laser diode module(LDM) to evaluate its thermal dynamic properties and calculate the junction temperature of the laser diode with a high accuracy.The thermal p... We improved the thermal equivalent-circuit model of the laser diode module(LDM) to evaluate its thermal dynamic properties and calculate the junction temperature of the laser diode with a high accuracy.The thermal parameters and the transient junction temperature of the LDM are modeled and obtained according to the temperature of the thermistor integrated in the module.Our improved thermal model is verified indirectly by monitoring the emission wavelength of the laser diode against gas absorption lines,and several thermal parameters are obtained with the temperature uncertainty of 0.01 K in the thermal dynamic process. 展开更多
关键词 laser diode module dynamic thermal modeling thermal time constant tunable diode laser absorption spectroscopytdlas
下载PDF
基于TDLAS技术的一氧化碳检测系统设计
12
作者 曹旺 万元 李橙橙 《中国测试》 CAS 北大核心 2023年第S01期215-219,共5页
为满足工业生产过程中的一氧化碳检测需要,研制基于可调谐半导体激光吸收光谱(TDLAS)技术的一氧化碳检测系统。通过分析近红外波段的一氧化碳吸收谱线,选取1567.3nm作为激光器的扫描中心波长,设计系统的气路控制、光学检测与声光报警模... 为满足工业生产过程中的一氧化碳检测需要,研制基于可调谐半导体激光吸收光谱(TDLAS)技术的一氧化碳检测系统。通过分析近红外波段的一氧化碳吸收谱线,选取1567.3nm作为激光器的扫描中心波长,设计系统的气路控制、光学检测与声光报警模块,开发基于FPGA数字锁相放大器的二次谐波解调算法,并采用最小二乘法建立浓度特征值关系曲线,实现一氧化碳的高精度检测。实验表明:该系统检测速度快,抗干扰能力强,能在恶劣的环境中正常工作,检测下限可至10μL/L,与实际浓度的误差在2%左右,具有较高的实用价值。 展开更多
关键词 一氧化碳 调谐半导体激光吸收光谱技术 数字锁相放大器 二次谐波
下载PDF
基于TDLAS的增强型气体检测新技术
13
作者 唐伟 马云鹂 +2 位作者 袁艺朗 张毅 古冉 《石油化工自动化》 CAS 2023年第4期81-84,共4页
可调谐半导体激光吸收光谱技术(TDLAS)是一种在二极管激光器波长调制与长光程吸收池技术相结合的基础上发展起来的新型气体检测方法。介绍了TDLAS技术的工作原理,并列举了其固有的技术缺陷,以及因此导致的在石化行业中的应用限制。通过... 可调谐半导体激光吸收光谱技术(TDLAS)是一种在二极管激光器波长调制与长光程吸收池技术相结合的基础上发展起来的新型气体检测方法。介绍了TDLAS技术的工作原理,并列举了其固有的技术缺陷,以及因此导致的在石化行业中的应用限制。通过对比分析增强型激光二极管吸收频谱技术(ELDS)和TDLAS的应用表明,ELDS技术克服了TDLAS的技术缺陷和应用限制,能够实现对于可燃性碳氢类化合物和蒸气,以及多种有毒有害气体进行快速、高精度、高选择性地在线检测,真正实现零误报、零漏报、零维护。 展开更多
关键词 可调谐半导体激光吸收光谱 增强型激光二极管吸收频谱 激光 自校准 气体检测
下载PDF
基于VisuShrink小波阈值变换的甲烷检测降噪技术
14
作者 姜建国 胡钧凯 王秀芳 《化工自动化及仪表》 CAS 2024年第3期410-416,共7页
在利用可调谐半导体激光吸收光谱技术探测甲烷气体泄漏时,复杂的环境光干扰会降低浓度检测信号的信噪比使波形失真。为了抑制噪声,增强电信号与浓度值的线性相关度,提出一种以VisuShrink方法改善小波阈值函数的小波阈值去噪算法。该算... 在利用可调谐半导体激光吸收光谱技术探测甲烷气体泄漏时,复杂的环境光干扰会降低浓度检测信号的信噪比使波形失真。为了抑制噪声,增强电信号与浓度值的线性相关度,提出一种以VisuShrink方法改善小波阈值函数的小波阈值去噪算法。该算法针对小波阈值去噪算法的软硬度不能平衡信号,存在失真的问题,利用统计方法对阈值进行计算,弱化间断点阈值跳变影响。通过仿真计算对比未加噪声前的信号与滤波后的信号,提出算法的信噪比为28.405 30,优于四阶巴特沃斯滤波器。VisuShrink方法在SNR和NCC参数上性能远优于巴特沃斯滤波器,与软阈值函数相近,在MSE均方误差分析上远小于软阈值精度,与巴特沃斯相近,具有较好的平滑特性。实际搭建检测平台对多个浓度样本采样进行多次采样,采用VisuShrink方法设计的滤波器将系统误差精度从4.14%提升至2.472%,算法可有效用于甲烷检测系统提高光谱数据的平滑性和准确性。 展开更多
关键词 可调谐半导体激光吸收光谱 气体浓度测量 波长调制光谱技术 小波阈值去噪 甲烷泄漏
下载PDF
数字滤波方法在TDLAS逃逸氨检测中的选用 被引量:19
15
作者 邹得宝 陈文亮 +6 位作者 杜振辉 贾浩 齐汝宾 李红莲 甄杨 侯艳霞 徐可欣 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2012年第9期2322-2326,共5页
介绍了可调谐半导体激光吸收光谱技术(TDLAS)原理和实验系统,并对系统噪声进行了分析;以体积比浓度为90×10-6和30×10-6的NH3为例,利用TDLAS系统采集了该浓度气体的二次谐波原始光谱。为改善光谱信号,分别用五种数字滤波方法... 介绍了可调谐半导体激光吸收光谱技术(TDLAS)原理和实验系统,并对系统噪声进行了分析;以体积比浓度为90×10-6和30×10-6的NH3为例,利用TDLAS系统采集了该浓度气体的二次谐波原始光谱。为改善光谱信号,分别用五种数字滤波方法对原始光谱进行了滤波处理比较,做了NH3的浓度梯度实验并对浓度为20×10-6 NH3进行了长时间监测实验。实验结果表明,算术平均-小波变换滤波相比其他方法更有效地对原始光谱信号进行了改善,提高了系统信噪比和信号平滑度,使系统浓度检测限由原来的10×10-6降低到1.25×10-6,信噪比提高了约14倍,为逃逸氨极低浓度检测提供了一种较为有效的数据预处理方法。 展开更多
关键词 可调谐激光吸收光谱(tdlas) 逃逸氨检测 噪声分析 数字滤波 小波变换
下载PDF
高温高压下基于TDLAS的二氧化碳浓度测量方法研究 被引量:13
16
作者 蔡廷栋 高光珍 +2 位作者 王敏锐 王贵师 高晓明 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2014年第7期1769-1773,共5页
通过具有高灵敏度、非侵入式等特性的可调谐二极管激光吸收光谱技术对发动机气缸工作过程等高温高压燃烧环境进行实时在线检测,是了解其内部燃烧过程进而研发高效发动机的重要手段之一。作为一种重要的温室气体和化石燃料燃烧的主要产物... 通过具有高灵敏度、非侵入式等特性的可调谐二极管激光吸收光谱技术对发动机气缸工作过程等高温高压燃烧环境进行实时在线检测,是了解其内部燃烧过程进而研发高效发动机的重要手段之一。作为一种重要的温室气体和化石燃料燃烧的主要产物,二氧化碳对于了解燃烧过程具有重要的意义。为了寻找一种能够对高温高压燃烧过程中的二氧化碳浓度进行快速检测的方法,利用工作在室温条件下的近红外可调谐二极管激光器作为光源,以二氧化碳位于5 006.140cm-1处的跃迁作为传感谱线,结合固定波长的吸收光谱调制技术,通过该CO2谱线的一次谐波归一化的二次谐波信号峰值实现对高温高压环境中CO2浓度测量,建立了一种可用于高温高压环境下的组份浓度的测量方法,通过实验验证得出该方法在5atm压力、500K温度下和10atm压力、1 000K温度下对于CO2浓度测量的平均标准偏差为3.99%;另外还对实验中所得CO2直接吸收及二次谐波信号进行了分析,得到了其吸收光谱在高温高压环境下的特性。 展开更多
关键词 可调谐二极管激光吸收光谱 波长调制光谱 高温高压 二氧化碳浓度
下载PDF
小型化中红外直接吸收CO_(2)光谱仪
17
作者 刘婧怡 潘越 +3 位作者 姚路 于丽婷 李惠 阚瑞峰 《光学精密工程》 EI CAS CSCD 北大核心 2024年第9期1330-1337,共8页
二氧化碳(Carbon Dioxide,CO_(2))是一种关键的温室气体,对地球气候和生态系统调节有重要作用,准确检测痕量CO_(2)浓度对评价温室效应意义重大。一般情况下,气体分子在中红外光谱范围存在强吸收,可以实现高灵敏探测,因此,以4.219μm中... 二氧化碳(Carbon Dioxide,CO_(2))是一种关键的温室气体,对地球气候和生态系统调节有重要作用,准确检测痕量CO_(2)浓度对评价温室效应意义重大。一般情况下,气体分子在中红外光谱范围存在强吸收,可以实现高灵敏探测,因此,以4.219μm中红外波段的带间级联激光器为光源结合可调谐半导体激光吸收光谱技术(Tunable Diode Laser Absorption Spectroscopy,TDLAS)设计了小型化CO_(2)监测仪器。在不同标气浓度下对仪器进行了标定,并通过分析Allan方差,得出积分时间在8.7 s时对应的最低检测限为16.6×10^(-9),满足温室效应研究对CO_(2)气体的高灵敏测量需求。采用仪器对大气CO_(2)连续监测8天,并与商用仪器LGR进行对比,充分验证了小型化CO_(2)监测仪器的可靠性,以及中红外光源与TDLAS技术相结合的气体浓度检测方法在大气CO_(2)准确测量方面的可行性。该系统具有结构简单、体积小、功耗低和质量轻的特点,为建设空基无人机平台的CO_(2)监测能力提供了技术支持。 展开更多
关键词 激光吸收光谱技术 二氧化碳 中红外可调谐二极管激光 直接吸收 小型化
下载PDF
基于TDLAS技术同时检测卷烟主流烟气中的CO和CO_2 被引量:17
18
作者 邢昆明 杨柯 +5 位作者 张龙 吴晓松 李志刚 王安 刘勇 计敏 《量子电子学报》 CAS CSCD 北大核心 2017年第1期81-87,共7页
基于可调谐二极管激光吸收光谱(TDLAS)技术、波长调制技术和二次谐波检测方法,利用CO和CO_2在1579 nm处的泛频吸收特征,结合改造后的单孔道吸烟机,建立了卷烟主流烟气逐口检测系统。实验结果表明:气体浓度与其二次谐波强度的线性度较好... 基于可调谐二极管激光吸收光谱(TDLAS)技术、波长调制技术和二次谐波检测方法,利用CO和CO_2在1579 nm处的泛频吸收特征,结合改造后的单孔道吸烟机,建立了卷烟主流烟气逐口检测系统。实验结果表明:气体浓度与其二次谐波强度的线性度较好,系统响应速度较快,精度能达到检测要求,逐口检测稳定性、重复性和灵敏度均较好。同类型卷烟主流烟气中CO、CO_2的逐口释放量除第1口之外,均呈递增趋势,CO_2的逐口释放量和递增速率均比CO的大,且不同类型的卷烟遵循相同的规律。所建系统具有检测速度快、时间分辨率高、结构简单等优势,在卷烟烟气有害物质的快速检测领域具有较好的应用前景。 展开更多
关键词 光谱学 同时检测 可调谐二极管激光吸收光谱 卷烟烟气 CO CO2
下载PDF
基于TDLAS技术的水汽低温吸收光谱参数测量 被引量:18
19
作者 聂伟 阚瑞峰 +5 位作者 许振宇 姚路 夏晖晖 彭于权 张步强 何亚柏 《物理学报》 SCIE EI CAS CSCD 北大核心 2017年第20期91-96,共6页
精确的气体光谱参数对气体浓度、温度等的光谱精确反演测量具有十分重要的意义,针对当前主流光谱数据库(例如HITRAN)中数据与实际数值存在相当误差的问题,自主研制了一套基于静态冷却技术的低温光谱实验平台,用于精确测量低温下的气体... 精确的气体光谱参数对气体浓度、温度等的光谱精确反演测量具有十分重要的意义,针对当前主流光谱数据库(例如HITRAN)中数据与实际数值存在相当误差的问题,自主研制了一套基于静态冷却技术的低温光谱实验平台,用于精确测量低温下的气体吸收光谱参数.运用该低温光谱实验平台,采用可调谐二极管激光吸收光谱(TDLAS)技术测量了温度为230—340 K、压强为10—1000 Pa时7240—7246 cm^(-1)波段的纯水汽振转跃迁光谱.采用Voigt线型多峰拟合方法,获得了5条水汽振转跃迁谱在不同温度、不同压强下的积分吸光度值及洛伦兹展宽值,运用线性拟合的方法得到这5条吸收线的自展宽半峰全宽系数及参考温度下的线强值.运用不确定度传递公式,计算得到实验结果的不确定度,与HITRAN2012数据库中的线参数进行对比,所测的5条吸收线中实验结果与数据库值最大相差10.96%,且实验结果的不确定度为1.11%—2.98%(置信概率p=95%,包含因子k=2),小于HITRAN2012数据库值的不确定度. 展开更多
关键词 可调谐二极管激光器 吸收光谱 水汽 线强 自展宽系数
下载PDF
基于TDLAS的城市天然气管道泄漏检测系统 被引量:11
20
作者 祝玉泉 乔利峰 +3 位作者 张启兴 蔡廷力 王进军 张永明 《中国科学技术大学学报》 CAS CSCD 北大核心 2009年第4期429-434,共6页
将TDLAS(tunable diode laser absorption spectroscopy)技术应用于城市天然气管道泄漏检测及定位.阐述了天然气管道泄漏检测系统的设计原理,介绍了所选用的二极管激光器和多次反射吸收池的特性.实验测量给出了二极管激光器最优的参数设... 将TDLAS(tunable diode laser absorption spectroscopy)技术应用于城市天然气管道泄漏检测及定位.阐述了天然气管道泄漏检测系统的设计原理,介绍了所选用的二极管激光器和多次反射吸收池的特性.实验测量给出了二极管激光器最优的参数设置,得到了系统的最低检测限(2.7×10-6)、线性响应度和系统换气速率(9.3~11.3次/min),运用数值模拟方法得到了天然气管道泄漏后气体浓度沿管道的分布情况,提出了对天然气管道泄漏定位的方法. 展开更多
关键词 tdlas 天然气 泄漏检测
下载PDF