Influence of laser intensity in second-harmonic detection with tunable diode laser multi-pass absorption spectroscopy 被引量:9
1
作者 阚瑞峰 董凤忠 +5 位作者 张玉钧 刘建国 刘诚 王敏 高山虎 陈军 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第9期1904-1909,共6页
Tunable diode laser absorption spectroscopy (TDLAS) has been widely employed in atmospheric trace gases detection. The ratio of the second-harmonic signal to the intensity of laser beam incident to the multi-pass ce... Tunable diode laser absorption spectroscopy (TDLAS) has been widely employed in atmospheric trace gases detection. The ratio of the second-harmonic signal to the intensity of laser beam incident to the multi-pass cell is proved to be proportional to the product of the path length and the gas concentration under any condition. A new calibration method based on this relation in TDLAS system for the measurement of trace gas concentration is proposed for the first time. The detection limit and the sensitivity of the system are below 110 and 31ppbv (parts-per-billion in volume), respectively. 展开更多
关键词 tunable diode laser absorption spectroscopy multi-pass cell harmonic detection wavelength modulation
下载PDF
Measurements of argon metastable density using the tunable diode laser absorption spectroscopy in Ar and Ar/O2 被引量:1
2
作者 韩道满 刘永新 +3 位作者 高飞 刘文耀 徐军 王友年 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期298-306,共9页
Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate... Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate the effects of high-frequency(HF, 60 MHz) power, low-frequency(LF, 2 MHz) power, and working pressure on the density of Ar metastable states for three different gas components(0%, 5%, and 10% oxygen mixed in argon). The dependence of Ar metastable state density on the oxygen content is also studied at different working pressures. It is found that densities of Ar metastable states in discharges with different gas components exhibit different behaviors as HF power increases. With the increase of HF power, the metastable density increases rapidly at the initial stage, and then tends to be saturated at a higher HF power. With a small fraction(5% or 10%) of oxygen added in argon plasma, a similar change of the Ar metastable density with HF power can be observed, but the metastable density is saturated at a higher HF power than in the pure argon discharge. In the DF-CCP, the metastable density is found to be higher than in a single frequency discharge, and has weak dependence on LF power. As working pressure increases, the metastable state density first increases and then decreases,and the pressure value, at which the density maximum occurs, decreases with oxygen content increasing. Besides, adding a small fraction of oxygen into argon plasma will significantly dwindle the metastable state density as a result of quenching loss by oxygen molecules. 展开更多
关键词 argon metastable states tunable diode laser absorption spectroscopy capacitively coupled plasmas
下载PDF
Development of 2D Temperature and Concentration Measurement Method Using Tunable Diode Laser Absorption Spectroscopy 被引量:7
3
作者 Yoshihiro Deguchi Daisuke Yasui Akira Adachi 《Journal of Mechanics Engineering and Automation》 2012年第9期543-549,共7页
关键词 可调谐二极管激光吸收光谱 温度分布 测量方法 浓度分布 二维 发动机效率 计算机断层扫描 非接触式
下载PDF
Application of Tunable Diode Laser Absorption Spectroscopy with Optical Hollow Fiber to Engine Exhaust Gas Measurement
4
作者 Akira Adachi Yoshihiro Deguchi Shinichirou Konishi 《Journal of Mechanics Engineering and Automation》 2012年第11期656-662,共7页
关键词 可调谐二极管激光吸收光谱 发动机排气 光学测量 中空纤维 应用 氮氧化物 激光诊断 发动机系统
下载PDF
基于TDLAS的近红外甲烷高灵敏检测技术
5
作者 刘海芹 徐睿 +4 位作者 王振翔 赵天琦 赵春柳 石岩 陈亮 《光子学报》 EI CAS CSCD 北大核心 2024年第3期243-250,共8页
为增强甲烷气体检测技术的气体吸收率,提高检测灵敏度,利用可调谐二极管激光吸收光谱技术,采用中心波长为1 653.7 nm的分布反馈激光器作为光源,研制了有效光程为14.5 m的Herriott型气体吸收池,并采用波长调制光谱法进行甲烷气体浓度检... 为增强甲烷气体检测技术的气体吸收率,提高检测灵敏度,利用可调谐二极管激光吸收光谱技术,采用中心波长为1 653.7 nm的分布反馈激光器作为光源,研制了有效光程为14.5 m的Herriott型气体吸收池,并采用波长调制光谱法进行甲烷气体浓度检测。结果表明,二次谐波峰值信号与甲烷气体浓度成较强的线性关系,线性度为0.998 52,检测下限为4.82 ppm;初始积分时间为1 s时的Allan方差为6.37 ppm;积分时间到112 s时,Allan方差为427 ppb,检测灵敏度为4.27×10^(-7)。 展开更多
关键词 可调谐二极管激光吸收光谱 甲烷气体检测 波长调制法 高灵敏 Herriott腔
下载PDF
A 1550-nm linearly tunable continuous wave single-mode external cavity diode laser based on a single-cavity all-dielectric thin-film Fabry Pérot filter
6
作者 肖啸 鲁远甫 +1 位作者 于峰崎 金雷 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期533-541,共9页
A 1550-nm linearly tunable continuous wave (CW) single-mode external cavity diode laser (ECDL) based on a singlecavity all-dielectric thin-film Fabry-Pérot filter (s-AFPF) is proposed and realized in this p... A 1550-nm linearly tunable continuous wave (CW) single-mode external cavity diode laser (ECDL) based on a singlecavity all-dielectric thin-film Fabry-Pérot filter (s-AFPF) is proposed and realized in this paper. Its internal optical components as well as their operation mechanisms are introduced first, and then its longitudinal mode output characteristic is theoretically analyzed. Afterwards, we set up the experimental platform for the output characteristic measurement of this tunable ECDL; under different experimental conditions, we execute accurate and real-time measurements for the output central wavelength, output optical power, output longitudinal mode distribution, and the line-width of the tunable ECDL in its tuning process. By summing up the optimal experimental condition from the measured data, we obtain the optimal tunable ECDL relevant parameters: the tunable ECDL has a linear mode-hop-free wavelength tuning region of 1547.203 nm-1552.426 nm, a stable output optical power in the range of 40 μW-50 μW, and a stable output longitudinal mode distribution of a single longitudinal mode with a line-width in the range of 100 MHz-150 MHz. This tunable ECDL can be used in environmental gas monitoring, atomic and molecular laser spectroscopy research, precise measurements, and so on. 展开更多
关键词 thin-film optical properties tunable external cavity diode laser laser spectroscopy
下载PDF
基于TDLAS的高温氧气标定方法研究
7
作者 黄小东 郝晓剑 +3 位作者 梁晓东 王正 裴攀 王佳 《传感器与微系统》 CSCD 北大核心 2024年第5期43-46,共4页
燃烧场温度的准确测量是评价燃烧状况的重要指标。可调谐二极管激光吸收光谱(TDLAS)技术是一种有效的非接触式燃烧诊断方法,其具有更广的测量范围、高精度和良好的抗干扰性能,且能实现连续测量。然而,在高分辨率透射分子吸收数据库(HITR... 燃烧场温度的准确测量是评价燃烧状况的重要指标。可调谐二极管激光吸收光谱(TDLAS)技术是一种有效的非接触式燃烧诊断方法,其具有更广的测量范围、高精度和良好的抗干扰性能,且能实现连续测量。然而,在高分辨率透射分子吸收数据库(HITRAN)中光谱数据都是以296 K的谱线参数为基础,通过计算获得较高温度下的光谱数据。因此,本文利用TDLAS波长调制技术标定了高温场中O_(2)的二次谐波信号强度与温度的函数关系,为后续燃烧场温度测量实验奠定基础。 展开更多
关键词 可调谐二极管激光吸收光谱 波长调制技术 燃烧场
下载PDF
基于改进VMD算法的TDLAS甲烷检测信号降噪研究
8
作者 唐奇超 王强 +2 位作者 洪志明 谷小红 肖瑶 《中国计量大学学报》 2024年第1期35-42,共8页
目的:提出一种北方苍鹰优化(NGO)改进变分模态分解(VMD)的降噪算法,以抑制基于可调谐半导体激光吸收光谱(TDLAS)的甲烷检测系统中的噪声。方法:首先基于MATLAB仿真了二次谐波信号,随后分别用VMD算法和NGO-VMD算法对二次谐波信号进行降噪... 目的:提出一种北方苍鹰优化(NGO)改进变分模态分解(VMD)的降噪算法,以抑制基于可调谐半导体激光吸收光谱(TDLAS)的甲烷检测系统中的噪声。方法:首先基于MATLAB仿真了二次谐波信号,随后分别用VMD算法和NGO-VMD算法对二次谐波信号进行降噪,并用信噪比(SNR)、均方根误差(RMSE)和相关性系数(PCC)对两种方法进行性能对比。结果:经NGO-VMD算法重构后的信号信噪比较之原信号提升约2倍,均方根误差减少97%,相关系数高达0.997。结论:所提出的NGO-VMD算法较于传统的VMD算法在各项指标上均有明显优势,提升了TDLAS甲烷检测系统的信噪比。 展开更多
关键词 可调谐半导体激光吸收光谱 北方苍鹰优化 变分模态分解 降噪
下载PDF
基于TDLAS的气体检测技术对比与分析
9
作者 柳山虎 吴勇 +3 位作者 梁立振 谢亚红 韦江龙 胡纯栋 《计量与测试技术》 2024年第4期35-39,共5页
根据可调谐半导体激光吸收光谱(TDLAS)技术测量气体浓度的基本原理,对三种主要测量方法,即直接吸收光谱技术(DAS)、波长调制技术(WMS)、频率调制光谱技术(FMS)进行详细分析,并根据TDLAS技术的应用情况,分别将系统组成、技术要点、检测... 根据可调谐半导体激光吸收光谱(TDLAS)技术测量气体浓度的基本原理,对三种主要测量方法,即直接吸收光谱技术(DAS)、波长调制技术(WMS)、频率调制光谱技术(FMS)进行详细分析,并根据TDLAS技术的应用情况,分别将系统组成、技术要点、检测极限、系统成本和适用环境进行对比分析。 展开更多
关键词 可调谐半导体激光吸收光谱 气体检测 检测限
下载PDF
基于TDLAS甲烷检测系统的长光程池研究与设计
10
作者 秦雨婷 陈红岩 《激光与红外》 CAS CSCD 北大核心 2024年第4期522-528,共7页
采用Herriott型长光程池结构原理,通过理论研究和仿真分析得到一定条件下Herriott池反射次数最优解,利用镀膜凹面镜作为反射镜,在池体上集成光学元件,进行了长光程、低成本、小体积光程池的设计。经过实验验证,所设计的物理长23cm,体积2... 采用Herriott型长光程池结构原理,通过理论研究和仿真分析得到一定条件下Herriott池反射次数最优解,利用镀膜凹面镜作为反射镜,在池体上集成光学元件,进行了长光程、低成本、小体积光程池的设计。经过实验验证,所设计的物理长23cm,体积243mL的光程池,能达到11m有效光程长,并搭建在TDLAS甲烷检测系统中,结果表明检测下限最低浓度为476 ppb。这为低浓度、高精度、微型化的TDLAS甲烷检测系统的推广应用提供了一种有效的途径。 展开更多
关键词 赫里奥特气室 光学仿真 可调谐激光吸收光谱 甲烷检测
下载PDF
基于TDLAS的变压器油中C_(2)H_(2)在线监测装置设计
11
作者 曹旺 万元 +4 位作者 唐伟 刘章进 李橙橙 廖学顺 吴昊天 《农村电气化》 2024年第2期61-64,共4页
随着电力行业的不断发展,变压器的安全与稳定愈发重要。为满足变压器油中C_(2)H_(2)的在线监测需要,选取1532 nm的分布式半导体激光器与12 m光程怀特池,研制了基于可调谐二极管激光吸收光谱技术与波长调制技术的变压器油中C_(2)H_(2)在... 随着电力行业的不断发展,变压器的安全与稳定愈发重要。为满足变压器油中C_(2)H_(2)的在线监测需要,选取1532 nm的分布式半导体激光器与12 m光程怀特池,研制了基于可调谐二极管激光吸收光谱技术与波长调制技术的变压器油中C_(2)H_(2)在线监测装置,实现了油中溶解C_(2)H_(2)分离、气体检测、结果分析等功能,测量周期约为25 min,测试过程无损样本。该装置检测精准快速,无需人工操作,可为变压器提供实时的安全参考意见。 展开更多
关键词 变压器油 C_(2)H_(2) 可调谐二极管激光吸收光谱 波长调制 在线监测
下载PDF
Laser absorption spectroscopy for high temperature H_2O time-history measurement at 2.55 μm during oxidation of hydrogen
12
作者 苟于单 张德翔 +3 位作者 王易君 张昌华 李萍 李象远 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期376-381,共6页
Concentration time-histories of H20 were measured behind reflected shock waves during hydrogen combustion. Experiments were conducted at temperatures of 1117-1282 K, the equivalence ratios of 0.5 and 0.25, and a press... Concentration time-histories of H20 were measured behind reflected shock waves during hydrogen combustion. Experiments were conducted at temperatures of 1117-1282 K, the equivalence ratios of 0.5 and 0.25, and a pressure at 2 atm using a mixture of H2/O2 highly diluted with argon. H2O was monitored using tunable mid-infrared diode laser absorption at 2.55 μm (3920.09 cm-1). These time-histories provide kinetic targets to test and refine reaction mechanisms for hydrogen. Comparisons were made with the predictions of four detailed kinetic mechanisms published in the last four years. Such comparisons of H2O concentration profiles indicate that the AramcoMech 2.0 mechanism yields the best agreement with the experimental data, while CRECK, San Diego, and HP-Mech mechanisms show significantly poor predictions. Reaction pathway analysis for hydrogen oxidation indicates that the reaction H + OH + M = H20 + M is the key reaction for controlling the H2O formation by hydrogen oxidation. It is inferred that the discrepancy of the conversion percentage from H to H20 among these four mechanisms induces the difference of performance on H2O time-history predictions. This work demonstrates the potential of time-history measurement for validation of large reaction mechanisms. 展开更多
关键词 tunable diode laser absorption spectroscopy H20 time-history profile combustion process reac- tion mechanism
下载PDF
Dynamic thermal modeling and parameter identification for a monolithic laser diode module
13
作者 李金义 杜振辉 +1 位作者 马艺闻 徐可欣 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第3期317-322,共6页
We improved the thermal equivalent-circuit model of the laser diode module(LDM) to evaluate its thermal dynamic properties and calculate the junction temperature of the laser diode with a high accuracy.The thermal p... We improved the thermal equivalent-circuit model of the laser diode module(LDM) to evaluate its thermal dynamic properties and calculate the junction temperature of the laser diode with a high accuracy.The thermal parameters and the transient junction temperature of the LDM are modeled and obtained according to the temperature of the thermistor integrated in the module.Our improved thermal model is verified indirectly by monitoring the emission wavelength of the laser diode against gas absorption lines,and several thermal parameters are obtained with the temperature uncertainty of 0.01 K in the thermal dynamic process. 展开更多
关键词 laser diode module dynamic thermal modeling thermal time constant tunable diode laser absorption spectroscopy(tdlas)
下载PDF
Sensitive absorption measurements of hydrogen sulfide at 1.578 μm using wavelength modulation spectroscopy 被引量:5
14
作者 夏滑 董凤忠 +6 位作者 吴边 张志荣 庞涛 孙鹏帅 崔小娟 韩荦 王煜 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第3期180-184,共5页
Sensitive detection of hydrogen sulfide(H2S) has been performed by means of wavelength modulation spectroscopy(WMS) near 1.578 μm. With the scan amplitude and the stability of the background baseline taken into a... Sensitive detection of hydrogen sulfide(H2S) has been performed by means of wavelength modulation spectroscopy(WMS) near 1.578 μm. With the scan amplitude and the stability of the background baseline taken into account, the response time is 4 s for a 0.8 L multi-pass cell with a 56.7 m effective optical path length. Moreover, the linearity has been tested in the 0–50 ppmv range. The detection limit achievable by the Allan variance is 224 ppb within 24 s under room temperature and ambient pressure conditions. This tunable diode laser absorption spectroscopy(TDLAS) system for H2 S detection has the feasibility of real-time online monitoring in many applications. 展开更多
关键词 tunable diode laser spectroscopy wavelength modulation hydrogen sulfide detection low absorbance condition
下载PDF
基于TDLAS技术的一氧化碳检测系统设计
15
作者 曹旺 万元 李橙橙 《中国测试》 CAS 北大核心 2023年第S01期215-219,共5页
为满足工业生产过程中的一氧化碳检测需要,研制基于可调谐半导体激光吸收光谱(TDLAS)技术的一氧化碳检测系统。通过分析近红外波段的一氧化碳吸收谱线,选取1567.3nm作为激光器的扫描中心波长,设计系统的气路控制、光学检测与声光报警模... 为满足工业生产过程中的一氧化碳检测需要,研制基于可调谐半导体激光吸收光谱(TDLAS)技术的一氧化碳检测系统。通过分析近红外波段的一氧化碳吸收谱线,选取1567.3nm作为激光器的扫描中心波长,设计系统的气路控制、光学检测与声光报警模块,开发基于FPGA数字锁相放大器的二次谐波解调算法,并采用最小二乘法建立浓度特征值关系曲线,实现一氧化碳的高精度检测。实验表明:该系统检测速度快,抗干扰能力强,能在恶劣的环境中正常工作,检测下限可至10μL/L,与实际浓度的误差在2%左右,具有较高的实用价值。 展开更多
关键词 一氧化碳 调谐半导体激光吸收光谱技术 数字锁相放大器 二次谐波
下载PDF
基于TDLAS的增强型气体检测新技术
16
作者 唐伟 马云鹂 +2 位作者 袁艺朗 张毅 古冉 《石油化工自动化》 CAS 2023年第4期81-84,共4页
可调谐半导体激光吸收光谱技术(TDLAS)是一种在二极管激光器波长调制与长光程吸收池技术相结合的基础上发展起来的新型气体检测方法。介绍了TDLAS技术的工作原理,并列举了其固有的技术缺陷,以及因此导致的在石化行业中的应用限制。通过... 可调谐半导体激光吸收光谱技术(TDLAS)是一种在二极管激光器波长调制与长光程吸收池技术相结合的基础上发展起来的新型气体检测方法。介绍了TDLAS技术的工作原理,并列举了其固有的技术缺陷,以及因此导致的在石化行业中的应用限制。通过对比分析增强型激光二极管吸收频谱技术(ELDS)和TDLAS的应用表明,ELDS技术克服了TDLAS的技术缺陷和应用限制,能够实现对于可燃性碳氢类化合物和蒸气,以及多种有毒有害气体进行快速、高精度、高选择性地在线检测,真正实现零误报、零漏报、零维护。 展开更多
关键词 可调谐半导体激光吸收光谱 增强型激光二极管吸收频谱 激光 自校准 气体检测
下载PDF
数字滤波方法在TDLAS逃逸氨检测中的选用 被引量:18
17
作者 邹得宝 陈文亮 +6 位作者 杜振辉 贾浩 齐汝宾 李红莲 甄杨 侯艳霞 徐可欣 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2012年第9期2322-2326,共5页
介绍了可调谐半导体激光吸收光谱技术(TDLAS)原理和实验系统,并对系统噪声进行了分析;以体积比浓度为90×10-6和30×10-6的NH3为例,利用TDLAS系统采集了该浓度气体的二次谐波原始光谱。为改善光谱信号,分别用五种数字滤波方法... 介绍了可调谐半导体激光吸收光谱技术(TDLAS)原理和实验系统,并对系统噪声进行了分析;以体积比浓度为90×10-6和30×10-6的NH3为例,利用TDLAS系统采集了该浓度气体的二次谐波原始光谱。为改善光谱信号,分别用五种数字滤波方法对原始光谱进行了滤波处理比较,做了NH3的浓度梯度实验并对浓度为20×10-6 NH3进行了长时间监测实验。实验结果表明,算术平均-小波变换滤波相比其他方法更有效地对原始光谱信号进行了改善,提高了系统信噪比和信号平滑度,使系统浓度检测限由原来的10×10-6降低到1.25×10-6,信噪比提高了约14倍,为逃逸氨极低浓度检测提供了一种较为有效的数据预处理方法。 展开更多
关键词 可调谐激光吸收光谱(tdlas) 逃逸氨检测 噪声分析 数字滤波 小波变换
下载PDF
高温高压下基于TDLAS的二氧化碳浓度测量方法研究 被引量:13
18
作者 蔡廷栋 高光珍 +2 位作者 王敏锐 王贵师 高晓明 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2014年第7期1769-1773,共5页
通过具有高灵敏度、非侵入式等特性的可调谐二极管激光吸收光谱技术对发动机气缸工作过程等高温高压燃烧环境进行实时在线检测,是了解其内部燃烧过程进而研发高效发动机的重要手段之一。作为一种重要的温室气体和化石燃料燃烧的主要产物... 通过具有高灵敏度、非侵入式等特性的可调谐二极管激光吸收光谱技术对发动机气缸工作过程等高温高压燃烧环境进行实时在线检测,是了解其内部燃烧过程进而研发高效发动机的重要手段之一。作为一种重要的温室气体和化石燃料燃烧的主要产物,二氧化碳对于了解燃烧过程具有重要的意义。为了寻找一种能够对高温高压燃烧过程中的二氧化碳浓度进行快速检测的方法,利用工作在室温条件下的近红外可调谐二极管激光器作为光源,以二氧化碳位于5 006.140cm-1处的跃迁作为传感谱线,结合固定波长的吸收光谱调制技术,通过该CO2谱线的一次谐波归一化的二次谐波信号峰值实现对高温高压环境中CO2浓度测量,建立了一种可用于高温高压环境下的组份浓度的测量方法,通过实验验证得出该方法在5atm压力、500K温度下和10atm压力、1 000K温度下对于CO2浓度测量的平均标准偏差为3.99%;另外还对实验中所得CO2直接吸收及二次谐波信号进行了分析,得到了其吸收光谱在高温高压环境下的特性。 展开更多
关键词 可调谐二极管激光吸收光谱 波长调制光谱 高温高压 二氧化碳浓度
下载PDF
基于TDLAS技术同时检测卷烟主流烟气中的CO和CO_2 被引量:15
19
作者 邢昆明 杨柯 +5 位作者 张龙 吴晓松 李志刚 王安 刘勇 计敏 《量子电子学报》 CAS CSCD 北大核心 2017年第1期81-87,共7页
基于可调谐二极管激光吸收光谱(TDLAS)技术、波长调制技术和二次谐波检测方法,利用CO和CO_2在1579 nm处的泛频吸收特征,结合改造后的单孔道吸烟机,建立了卷烟主流烟气逐口检测系统。实验结果表明:气体浓度与其二次谐波强度的线性度较好... 基于可调谐二极管激光吸收光谱(TDLAS)技术、波长调制技术和二次谐波检测方法,利用CO和CO_2在1579 nm处的泛频吸收特征,结合改造后的单孔道吸烟机,建立了卷烟主流烟气逐口检测系统。实验结果表明:气体浓度与其二次谐波强度的线性度较好,系统响应速度较快,精度能达到检测要求,逐口检测稳定性、重复性和灵敏度均较好。同类型卷烟主流烟气中CO、CO_2的逐口释放量除第1口之外,均呈递增趋势,CO_2的逐口释放量和递增速率均比CO的大,且不同类型的卷烟遵循相同的规律。所建系统具有检测速度快、时间分辨率高、结构简单等优势,在卷烟烟气有害物质的快速检测领域具有较好的应用前景。 展开更多
关键词 光谱学 同时检测 可调谐二极管激光吸收光谱 卷烟烟气 CO CO2
下载PDF
基于TDLAS技术的水汽低温吸收光谱参数测量 被引量:19
20
作者 聂伟 阚瑞峰 +5 位作者 许振宇 姚路 夏晖晖 彭于权 张步强 何亚柏 《物理学报》 SCIE EI CAS CSCD 北大核心 2017年第20期91-96,共6页
精确的气体光谱参数对气体浓度、温度等的光谱精确反演测量具有十分重要的意义,针对当前主流光谱数据库(例如HITRAN)中数据与实际数值存在相当误差的问题,自主研制了一套基于静态冷却技术的低温光谱实验平台,用于精确测量低温下的气体... 精确的气体光谱参数对气体浓度、温度等的光谱精确反演测量具有十分重要的意义,针对当前主流光谱数据库(例如HITRAN)中数据与实际数值存在相当误差的问题,自主研制了一套基于静态冷却技术的低温光谱实验平台,用于精确测量低温下的气体吸收光谱参数.运用该低温光谱实验平台,采用可调谐二极管激光吸收光谱(TDLAS)技术测量了温度为230—340 K、压强为10—1000 Pa时7240—7246 cm^(-1)波段的纯水汽振转跃迁光谱.采用Voigt线型多峰拟合方法,获得了5条水汽振转跃迁谱在不同温度、不同压强下的积分吸光度值及洛伦兹展宽值,运用线性拟合的方法得到这5条吸收线的自展宽半峰全宽系数及参考温度下的线强值.运用不确定度传递公式,计算得到实验结果的不确定度,与HITRAN2012数据库中的线参数进行对比,所测的5条吸收线中实验结果与数据库值最大相差10.96%,且实验结果的不确定度为1.11%—2.98%(置信概率p=95%,包含因子k=2),小于HITRAN2012数据库值的不确定度. 展开更多
关键词 可调谐二极管激光器 吸收光谱 水汽 线强 自展宽系数
下载PDF