Flexible damping technology considering aseismic materials and aseismic structures seems be a good solution for engineering structures.In this study,a constrained damping structure for underground tunnel lining,using ...Flexible damping technology considering aseismic materials and aseismic structures seems be a good solution for engineering structures.In this study,a constrained damping structure for underground tunnel lining,using a rubber-sand-concrete(RSC)as the aseismic material,is proposed.The aseismic performances of constrained damping structure were investigated by a series of hammer impact tests.The damping layer thickness and shape effects on the aseismic performance such as effective duration and acceleration amplitude of time-domain analysis,composite loss factor and damping ratio of the transfer function analysis,and total vibration level of octave spectrum analysis were discussed.The hammer impact tests revealed that the relationship between the aseismic performance and damping layer thickness was not linear,and that the hollow damping layer had a better aseismic performance than the flat damping layer one.The aseismic performances of constrained damping structure under different seismicity magnitudes and geological conditions were investigated.The effects of the peak ground acceleration(PGA)and tunnel overburden depth on the aseismic performances such as the maximum principal stress and equivalent plastic strain(PEEQ)were discussed.The numerical results show the constrained damping structure proposed in this paper has a good aseismic performance,with PGA in the range(0.2-1.2)g and tunnel overburden depth in the range of 0-300 m.展开更多
为研究预应力混凝土用钢棒(steel bar for prestressed concrete, PC钢棒)-钢筋混合配筋混凝土柱的抗震性能,设计制作了5根相同尺寸、相同纵筋配筋率、不同PC钢棒替代率的PC钢棒-钢筋混合配筋混凝土柱试件,通过拟静力试验研究了PC钢棒...为研究预应力混凝土用钢棒(steel bar for prestressed concrete, PC钢棒)-钢筋混合配筋混凝土柱的抗震性能,设计制作了5根相同尺寸、相同纵筋配筋率、不同PC钢棒替代率的PC钢棒-钢筋混合配筋混凝土柱试件,通过拟静力试验研究了PC钢棒替代率对试件抗震性能的影响规律。结果表明:随着PC钢棒替代率的提高,试件的裂缝分布高度降低,裂缝数量变少,滞回曲线的饱满程度逐渐降低,耗能能力降低,残余位移角减小,自复位能力增强;当PC钢棒的替代率不大于50%时,各试件的峰值荷载接近;当PC钢棒的替代率大于50%时,试件的峰值荷载随PC钢棒替代率的增大而提高;当加载位移角相同且不大于1.0%时,配置PC钢棒的混凝土柱的残余位移角较为接近,且明显小于未配置PC钢棒的钢筋混凝土柱的残余位移角;当加载位移角相同且大于1%时,柱的残余位移角随着PC钢棒替代率的增高而降低。展开更多
基金supported by the National Natural Science Foundation of China(No.52079133)CRSRI Open Research Program(Program SN:CKWV2019746/KY)+1 种基金the project of Key Laboratory of Water Grid Project and Regulation of Ministry of Water Resources(QTKS0034W23291)the Youth Innovation Promotion Association CAS.
文摘Flexible damping technology considering aseismic materials and aseismic structures seems be a good solution for engineering structures.In this study,a constrained damping structure for underground tunnel lining,using a rubber-sand-concrete(RSC)as the aseismic material,is proposed.The aseismic performances of constrained damping structure were investigated by a series of hammer impact tests.The damping layer thickness and shape effects on the aseismic performance such as effective duration and acceleration amplitude of time-domain analysis,composite loss factor and damping ratio of the transfer function analysis,and total vibration level of octave spectrum analysis were discussed.The hammer impact tests revealed that the relationship between the aseismic performance and damping layer thickness was not linear,and that the hollow damping layer had a better aseismic performance than the flat damping layer one.The aseismic performances of constrained damping structure under different seismicity magnitudes and geological conditions were investigated.The effects of the peak ground acceleration(PGA)and tunnel overburden depth on the aseismic performances such as the maximum principal stress and equivalent plastic strain(PEEQ)were discussed.The numerical results show the constrained damping structure proposed in this paper has a good aseismic performance,with PGA in the range(0.2-1.2)g and tunnel overburden depth in the range of 0-300 m.
文摘为研究预应力混凝土用钢棒(steel bar for prestressed concrete, PC钢棒)-钢筋混合配筋混凝土柱的抗震性能,设计制作了5根相同尺寸、相同纵筋配筋率、不同PC钢棒替代率的PC钢棒-钢筋混合配筋混凝土柱试件,通过拟静力试验研究了PC钢棒替代率对试件抗震性能的影响规律。结果表明:随着PC钢棒替代率的提高,试件的裂缝分布高度降低,裂缝数量变少,滞回曲线的饱满程度逐渐降低,耗能能力降低,残余位移角减小,自复位能力增强;当PC钢棒的替代率不大于50%时,各试件的峰值荷载接近;当PC钢棒的替代率大于50%时,试件的峰值荷载随PC钢棒替代率的增大而提高;当加载位移角相同且不大于1.0%时,配置PC钢棒的混凝土柱的残余位移角较为接近,且明显小于未配置PC钢棒的钢筋混凝土柱的残余位移角;当加载位移角相同且大于1%时,柱的残余位移角随着PC钢棒替代率的增高而降低。