The measurement of the overall mass flow rates in a two phase, gas/liquid pipeline is considered on the basis of dual pressure differential measurements for a combined contraction/frictional pipe type of flow meter an...The measurement of the overall mass flow rates in a two phase, gas/liquid pipeline is considered on the basis of dual pressure differential measurements for a combined contraction/frictional pipe type of flow meter and a numerical model to predict overall mass flow rates from pressure differentials measured from this type of flow meter is presented. The experiments generally conform with the predictions of the flow rates prediction model. Whilst the practicability of such metering of two phase flows is clearly demonstrated, application of the method would require careful calibration to allow for the influence of nozzle coefficients, pipe Reynolds number and void fraction upon the one dimensional compressible flow equations through wall friction factor and interphase slip effects.展开更多
We propose a novel flow measurement method for gas–liquid two-phase slug flow by using the blind source separation technique. The flow measurement model is established based on the fluctuation characteristics of diff...We propose a novel flow measurement method for gas–liquid two-phase slug flow by using the blind source separation technique. The flow measurement model is established based on the fluctuation characteristics of differential pressure(DP) signals measured from a Venturi meter. It is demonstrated that DP signals of two-phase flow are a linear mixture of DP signals of single phase fluids. The measurement model is a combination of throttle relationship and blind source separation model. In addition, we estimate the mixture matrix using the independent component analysis(ICA) technique. The mixture matrix could be described using the variances of two DP signals acquired from two Venturi meters. The validity of the proposed model was tested in the gas–liquid twophase flow loop facility. Experimental results showed that for most slug flow the relative error is within 10%.We also find that the mixture matrix is beneficial to investigate the flow mechanism of gas–liquid two-phase flow.展开更多
Single-phase and gas-liquid two-phase pressure drops caused by a sudden con-traction in microtubes were experimentally investigated at room temperature and atmospheric pressure,using nitrogen and water. The experiment...Single-phase and gas-liquid two-phase pressure drops caused by a sudden con-traction in microtubes were experimentally investigated at room temperature and atmospheric pressure,using nitrogen and water. The experimental results on pressure drop with a novel measurement method,the tiny gaps on the tubes,were used to characterize the sudden contraction pressure drop for tube diameters from 850 to 330 μm. The ranges of the gas and liquid superficial velocity were 2.55―322.08 and 0.98―9.78 m/s in the smaller tube respectively. In single-phase flow experiments,the contraction loss coefficients were larger than the experimental results from conventional tubes in the laminar flow. While in the turbulent flow,the contraction loss coefficients were slightly smaller than those from conventional tubes and predicted well by Kc=0.5×(1-σ2)0.75. In two-phase flow experiments,the slip flow model with a velocity slip ratio S=(ρL/ρG)1/3 showed a good prediction that reveals the occurrence of velocity slip. An empirical correlation for two-phase flow pressure drops caused by the sudden contraction was developed based on the proposed contraction loss coefficients correlation for single-phase flow and Mar-tinelli factor.展开更多
The histories of differential pressure fluctuations and their Fast Fourier Transform spectrum have close relation with the flow regimes.Unfortunately,each type of flow regime is very difficult or impossible to be dist...The histories of differential pressure fluctuations and their Fast Fourier Transform spectrum have close relation with the flow regimes.Unfortunately,each type of flow regime is very difficult or impossible to be distinguished from the other on the basis of the fluctuations or the spectrum.The present paper provides a feasible solution, which the gas-liquid two-phase flow regimes can be recognized automatically and objectively on the basis of the combination of the Counter Propagation Network (CPN) and the FFT spectrum of the differential pressure fluctuations. The CPN takes advantages of simpler algorithm and fast training processes.Furthermore,it does not require a great deal of samples.The recognition possibility is determined by the clustering results of the Kohonen layer in the CPN.With the presented test cases,the possibility can be higher than 90 percent for different liquid phase velocity.展开更多
文摘The measurement of the overall mass flow rates in a two phase, gas/liquid pipeline is considered on the basis of dual pressure differential measurements for a combined contraction/frictional pipe type of flow meter and a numerical model to predict overall mass flow rates from pressure differentials measured from this type of flow meter is presented. The experiments generally conform with the predictions of the flow rates prediction model. Whilst the practicability of such metering of two phase flows is clearly demonstrated, application of the method would require careful calibration to allow for the influence of nozzle coefficients, pipe Reynolds number and void fraction upon the one dimensional compressible flow equations through wall friction factor and interphase slip effects.
基金Supported by the National Natural Science Foundation of China(51304231)the Natural Science Foundation of Shandong Province(ZR2010EQ015)
文摘We propose a novel flow measurement method for gas–liquid two-phase slug flow by using the blind source separation technique. The flow measurement model is established based on the fluctuation characteristics of differential pressure(DP) signals measured from a Venturi meter. It is demonstrated that DP signals of two-phase flow are a linear mixture of DP signals of single phase fluids. The measurement model is a combination of throttle relationship and blind source separation model. In addition, we estimate the mixture matrix using the independent component analysis(ICA) technique. The mixture matrix could be described using the variances of two DP signals acquired from two Venturi meters. The validity of the proposed model was tested in the gas–liquid twophase flow loop facility. Experimental results showed that for most slug flow the relative error is within 10%.We also find that the mixture matrix is beneficial to investigate the flow mechanism of gas–liquid two-phase flow.
基金the National Key Basic Research Program (Grant No. G2000026300)Beijing Open Fund
文摘Single-phase and gas-liquid two-phase pressure drops caused by a sudden con-traction in microtubes were experimentally investigated at room temperature and atmospheric pressure,using nitrogen and water. The experimental results on pressure drop with a novel measurement method,the tiny gaps on the tubes,were used to characterize the sudden contraction pressure drop for tube diameters from 850 to 330 μm. The ranges of the gas and liquid superficial velocity were 2.55―322.08 and 0.98―9.78 m/s in the smaller tube respectively. In single-phase flow experiments,the contraction loss coefficients were larger than the experimental results from conventional tubes in the laminar flow. While in the turbulent flow,the contraction loss coefficients were slightly smaller than those from conventional tubes and predicted well by Kc=0.5×(1-σ2)0.75. In two-phase flow experiments,the slip flow model with a velocity slip ratio S=(ρL/ρG)1/3 showed a good prediction that reveals the occurrence of velocity slip. An empirical correlation for two-phase flow pressure drops caused by the sudden contraction was developed based on the proposed contraction loss coefficients correlation for single-phase flow and Mar-tinelli factor.
文摘The histories of differential pressure fluctuations and their Fast Fourier Transform spectrum have close relation with the flow regimes.Unfortunately,each type of flow regime is very difficult or impossible to be distinguished from the other on the basis of the fluctuations or the spectrum.The present paper provides a feasible solution, which the gas-liquid two-phase flow regimes can be recognized automatically and objectively on the basis of the combination of the Counter Propagation Network (CPN) and the FFT spectrum of the differential pressure fluctuations. The CPN takes advantages of simpler algorithm and fast training processes.Furthermore,it does not require a great deal of samples.The recognition possibility is determined by the clustering results of the Kohonen layer in the CPN.With the presented test cases,the possibility can be higher than 90 percent for different liquid phase velocity.