Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to...Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data.展开更多
BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefor...BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases.展开更多
BACKGROUND Artifacts are common when using two-dimensional shear wave elastography(2-D SWE)to measure liver stiffness(LS),but they are poorly recognized.AIM To investigate the presence and influence of artifacts in 2-...BACKGROUND Artifacts are common when using two-dimensional shear wave elastography(2-D SWE)to measure liver stiffness(LS),but they are poorly recognized.AIM To investigate the presence and influence of artifacts in 2-D SWE of liver.METHODS We included 158 patients with chronic liver disease,who underwent 2-D SWE examination by a novice and an expert.A cross line at the center of the elastogram was drawn and was divided it into four locations:top-left,top-right,bottom-left,and bottom-right.The occurrence frequency of artifacts in different locations was compared.The influence of artifacts on the LS measurements was evaluated by comparing the elastogram with the most artifacts(EMA)and the elastogram with the least artifacts(ELA).RESULTS The percentage of elastograms with artifacts in the novice(51.7%)was significantly higher than that of the expert(19.6%)(P<0.001).It was found that both operators had the highest frequency of artifacts at bottom-left,followed by top-left and bottom-right,and top-right had the lowest frequency.The LS values(LSVs)and standard deviation values of EMAs were significantly higher than those of ELAs for both operators.An intraclass correlation coefficient value of 0.96 was found in the LSVs of EMAs of the two operators,and it increased to 0.98 when the LSVs of the ELAs were used.Both operators had lower stability index values for EMAs than ELAs,but the difference was only statistically significant for the novice.CONCLUSION Artifacts are common when using 2-D SWE to measure LS,especially for the novice.Artifacts may lead to the overestimation of LS and reduce the repeatability and reliability of LS measurements.展开更多
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili...BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.展开更多
Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical ...Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical manifestations associated with early arterial complications following liver transplantation are often non-specific.Without timely intervention,these complications can result in graft fai-lure or patient mortality.Therefore,early diagnosis and the formulation of an op-timal treatment plan are imperative.Ultrasound examination remains the pre-dominant imaging modality for detecting complications post liver transplan-tation.This article comprehensively reviews common causes and clinical present-ations of early hepatic artery complications in the post-transplantation period and delineates abnormal sonographic findings for accurate diagnosis of these con-ditions.Overall,ultrasound offers the advantages of convenience,safety,effect-iveness,and non-invasiveness.It enables real-time,dynamic,and precise evalua-tion,making it the preferred diagnostic method for post-liver transplantation assessments.INTRODUCTION Liver transplantation stands as the primary therapeutic approach for end-stage liver disease.Continuous advancements in surgical techniques and the application of novel immunosuppressive agents contribute to ongoing improvements in the success rate and overall survival in patients undergoing liver transplantation procedures.Despite these advan-cements,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.During the early stages following liver transplantation(within the first 30 d),proper hepatic artery function is crucial for hepatic arterial blood flow.During later stages,collateral circulation,including arteries such as the phrenic artery,right gastric artery,and gastroduodenal artery,becomes important for maintaining hepatic blood supply.It is now understood that the establishment of effective collateral circulation is pivotal for determining the prognosis of hepatic artery complic-ations.The clinical manifestations of these complications are closely linked to factors such as timing,severity,and the specific type of onset.Insufficient hepatic arterial blood flow can lead to abnormal liver function,hepatic infarction,and the formation of hepatic abscesses.Additionally,since the hepatic artery is the sole blood supply to the biliary tract,hepatic artery-related ischemia may result in biliary stricture,obstruction,and the formation of bile ducts.Ultrasound examination remains the primary imaging modality for diagnosing complications post liver transplantation.This article comprehensively reviews common causes and clinical presentations of early hepatic artery complications in the post-transplantation period and outlines abnormal sonographic findings for accurately diagnosing these conditions.NORMAL HEPATIC ARTERY During the intraoperative phase,an ultrasound examination is typically conducted to evaluate the hepatic artery anas-tomosis.The normal internal diameter of the hepatic artery typically ranges from 2 to 5 mm.Two strong echo points are typically identified near the anastomosis.To assess blood flow dynamics,peak systolic velocity,end-diastolic velocity,and resistance index are measured at the donor and recipient sides of the anastomosis following angle correction.Anastomotic stenosis presence and severity can be evaluated by comparing the velocity at the anastomotic site with that at the recipient side.Postoperatively,direct visualization of the anastomosis site through gray ultrasound scans is often challenging.The surgical approach has a significant impact on the proper hepatic artery’s position,resulting in a lower overall success rate of continuous visualization.Color Doppler ultrasound is primarily employed to trace the artery’s path,and spectral measurements are taken at the brightest position of the Color Doppler blood flow signal,primarily used to identify the presence of high-speed turbulence.Hepatic artery spectrum examination plays a crucial role,as a favorable arterial spectral waveform and appropriate hepatic artery flow velocity typically indicate a successful anastomosis,even in cases where the hepatic artery anastomosis cannot be directly visualized by ultrasound.The hepatic artery runs alongside the portal vein,often selected as a reference due to its larger inner diameter.A normal hepatic artery spectrum displays a regular pulsation pattern with a rapid rise in systole and a slow decline in diastole.Parameters for assessing hepatic artery resistance include a resistance index between 0.5 to 0.8 and an artery systolic acceleration of less than 80 ms.Instantaneous increases in the resistance index(RI>0.8)often occur within 2 d after surgery,followed by a subsequent return to normal hepatic arterial parameters.It has been established that the maximum blood flow velocity during systole in the hepatic artery should not exceed 200 cm/s[1].展开更多
Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween Septem...Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia.展开更多
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso...BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS.展开更多
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ...This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients.展开更多
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana...BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care.展开更多
Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,su...Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,such as gastroenterologists.Endoscopic ultrasound,as a novel technique,plays a crucial role in diagnosis and treatment of digestive diseases.However,its use is sometimes recommended for conditions where no clear advantage over percutaneous ultrasound exists,leaving the impression that clinicians sometimes resort to an endoscopic approach due to the unavailability of percutaneous options.展开更多
Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many wome...Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives.展开更多
BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histologic...BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histological exam.The patterns of enhancement and wash-out of liver nodules can be used to stratify the risk of malignancy only in cirrhotic patients and HCC frequently shows atypical features.Dynamic contrast-enhanced ultrasound(DCEUS)with standardized software could help to overcome these obstacles,providing functional and quantitative parameters and potentially improving accuracy in the evaluation of tumor perfusion.AIM To explore clinical evidence regarding the application of DCEUS in the differential diagnosis of liver nodules.METHODS A comprehensive literature search of clinical studies was performed to identify the parameters of DCEUS that could relate to histological diagnosis.In accordance with the study protocol,a qualitative and quantitative analysis of the evidence was planned.RESULTS Rise time was significantly higher in HCC patients with a standardized mean difference(SMD)of 0.83(95%CI:0.48-1.18).Similarly,other statistically significant parameters were mean transit time local with a SMD of 0.73(95%CI:0.20-1.27),peak enhancement with a SMD of 0.37(95%CI:0.03-0.70),area wash-in area under the curve with a SMD of 0.47(95%CI:0.13-0.81),wash-out area under the curve with a SMD of 0.55(95%CI:0.21-0.89)and wash-in and wash-out area under the curve with SMD of 0.51(95%CI:0.17-0.85).SMD resulted not significant in fall time and wash-in rate,but the latter presented a trend towards greater values in HCC compared to intrahepatic cholangiocarcinoma.CONCLUSION DCEUS could improve non-invasive diagnosis of HCC,leading to less liver biopsy and early treatment.This quantitative analysis needs to be applied on larger cohorts to confirm these preliminary results.展开更多
BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for t...BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions.展开更多
This editorial discusses the manuscript by Di Maria et al,published in the recent issue of the World Journal of Cardiology.We here focus on the still elusive pathophysiological mechanisms underlying cardio-renal syndr...This editorial discusses the manuscript by Di Maria et al,published in the recent issue of the World Journal of Cardiology.We here focus on the still elusive pathophysiological mechanisms underlying cardio-renal syndrome(CRS),despite its high prevalence and the substantial worsening of both kidney function and heart failure.While the measure of right atrial pressure through right cardiac catheterization remains the most accurate albeit invasive and costly procedure,integrating bedside ultrasound into diagnostic protocols may substantially enhance the staging of venous congestion and guide therapeutic decisions.In particular,with the assessment of Doppler patterns across multiple venous districts,the Venous Excess Ultrasound(VExUS)score improves the management of fluid overload and provides insight into the underlying factors contributing to cardio-renal interactions.Integrating specific echocardiographic parameters,particularly those concerning the right heart,may thus improve the VExUS score sensitivity,offering perspective into the nuanced comprehension of cardio-renal dynamics.A multidisciplinary approach that consistently incorporates the use of ultrasound is emerging as a promising advance in the understanding and management of CRS.展开更多
Objective: To explore the value of percutaneous ultrasonography combined with transvenous ultrasonography for accurate localization of sentinel lymph nodes and diagnosis of metastatic lymph nodes in patients with brea...Objective: To explore the value of percutaneous ultrasonography combined with transvenous ultrasonography for accurate localization of sentinel lymph nodes and diagnosis of metastatic lymph nodes in patients with breast cancer. Methods: 18 cases of patients with breast cancer attending the Hainan General Hospital from May 2022 to June 2024 who were proposed to undergo axillary lymph node dissection were selected, and the ultrasonographic agent was injected subcutaneously through the areola on the 1st day before the operation, and the marker localization of the manifestation of the Sentinel lymph nodes and draw the lymphatic vessel alignment for drainage on the body surface, and record the manifestation of SLN by conventional ultrasound and dual ultrasonography. At the time of surgery, intraoperative melphalan localization was used to identify the SLN, the difference between the number of ultrasound and melphalan localization was observed, and resection was performed for pathological examination to determine whether they were metastatic or not. Results: There were 8 metastatic lymph nodes and 18 non-metastatic lymph nodes among 31 SLN. A total of 62 SLN were localized by intraoperative melphalan, of which 31 were consistent with ultrasound localization and 31 were not identified by ultrasound. The diagnostic sensitivity of SLN metastasis diagnosed by transcutaneous ultrasonography was 62.50%, specificity was 91.30%, positive predictive value was 71.43%, negative predictive value 87.50%, accuracy was 83.87%, and the AUC was 0.769;the diagnostic sensitivityof transvenous ultrasonography diagnosed was 75.00%, specificity was 75.00%, and the accuracy was 83.87%, 75.00%, specificity 91.30%, positive predictive value 75.00%, negative predictive value 91.30%, accuracy 87.10%, AUC 0.832;dual ultrasonography diagnostic sensitivity 87.50%, specificity 91.30%, positive predictive value 77.78%, negative predictive value 95.45%, accuracy 90.32%. The AUC was 0.894. Conclusion: Transcutaneous ultrasonography combined with transvenous ultrasonography can accurately localize sentinel lymph nodes and improve the sensitivity and accuracy of the diagnosis of metastatic SLN.展开更多
The gallbladder(GB)is a susceptible organ,prone to various pathologies that can be identified using different imaging techniques.Transabdominal ultrasound(TUS)is typically the initial diagnostic method due to its nume...The gallbladder(GB)is a susceptible organ,prone to various pathologies that can be identified using different imaging techniques.Transabdominal ultrasound(TUS)is typically the initial diagnostic method due to its numerous well-established advantages.However,in cases of uncertainty or when a definitive diagnosis cannot be established,computed tomography(CT)or magnetic resonance imaging may be employed to provide more detailed information.Nevertheless,CT scans may sometimes offer inadequate spatial resolution,which can limit the differentiation of GB lesions,particularly when smaller yet clinically relevant abnormalities are involved.Conversely,endoscopic ultrasound(EUS)provides higher frequency compared to TUS,superior spatial resolution,and the option for contrast-enhanced harmonic imaging,enabling a more comprehensive examination.Thus,EUS can serve as a supplementary tool when conventional imaging methods are insufficient.This review will describe the standard EUS examination of the GB,focusing on its endosonographic characteristics in various GB path-ologies.展开更多
Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and aff...Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and affects the response to treatment of patients with hepatocellular carcinoma(HCC).For these reasons,identifying an easy-to-perform method to assess sarcopenia in is a key element in the optimization of care in this patient population.Assessment of muscle mass by computed tomography is considered the standard of care for the diagnosis of sarcopenia,but exposure to radiation and high costs limit its application in this setting,especially for repeated assessments.We believe that ultrasound,a cheap and harmless technique also used for HCC screening in cirrhotic patients,could have an expanding role in the diagnosis and follow-up of sarcopenia in these patients.展开更多
In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary dra...In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary drainage are usually guided by fluoroscopy or transcutaneous ultrasound,endoscopic ultrasound(EUS),or both.Endoscopic retrograde cholangiopancreatography(ERCP)has been primarily recommended for the management of biliary obstruction,while EUS-guided biliary drainage and percutaneous transhepatic biliary drainage(PTBD)are alternative choices for cases where ERCP has failed or is impossible.PTBD is limited by shortcomings of a higher rate of adverse events,more reinterventions,and severe complications.EUS-guided biliary drainage has a lower rate of adverse events than PTBD.EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent(ECE-LAMS)enables EUS-guided biliaryenteric anastomosis to be performed in a single step and does not require prior bile duct puncture or a guidewire.The present meta-analysis showed that ECELAMS has a high efficacy and safety in relieving biliary obstruction in general,although the results of LAMS depending on the site of biliary obstruction.This study has highlighted the latest advances with a larger sample-based comprehensive analysis.展开更多
Objectives: To demonstrate the contribution and relevance of ETFs through the study of 1000 examination reports carried out in the medical imaging departments of the OUAGADOUGOU CHU. Material and method: Analytical de...Objectives: To demonstrate the contribution and relevance of ETFs through the study of 1000 examination reports carried out in the medical imaging departments of the OUAGADOUGOU CHU. Material and method: Analytical descriptive study with retrospective collection, extended from 1st January 2020 to 1st January 2022. Results: Of the 1000 transfontanellar ultrasound reports, the mean age of patients was 7.61 +/ 7.5 days, with extremes of zero and 28 days. Sex was specified in 989 cases. Males accounted for 54.49% and females for 45.51%. 555 transfontanellar ultrasound were performed in 2020. 441 in 2021 and 4 in 2022. 61.9% of transfontanellar ultrasound were performed at the Bogodogo University Hospital, 205 at Charles de Gaulle and 176 at Tengandogo. Indications for transfontanellar ultrasound were dominated by neonatal distress (65.8%), followed by convulsions (10.2%) and prematurity (9.1%). Transfontanellar ultrasound was normal in 570 cases (57%) and abnormal in 430 cases (43%). Abnormalities were dominated by haemorrhage and ischaemic lesions in 66.28% (285) and 21.63% (93) of cases respectively. In the group of normal transfontanellar ultrasound, neonatal distress represented 59.65% of indications and prematurity 10.7% of indications. As for abnormal transfontanellar ultrasound, neonatal suffering accounted for 73.95% of indications and convulsions for 12.56%. The average age ofpatients with an abnormal transfontanellar ultrasound was 8.74 days +/ 7.89 days. The indication for investigations was relevant in 42.2% of cases and irrelevant in 57.8%;of the transfontanellar ultrasound with relevant indications, 0.71 were normal and 99.29 abnormal;of the transfontanellar ultrasound with irrelevant indications, the transfontanellar ultrasound was normal in 98.1% and abnormal in 1.9%. Conclusion: Transfontanellar ultrasound is an important part of ultrasound in current practice. Haemorrhage, anoxic-ischaemic lesions and hydrocephalus are the most frequent pathologies found by this technique in newborns. Whether or not the examinations were normal depended on the appropriateness of the prescription.展开更多
In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation pr...In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment.展开更多
文摘Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data.
文摘BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases.
文摘BACKGROUND Artifacts are common when using two-dimensional shear wave elastography(2-D SWE)to measure liver stiffness(LS),but they are poorly recognized.AIM To investigate the presence and influence of artifacts in 2-D SWE of liver.METHODS We included 158 patients with chronic liver disease,who underwent 2-D SWE examination by a novice and an expert.A cross line at the center of the elastogram was drawn and was divided it into four locations:top-left,top-right,bottom-left,and bottom-right.The occurrence frequency of artifacts in different locations was compared.The influence of artifacts on the LS measurements was evaluated by comparing the elastogram with the most artifacts(EMA)and the elastogram with the least artifacts(ELA).RESULTS The percentage of elastograms with artifacts in the novice(51.7%)was significantly higher than that of the expert(19.6%)(P<0.001).It was found that both operators had the highest frequency of artifacts at bottom-left,followed by top-left and bottom-right,and top-right had the lowest frequency.The LS values(LSVs)and standard deviation values of EMAs were significantly higher than those of ELAs for both operators.An intraclass correlation coefficient value of 0.96 was found in the LSVs of EMAs of the two operators,and it increased to 0.98 when the LSVs of the ELAs were used.Both operators had lower stability index values for EMAs than ELAs,but the difference was only statistically significant for the novice.CONCLUSION Artifacts are common when using 2-D SWE to measure LS,especially for the novice.Artifacts may lead to the overestimation of LS and reduce the repeatability and reliability of LS measurements.
基金The authors have read the PRISMA 2009 Checklist,and the manuscript was prepared and revised according to the PRISMA 2009 Checklist.
文摘BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.
基金Supported by the Shenzhen Science and Technology R&D Fund,No.JCYJ20220530163011026and Shenzhen Third People’s Hospital,No.G2022008 and No.G2021008。
文摘Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical manifestations associated with early arterial complications following liver transplantation are often non-specific.Without timely intervention,these complications can result in graft fai-lure or patient mortality.Therefore,early diagnosis and the formulation of an op-timal treatment plan are imperative.Ultrasound examination remains the pre-dominant imaging modality for detecting complications post liver transplan-tation.This article comprehensively reviews common causes and clinical present-ations of early hepatic artery complications in the post-transplantation period and delineates abnormal sonographic findings for accurate diagnosis of these con-ditions.Overall,ultrasound offers the advantages of convenience,safety,effect-iveness,and non-invasiveness.It enables real-time,dynamic,and precise evalua-tion,making it the preferred diagnostic method for post-liver transplantation assessments.INTRODUCTION Liver transplantation stands as the primary therapeutic approach for end-stage liver disease.Continuous advancements in surgical techniques and the application of novel immunosuppressive agents contribute to ongoing improvements in the success rate and overall survival in patients undergoing liver transplantation procedures.Despite these advan-cements,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.During the early stages following liver transplantation(within the first 30 d),proper hepatic artery function is crucial for hepatic arterial blood flow.During later stages,collateral circulation,including arteries such as the phrenic artery,right gastric artery,and gastroduodenal artery,becomes important for maintaining hepatic blood supply.It is now understood that the establishment of effective collateral circulation is pivotal for determining the prognosis of hepatic artery complic-ations.The clinical manifestations of these complications are closely linked to factors such as timing,severity,and the specific type of onset.Insufficient hepatic arterial blood flow can lead to abnormal liver function,hepatic infarction,and the formation of hepatic abscesses.Additionally,since the hepatic artery is the sole blood supply to the biliary tract,hepatic artery-related ischemia may result in biliary stricture,obstruction,and the formation of bile ducts.Ultrasound examination remains the primary imaging modality for diagnosing complications post liver transplantation.This article comprehensively reviews common causes and clinical presentations of early hepatic artery complications in the post-transplantation period and outlines abnormal sonographic findings for accurately diagnosing these conditions.NORMAL HEPATIC ARTERY During the intraoperative phase,an ultrasound examination is typically conducted to evaluate the hepatic artery anas-tomosis.The normal internal diameter of the hepatic artery typically ranges from 2 to 5 mm.Two strong echo points are typically identified near the anastomosis.To assess blood flow dynamics,peak systolic velocity,end-diastolic velocity,and resistance index are measured at the donor and recipient sides of the anastomosis following angle correction.Anastomotic stenosis presence and severity can be evaluated by comparing the velocity at the anastomotic site with that at the recipient side.Postoperatively,direct visualization of the anastomosis site through gray ultrasound scans is often challenging.The surgical approach has a significant impact on the proper hepatic artery’s position,resulting in a lower overall success rate of continuous visualization.Color Doppler ultrasound is primarily employed to trace the artery’s path,and spectral measurements are taken at the brightest position of the Color Doppler blood flow signal,primarily used to identify the presence of high-speed turbulence.Hepatic artery spectrum examination plays a crucial role,as a favorable arterial spectral waveform and appropriate hepatic artery flow velocity typically indicate a successful anastomosis,even in cases where the hepatic artery anastomosis cannot be directly visualized by ultrasound.The hepatic artery runs alongside the portal vein,often selected as a reference due to its larger inner diameter.A normal hepatic artery spectrum displays a regular pulsation pattern with a rapid rise in systole and a slow decline in diastole.Parameters for assessing hepatic artery resistance include a resistance index between 0.5 to 0.8 and an artery systolic acceleration of less than 80 ms.Instantaneous increases in the resistance index(RI>0.8)often occur within 2 d after surgery,followed by a subsequent return to normal hepatic arterial parameters.It has been established that the maximum blood flow velocity during systole in the hepatic artery should not exceed 200 cm/s[1].
文摘Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia.
基金Supported by the National Natural Science Foundation of China,No.82305380The Postdoctoral Research Program,West China Hospital,Sichuan University,No.2020HXBH018.
文摘BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS.
文摘This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients.
文摘BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care.
文摘Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,such as gastroenterologists.Endoscopic ultrasound,as a novel technique,plays a crucial role in diagnosis and treatment of digestive diseases.However,its use is sometimes recommended for conditions where no clear advantage over percutaneous ultrasound exists,leaving the impression that clinicians sometimes resort to an endoscopic approach due to the unavailability of percutaneous options.
文摘Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives.
文摘BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histological exam.The patterns of enhancement and wash-out of liver nodules can be used to stratify the risk of malignancy only in cirrhotic patients and HCC frequently shows atypical features.Dynamic contrast-enhanced ultrasound(DCEUS)with standardized software could help to overcome these obstacles,providing functional and quantitative parameters and potentially improving accuracy in the evaluation of tumor perfusion.AIM To explore clinical evidence regarding the application of DCEUS in the differential diagnosis of liver nodules.METHODS A comprehensive literature search of clinical studies was performed to identify the parameters of DCEUS that could relate to histological diagnosis.In accordance with the study protocol,a qualitative and quantitative analysis of the evidence was planned.RESULTS Rise time was significantly higher in HCC patients with a standardized mean difference(SMD)of 0.83(95%CI:0.48-1.18).Similarly,other statistically significant parameters were mean transit time local with a SMD of 0.73(95%CI:0.20-1.27),peak enhancement with a SMD of 0.37(95%CI:0.03-0.70),area wash-in area under the curve with a SMD of 0.47(95%CI:0.13-0.81),wash-out area under the curve with a SMD of 0.55(95%CI:0.21-0.89)and wash-in and wash-out area under the curve with SMD of 0.51(95%CI:0.17-0.85).SMD resulted not significant in fall time and wash-in rate,but the latter presented a trend towards greater values in HCC compared to intrahepatic cholangiocarcinoma.CONCLUSION DCEUS could improve non-invasive diagnosis of HCC,leading to less liver biopsy and early treatment.This quantitative analysis needs to be applied on larger cohorts to confirm these preliminary results.
基金the Ethic Committee of Wuxi People's Hospital(No.KY17071).
文摘BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions.
文摘This editorial discusses the manuscript by Di Maria et al,published in the recent issue of the World Journal of Cardiology.We here focus on the still elusive pathophysiological mechanisms underlying cardio-renal syndrome(CRS),despite its high prevalence and the substantial worsening of both kidney function and heart failure.While the measure of right atrial pressure through right cardiac catheterization remains the most accurate albeit invasive and costly procedure,integrating bedside ultrasound into diagnostic protocols may substantially enhance the staging of venous congestion and guide therapeutic decisions.In particular,with the assessment of Doppler patterns across multiple venous districts,the Venous Excess Ultrasound(VExUS)score improves the management of fluid overload and provides insight into the underlying factors contributing to cardio-renal interactions.Integrating specific echocardiographic parameters,particularly those concerning the right heart,may thus improve the VExUS score sensitivity,offering perspective into the nuanced comprehension of cardio-renal dynamics.A multidisciplinary approach that consistently incorporates the use of ultrasound is emerging as a promising advance in the understanding and management of CRS.
文摘Objective: To explore the value of percutaneous ultrasonography combined with transvenous ultrasonography for accurate localization of sentinel lymph nodes and diagnosis of metastatic lymph nodes in patients with breast cancer. Methods: 18 cases of patients with breast cancer attending the Hainan General Hospital from May 2022 to June 2024 who were proposed to undergo axillary lymph node dissection were selected, and the ultrasonographic agent was injected subcutaneously through the areola on the 1st day before the operation, and the marker localization of the manifestation of the Sentinel lymph nodes and draw the lymphatic vessel alignment for drainage on the body surface, and record the manifestation of SLN by conventional ultrasound and dual ultrasonography. At the time of surgery, intraoperative melphalan localization was used to identify the SLN, the difference between the number of ultrasound and melphalan localization was observed, and resection was performed for pathological examination to determine whether they were metastatic or not. Results: There were 8 metastatic lymph nodes and 18 non-metastatic lymph nodes among 31 SLN. A total of 62 SLN were localized by intraoperative melphalan, of which 31 were consistent with ultrasound localization and 31 were not identified by ultrasound. The diagnostic sensitivity of SLN metastasis diagnosed by transcutaneous ultrasonography was 62.50%, specificity was 91.30%, positive predictive value was 71.43%, negative predictive value 87.50%, accuracy was 83.87%, and the AUC was 0.769;the diagnostic sensitivityof transvenous ultrasonography diagnosed was 75.00%, specificity was 75.00%, and the accuracy was 83.87%, 75.00%, specificity 91.30%, positive predictive value 75.00%, negative predictive value 91.30%, accuracy 87.10%, AUC 0.832;dual ultrasonography diagnostic sensitivity 87.50%, specificity 91.30%, positive predictive value 77.78%, negative predictive value 95.45%, accuracy 90.32%. The AUC was 0.894. Conclusion: Transcutaneous ultrasonography combined with transvenous ultrasonography can accurately localize sentinel lymph nodes and improve the sensitivity and accuracy of the diagnosis of metastatic SLN.
文摘The gallbladder(GB)is a susceptible organ,prone to various pathologies that can be identified using different imaging techniques.Transabdominal ultrasound(TUS)is typically the initial diagnostic method due to its numerous well-established advantages.However,in cases of uncertainty or when a definitive diagnosis cannot be established,computed tomography(CT)or magnetic resonance imaging may be employed to provide more detailed information.Nevertheless,CT scans may sometimes offer inadequate spatial resolution,which can limit the differentiation of GB lesions,particularly when smaller yet clinically relevant abnormalities are involved.Conversely,endoscopic ultrasound(EUS)provides higher frequency compared to TUS,superior spatial resolution,and the option for contrast-enhanced harmonic imaging,enabling a more comprehensive examination.Thus,EUS can serve as a supplementary tool when conventional imaging methods are insufficient.This review will describe the standard EUS examination of the GB,focusing on its endosonographic characteristics in various GB path-ologies.
文摘Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and affects the response to treatment of patients with hepatocellular carcinoma(HCC).For these reasons,identifying an easy-to-perform method to assess sarcopenia in is a key element in the optimization of care in this patient population.Assessment of muscle mass by computed tomography is considered the standard of care for the diagnosis of sarcopenia,but exposure to radiation and high costs limit its application in this setting,especially for repeated assessments.We believe that ultrasound,a cheap and harmless technique also used for HCC screening in cirrhotic patients,could have an expanding role in the diagnosis and follow-up of sarcopenia in these patients.
文摘In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary drainage are usually guided by fluoroscopy or transcutaneous ultrasound,endoscopic ultrasound(EUS),or both.Endoscopic retrograde cholangiopancreatography(ERCP)has been primarily recommended for the management of biliary obstruction,while EUS-guided biliary drainage and percutaneous transhepatic biliary drainage(PTBD)are alternative choices for cases where ERCP has failed or is impossible.PTBD is limited by shortcomings of a higher rate of adverse events,more reinterventions,and severe complications.EUS-guided biliary drainage has a lower rate of adverse events than PTBD.EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent(ECE-LAMS)enables EUS-guided biliaryenteric anastomosis to be performed in a single step and does not require prior bile duct puncture or a guidewire.The present meta-analysis showed that ECELAMS has a high efficacy and safety in relieving biliary obstruction in general,although the results of LAMS depending on the site of biliary obstruction.This study has highlighted the latest advances with a larger sample-based comprehensive analysis.
文摘Objectives: To demonstrate the contribution and relevance of ETFs through the study of 1000 examination reports carried out in the medical imaging departments of the OUAGADOUGOU CHU. Material and method: Analytical descriptive study with retrospective collection, extended from 1st January 2020 to 1st January 2022. Results: Of the 1000 transfontanellar ultrasound reports, the mean age of patients was 7.61 +/ 7.5 days, with extremes of zero and 28 days. Sex was specified in 989 cases. Males accounted for 54.49% and females for 45.51%. 555 transfontanellar ultrasound were performed in 2020. 441 in 2021 and 4 in 2022. 61.9% of transfontanellar ultrasound were performed at the Bogodogo University Hospital, 205 at Charles de Gaulle and 176 at Tengandogo. Indications for transfontanellar ultrasound were dominated by neonatal distress (65.8%), followed by convulsions (10.2%) and prematurity (9.1%). Transfontanellar ultrasound was normal in 570 cases (57%) and abnormal in 430 cases (43%). Abnormalities were dominated by haemorrhage and ischaemic lesions in 66.28% (285) and 21.63% (93) of cases respectively. In the group of normal transfontanellar ultrasound, neonatal distress represented 59.65% of indications and prematurity 10.7% of indications. As for abnormal transfontanellar ultrasound, neonatal suffering accounted for 73.95% of indications and convulsions for 12.56%. The average age ofpatients with an abnormal transfontanellar ultrasound was 8.74 days +/ 7.89 days. The indication for investigations was relevant in 42.2% of cases and irrelevant in 57.8%;of the transfontanellar ultrasound with relevant indications, 0.71 were normal and 99.29 abnormal;of the transfontanellar ultrasound with irrelevant indications, the transfontanellar ultrasound was normal in 98.1% and abnormal in 1.9%. Conclusion: Transfontanellar ultrasound is an important part of ultrasound in current practice. Haemorrhage, anoxic-ischaemic lesions and hydrocephalus are the most frequent pathologies found by this technique in newborns. Whether or not the examinations were normal depended on the appropriateness of the prescription.
基金National Natural Science Foundation of China(Grant Nos.51821003,52175524,61704158)the Natural Science Foundation of Shanxi Province(Grant No.202103021224206)Shanxi"1331 Project"Key Subjects Construction to provide fund for conducting experiments。
文摘In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment.