Based on the pressure regulation circuit adopting electro-hydraulic proportional relief valve to control tension, a new type of electro-hydraulic compound control circuit with throttle control unit is presented, which...Based on the pressure regulation circuit adopting electro-hydraulic proportional relief valve to control tension, a new type of electro-hydraulic compound control circuit with throttle control unit is presented, which can obtain optimal dynamic damping ratio through real-time altering pressure-flow gain of the throttle control unit, improve the dynamic characteristic of tension follow-up control for the tension system with high inertia loads. Moreover, the characteristic when the cable linear velocity variation causes change of tension is investigated, and a compound control strategy is proposed. The theoretical analysis and experimental results show that the electro-hydraulic compound control circuit is effective and the characteristic of the compound control strategy is satisfactory.展开更多
Calculated results of inertia moment of turbo-generator rotor can be quite different by methods used in load rejection tests. In view of fluctuation features of rotor speed rise curve during load rejection tests, the ...Calculated results of inertia moment of turbo-generator rotor can be quite different by methods used in load rejection tests. In view of fluctuation features of rotor speed rise curve during load rejection tests, the measurement principle of rotor inertia moment was expounded. Based on the measured data in load rejection tests for an imported type of domestic 300-MW generating unit, the rotor speed rise curve was fitted with three kinds of functions to get initial runup rate, but the obtained results differed a lot from each other. According to analysis on the mechanism of rotor speed rise, m=2 consecutive points averaging or FFT (Fast Fourier Transform) smoothing technology was introduced to process test data, and then the initial runup rate was determined by the method of linear fitting of rotor speed in the range of governing valve closing time. Although the obtained curves had a fluctuating shape, the results of rotor inertia moment for 50% and 100% load rejection tests were of good consistency.展开更多
基金This project is supported by National Natural Science Foundation of China (No.50475105).
文摘Based on the pressure regulation circuit adopting electro-hydraulic proportional relief valve to control tension, a new type of electro-hydraulic compound control circuit with throttle control unit is presented, which can obtain optimal dynamic damping ratio through real-time altering pressure-flow gain of the throttle control unit, improve the dynamic characteristic of tension follow-up control for the tension system with high inertia loads. Moreover, the characteristic when the cable linear velocity variation causes change of tension is investigated, and a compound control strategy is proposed. The theoretical analysis and experimental results show that the electro-hydraulic compound control circuit is effective and the characteristic of the compound control strategy is satisfactory.
文摘Calculated results of inertia moment of turbo-generator rotor can be quite different by methods used in load rejection tests. In view of fluctuation features of rotor speed rise curve during load rejection tests, the measurement principle of rotor inertia moment was expounded. Based on the measured data in load rejection tests for an imported type of domestic 300-MW generating unit, the rotor speed rise curve was fitted with three kinds of functions to get initial runup rate, but the obtained results differed a lot from each other. According to analysis on the mechanism of rotor speed rise, m=2 consecutive points averaging or FFT (Fast Fourier Transform) smoothing technology was introduced to process test data, and then the initial runup rate was determined by the method of linear fitting of rotor speed in the range of governing valve closing time. Although the obtained curves had a fluctuating shape, the results of rotor inertia moment for 50% and 100% load rejection tests were of good consistency.