In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is...In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is proposed in the paper,which takes into account the network loss correction for the extreme cold region.Firstly,an electro-thermal model is introduced to reflect the effect of temperature on conductor resistance and to correct the results of active network loss calculation;secondly,a two-stage multi-objective two-stage decentralised wind power siting and capacity allocation and reactive voltage optimisation control model is constructed to take account of the network loss correction,and the multi-objective multi-planning model is established in the first stage to consider the whole-life cycle investment cost of WTGs,the system operating cost and the voltage quality of power supply,and the multi-objective planning model is established in the second stage.planning model,and the second stage further develops the reactive voltage control strategy of WTGs on this basis,and obtains the distribution network loss reduction method based on WTG siting and capacity allocation and reactive power control strategy.Finally,the optimal configuration scheme is solved by the manta ray foraging optimisation(MRFO)algorithm,and the loss of each branch line and bus loss of the distribution network before and after the adoption of this loss reduction method is calculated by taking the IEEE33 distribution system as an example,which verifies the practicability and validity of the proposed method,and provides a reference introduction for decision-making for the distributed energy planning of the distribution network.展开更多
A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper,capable of operating with minimum supply voltage at1...A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper,capable of operating with minimum supply voltage at1 V.A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current,which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier.A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted,which not only improves the sense window enhancing read precision but also saves power consumption.The sense amplifier was implemented in a flash realized in 90 run flash technology.Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125℃.展开更多
This paper proposes a stochastic programming(SP)method for coordinated operation of distributed energy resources(DERs)in the unbalanced active distribution network(ADN)with diverse correlated uncertainties.First,the t...This paper proposes a stochastic programming(SP)method for coordinated operation of distributed energy resources(DERs)in the unbalanced active distribution network(ADN)with diverse correlated uncertainties.First,the threephase branch flow is modeled to characterize the unbalanced nature of the ADN,schedule DER for three phases,and derive a realistic DER allocation.Then,both active and reactive power resources are co-optimized for voltage regulation and power loss reduction.Second,the battery degradation is considered to model the aging cost for each charging or discharging event,leading to a more realistic cost estimation.Further,copulabased uncertainty modeling is applied to capture the correlations between renewable generation and power loads,and the twostage SP method is then used to get final solutions.Finally,numerical case studies are conducted on an IEEE 34-bus three-phase ADN,verifying that the proposed method can effectively reduce the system cost and co-optimize the active and reactive power.展开更多
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit....A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%.展开更多
基金supported by the National Natural Science Foundation of China(52177081).
文摘In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is proposed in the paper,which takes into account the network loss correction for the extreme cold region.Firstly,an electro-thermal model is introduced to reflect the effect of temperature on conductor resistance and to correct the results of active network loss calculation;secondly,a two-stage multi-objective two-stage decentralised wind power siting and capacity allocation and reactive voltage optimisation control model is constructed to take account of the network loss correction,and the multi-objective multi-planning model is established in the first stage to consider the whole-life cycle investment cost of WTGs,the system operating cost and the voltage quality of power supply,and the multi-objective planning model is established in the second stage.planning model,and the second stage further develops the reactive voltage control strategy of WTGs on this basis,and obtains the distribution network loss reduction method based on WTG siting and capacity allocation and reactive power control strategy.Finally,the optimal configuration scheme is solved by the manta ray foraging optimisation(MRFO)algorithm,and the loss of each branch line and bus loss of the distribution network before and after the adoption of this loss reduction method is calculated by taking the IEEE33 distribution system as an example,which verifies the practicability and validity of the proposed method,and provides a reference introduction for decision-making for the distributed energy planning of the distribution network.
基金Project supported by the National Natural Science Fundation of China(No.61376028)
文摘A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper,capable of operating with minimum supply voltage at1 V.A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current,which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier.A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted,which not only improves the sense window enhancing read precision but also saves power consumption.The sense amplifier was implemented in a flash realized in 90 run flash technology.Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125℃.
文摘This paper proposes a stochastic programming(SP)method for coordinated operation of distributed energy resources(DERs)in the unbalanced active distribution network(ADN)with diverse correlated uncertainties.First,the threephase branch flow is modeled to characterize the unbalanced nature of the ADN,schedule DER for three phases,and derive a realistic DER allocation.Then,both active and reactive power resources are co-optimized for voltage regulation and power loss reduction.Second,the battery degradation is considered to model the aging cost for each charging or discharging event,leading to a more realistic cost estimation.Further,copulabased uncertainty modeling is applied to capture the correlations between renewable generation and power loads,and the twostage SP method is then used to get final solutions.Finally,numerical case studies are conducted on an IEEE 34-bus three-phase ADN,verifying that the proposed method can effectively reduce the system cost and co-optimize the active and reactive power.
基金This research was supported by the Science and Technology Plan Project of Sichuan Province(No.21YYJC3324)the Science and Technology Plan Project of Sichuan Province(No.2022YFQ0104).
文摘A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%.