Design method of split planar resonant inductor in 1 kV SiC logical link control(LLC)converter is proposed,which ensures the converter power density of 93.59 W/in^3 and peak efficiency of 95.73%.Split resonant inducto...Design method of split planar resonant inductor in 1 kV SiC logical link control(LLC)converter is proposed,which ensures the converter power density of 93.59 W/in^3 and peak efficiency of 95.73%.Split resonant inductor helps to provide symmetrical resonant current by symmetrical impedance,and improves the distortion of resonant current,which ensures the efficiency of the whole converter.An interleaved winding connecting scheme improves the power density of the planar magnets,which contributes to power density improvement.Design method and calculation process of such split planar resonant inductor are provided.To verify the feasibility of the proposed design method,a 1 kV/48 V 6.6 kW,210 k Hz SiC LLC prototype was built,and the experimental results are given.展开更多
LLC谐振变换器由于具有良好的软开关特性和电气隔离能力,在近年来被广泛应用于高压、大功率、中/高频电能变换领域。现有的高压器件受开关特性的制约,需要选取较大的死区时间保证电路中开关桥臂的安全可靠工作,从而会对LLC谐振变换器的...LLC谐振变换器由于具有良好的软开关特性和电气隔离能力,在近年来被广泛应用于高压、大功率、中/高频电能变换领域。现有的高压器件受开关特性的制约,需要选取较大的死区时间保证电路中开关桥臂的安全可靠工作,从而会对LLC谐振变换器的软开关实现产生影响。主要研究了大死区时间对LLC谐振变换器软开关特性的影响规律,分别从开关管安全工作、结电容放电和反并联二极管续流3个因素出发,定量推导确保全功率范围内软开关实现的死区设置区间,进而提出死区时间的优化设计方法。最后,搭建了基于6.5 kV/250 A IGBT的150 kW大功率电力电子变压器样机,通过分析和测量不同功率等级下LLC谐振变换器的软开关实现情况,验证所提死区时间设计方法的有效性。展开更多
基金supported by the National Key Research and Development Program of China (2018YFB0904101)Science and Technology Project of State Grid (SG SGHB0000KXJS1800685)
文摘Design method of split planar resonant inductor in 1 kV SiC logical link control(LLC)converter is proposed,which ensures the converter power density of 93.59 W/in^3 and peak efficiency of 95.73%.Split resonant inductor helps to provide symmetrical resonant current by symmetrical impedance,and improves the distortion of resonant current,which ensures the efficiency of the whole converter.An interleaved winding connecting scheme improves the power density of the planar magnets,which contributes to power density improvement.Design method and calculation process of such split planar resonant inductor are provided.To verify the feasibility of the proposed design method,a 1 kV/48 V 6.6 kW,210 k Hz SiC LLC prototype was built,and the experimental results are given.
文摘LLC谐振变换器由于具有良好的软开关特性和电气隔离能力,在近年来被广泛应用于高压、大功率、中/高频电能变换领域。现有的高压器件受开关特性的制约,需要选取较大的死区时间保证电路中开关桥臂的安全可靠工作,从而会对LLC谐振变换器的软开关实现产生影响。主要研究了大死区时间对LLC谐振变换器软开关特性的影响规律,分别从开关管安全工作、结电容放电和反并联二极管续流3个因素出发,定量推导确保全功率范围内软开关实现的死区设置区间,进而提出死区时间的优化设计方法。最后,搭建了基于6.5 kV/250 A IGBT的150 kW大功率电力电子变压器样机,通过分析和测量不同功率等级下LLC谐振变换器的软开关实现情况,验证所提死区时间设计方法的有效性。