期刊文献+
共找到3,852篇文章
< 1 2 193 >
每页显示 20 50 100
Steady-state voltage-control method considering large-scale wind-power transmission using half-wavelength transmission lines 被引量:3
1
作者 Hao Tian Hongzheng Liu +3 位作者 Huan Ma Pengfei Zhang Xiaohui Qin Changhui Ma 《Global Energy Interconnection》 EI CAS CSCD 2021年第3期239-250,共12页
Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering ... Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering largescale wind-power transmission.First,the unique voltage characteristics of half-wavelength lines are deduced based on the distributed parameter model.In the secondary voltage-control level,reactive power-transmission limits of half-wavelength lines are introduced as another control objective except for tracing the pilot bus voltage reference.Considering the uncertainty and fluctuation of wind power,the overvoltage risk-assessment method of half-wavelength lines is presented to determine specific voltage-control strategies.Simulation results demonstrate that the proposed voltage-control method delivers superior tracking performance according to a voltage reference value and prevents the overvoltage risk of halfwavelength lines effectively in different wind-power penetrations. 展开更多
关键词 Half-wavelength lines Secondary voltage control Wind-power transmission Reactive power regulation
下载PDF
Measurement and Simulation of Induced Voltage and Current on 110 KV Crossing Transmission Lines under UHV AC Transmission Lines
2
作者 Weiwei Pan Shoucheng Miu +2 位作者 Guangkai Yu Tian Wu Bo Zhang 《Energy and Power Engineering》 2017年第4期635-643,共9页
The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced... The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff. 展开更多
关键词 UHV AC transmission LINES CROSSING INDUCED voltage INDUCED CURRENT Field MEASUREMENT Simulation Calculation
下载PDF
An Exact Solution of Telegraph Equations for Voltage Monitoring of Electrical Transmission Line
3
作者 Daouda Konane Wend Yam Serge Boris Ouedraogo +3 位作者 Toussaint Tilado Guingane Abdoulaye Zongo Zacharie Koalaga François Zougmoré 《Energy and Power Engineering》 CAS 2022年第11期669-679,共11页
Telegraph equations are derived from the equations of transmission line theory. They describe the relationships between the currents and voltages on a portion of an electric line as a function of the linear constants ... Telegraph equations are derived from the equations of transmission line theory. They describe the relationships between the currents and voltages on a portion of an electric line as a function of the linear constants of the conductor (resistance, conductance, inductance, capacitance). Their resolution makes it possible to determine the variation of the current and the voltage as a function of time at each point of the line. By adopting a general sinusoidal form, we propose a new exact solution to the telegraphers’ partial differential equations. Different simulations have been carried out considering the parameter of the 12/20 (24) kV Medium Voltage Cable NF C 33,220. The curves of the obtained solution better fit the real voltage curves observed in the electrical networks in operation. 展开更多
关键词 Telegraph Equation Electric Network voltage Variation Electrical transmission Lines Analytical Solution
下载PDF
Application HELAVA Digital Photogrammetry System in Extra High Voltage Transmission Line Path Optimization
4
《Electricity》 1999年第1期45-48,共4页
关键词 PATH Application HELAVA Digital Photogrammetry System in Extra High voltage transmission Line Path Optimization FIGURE
下载PDF
The Development of High Voltage Overhead Transmission Line Technology in China
5
《Electricity》 1999年第1期38-41,共4页
关键词 The Development of High voltage Overhead transmission Line Technology in China
下载PDF
Radio Interference Characteristic of Ultra-high Voltage AC Transmission Lines by Using Stochastic Modeling
6
作者 HE Wangling WAN Baoquan +3 位作者 PEI Chunming ZHANG Jiangong HE Junjia GUO Haozhou 《高电压技术》 EI CAS CSCD 北大核心 2013年第10期2438-2444,共7页
For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplit... For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line. 展开更多
关键词 特高压输电线路 交流输电线路 无线电干扰 随机建模 干扰特性 概率论与数理统计 电力传输系统 平稳随机过程
下载PDF
Analysis of field coupling to transmission lines with random rotation over the ground 被引量:1
7
作者 谢海燕 李勇 +1 位作者 乔海亮 王建国 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期171-176,共6页
In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption ... In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption of small rotation quantity, the factors affecting the induced voltage and their effects are analyzed and then an efficient method to calculate the average voltage is presented when the distribution of the random rotation angles is uniform in [-π, π]. The results show that voltage variation is mainly due to the change of the source term. The effects of the source term increase linearly with the magnitude of the incident wave, change periodically with the rotation angle, and are larger in the high frequency range than in the low frequency range. The results show that the average voltages obtained by the proposed method agree well with those via the Monte Carlo method and the proposed method is much more efficient. The results also imply that the effect of random rotation is more important than that of random translation. 展开更多
关键词 electromagnetic interference induced voltage RANDOMNESS statistical analysis transmission line
下载PDF
MMC-MTDC Transmission System with Partially Hybrid Branches 被引量:5
8
作者 Yongyang Chen Shangzhi Pan +3 位作者 Meng Huang Zili Zhu Yushuang Liu Xiaoming Zha 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期124-132,共9页
This paper proposes a hybrid submodule modular multilevel converter(MMC)topology which is suitable for multi terminal direct current(MTDC)transmission systems.Each arm of the proposed MMC topology consists of a half-b... This paper proposes a hybrid submodule modular multilevel converter(MMC)topology which is suitable for multi terminal direct current(MTDC)transmission systems.Each arm of the proposed MMC topology consists of a half-bridge submodule(HBSM)branch and two parallel full-bridge submodule(FBSM)branches.Comparing with the conventional MTDC transmission system,the proposed topology can selectively block the DC fault current and isolate the corresponding fault line without expensive DC circuit breakers(DCCBs).Thus,the influence range of the DC fault can be reduced and the reliability of the power supply can be improved as well.The corresponding modulation and voltage balancing strategies are developed for the proposed hybrid MMC topology.The feasibility of the proposed topology and control strategy is verified in the MATLAB/Simulink simulation. 展开更多
关键词 Hybrid modular multilevel converter multi terminal networks high voltage dc(HVDC)transmission
下载PDF
Three-Dimensional Analysis of Melanosomes Isolated from B16 Melanoma Cells by Using Ultra High Voltage Electron Microscopy 被引量:1
9
作者 Shuuichi Akazaki Toshie Takahashi +7 位作者 Yujiro Nakano Tomoki Nishida Hirotarou Mori Akio Takaoka Hitomi Aoki Huayua Chen Takahiro Kunisada Kenzo Koike 《Microscopy Research》 2014年第1期1-8,共8页
Melanosomes, isolated by centrifugal separation from culture broth of B16 melanoma cells derived from mouse, were observed by scanning electron microscopy (SEM), and by transmission electron microscopy (TEM). Some int... Melanosomes, isolated by centrifugal separation from culture broth of B16 melanoma cells derived from mouse, were observed by scanning electron microscopy (SEM), and by transmission electron microscopy (TEM). Some interesting structural features were found inside and outside of the melanosomes. By SEM observation, the melanosomes were ellipsoid shape, their surface was not smooth and was covered with rough substructure, 10 to 20 nm particles. By TEM, uneven structure and micro particles were observed in the melanosomes. Furthermore, three-dimensional analysis was tried by using the ultra-high voltage electron microscopy(UHVEM). Micrographs of the melanosomes were taken at various tilted angles by UHVEM, after preparing 500 nm thickness specimens stained with lead citrate. From the micrographs collected, the three-dimensional structures were reconstructed by using i-mode software. Melanin stained by lead and non stained parts was clearly observed in the reconstructed structure. Non stained parts were round, regular size, and distributed widely in the melanosomes. 展开更多
关键词 B16 MELANOMA MELANOSOME Scanning ELECTRON MICROSCOPY transmission ELECTRON MICROSCOPY Ultra High voltage ELECTRON MICROSCOPY Three-Dimensional Structure
下载PDF
New DDSCR structure with high holding voltage for robust ESD applications 被引量:1
10
作者 周子杰 金湘亮 +1 位作者 汪洋 董鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期529-539,共11页
A novel dual direction silicon-controlled rectifier(DDSCR)with an additional P-type doping and gate(APGDDSCR)is proposed and demonstrated.Compared with the conventional low-voltage trigger DDSCR(LVTDDSCR)that has posi... A novel dual direction silicon-controlled rectifier(DDSCR)with an additional P-type doping and gate(APGDDSCR)is proposed and demonstrated.Compared with the conventional low-voltage trigger DDSCR(LVTDDSCR)that has positive and negative holding voltages of 13.371 V and 14.038 V,respectively,the new DDSCR has high positive and negative holding voltages of 18.781 V and 18.912 V in a single finger device,respectively,and it exhibits suitable enough positive and negative holding voltages of 14.60 V and 14.319 V in a four-finger device for±12-V application.The failure current of APGDDSCR is almost the same as that of LVT-DDSCR in the single finger device,and the four-finger APGDDSCR can achieve positive and negative human-body model(HBM)protection capabilities of 22.281 kV and 23.45 kV,respectively,under 40-V voltage of core circuit failure,benefitting from the additional structure.The new structure can generate a snapback voltage on gate A to increase the current gain of the parasitic PNP in holding voltage.Thus,a sufficiently high holding voltage increased by the structure can ensure that a multi-finger device can also reach a sufficient holding voltage,it is equivalent to solving the non-uniform triggering problem of multi-finger device.The operating mechanism and the gate voltage are both discussed and verified in two-dimensional(2D)simulation and experiemnt. 展开更多
关键词 dual direction silicon-controlled rectifier(DDSCR) failure current snapback gate voltage simulation transmission line pulsing(TLP)
下载PDF
Simulation Analysis on Lightning Accident of ± 500 kV DC Transmission Line Based on ATP-EMTP 被引量:3
11
作者 FU Jin SIMA Wen-xia +2 位作者 YANG Qing YANG Li-bin LI Zhi-tai 《高电压技术》 EI CAS CSCD 北大核心 2009年第4期802-808,共7页
关键词 高压电技术 闪电 意外事故 传输线
下载PDF
A low-power Rijndael S-Box based on pass transmission gate and composite field arithmetic 被引量:2
12
作者 ZENG Yong-hong ZOU Xue-cheng LIU Zheng-lin LEI Jian-ming 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第10期1553-1559,共7页
Using composite field arithmetic in Galois field can result in the compact Rijndael S-Box. However, the power con- sumption of this solution is too large to be used in resource-limited embedded systems. A full-custom ... Using composite field arithmetic in Galois field can result in the compact Rijndael S-Box. However, the power con- sumption of this solution is too large to be used in resource-limited embedded systems. A full-custom hardware implementation of composite field S-Box is proposed for these targeted domains in this paper. The minimization of power consumption is implemented by optimizing the architecture of the composite field S-Box and using the pass transmission gate (PTG) to realize the logic functions of S-Box. Power simulations were performed using the netlist extracted from the layout. HSPICE simulation results indicated that the proposed S-Box achieves low power consumption of about 130 μW at 10 MHz using 0.25 μm/2.5 V technology, while the consumptions of the positive polarity reed-muller (PPRM) based S-Box and composite field S-Box based on the conventional CMOS logic style are about 240 μW and 420 μW, respectively. The simulations also showed that the presented S-Box obtains better low-voltage operating property, which is clearly relevant for applications like sensor nodes, smart cards and radio frequency identification (RFID) tags. 展开更多
关键词 合成域 全定制 低能量消耗 传输门电路
下载PDF
Research on the Long-distance Transmission
13
作者 Xueli Wu Xiuyuan Yang +1 位作者 Hong Shen Qinyong Zhou 《Energy and Power Engineering》 2013年第4期1293-1297,共5页
In view of the imbalanced distribution of power load and resources, including the status of “electric shortage” in some cities in our country, the article discusses the long-distance transmission technology. It main... In view of the imbalanced distribution of power load and resources, including the status of “electric shortage” in some cities in our country, the article discusses the long-distance transmission technology. It mainly analyzed two ways of the long-distance transmission: UHV AC transmission and UHV DC transmission. The fractional frequency transmission technology and half wavelength AC transmission technology of AC transmission are introduced. Some key technologies of long-distance transmission are described. It has a guess for long-distance transmission future direction. 展开更多
关键词 Energy LONG-DISTANCE Ultra-high voltage (UHV) ALTERNATING CURRENT (AC) Direct CURRENT (DC) transmission
下载PDF
Switching Impulse Strength of ±800 kV UHVDC Transmission Line Air Gap Insulation Under High Altitude Condition 被引量:3
14
作者 LIAO Yongli GAO Chao +2 位作者 LI Ruihai WANG Guoli MA Yi 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3161-3165,共5页
关键词 高压直流输电线路 缺口冲击强度 空气间隙 绝缘特性 开关脉冲 高海拔 伏特 平面布置
下载PDF
Optimum Load Shedding in Power System Strategies with Voltage Stability Indicators
15
作者 P.V. RAJ M. SUDHAKARAN 《Engineering(科研)》 2010年第1期12-21,共10页
An optimal load shedding strategy for power systems with optimum location and quantity of load to be shed is presented in this paper. The problem of load shedding for avoiding the existence of voltage instability in p... An optimal load shedding strategy for power systems with optimum location and quantity of load to be shed is presented in this paper. The problem of load shedding for avoiding the existence of voltage instability in power systems is taken as a remedial action during emergency state in transmission and distribution sector.Optimum location of loads to be shed is found together with their optimum required quantity. L-Indicator index is in used for this purpose with a modified new technique. Applications to be standard 6 bus Ward-Hale test system and IEEE – 14 bus system are presented to validate the applicability of the proposed technique to any system of any size. 展开更多
关键词 Load SHEDDING voltage INSTABILITY POWER systems transmission and Distribution POWER system
下载PDF
Aeolian vibration control measures for ground wires of Han River long span transmission lines
16
作者 叶志雄 《Journal of Chongqing University》 CAS 2009年第1期50-56,共7页
Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conduct... Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conductor self-damping,and the damper dissipated power. Meanwhile,we built a theoretical mechanical model of β wire dampers and derived energy dissipation calculation formulae. This permits the vibration energy dissipated by β wire dampers can be considered in the energy balance method. Then,we developed a computer program based on the improved energy balance method using Matlab,and analyzed UHV long span ground wires of the Han River long span project in P. R. China. The results show that the combination of β wire dampers and Stockbridge dampers can reduce vibration of UHV long span transmission lines,which provides a reference for research and construction of UHV engineering projects. 展开更多
关键词 振动控制 输电线路 大跨越 汉江 地线 中华人民共和国 计算机程序 理论力学模型
下载PDF
Influences of 500 kV Transmission Lines on Wetland Ecosystem and Its Protective Countermeasures--A Case Study of the Lake Wetland Natural Reserve along the Yangtze River in Anqing City
17
作者 Xia Shangguang Zhao Yuan 《Meteorological and Environmental Research》 CAS 2016年第4期17-22,共6页
The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric fiel... The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric field intensity(PFEFI),power frequency magnetic field intensity(PFMFI),radio interference,construction noise,vegetation destruction and the influence on water quality were investigated and monitored,and the influences of PFEFI,PFMFI,radio interference and construction noise on wild animals,especially the habitats and migration of birds were mainly researched.The direct and indirect influences on the surrounding environment as well as plants and animals in sensitive areas were analyzed and predicted.The results firstly showed there existed a 182 400m^3 stereo-space(PFEFI>4kV/m)which made flying birds unsafe under the lowest height 11 mof the lines,which fills the gap in the research of this field.Finally,some operational protection countermeasures were put forward at the current technical level to achieve the win-win goal of economic development and natural protection. 展开更多
关键词 Ultra-high-voltage transmission line Electromagnetic pollution LAKE WETLAND ECOSYSTEM safety Protective measures China
下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
18
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
Design of Power Supply for On-line Monitoring System of Transmission Lines
19
作者 Kai Chen Zi-jian Zhao +2 位作者 Yu-ning Zhang Yang-chun Cheng Yuan Dai 《Energy and Power Engineering》 2013年第4期570-574,共5页
This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil c... This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission. 展开更多
关键词 Monitoring System POWER Supply of HIGH-voltage transmission Line Draw-out POWER Coil SINGLE-CHIP MICROCOMPUTER
下载PDF
低频电压下含纤维素颗粒变压器油绝缘特性及影响因素 被引量:3
20
作者 刘云鹏 赵家莹 +2 位作者 刘贺晨 赵涛 尹子澳 《电工技术学报》 EI CSCD 北大核心 2024年第4期1198-1207,共10页
低频变压器是低频输电系统中的关键设备,低频电压下的绝缘特性对其设计及运行具有重要意义。该文为了研究低频电压下含纤维素颗粒的变压器油的绝缘特性,分别研究20、30、40、50 Hz四种频率交流电压下不同纤维素颗粒度(低、中、高)水平... 低频变压器是低频输电系统中的关键设备,低频电压下的绝缘特性对其设计及运行具有重要意义。该文为了研究低频电压下含纤维素颗粒的变压器油的绝缘特性,分别研究20、30、40、50 Hz四种频率交流电压下不同纤维素颗粒度(低、中、高)水平的变压器油击穿特性。同时,通过仿真及试验分析不同频率下变压器油中纤维素颗粒运动及积聚过程。研究结果表明,交流电压频率对变压器油中纤维素颗粒的成桥特性及击穿电压具有显著影响。随着频率的降低,纤维素颗粒向电极移动速度变慢并难以黏附在电极表面,减缓了纤维素颗粒在电极表面的积聚过程及杂质小桥的形成速度。相同频率交流电压下,变压器油击穿电压均随颗粒物浓度的升高而降低;相同纤维素颗粒浓度下,变压器油击穿电压随着频率的降低而增大。研究结果为低频变压器的设计及运行维护提供了基础数据支撑。 展开更多
关键词 变压器油 交流电压 低频输电 纤维素颗粒 运动
下载PDF
上一页 1 2 193 下一页 到第
使用帮助 返回顶部