To date no analytical solution of the pile ultimate lateral capacity for the general c–φ soil has been obtained. In the present study, a new dimensionless embedded ratio was proposed and the analytical solutions of ...To date no analytical solution of the pile ultimate lateral capacity for the general c–φ soil has been obtained. In the present study, a new dimensionless embedded ratio was proposed and the analytical solutions of ultimate lateral capacity and rotation center of rigid pile in c–φ soils were obtained. The results showed that both the dimensionless ultimate lateral capacity and dimensionless rotation center were the univariate functions of the embedded ratio. Also,the ultimate lateral capacity in the c–φ soil was the combination of the ultimate lateral capacity(f;) in the clay, and the ultimate lateral capacity(f;) in the sand. Therefore, the Broms chart for clay, solution for clay(φ=0) put forward by Poulos and Davis, solution for sand(c=0) obtained by Petrasovits and Awad, and Kondner’s ultimate bending moment were all proven to be the special cases of the general solution in the present study. A comparison of the field and laboratory tests in 93 cases showed that the average ratios of the theoretical values to the experimental value ranged from 0.85 to 1.15. Also, the theoretical values displayed a good agreement with the test values.展开更多
Based on Mindlin stress solution, a numerical computational method was proposed to calculate the stresses in the ground induced by side friction and the resistance of Y-shaped vibro-pile. The improved Terzaghi's a...Based on Mindlin stress solution, a numerical computational method was proposed to calculate the stresses in the ground induced by side friction and the resistance of Y-shaped vibro-pile. The improved Terzaghi's and ЪерезанцевВГ's methods for ultimate bearing capacity evaluation were proposed by considering the stress strength induced by friction resistance at pile head level of Y-pile. A new method to calculate the ultimate bearing capacity of Y-pile was also proposed based on the assumptions of soil failure mode at the tip of Y-pile and the use of Mohr-Coulomb soil yield criterion and Vesic compressive correction coefficient with the induced stresses in the ground. Based on the comparisons with the field static load test results, it is found that the improved Terzaghi's method gives higher ultimate capacity, while the other two methods shows good agreement with the field results.展开更多
This paper expatiated the field test of large diameter cast in place piles embedded in soft rock, including static loading test, high or low strain dynamic test, measurement of stresses and strains of pile body, and p...This paper expatiated the field test of large diameter cast in place piles embedded in soft rock, including static loading test, high or low strain dynamic test, measurement of stresses and strains of pile body, and pressure measurements between pile tip and soft rock. The relative in situ test problems are discussed. Based on the limit equilibrium theory and the load transfer equation, a synthesis method of analyzing the ultimate carrying capacity of single large diameter pile is put forward. The research results show that the key to determining the ultimate carrying capacity of single pile with a large diameter is the analysis of the intensity of soft rock.展开更多
It is disclosed a method for the stability analysis of foundation piles and piers subjected to lateral loading, both static and seismic conditions. The stability analysis for stratified soil is based upon the models o...It is disclosed a method for the stability analysis of foundation piles and piers subjected to lateral loading, both static and seismic conditions. The stability analysis for stratified soil is based upon the models of foundation soil-structure interaction and the Rankine's theory of earth passive pressure. In addition, its application is simpler and it can be solved using a spreadsheet. The procedure described in this work can be used in homogeneous soils as in stratified soils, considers the horizontal drag forces exerted by the soil mass against the foundation during an earthquake, can be used easily in the four pile and piers boundary cases, and considers the pore pressure generated in a fine saturated soil during an earthquake or during a rapid application of the horizontal load. The solution of two examples are shown, one in static condition and one in seismic condition, detailing the procedure step by step.展开更多
基金financially supported by the National Natural Science Foundation of China(Grant No.51379132)
文摘To date no analytical solution of the pile ultimate lateral capacity for the general c–φ soil has been obtained. In the present study, a new dimensionless embedded ratio was proposed and the analytical solutions of ultimate lateral capacity and rotation center of rigid pile in c–φ soils were obtained. The results showed that both the dimensionless ultimate lateral capacity and dimensionless rotation center were the univariate functions of the embedded ratio. Also,the ultimate lateral capacity in the c–φ soil was the combination of the ultimate lateral capacity(f;) in the clay, and the ultimate lateral capacity(f;) in the sand. Therefore, the Broms chart for clay, solution for clay(φ=0) put forward by Poulos and Davis, solution for sand(c=0) obtained by Petrasovits and Awad, and Kondner’s ultimate bending moment were all proven to be the special cases of the general solution in the present study. A comparison of the field and laboratory tests in 93 cases showed that the average ratios of the theoretical values to the experimental value ranged from 0.85 to 1.15. Also, the theoretical values displayed a good agreement with the test values.
文摘Based on Mindlin stress solution, a numerical computational method was proposed to calculate the stresses in the ground induced by side friction and the resistance of Y-shaped vibro-pile. The improved Terzaghi's and ЪерезанцевВГ's methods for ultimate bearing capacity evaluation were proposed by considering the stress strength induced by friction resistance at pile head level of Y-pile. A new method to calculate the ultimate bearing capacity of Y-pile was also proposed based on the assumptions of soil failure mode at the tip of Y-pile and the use of Mohr-Coulomb soil yield criterion and Vesic compressive correction coefficient with the induced stresses in the ground. Based on the comparisons with the field static load test results, it is found that the improved Terzaghi's method gives higher ultimate capacity, while the other two methods shows good agreement with the field results.
文摘This paper expatiated the field test of large diameter cast in place piles embedded in soft rock, including static loading test, high or low strain dynamic test, measurement of stresses and strains of pile body, and pressure measurements between pile tip and soft rock. The relative in situ test problems are discussed. Based on the limit equilibrium theory and the load transfer equation, a synthesis method of analyzing the ultimate carrying capacity of single large diameter pile is put forward. The research results show that the key to determining the ultimate carrying capacity of single pile with a large diameter is the analysis of the intensity of soft rock.
文摘It is disclosed a method for the stability analysis of foundation piles and piers subjected to lateral loading, both static and seismic conditions. The stability analysis for stratified soil is based upon the models of foundation soil-structure interaction and the Rankine's theory of earth passive pressure. In addition, its application is simpler and it can be solved using a spreadsheet. The procedure described in this work can be used in homogeneous soils as in stratified soils, considers the horizontal drag forces exerted by the soil mass against the foundation during an earthquake, can be used easily in the four pile and piers boundary cases, and considers the pore pressure generated in a fine saturated soil during an earthquake or during a rapid application of the horizontal load. The solution of two examples are shown, one in static condition and one in seismic condition, detailing the procedure step by step.