期刊文献+
共找到2,023篇文章
< 1 2 102 >
每页显示 20 50 100
Seismic performance of steel reinforced ultra high-strength concrete composite frame joints 被引量:5
1
作者 Yan Changwang Jia Jinqing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第3期439-448,共10页
To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens... To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens were designed and tested under low cyclically lateral load. The effects of the axial load ratio and volumetric stirrup ratio were studied on the characteristics of the frame joint performance including crack pattern, failure mode, ductility, energy dissipation capacity, strength degradation and rigidity degradation. It was found that all joint specimens behaved in a ductile manner with flexural-shear failure in the joint core region while plastic hinges appeared at the beam ends. The ductility and energy absorption capacity of joints increased as the axial load ratio decreased and the volumetric stirIup ratio increased. The displacement ductility coefficient and equivalent damping coefficient of the joints fell between the corresponding coefficients of the steel reinforced concrete (SRC) frame joint and RC frame joint. The axial load ratio and volumetric stirrup ratio have less influence on the strength degradation and more influence on the stiffness degradation. The stiffness of the joint degrades more significantly for a low volumetric stirrup ratio and high axial load ratio. The characteristics obtained from the SRUHSC composite frame joint specimens with better seismic performance may be a useful reference in future engineering applications. 展开更多
关键词 cyclical test axial load ratio volumetric stirrup ratio DUCTILITY strength degradation stiffness degradation steel reinforced ultra high strength concrete beam-column joint
下载PDF
Seismic Performance of Steel Reinforced Ultra High-strength Concrete Columns 被引量:1
2
作者 贾金青 《四川大学学报(工程科学版)》 EI CAS CSCD 北大核心 2009年第3期216-222,230,共8页
The seismic performance of steel reinforced ultra-high-strength concrete columns(SRSHC) with various shear-span ratios(λ) were studied through a series of experiments.The concrete compressive cube strength value of e... The seismic performance of steel reinforced ultra-high-strength concrete columns(SRSHC) with various shear-span ratios(λ) were studied through a series of experiments.The concrete compressive cube strength value of experimental specimens ranged from 92.9 MPa to 108.1 MPa.The main experimental variables affecting seismic performance of specimens were axial load ratio and stirrup reinforcement ratio.The columns(λ=2.75) subjected to low cyclic reversed lateral loads failed mainly in the flexural-shear mode failure and columns(λ≤2.0) subjected to low cyclic reversed lateral loads failed mainly in the shear mode failure.Shear force-displacement hysteretic curves and skeleton curves were drawn.Coefficient of the specimen displacement ductility was calculated.Experimental results indicate that ductility decreases with axial pressure ratio increasing,and increases with stirrup reinforcement ratio increasing.Limit values of axial pressure ratio and minimum stirrup reinforcement ratio of columns are proposed to satisfy definite ductility requirement.The suggested values provide a reference for engineering application and for the amendment of the current Chinese design code of steel reinforced concrete composite structures. 展开更多
关键词 建筑结构 建筑物 抗震设计 混凝土结构
下载PDF
Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete 被引量:7
3
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2014年第13期989-999,共11页
Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is perf... Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1]. 展开更多
关键词 Perfobond RIB CONNECTOR ultra high performance concrete Push-Out Test SHEAR Strength
下载PDF
Design of Eco-friendly Ultra-high Performance Concrete with Supplementary Cementitious Materials and Coarse Aggregate 被引量:4
4
作者 JIANG Jinyang ZHOU Wenjing +4 位作者 CHU Hongyan WANG Fengjuan WANG Liguo FENG Taotao GUO Dong 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2019年第6期1350-1359,共10页
Aiming to investigate the mix design of eco-friendly UHPC with supplementary cementitious materials and coarser aggregates, we comprehensively studied the workability, microstructure, porosity, compressive strength, f... Aiming to investigate the mix design of eco-friendly UHPC with supplementary cementitious materials and coarser aggregates, we comprehensively studied the workability, microstructure, porosity, compressive strength, flexural strength, and Young’s modulus of UHPC. Relationship between compressive strength and Young’s modulus was obtained eventually. It is found that the compressive strength, flexural strength, and Young’s modulus of UHPC increase by 19.01%, 10.81%, and 5.99%, respectively, when 40 wt% cement is replaced with supplementary cementitious materials. The relationship between compressive strength and Young’s modulus of UHPC is an exponential form. 展开更多
关键词 ultra-high perform ance concrete ECO-FRIENDLY POROSITY compressive strength flexural strength Young’s modulus
下载PDF
Development of Optimal Structural System for Hybrid Cable-Stayed Bridges Using Ultra High Performance Concrete 被引量:1
5
作者 Hee Seok Kim Young Jin Kim +1 位作者 Won Jong Chin Hyejin Yoon 《Engineering(科研)》 2013年第9期720-728,共9页
This study developed an optimal structural system for the hybrid cable-stayed bridge expected to have a durable lifetime of 200 years and of which major structural members are made of ultra high performance concrete (... This study developed an optimal structural system for the hybrid cable-stayed bridge expected to have a durable lifetime of 200 years and of which major structural members are made of ultra high performance concrete (UHPC) with 200 MPa-class compressive strength. This innovative cable-stayed bridge system makes it possible to reduce each of the construction and maintenance costs by 20% compared to the conventional concrete cable-stayed bridge by improving significantly the weight and durability of the bridge. Therefore, detail design is carried out considering a real 800 m cable-stayed bridge and the optimal structure of the hybrid cable-stayed bridge is proposed and verified. 展开更多
关键词 HYBRID CABLE-STAYED Bridge ultra high performance concrete (UHPC) OPTIMAL Structural System DURABILITY
下载PDF
Dynamic Mechanical Behaviour of Ultra-high Performance Fiber Reinforced Concretes 被引量:2
6
作者 赖建中 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第6期938-945,共8页
Ultra-high performance fiber reinforced concretes (UHPFRC) were prepared by replacing 60% of cement with ultra-fine industrial waste powder. The dynamic mechanical behaviour of UHPFRC with different fiber volume fra... Ultra-high performance fiber reinforced concretes (UHPFRC) were prepared by replacing 60% of cement with ultra-fine industrial waste powder. The dynamic mechanical behaviour of UHPFRC with different fiber volume fraction was researched on repeated compressive impact in four kinds of impact modes through split Hopkinson pressure bar (SHPB). The experimental results show that the peak stress and elastic modulus decrease and the strain rate and peak strain increase gradually with the increasing of impact times. The initial material damage increases and the peak stress of the specimen decreases from the second impact with the increasing of the initial incident wave. Standard strength on repeated impact is defined to compare the ability of resistance against repeated impact among different materials. The rate of reduction of standard strength is decreased by fiber reinforcement under repeated impact. The material damage is reduced and the ability of repeated impact resistance of UHPFRC is improved with the increasing of fiber volume fraction. 展开更多
关键词 ultra-high performance fiber reinforced concretes split Hopkinson pressurebar DYNAMIC repeated impact
下载PDF
Different Curing Systems on Mechanical Properties of Ultra-High Performance Concrete with Coarse Aggregate
7
作者 赵秋 杨明 +1 位作者 庄一舟 聂宇 《Journal of Donghua University(English Edition)》 EI CAS 2017年第4期492-497,共6页
High durability and high tensile strength makes ultra-high performance concrete( UHPC) an ideal material for bridges,while its early shrinkage in the construction of cast-in-situ mass concrete leads structure crack-ea... High durability and high tensile strength makes ultra-high performance concrete( UHPC) an ideal material for bridges,while its early shrinkage in the construction of cast-in-situ mass concrete leads structure crack-easily,which restricts the application of UHPC in deck system. Whether reasonable amount of coarse aggregate can influence the strength of UHPC and improve the shrinkage performance or reduce the cost is still in doubt. Besides,in order to improve its constructability and workability, whether autoclaved curing system of UHPC can be changed remains to be further researched. In response to these circumstances, a systematic experimental study on the strength of UHPC mixed with coarse aggregate in different ratios has been presented in this paper. The three curing systems,namely standard curing,180-200 ℃/1. 1 MPa autoclaved curing,and hot water curing were tested to reveal the relationship between UHPC's properties and curing systems,and the UHPC ' s microstructure was also preliminarily studied by scanning electron microscope( SEM). The experimental research can draw the following conclusions. Under the condition of the same mix ratio, autoclaved curing guarantees the highest compressive strength,followed by hot water curing and standard curing. The compressive strength of concrete increases with the temperature in the range of 25 to 90 ℃ hot water curing,and high temperature in precuring period can speed up the strength development of UHPC,but the sequence of precuring period does not obviously affect the results. In 90 ℃ hot water and autoclaved curing,the strength is over 150 MPa,and it has little relation with gravel ratio. While the value increases first and then decreases in a lower temperature curing with the increasing of gravel amount,even only about 80 MPa at room temperature. The strength increases moderately along with the increase of the curing age by standard curing,especially in the initial stage. 展开更多
关键词 ultra-high performance concrete(UHPC) coarse aggregate curing system STRENGTH MICROSTRUCTURE
下载PDF
Manufacturing Ultra High Performance Concretes by Silica Fume, Ultra Fine Fly Ash and Metakaolin Addition
8
作者 Tony Song Ion Dumitru Bob Bomstein 《材料科学与工程(中英文A版)》 2017年第3期136-142,共7页
关键词 超高性能混凝土 超细粉煤灰 偏高岭土 制造 氯离子扩散系数 超细高岭土 粉煤灰混凝土 混凝土配合比
下载PDF
Flexural Bond Behavior of Rebar in Ultra-High Performance Concrete Beams Considering Lap-Splice Length and Cover Depth
9
作者 Seongjun Kim Jungwoo Lee +1 位作者 Changbin Joh Imjong Kwahk 《Engineering(科研)》 2016年第3期116-129,共14页
This study intends to find out the correlation between the cover depth and the bond characteristics of UHPC through pull-out tests of UHPC specimens with different cover depths and bond tests of rebar using flexural m... This study intends to find out the correlation between the cover depth and the bond characteristics of UHPC through pull-out tests of UHPC specimens with different cover depths and bond tests of rebar using flexural members. In this experimental study, specimens are fabricated with the lap-splice length as test variable in relation with the calculation of the lap-splice length for 180- MPa UHPC. Moreover, specimens are also fabricated with the cover depth as test variable to evaluate the effect of the cover depth on the UHPC flexural members. The load-displacement curves are analyzed for each of these test variables to compute the lap-splice length proposed in the K-UHPC structural design guideline and to evaluate the influence of the cover depth on the flexural members. As a result, the stability of the structural behavior can be significantly enhanced by increasing slightly the cover depth specification of the current UHPC Structure Design Guideline from the maximum value between 1.5 times of rebar diameter and 20 mm to the maximum value between 1.5 times of rebar diameter and 25 mm. 展开更多
关键词 Bond Behavior ultra high performance concrete (UHPC) Lap-Splice Length Cover Depth Flexural Bond Test Full-Out Test
下载PDF
Comparative Study on Test Performance of Two Kinds of High Modulus Asphalt Concrete for the Steel Bridge Deck
10
作者 Jianlin Yuan Junjie Yang 《Journal of Architectural Research and Development》 2021年第2期21-24,共4页
Along with the popularization and application of the steel bridge in China,due to the high modulus of asphalt concrete with good waterproof,anti-fatigue,anti-aging and good performance,asphalt concrete with high modul... Along with the popularization and application of the steel bridge in China,due to the high modulus of asphalt concrete with good waterproof,anti-fatigue,anti-aging and good performance,asphalt concrete with high modulus was widely used in steel bridge deck pavement,the test and comparative study of high modulus asphalt concrete were carried out based on two types of common high modulus asphalt concrete which include the casting type asphalt concrete and epoxy resin modified asphalt concrete,aims to further explore the performance features of the steel bridge deck with high modulus asphalt concrete,and provide help on the application of this asphalt concrete on the steel bridge deck. 展开更多
关键词 steel bridge deck high modulus Asphalt concrete Test performance
下载PDF
RESEARCH ON THE HIGH PERFORMANCE COMPOSITE ROAD CONCRETE
11
作者 胡曙光 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2000年第4期1-6,共6页
Ordinary concrete presents short service life when used for building and repairing high-grade road with heavy traffic due to its large brittleness, poor bending flexibility and serious shrinkage on drying. In this pap... Ordinary concrete presents short service life when used for building and repairing high-grade road with heavy traffic due to its large brittleness, poor bending flexibility and serious shrinkage on drying. In this paper, a new kind of high performance concrete has been designed by means of combination of organic, inorganic material as well as metal material. The research and application have shown that this new concrete can significantly counteract the deficiency of ordinary concrete and give excellent mechanical properties and pavement performances. The application of this new kind of concrete is of great social and economic significance. 展开更多
关键词 high performance concrete COMPOSITE POLYMER steel fiber road material
下载PDF
Seismic Behavior of Steel Reinforced Ultra High Strength Concrete Column and Reinforced Concrete Beam Connection
12
作者 闫长旺 贾金青 张菊 《Transactions of Tianjin University》 EI CAS 2010年第4期309-316,共8页
To investigate the seismic behavior of connections composed of steel reinforced ultra high strength concrete (SRUHSC) column and reinforced concrete (RC) beam, six interior strong-column-weak-beam connection specimens... To investigate the seismic behavior of connections composed of steel reinforced ultra high strength concrete (SRUHSC) column and reinforced concrete (RC) beam, six interior strong-column-weak-beam connection specimens were tested subjected to reversal cyclic load. Effects of applied axial load ratio and volumetric stirrup ratio on ductility, energy dissipation capacity, strength degradation and rigidity degradation were discussed. It was found that all connection specimens failed in bending in a ductile manner with a beam plastic hinge. The ductility and energy dissipation capacity increased with the decrease of applied axial load ratio or increase of volumetric stirrup ratio. The displacement ductility coefficient and equivalent damping coefficient lay between those of steel reinforced ordinary concrete connection and those of reinforced concrete connection. The applied axial load ratio and volumetric stirrup ratio had less influence on the strength degradation and more influence on the stiffness degradation. The stiffness degraded sharply with the decrease of volumetric stirrup ratio or increase of applied axial load ratio. The experimental results indicate that SRUHSC column and RC beam connection exhibited better seismic performance and can provide reference for engineering application. 展开更多
关键词 seismic performance steel reinforced ultra high strength concrete CONNECTION applied axial load ratio volumetric stirrup ratio
下载PDF
A Study on the Flexural Performance of UHPC Precast Deck-Joint Interface by the Exposure of Steel Fiber 被引量:1
13
作者 Kilje Jung Sung Yong Park +2 位作者 Sung Tae Kim Byung-Suk Kim Keunhee Cho 《Engineering(科研)》 2014年第13期1000-1006,共7页
As a solution against the serviceability problem caused by the cracks occurring at the UHPC precast deck-joint interface, this study proposes a method exposing the steel fiber at the interface and evaluates the corres... As a solution against the serviceability problem caused by the cracks occurring at the UHPC precast deck-joint interface, this study proposes a method exposing the steel fiber at the interface and evaluates the corresponding flexural performance of the lap spliced construction joint. After having slowed down the strength development of the concrete placed in the joint of the precast deck by means of a curing retardant, the concrete at the interface is crushed so as to expose the steel fibers and the change in the flexural performance is observed experimentally according to the exposure of the steel fibers. The results show that, even if the ultimate strength and stiffness of the UHPC precast deck including the joint are mostly determined by the arrangement details of the rebar lap splice, the exposure of the steel fibers can secure stable ductile behavior and reduce the width of the cracks generated at the precast deck-joint interface under service load. 展开更多
关键词 ultra-high performance concrete PRECAST DECK System steel Fiber EXPOSURE Lap-Spliced Connection 4-Point Bending Test
下载PDF
A comparative study for the impact performance of shaped charge JET on UHPC targets 被引量:6
14
作者 Hao Wu Feng Hu Qin Fang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2019年第4期506-518,共13页
With the development of two-stage munitions(a precursor shaped charge(SC)and a following kinetic energy projectile)to attack the hard concrete targets,as well as the increasing applications of ultra-high performance c... With the development of two-stage munitions(a precursor shaped charge(SC)and a following kinetic energy projectile)to attack the hard concrete targets,as well as the increasing applications of ultra-high performance concrete(UHPC)in both civil and military protective structures,a comparative study on the impact performance of SC formed jet on UHPC target is performed experimentally and numerically at present.Firstly,a series of jet penetration/perforation test on the UHPC,45# steel and UHPC/45# steel composite targets are conducted.By assessing the penetration depth and borehole(crater and tunnel)diameter,the influences of target material and configuration as well as the standoff distance of SC on the impact performance of jet are experimentally discussed.Then,by adopting the 2 D multi-material Arbitrary Lagrange-Euler(ALE)algorithm,Fluid-Structure Interaction(FSI)method and erosion algorithm implemented in the finite element code LS-DYNA,the formation and impact performance of jet in the present test are well reproduced.Finally,based on the validated numerical algorithms,constitutive models and the corresponding parameters,the influences of target material(UHPC,NSC and 45# steel),standoff distance,target configuration(stacked and spaced)and weight efficiency on the impact performance of jet are further discussed.The derived conclusions could provide helpful references for evaluating the ballistic performance of jet and designing the protective structures. 展开更多
关键词 Shaped charge JET ultra-high performance concrete PENETRATION PERFORATION Numerical simulation
下载PDF
Connection between Concrete Layers with Different Strengths 被引量:1
15
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2015年第7期365-372,共8页
As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the met... As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the methods for its composition with a slab using 30 MPa-concrete and the corresponding interfacial behavior. Prior to the loading test, the design formula of the Eurocode for the shear resistance developed in concrete-to-concrete interface is examined for the interface between concrete layers of different strengths. The effect of the surface roughness on the shear resistance is examined using this formula and finite element analysis to verify the applicability of the formula. Based upon the results, loading test is conducted on girder specimens to evaluate the actual behavior with respect to the interfacial surface condition. The test results reveal that the specimen with rough interface could not develop perfectly composite behavior and experienced adhesive failure. In case of simultaneous action of flexure and shear, it appears that conservative design should be applied without consideration of the interfacial condition when determining the arrangement of shear reinforcement. 展开更多
关键词 Shear Resistance Interface BETWEEN concrete LAYERS Surface ROUGHNESS steel-concrete Hybrid GIRDER ultra high performance concrete (UHPC)
下载PDF
Analysis of Compressive Strength Development of Ultra-high Performance Concrete
16
作者 HAN Fangyu LIU Jianzhong +2 位作者 ZHANG Qianqian LIU Jiaping SHI Liang 《Journal of the Chinese Ceramic Society》 2016年第3期145-152,共8页
A numerical procedure was presented for evaluating the compressive strength development of ultra-high performance concrete(UHPC) with cement-silica fume-slag binder.This numerical procedure started with initial packin... A numerical procedure was presented for evaluating the compressive strength development of ultra-high performance concrete(UHPC) with cement-silica fume-slag binder.This numerical procedure started with initial packing behavior of designed UHPC using a random sequential packing method.Furthermore,synergistic effect of combined mineral admixtures was addressed with respect to hydration heat.Accordingly,hydration degree of cement and reaction degrees of mineral admixtures were determined based on a blended cement hydration model.Finally,a compressive strength evolution model was proposed and the evolution of compressive strength of three mixes with different binder recipes was compared.The results showed that the both initial packing behavior of UHPC mixes and synergistic effect of mineral admixtures are critical for predicting the properties of UHPC.A remarkable void fraction of 0.2042 was observed for UHPC mix designed by optimization algorithms under random packing.Furthermore,a negative synergistic effect of the combination of silica fume and slag was obtained with regarding to compressive strength.In addition,for a given mineral admixture replacement of 20%,the formulation of mineral admixture should be carefully tailored where the UHPC incorporating 5%silica fume and 15%slag shows the highest compressive strength. 展开更多
关键词 ultra-high performance concrete initial packing behavior hydration model compressive strength
原文传递
拼接成型UHPC免拆模板钢筋混凝土柱的抗震性能 被引量:2
17
作者 王朋 尤学辉 +3 位作者 黄杰 史庆轩 陶毅 王秋维 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2024年第1期103-116,共14页
为研究超高性能混凝土(UHPC)免拆模板钢筋混凝土(URC)柱的抗震性能,选取UHPC免拆模板拼接方式和表面处理方式为试验设计参数,制作并完成了9个URC柱和1个钢筋混凝土(RC)柱的拟静力加载试验。模板拼接方式为螺栓加角钢连接、螺栓连接和环... 为研究超高性能混凝土(UHPC)免拆模板钢筋混凝土(URC)柱的抗震性能,选取UHPC免拆模板拼接方式和表面处理方式为试验设计参数,制作并完成了9个URC柱和1个钢筋混凝土(RC)柱的拟静力加载试验。模板拼接方式为螺栓加角钢连接、螺栓连接和环氧树脂砂浆连接;表面处理方式为光面处理、气泡膜印花处理和设肋处理,通过拟静力试验研究了模板拼接方式及表面处理方式对该类柱抗震性能的影响。此外,基于平截面假定,提出了URC柱的正截面偏压承载力计算式。结果表明:峰值荷载前,UHPC模板与核心混凝土黏结面无明显破坏,URC柱表现出良好的整体性,尤其是采用螺栓加角钢连接的URC柱,即使加载至极限位移时,也没有发生界面黏结失效破坏;与普通RC柱相比,URC柱的承载力提高了6.4%~43.3%,延性提高了11.4%~48.7%,耗能能力提高了27.7%~85.3%;三种连接方式中,采用螺栓加角钢连接的URC柱承载力最高,连接最可靠。最后,基于平截面假定提出的公式计算值与试验值吻合较好,可为工程应用提供参考。 展开更多
关键词 超高性能混凝土 免拆模板 钢筋混凝土柱 抗震性能 承载力计算
下载PDF
高强钢管超高性能混凝土短柱轴压承载力性能试验研究 被引量:1
18
作者 陈俊 王秋湛 +3 位作者 郭鸣琴 曾琳惠 张学兵 谭鑫阳 《湘潭大学学报(自然科学版)》 CAS 2024年第2期20-34,共15页
为研究高强钢管内填超高性能混凝土(UHPC)的钢管混凝土短柱轴压性能,该文设计22根高强钢管UHPC短柱进行轴压试验,从破坏模式、荷载-纵向应变关系对试件的轴压性能进行对比分析,旨在通过径厚比、混凝土强度、截面类型等变化来探究高强钢... 为研究高强钢管内填超高性能混凝土(UHPC)的钢管混凝土短柱轴压性能,该文设计22根高强钢管UHPC短柱进行轴压试验,从破坏模式、荷载-纵向应变关系对试件的轴压性能进行对比分析,旨在通过径厚比、混凝土强度、截面类型等变化来探究高强钢管UHPC短柱的实际承载力性能差异.试验结果表明:高强钢管UHPC短柱的轴压性能受径厚比、混凝土强度影响较大;试件承载力随钢管壁厚增加而增加,但相同钢管直径和不同钢管直径增幅呈现不同规律.该文从延性、核心混凝土强度提高程度两个角度进行分析并提出高强钢管混凝土试件的相关参数设计建议.最后,将高强钢管UHPC短柱的轴压试验承载力结果与国内外规范GB 50936—2014、AIJ计算承载力结果进行对比,并基于极限平衡理论推导出高强圆钢管UHPC试件的轴压承载力计算公式,同时结合该文试验数据对其进行验证,证明了公式的准确性. 展开更多
关键词 高强钢管 超高性能混凝土 钢管混凝土短柱 极限承载力 试验研究
下载PDF
海砂超高性能混凝土试验 被引量:2
19
作者 韦建刚 陈荣 +2 位作者 黄伟 卞学海 麻秀星 《重庆大学学报》 CAS CSCD 北大核心 2024年第2期14-21,共8页
采用未淡化的海砂制备超高性能混凝土(UHPC)和普通混凝土,研究了不同氯离子含量的海砂对UHPC抗压强度、孔结构、快速氯离子渗透性以及内置钢筋耐久性的影响,并与普通混凝土进行分析比较。结果表明,海砂中的氯离子含量对UHPC抗压强度并... 采用未淡化的海砂制备超高性能混凝土(UHPC)和普通混凝土,研究了不同氯离子含量的海砂对UHPC抗压强度、孔结构、快速氯离子渗透性以及内置钢筋耐久性的影响,并与普通混凝土进行分析比较。结果表明,海砂中的氯离子含量对UHPC抗压强度并不会产生较大的消极影响;海砂UHPC的临界孔半径约为2 nm,与海砂普通混凝土不同,孔隙率随海砂中氯含量的增加而增加;即使海砂氯离子含量高达0.636%,海砂UHPC的氯离子渗透性仍可忽略不计;海砂UHPC中钢筋在28 d后处于钝化状态并趋于稳定。 展开更多
关键词 海砂 超高性能混凝土 抗压强度 孔结构 耐久性
下载PDF
预应力UHPC槽形节段与整体式混凝土板组合梁受剪性能 被引量:2
20
作者 陈宝春 陈逸聪 +1 位作者 周家亮 刘永健 《建筑科学与工程学报》 CAS 北大核心 2024年第3期54-64,共11页
将预制的UHPC槽形节段通过干缝连接和预应力张拉形成槽形梁,再与整体现浇的混凝土板组合成的组合梁,称为预应力UHPC槽形节段与整体式混凝土板组合梁(PUCS-MCS组合梁)。它是一种能充分发挥不同材料的性能、施工方便且整体性能好的新型桥... 将预制的UHPC槽形节段通过干缝连接和预应力张拉形成槽形梁,再与整体现浇的混凝土板组合成的组合梁,称为预应力UHPC槽形节段与整体式混凝土板组合梁(PUCS-MCS组合梁)。它是一种能充分发挥不同材料的性能、施工方便且整体性能好的新型桥梁结构。为探究其抗剪性能,开展了9根模型梁的试验。分析了接缝数、接缝处剪力键数、剪跨比、UHPC钢纤维体积率、配箍率和纵筋率等参数对试件变形、破坏模式、抗剪承载力的影响;基于试验研究结果,提出了PUCS-MCS组合梁抗剪承载力计算方法。结果表明:PUCS-MCS组合梁均为剪压破坏,所有梁在开裂前的荷载-挠度曲线差异不大,在开裂后刚度不断下降;PUCS-MCS组合梁的抗剪承载力随接缝处剪力键数、UHPC钢纤维掺量、配箍率和纵筋率的增大而增大,随干接缝数量增加和剪跨比的增大而减小,其中影响最显著的是干接缝和剪力键,影响最小的是钢纤维掺量和配箍率,因此PUCS-MCS组合梁可不配箍筋,并可采用较低钢纤维掺量的UHPC。 展开更多
关键词 超高性能混凝土 预应力槽形节段梁 整体式混凝土板 组合梁 受剪性能
下载PDF
上一页 1 2 102 下一页 到第
使用帮助 返回顶部