期刊文献+
共找到4,168篇文章
< 1 2 209 >
每页显示 20 50 100
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
1
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry 被引量:4
2
作者 SHAN Xiao Mei SHEN Deng Hui +2 位作者 WANG Bing Shuang LU Bei Bei HUANG Fa Yuan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第6期471-474,共4页
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ... To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. 展开更多
关键词 UPLC BPA Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and ultra performance liquid Chromatography-tandem mass spectrometry mass
下载PDF
Uncertainty Evaluation of Determination of Microcystin MC-LR in Environmental Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
3
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第6期54-57,共4页
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first... To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2). 展开更多
关键词 Uncertainty SOLID phase extraction ultra performance liquid CHROMATOGRAPHY TANDEM mass spectrometry MICROCYSTIN MC-LR China
下载PDF
Determination of Steroid Hormone Residues in Fish Tissues Using Gel Permeation Chromatography and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:3
4
作者 LI Peipei YAN Zhongyong +3 位作者 SUN Xiumei CHEN Si CHEN Yin ZHANG Xiaojun 《Journal of Ocean University of China》 SCIE CAS CSCD 2018年第5期1171-1177,共7页
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s... A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues. 展开更多
关键词 荷尔蒙 类固醇 脚踏车 层析 纸巾 液体 浸透 胶化
下载PDF
Chemical Components of Achyranthes bidentata Leaves by Ultra High Performance Liquid Chromatography-Mass Spectrometry 被引量:1
5
作者 Haiyang DONG Jinshuo MA Fulin YAN 《Medicinal Plant》 CAS 2019年第4期16-19,共4页
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c... [Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A. 展开更多
关键词 Achyranthes bidentata LEAVES ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) Chemical components Inokosterone
下载PDF
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
6
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 ultra-High performance liquid Chromatography/Orbitrap High Resolution mass spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Rapid Determination of Three Kinds of Microcystins in Environmental Water Samples by Disk SPE-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
7
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第5期62-64,68,共4页
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established.... A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples. 展开更多
关键词 Disk SOLID-PHASE extraction COLUMN ultra performance liquid chromatography-tandem mass spectrometry Environmental water sample MICROCYSTINS Lake Chao China
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
8
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
Lysophosphatidylcholine Biomarkers of Lung Cancer Detected by Ultra-performance Liquid Chromatography Coupled with Quadrupole Time-of-flight Mass Spectrometry
9
作者 DONG Jun CAI Xiao-ming +4 位作者 ZOU Li-juan CHEN Cheng XUE Xing-ya ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第5期750-755,共6页
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a... Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies. 展开更多
关键词 METABONOMICS Sample preparation ultra-performance liquid chromatography coupled with quadrupoletime-of-flight mass spectrometry(UPLC/Q-TOF MS) Lung cancer Biomarker
下载PDF
A Validated Liquid Chromatography-Mass Spectrometry Method for the Detection and Quantification of Oxidative Metabolites of 2,2',4,4'-Tetrabromodiphenyl Ether in Rat Hepatic Microsomes 被引量:1
10
作者 Sarah Catherine Moffatt Patrick Robert Edwards +1 位作者 András Szeitz Stelvio Mario Bandiera 《American Journal of Analytical Chemistry》 2011年第3期352-362,共11页
In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodipheny... In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) metabolism by rat hepatic microsomes. BDE-47 is a brominated flame retardant that was widely used in a variety of consumer products and has subsequently been identified as a ubiquitous environmental contaminant. Hydroxy-bromodiphenyl ethers (OH-BDEs) were isolated from rat hepatic microsomes by liquid-liquid extraction. Chromatographic separation was achieved by UPLC on a C18 column with gradient elution using a mobile phase consisting of methanol and water, each containing 0.1% formic acid, at a flow rate of 0.2 mL/min. Detection and quantification were performed using a mass spectrometer in single ion recording mode with negative electrospray ionization. The UPLC/MS method was validated for linearity, limit of quantification (LOQ), accuracy, precision and recovery. The weighted calibration curves (1/X2) were linear over a concentration range of 5 - 250 nM with LOQ values between 5 nM and 50 nM for the individual OH-BDEs. Intra- and inter- day accuracy (%DEV) and precision (%RSD) values ranged from –11.7% to 9.5% and 5.9% to 16.5%, respectively. Recovery values of 70% to 90% were obtained for all OH-BDEs. The validated method allowed us to successfully analyze metabolite formation following incubation of BDE-47 with hepatic microsomes prepared from phenobarbital-treated rats. Results demonstrate that the UPLC/MS method has sufficient sensitivity and reproducibility to fully characterize the in vitro metabolism of BDE-47 and possibly other PBDEs. 展开更多
关键词 BDE-47 HEPATIC Metabolism Polybrominated DIPHENYL ETHERS RAT HEPATIC MICROSOMES ultra performance liquid Chromatography-mass spectrometry
下载PDF
Study of Serum Metabonomics and Formula-Pattern Correspondence in Coronary Heart Disease Patients Diagnosed as Phlegm or Blood Stasis Pattern Based on Ultra Performance Liquid Chromatography Mass Spectrometry 被引量:11
11
作者 LU Xiao-yan XU Hao +1 位作者 ZHAO Tie LI Geng 《Chinese Journal of Integrative Medicine》 SCIE CAS CSCD 2018年第12期905-911,共7页
Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. M... Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. Methods: A total of 102 stable CHD patients were enrolled and divided into phlegm group (P group, n=52) and blood stasis group (BS group, n=50) according to pattern identification. Gualou Xiebai Banxia Decoction (瓜萎薤白半夏汤, GXBD) and Xuefu Zhuyu Decoction (血府逐瘀汤, XZD) were used as drug interventions. Relevant indicators of metabonomics were observed by ultra performance liquid chromatography mass spectrometry (UPLC-MS) and pattern recognition. Results: Levels of amino acids and phosphatidylethanolamine (PE) in the CHD group were much higher than those in healthy control group, while the levels of unsaturated fatty acids, sphingosine, Lyso, phosphatidylcholine (PC) were significantly lower (P〈0.01). Most of the differential metabolites between the CHD and the healthy groups were also common metabolites of phlegm and blood stasis. 7(Z), 10(Z)- hexadecadienoic acid and DPA were decreased in the P group and increased in the BS group. According to the quantity of retraced metabolites, improvement in metabonomics by formula-pattern correspondence was superior to that without correspondence in the BS group. Based on the varieties of metabolites, GXBD could improve the levels of docosapentaenoic acid (DPA), sphingomyelin (SM) (d34:1), and L-Lactic acid and XZD could ameliorate the levels of sphingosine and Vit E in the P group, in the BS group, GXBD could improve vitamin E level and XZD could make improvements in the levels of octadecanoic acid, phosphoglycerol, and SM (d34:1). Conclusions: Phlegm and blood stasis in CHD patients present specific differential metabolites, and share common metabolites. Remarkable differences have been displayed in pathological properties and severity of phlegm and blood stasis. Patients with phlegm are more likely to have lipid metabolism disorders. However, in patients with blood stasis, problems mainly lie in glucose, protein and fat metabolism and the injury of vascular cell membrane is relatively severe. The metabolic disorder is more complicated in blood stasis pattem than that in phlegm pattem. Compared with non-correspondence, improvement of differential metabolites is more comprehensive and targeted in formulapattern correspondence with a better effect. 展开更多
关键词 ultra performance liquid chromatography mass spectrometry METABONOMICS phlegm/stasis pattern in coronary heart disease disease-pattern combination formula-pattern correspondence
原文传递
Detecting N-nitrosamines in water treatment plants and distribution systems in China using ultra-performance liquid chromatography-tandem mass spectrometry 被引量:11
12
作者 Chengkun WANG Xiaojian ZHANG +1 位作者 Jun WANG Chao CHEN 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2012年第6期770-777,共8页
N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem... N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem mass spectrometry method with solid phase extraction sample preparation was developed to study the occurrence of N-nitrosamines in several water treatment plants and distribution systems in China. Isotope labeled N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was selected as the internal standard for quantification. The solid phase extraction procedures including pH, enrichment process and MS/MS parameters including capillary voltage, cone gas flow, cone voltage, collision energy were optimized to give average recoveries of 26% to 112% for nine N- nitrosamine species. The instrument detection limits were estimated to range from 0.5 to 5μg.L-1 for the nine N- nitrosamine species. NDMA and several other N-nitrosa- mines were found at fairly high concentrations in several water treatment plants and distribution systems. NDMA was found in all locations, and the highest concentrations in cities B, G, T, and W were 3.0, 35.7, 21.3, and 19.7 ng. L 1, respectively. A wide range of N-nitrosamines concentrations and species were observed in different locations. Higher concentrations of N-nitrosamines were detected in distribution systems that were further away from the treatment plants, suggesting that the contact time between the residual disinfectant and natural organic matter may play an important role in the formation of these compounds. 展开更多
关键词 N-NITROSAMINES water treatment plant distri-bution system ultra-performance liquid chromatography-tandem mass spectrometry
原文传递
Simultaneous Determination of Six Compounds in Rat Plasma by Ultra-Performance Liquid Chromatography with Tandem Mass Spectrometry: Application in the Pharmacokinetic Study of Qing Gan-Shu Yu-Fang 被引量:1
13
作者 Hai Jiang A-Jiao Houa +10 位作者 Yan-Yan Zhang Wen-Jing Man Liu Yang Yong-Hai Meng Xin-Yue Guo Song Wang Jia-Xu Zhang Bing-You Yang Qiu-Hong Wang Kelvin Chan Hai-Xue Kuang 《World Journal of Traditional Chinese Medicine》 2019年第4期250-259,共10页
A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,s... A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,saikosaponin A,and saikosaponin D in rat plasma was developed and validated using butyl p-hydroxybenzoate as an internal standard.One-step direct protein precipitation with acetonitrile was used to extract the compounds from the rat plasma samples.Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column(100 mm×2.1 mm,1.7μm)at a flow rate of 0.4 m L/min,using gradient mode containing 0.1%formic acid in water and acetonitrile were used as the Mobile phase A and B.Electrospray ionization in negative ion mode and multiple reaction monitoring were used to identify and quantify active components.Calibration curves showed good linearity(R^2>0.9908)over a wide concentration range for all compounds.The intra-and interday precision(relative standard deviation)ranged 2.4%–7.0%and 2.6%–8.0%,respectively.The accuracy(relative error)was from-13.0%to 13.2%at all quality control levels.The recovery ranged from 81.1%to 92.5%.The validated method was successfully applied to pharmacokinetic study in rats after oral administration of Qing Gan-Shu Yu-Fang.The results show that one can draw a conclusion that these six active ingredients can be quickly absorbed and play a pharmacodynamic role rapidly in vivo. 展开更多
关键词 PHARMACOKINETICS traditional Chinese medicine prescriptions ultra-performance liquid chromatography with tandem mass spectrometry
原文传递
Rapid Determination of Tetrodotoxin in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
14
作者 CHEN Weizhu ZHANG Yiping +3 位作者 SUN Jipeng XIE Quanling HONG Zhuan YI Ruizao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2018年第6期905-911,共7页
A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tande... A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples. 展开更多
关键词 Tetrodotoxin(TTX) 11-DeoxyTTX ultra performance liquid chromatography(UPLC)coupled with tandem mass spectrometry(MS/MS) PLASMA Protein precipitation
原文传递
Analysis of hydroxylated polybrominated diphenyl ethers in plant samples using ultra performance liquid chromatography-mass spectrometry
15
作者 WANG Sen WU Tong +3 位作者 HUANG HongLin PING Hua LU AnXiang ZHANG ShuZhen 《Science China Chemistry》 SCIE EI CAS 2011年第11期1782-1788,共7页
A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in n... A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in negative mode. Plant samples were extracted and cleaned up through florisil column, resolved on a 100 mm C18 column with linear gradient elution and detected by mass spectrometry in multiple reaction monitoring (MRM) mode. The method provided good recoveries rang- ing from 68.2% to 94.6%, relative standard deviation (RSD) in the range of 3.2% - 9.1%, and limits of quantification (LOQ) defined as the signal-to-noise ratio of 10 of 0.3-2.1 ng/g. It allowed a fast separation and sensitive quantification of the isomers and homologues of seven OH-PBDE congeners 2′-OH-BDE-3, 3′-OH-BDE-7, 4′-OH-BDE-17, 3′-OH-BDE-28, 3-OH-BDE-47, 5-OH-BDE-47 and 6-OH-BDE-47. The method was successfully applied to identify and quantify the formation of hydroxylat- ed metabolites in alfalfa exposed to BDE-209. Five OH-PBDEs were detected in plant tissues, and more congeners were found in roots than in shoots. To our knowledge, this work represents the first attempt to validate UPLC-MS/MS method to quantify OH-PBDEs in plant samples without derivatization. 展开更多
关键词 超高效液相色谱 植物样品 质谱法 多溴联苯醚 羟基 PBDES 线性梯度洗脱 相对标准偏差
原文传递
An Automatic Solid Phase Extraction and Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry for Determination of Seven Microcystins at Ultra-Trace Levels in Surface Water
16
作者 SHEN Fei XU Yanjuan +1 位作者 WANG Ye CHEN Jing 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2019年第1期30-36,共7页
A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatogr... A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS). The automated solid-phase extraction system was used to extract microcystins(MCs) from water samples. UPLC-MS/MS was used to determine MCs concentrations in just 5 min. Method detection limits were from 0.3 to 0.9 ng/L, microcystin recoveries ranged from 83.8% to 114%, and the relative standard deviation(RSD) varied from 5.6% to 12.5%. This analytical approach was found to be simple, highly sensitive, accurate, which required little manual operation. Additionally, to validate this analytical method, A-SPE+UPLC-MS/MS was applied to characterize the concentration of MCs in Taihu Lake, Wuxi, China. 展开更多
关键词 MICROCYSTINS AUTOMATIC SOLID-PHASE extraction ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS)
原文传递
GLOBAL ANALYSIS OF THE METABOLITES OF CURCUMIN IN RATS BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY COUPLED WITH QUADRUPOLE TIME OF-FLIGHT TANDEM MASS SPECTROMETRY
17
作者 Feng Qiu Tianyi Qiu +2 位作者 Yang Yu Liqin Ding Xinchi Feng 《World Journal of Traditional Chinese Medicine》 2015年第4期100-101,共2页
Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism... Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism in vivoand the predominant metabolic pathways are reduction and conjugation.In order to comprehensively study the metabolism and enrich the metabolic profile of cxurcumin in vivo,we carried out this research.A systematic method with highly sensitive UPLC-Q/TOF-MS was established to analyze different biological samples of rats after 展开更多
关键词 GLOBAL ANALYSIS OF THE METABOLITES OF CURCUMIN IN RATS BY ultra performance liquid CHROMATOGRAPHY COUPLED WITH QUADRUPOLE TIME OF-FLIGHT TANDEM mass spectrometry
原文传递
超高效液相色谱-串联质谱法同时测定蔬菜中氯酸盐和高氯酸盐 被引量:1
18
作者 邹淼 刘顺鑫 +1 位作者 冯静 韩晓鸥 《化学分析计量》 CAS 2024年第2期62-66,共5页
建立超高效液相色谱-串联质谱法测定蔬菜中氯酸盐和高氯酸盐。样品以少量水稀释分散后,加入乙腈提取,经PRIME HLB小柱净化,用Waters Torus DEA色谱柱(100 mm×2.1 mm,1.7μm)分离,以同位素内标法定量。在各自的线性范围内,氯酸盐、... 建立超高效液相色谱-串联质谱法测定蔬菜中氯酸盐和高氯酸盐。样品以少量水稀释分散后,加入乙腈提取,经PRIME HLB小柱净化,用Waters Torus DEA色谱柱(100 mm×2.1 mm,1.7μm)分离,以同位素内标法定量。在各自的线性范围内,氯酸盐、高氯酸盐的质量浓度与氯酸盐、高氯酸盐和相应同位素内标物的色谱峰面积比线性关系良好,相关系数均大于0.999。氯酸盐的检出限为3.0μg/kg,定量限为10μg/kg,高氯酸盐的检出限为1.5μg/kg,定量限为4.5μg/kg,平均回收率为88.9%~97.1%,相对标准偏差为2.9%~7.4%(n=6)。该方法简便、快速,适用于蔬菜中氯酸盐和高氯酸盐的同时快速检测。 展开更多
关键词 超高效液相色谱-串联质谱 氯酸盐 高氯酸盐 蔬菜
下载PDF
改进的QuEChERS结合超高效液相色谱-串联质谱法检测饲料中的环匹阿尼酸
19
作者 彭茂民 喻小兵 +6 位作者 陈琳 熊青松 刘丽 郑丹 夏虹 余琼卫 彭西甜 《色谱》 CAS CSCD 北大核心 2024年第5期445-451,共7页
采用改进的QuEChERS前处理方法结合超高效液相色谱-串联质谱(UPLC-MS/MS)分离检测,建立了饲料中真菌毒素环匹阿尼酸(CPA)的快速分析新方法。详细优化了UPLC-MS/MS分离检测条件和影响CPA回收率的QuEChERS条件,优化后的分析方法如下:1.0 ... 采用改进的QuEChERS前处理方法结合超高效液相色谱-串联质谱(UPLC-MS/MS)分离检测,建立了饲料中真菌毒素环匹阿尼酸(CPA)的快速分析新方法。详细优化了UPLC-MS/MS分离检测条件和影响CPA回收率的QuEChERS条件,优化后的分析方法如下:1.0 g饲料加入2 mL水和4 mL 0.5%乙酸乙腈溶液进行提取,再加入提取盐包(0.4 g氯化钠和1.6 g无水硫酸镁),离心分层后,取1 mL乙腈提取液,加入150 mg无水硫酸镁和50 mg C_(18)吸附净化,上清液进行UPLC-MS/MS分离检测;采用Waters HSS T3柱(100 mm×2.1 mm, 1.8μm),以含0.5%甲酸的2 mmol/L乙酸铵水溶液和乙腈作为流动相,梯度洗脱,电喷雾正离子模式下以多反应监测(MRM)扫描模式定量。CPA在2~200 ng/mL的范围内具有良好的线性,相关系数良好(r=0.999 5),方法的检出限和定量限分别为0.6和2μg/kg,饲料中CPA在10、100、500μg/kg 3个加标水平下的回收率为70.1%~78.5%,日内RSD为4.1%~5.8%,日间RSD为6.1%~7.2%。将本方法应用于实际饲料样品中CPA的分析,取得了很好的效果。本研究将改进的QuEChERS方法应用于饲料中CPA的提取净化,为饲料中CPA的风险监测、评估和限量标准制定提供了一种有效的检测技术。 展开更多
关键词 QUECHERS 超高效液相色谱-串联质谱 环匹阿尼酸 饲料
下载PDF
超高效液相色谱-串联质谱法测定水体和底泥中的阿维菌素和伊维菌素
20
作者 万译文 杨霄 +4 位作者 谢仲桂 索纹纹 陈湘艺 肖维 李小玲 《湖南师范大学自然科学学报》 CAS 北大核心 2024年第2期136-142,共7页
为建立超高效液相色谱-串联质谱法(UHPLC-MS/MS)同时测定水产养殖环境(水体及底泥)中阿维菌素和伊维菌素的检测方法。先采用HLB固相萃取柱富集和净化水样,采用PSA和C18吸附剂净化底泥样品;样品中的目标物采用Phenomenex Kinetex C18色... 为建立超高效液相色谱-串联质谱法(UHPLC-MS/MS)同时测定水产养殖环境(水体及底泥)中阿维菌素和伊维菌素的检测方法。先采用HLB固相萃取柱富集和净化水样,采用PSA和C18吸附剂净化底泥样品;样品中的目标物采用Phenomenex Kinetex C18色谱柱分离,以5 mmol/L乙酸铵水溶液和乙腈作为流动相进行梯度洗脱,在电喷雾离子源(ESI)、正离子扫描和多反应监测(MRM)模式下进行测定,外标法定量。在最优实验条件下,阿维菌素和伊维菌素在7.5 min内完成色谱分离分析,目标物在1~100μg·L^(-1)范围内线性关系良好,相关系数均大于0.995。空白水样在0.05,0.50,2.5和5.0μg·L^(-1)共4个添加水平下的回收率为71.6%~88.2%,相对标准偏差(RSD,n=6)在1.51%~8.81%,方法检出限(LOD)为0.02μg·L^(-1),方法定量限(LOQ)为0.05μg·L^(-1);空白底泥在1.0,10.0,50.0和100.0 ng·g^(-1)共4个添加水平下的回收率为75.3%~96.4%,RSD值(n=6)为3.45%~8.99%,LOD值为0.3 ng·g^(-1),LOQ值为1.0 ng·g^(-1)。该方法灵敏度高,重现性好,操作快速简便,适用于水产养殖环境(水体和底泥)中阿维菌素和伊维菌素的分析检测。 展开更多
关键词 超高效液相色谱-串联质谱 阿维菌素 伊维菌素 底泥 水产养殖环境
下载PDF
上一页 1 2 209 下一页 到第
使用帮助 返回顶部