To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ...To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.展开更多
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a...Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.展开更多
A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tande...A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples.展开更多
A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatogr...A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS). The automated solid-phase extraction system was used to extract microcystins(MCs) from water samples. UPLC-MS/MS was used to determine MCs concentrations in just 5 min. Method detection limits were from 0.3 to 0.9 ng/L, microcystin recoveries ranged from 83.8% to 114%, and the relative standard deviation(RSD) varied from 5.6% to 12.5%. This analytical approach was found to be simple, highly sensitive, accurate, which required little manual operation. Additionally, to validate this analytical method, A-SPE+UPLC-MS/MS was applied to characterize the concentration of MCs in Taihu Lake, Wuxi, China.展开更多
基金supported by the Preventive medicine and public health research project of Anhui,China(No.2011Y0103)the Natural Science Foundation of Anhui,China(No.11040606M216)
文摘To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.
基金Supported by the National Natural Science Foundation of China(No.30801513)the Knowledge Innovation Program of Chinese Academy of Sciences(No.KSCX2-YW-R-170)
文摘Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.
基金Supported by the National Key Research and Development Program of China(No.2016YFF0201104)the Construction of Public Service Platform for Research and Test of Marine Pilot Technology of China(No.Bhsfs009)the Project of Xiamen Southern oceanographic Center,China(No.16PFW008SF15).
文摘A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples.
基金Supported by the Environmental Monitoring and Research Foundation of Jiangsu Province(1621)the Taihu Lake Pollution Prevention and Control Project of Jiangsu Province(TH2016301)Postgraduate Research and Practice Innovation Program of Jiangsu Province in 2016(KYLX16_0813)
文摘A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS). The automated solid-phase extraction system was used to extract microcystins(MCs) from water samples. UPLC-MS/MS was used to determine MCs concentrations in just 5 min. Method detection limits were from 0.3 to 0.9 ng/L, microcystin recoveries ranged from 83.8% to 114%, and the relative standard deviation(RSD) varied from 5.6% to 12.5%. This analytical approach was found to be simple, highly sensitive, accurate, which required little manual operation. Additionally, to validate this analytical method, A-SPE+UPLC-MS/MS was applied to characterize the concentration of MCs in Taihu Lake, Wuxi, China.