Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investiga...Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO.展开更多
The low frequency oscillation characteristics of East China Power Grid after commissioning of the first ultra-high voltage alternating current(UHVAC)project-the Huai-Hu UHVAC project are studied.Several low frequency ...The low frequency oscillation characteristics of East China Power Grid after commissioning of the first ultra-high voltage alternating current(UHVAC)project-the Huai-Hu UHVAC project are studied.Several low frequency oscillation cases occurred in East China Power Grid in the past few years are reviewed and summarized.Based on the analysis of the different typical operation modes,the main low frequency oscillation modes in East China Power Grid in the early stages of development of ultra-high voltage(UHV)are summarized,and the impacts of the significant power grid maintenance on low frequency oscillation characteristics are analyzed.Besides,the oscillation mode of UHV generators to East China Power Grid is researched,and the importance of the power system stabilizator(PSS)is emphasized.Furthermore,the comparative analysis between the time domain and the frequency domain is carried out,and the influences of the governing system on low frequency oscillation characteristics are revealed.Finally,both the focus and the direction of low frequency oscillation research are presented.展开更多
With the increase of dc based renewable energy generation and dc loads,the medium voltage dc(MVDC)distribution network is becoming a promising option for more efficient system integration.In particular,large-capacity ...With the increase of dc based renewable energy generation and dc loads,the medium voltage dc(MVDC)distribution network is becoming a promising option for more efficient system integration.In particular,large-capacity photovoltaic(PV)-based power generation is growing rapidly,and a corresponding power conversion system is critical to integrate these large PV systems into MVDC power grid.Different from traditional ac grid-connected converters,the converter system for dc grid interfaced PV system requires large-capacity dc conversion over a wide range of ultra-high voltage step-up ratios.This is an important issue,yet received limited research so far.In this paper,a thorough study of dc-dc conversion system for a medium-voltage dc grid-connected PV system is conducted.The required structural features for such a conversion system are first discussed.Based on these features,the conversion system is classified into four categories by series-parallel connection scheme of power modules.Then two existing conversion system configurations as well as a proposed solution are compared in terms of input/output performance,conversion efficiency,modulation method,control complexity,power density,reliability,and hardware cost.In-depth analysis is carried out to select the most suitable conversion systems in various application scenarios.展开更多
基金supported in part by National Natural Science Foundation of China(No.51277106)in part by the National Basic Research Program of China(973 Program)(No.2011CB209405)
文摘Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO.
基金Project supported by Funds for Innovative Research Groups of China (51021005), National Basic Research Program of China (973 Program) (2009CB724504), National Natural Science Foundation of China(50707036).
文摘The low frequency oscillation characteristics of East China Power Grid after commissioning of the first ultra-high voltage alternating current(UHVAC)project-the Huai-Hu UHVAC project are studied.Several low frequency oscillation cases occurred in East China Power Grid in the past few years are reviewed and summarized.Based on the analysis of the different typical operation modes,the main low frequency oscillation modes in East China Power Grid in the early stages of development of ultra-high voltage(UHV)are summarized,and the impacts of the significant power grid maintenance on low frequency oscillation characteristics are analyzed.Besides,the oscillation mode of UHV generators to East China Power Grid is researched,and the importance of the power system stabilizator(PSS)is emphasized.Furthermore,the comparative analysis between the time domain and the frequency domain is carried out,and the influences of the governing system on low frequency oscillation characteristics are revealed.Finally,both the focus and the direction of low frequency oscillation research are presented.
基金Supported by the National Natural Science Foundation of China(51811540405,52007096)National Key R&D Program of China(2016YFB0900205).
文摘With the increase of dc based renewable energy generation and dc loads,the medium voltage dc(MVDC)distribution network is becoming a promising option for more efficient system integration.In particular,large-capacity photovoltaic(PV)-based power generation is growing rapidly,and a corresponding power conversion system is critical to integrate these large PV systems into MVDC power grid.Different from traditional ac grid-connected converters,the converter system for dc grid interfaced PV system requires large-capacity dc conversion over a wide range of ultra-high voltage step-up ratios.This is an important issue,yet received limited research so far.In this paper,a thorough study of dc-dc conversion system for a medium-voltage dc grid-connected PV system is conducted.The required structural features for such a conversion system are first discussed.Based on these features,the conversion system is classified into four categories by series-parallel connection scheme of power modules.Then two existing conversion system configurations as well as a proposed solution are compared in terms of input/output performance,conversion efficiency,modulation method,control complexity,power density,reliability,and hardware cost.In-depth analysis is carried out to select the most suitable conversion systems in various application scenarios.
文摘为保障低压配电线路检修作业安全,有必要研究低压配线在停运检修状态下的感应电压和电流。采用EMTP建模仿真,分别计算了上海地区4个超/特高压交、直流输电工程线路下方平行架设的380 V低压配线上的感应电压、电流,对影响感应的因素进行了分析,并设计研发了低压配电线路感应电压消除装置。仿真结果表明,超/特高压交、直流线路在其下方停运的380 V配线上产生较大的感应电压和电流,感应电压最高可达30~70 k V。试验结果表明,低压配线感应电压消除装置在线路停运时将其两端接地,能有效消除配电线路上的感应电压。