The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged ...The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future.展开更多
Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have prove...Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have proven their operational reliability and functional assurance.In the past,cables were used in distribution networks in urban areas for the most part with the exception of direct current submarine cables.New developments of high voltage XLPE cables make it possible to use this technology for EHV level applications in transmission networks.Within this paper,mixed network configurations,consisting of overhead lines and high voltage cables,are investigated.An exemplary EHV transmission line with a total length of about 100 km,which is quite typical for Central Europe,has been studied.Several different line combinations are discussed with varied rates between overhead line sections and cable sections length in practice.The length of the cable sections are ranging from several kilometers up to lengths of 100 km.In this paper the work focuses on the transient behavior of combined 400 kV overhead and cable lines during switching processes and lightning impacts.A number of calculations were carried out to get an overview of the transient stress in numerous network nodes along the transmission system.Numerical programs like ATP/EMTP have been used for these simulations.Peak values and wave shapes of the transient voltage stress have been evaluated,based on different systems and within possible combinations.In respect of the insulation coordination and transient stress at network nodes,the voltage-time trends are also analyzed.The combination of high voltage overhead and cable transmission systems,especially such with lengths of more than about 50 km,are making tightened and extended demands to the network design,to the operational management and of course to the network protection also.As an output of this investigations,the results might influence the strategy in running this new type of combined transmission systems.展开更多
Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investiga...Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO.展开更多
A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/s...A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/sec Ethemet communication, can be transmitted from the shore to the seafloor through an umbilical armored cable. A subsea junction box is fixed at a cable terminal, enabling the extension of up to nine connections. The box consists of three main pressure vessels that perform power conversion, power distribution, and real-time communication functions. A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments. A power distribution system and an Ethemet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station, respectively. Specific validations of all sections were qualified in a laboratory environment prior to the sea trial. The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test. The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations.展开更多
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s...Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.展开更多
Potassium-based dual ion batteries(KDIBs)have attracted significant attention owing to high working voltage,high safety,low processing cost,and environmental friendliness.Nevertheless,one great challenge for practical...Potassium-based dual ion batteries(KDIBs)have attracted significant attention owing to high working voltage,high safety,low processing cost,and environmental friendliness.Nevertheless,one great challenge for practical KDIBs is to develop suitable anode materials with high specific capacity.Herein,we report an architecture of hierarchically porous antimony nanoparticles/carbon nanofibers(HPSb CNFs)as flexible,free-standing anode for high-performance KDIBs.The HPSb CNFs with hierarchically porous structure,and high-content nitrogen doping,not only offer sufficient free space to tolerate the repetitive volume expansion of Sb nanoparticles during long-term cycling,but also greatly facilitate the transport of electrons and ions within electrode,ensuring high material utilization ratio.Thus,the KDIBs,constituted by HPSb CNFs-700(calcined at 700°C)anode and graphite cathode,exhibited a high reversible capacity of 440 m Ah g^(-1)with high discharge medium voltage of 4.5 V at a specific current of 200 m A g^(-1)(the highest capacity for all KDIBs normalized by the mass of the anode),and excellent cyclic life.Outstanding electrochemical reversibility of the KDIBs was further demonstrated by ex situ XRD,ex situ Raman spectrum,and HRTEM.These results suggest the as-designed HPSb CNFs-700 with highcapacity and long-term cycling stability is a promising anode material for high-performance KDIBs.展开更多
Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This pap...Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This paper aims to study the scheme composition and power supply distance(PSD)of the scheme.Design/methodology/approach–Based on the structure of parallel traction network(referred to as“cable traction network(CTN)”),the power supply modes(PSMs)are divided into cableþdirect PSM and cableþautotransformer(AT)PSM(including Japanese mode,French mode and new mode).Taking cableþJapanese AT PSM as an example,the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed.On the basis of establishing the equivalent circuit model and the chain circuit model of CTN,taking the train working voltage as the constraint condition,and based on the power flow calculation of multiple train loads,the calculation formula and process for determining the PSD of CTN are given.The impedance and PSD of CTN under the cableþAT PSM are simulated and analyzed,and a certain line is taken as an example to compare the scheme design.Findings–Results show that the equivalent impedance of CTN under the cableþAT PSM is smaller,and the PSD is about 2.5 times of that under the AT PSM,which can effectively increase the PSD and the flexibility of external power supply location.Originality/value–The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme.展开更多
缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于...缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于缆式焊丝独特的绞合结构引起电弧旋转,进而导致出现熔滴受力不均的现象,熔滴过渡方向与焊丝轴线存在夹角,在熔滴冲击力的作用下导致焊缝截面出现侧偏现象,随着电流的增加,电弧对熔滴的拘束增强,熔滴过渡方向逐渐趋于轴线,因而焊缝截面侧偏的趋势随着电流增加而减小.展开更多
基金Project supported by National Natural Science Foundation of China(51277131), State Key Laboratory Electrical Insulation and Power Equipment, State Key Laboratory Power System (SKLD 11KZ06).
文摘The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future.
文摘Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have proven their operational reliability and functional assurance.In the past,cables were used in distribution networks in urban areas for the most part with the exception of direct current submarine cables.New developments of high voltage XLPE cables make it possible to use this technology for EHV level applications in transmission networks.Within this paper,mixed network configurations,consisting of overhead lines and high voltage cables,are investigated.An exemplary EHV transmission line with a total length of about 100 km,which is quite typical for Central Europe,has been studied.Several different line combinations are discussed with varied rates between overhead line sections and cable sections length in practice.The length of the cable sections are ranging from several kilometers up to lengths of 100 km.In this paper the work focuses on the transient behavior of combined 400 kV overhead and cable lines during switching processes and lightning impacts.A number of calculations were carried out to get an overview of the transient stress in numerous network nodes along the transmission system.Numerical programs like ATP/EMTP have been used for these simulations.Peak values and wave shapes of the transient voltage stress have been evaluated,based on different systems and within possible combinations.In respect of the insulation coordination and transient stress at network nodes,the voltage-time trends are also analyzed.The combination of high voltage overhead and cable transmission systems,especially such with lengths of more than about 50 km,are making tightened and extended demands to the network design,to the operational management and of course to the network protection also.As an output of this investigations,the results might influence the strategy in running this new type of combined transmission systems.
基金supported in part by National Natural Science Foundation of China(No.51277106)in part by the National Basic Research Program of China(973 Program)(No.2011CB209405)
文摘Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO.
基金supported by the National High-Technology Research and Development Program of China(Grant No.2007AA091201-1)
文摘A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/sec Ethemet communication, can be transmitted from the shore to the seafloor through an umbilical armored cable. A subsea junction box is fixed at a cable terminal, enabling the extension of up to nine connections. The box consists of three main pressure vessels that perform power conversion, power distribution, and real-time communication functions. A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments. A power distribution system and an Ethemet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station, respectively. Specific validations of all sections were qualified in a laboratory environment prior to the sea trial. The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test. The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations.
文摘Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.
基金financially supported by the National Natural Science Foundation of China(Grant No.21673070)the Fundamental Research Funds of the Central Universities(No.531107051048)Hunan Key Laboratory of Two-Dimensional Materials(No.801200005)
文摘Potassium-based dual ion batteries(KDIBs)have attracted significant attention owing to high working voltage,high safety,low processing cost,and environmental friendliness.Nevertheless,one great challenge for practical KDIBs is to develop suitable anode materials with high specific capacity.Herein,we report an architecture of hierarchically porous antimony nanoparticles/carbon nanofibers(HPSb CNFs)as flexible,free-standing anode for high-performance KDIBs.The HPSb CNFs with hierarchically porous structure,and high-content nitrogen doping,not only offer sufficient free space to tolerate the repetitive volume expansion of Sb nanoparticles during long-term cycling,but also greatly facilitate the transport of electrons and ions within electrode,ensuring high material utilization ratio.Thus,the KDIBs,constituted by HPSb CNFs-700(calcined at 700°C)anode and graphite cathode,exhibited a high reversible capacity of 440 m Ah g^(-1)with high discharge medium voltage of 4.5 V at a specific current of 200 m A g^(-1)(the highest capacity for all KDIBs normalized by the mass of the anode),and excellent cyclic life.Outstanding electrochemical reversibility of the KDIBs was further demonstrated by ex situ XRD,ex situ Raman spectrum,and HRTEM.These results suggest the as-designed HPSb CNFs-700 with highcapacity and long-term cycling stability is a promising anode material for high-performance KDIBs.
基金funded by Youth Science Foundation Fund Project of National Natural Science Foundation of China(51607148)Science and Technology R&D Program of China State Railway Group Co.,Ltd.(SY2020G001)Project of Sichuan Science and Technology Program(2021YJ0028)。
文摘Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This paper aims to study the scheme composition and power supply distance(PSD)of the scheme.Design/methodology/approach–Based on the structure of parallel traction network(referred to as“cable traction network(CTN)”),the power supply modes(PSMs)are divided into cableþdirect PSM and cableþautotransformer(AT)PSM(including Japanese mode,French mode and new mode).Taking cableþJapanese AT PSM as an example,the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed.On the basis of establishing the equivalent circuit model and the chain circuit model of CTN,taking the train working voltage as the constraint condition,and based on the power flow calculation of multiple train loads,the calculation formula and process for determining the PSD of CTN are given.The impedance and PSD of CTN under the cableþAT PSM are simulated and analyzed,and a certain line is taken as an example to compare the scheme design.Findings–Results show that the equivalent impedance of CTN under the cableþAT PSM is smaller,and the PSD is about 2.5 times of that under the AT PSM,which can effectively increase the PSD and the flexibility of external power supply location.Originality/value–The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme.
文摘缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于缆式焊丝独特的绞合结构引起电弧旋转,进而导致出现熔滴受力不均的现象,熔滴过渡方向与焊丝轴线存在夹角,在熔滴冲击力的作用下导致焊缝截面出现侧偏现象,随着电流的增加,电弧对熔滴的拘束增强,熔滴过渡方向逐渐趋于轴线,因而焊缝截面侧偏的趋势随着电流增加而减小.