The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three...The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three different undulator lines in a bunch-by-bunch mode.The kicker field width must be less than the time interval between bunches.A lumpedinductance kicker prototype was developed using a vacuum chamber with a single-turn coil.The full magnetic field strength was 0.005 T.This paper presents the requirements,design considerations,design parameters,magnetic field calculations,and measurements of the kicker magnets.The relevant experimental results are also presented.The pulse width of the magnetic field was approximately 600 ns,and the maximum operation repetition rate was 1 MHz.The developed kicker satisfies the requirements for the SHINE project.Finally,numerous recommendations for the future optimization of kicker magnets are provided.展开更多
The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically...The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically thin plasma spectra by setting an appropriate exposure time.In this work,a novel SAF-LIBS technique with high repetition rate acousto-optic gating is developed,in which an acousto-optic modulator is used as the shutter to diffract the optically thin fluorescence,and a high repetition rate laser is used to produce quasi-continuous plasmas to enhance the integral spectral intensity,so that the CCD spectrometer can replace an intensified CCD(ICCD)and echelle spectrometer in SAF-LIBS.Experimental results show that the average absolute prediction error of aluminum is reduced to 0.18%,which is equivalent to that of traditional SAF-LIBS.This technique not only effectively shields continuous background radiation and broadened spectral lines in optically thick plasma,but also has advantages of miniaturization,low cost,convenience and reliability.展开更多
Satellite laser ranging (SLR) is one of the major space geodetic instruments, which has various applications in earth science. In this paper, we introduce several issues regarding the key technology implementation o...Satellite laser ranging (SLR) is one of the major space geodetic instruments, which has various applications in earth science. In this paper, we introduce several issues regarding the key technology implementation of high-repetition-rate SLR system. Compared with traditional technology, using kHz and 8ps pulse width laser component, the data quantity and quality of high-repetition-rate satellite laser ranging (SLR) can be significantly improved. The characteristics of high-repetition-rate laser ranging and the key technologies are presented, including the event timer with the precision of picosecond, the generation of range gate signal, and so on. All of them are based on the Field Programmable Gate Arrays (FPGA) and tested on China mobile SLR system-TROS1000. Finally, the observations of satellite Beacon-C are given.展开更多
A compact high power diode-pumped passively mode-locked Nd:YVO_4 laser with high repetition rate is realized.Using an Nd:YVO_4 crystal and a semiconductor saturable absorber mirror(SESAM) in the oscillator, the picose...A compact high power diode-pumped passively mode-locked Nd:YVO_4 laser with high repetition rate is realized.Using an Nd:YVO_4 crystal and a semiconductor saturable absorber mirror(SESAM) in the oscillator, the picosecond pulse output with an average power of 1.38 W, a repetition rate of 3.24 GHz, and a pulse duration of 11.4 ps is achieved. After one stage of amplification, the final output power reaches 11.34 W, corresponding to a total optical-to-optical efficiency of about 32%. The root mean square(RMS) value of power fluctuation is demonstrated to be less than 0.6% in 24 hours,showing a superior stability with the compact configuration.展开更多
We demonstrate a diode pumped Yb:LuVO4 laser that can be passively Q-switched by a Cr^(4+):YAG saturable absorber having an initial transmission as high as 99.3%.A maximum pulsed output power of 2.35 W is generat...We demonstrate a diode pumped Yb:LuVO4 laser that can be passively Q-switched by a Cr^(4+):YAG saturable absorber having an initial transmission as high as 99.3%.A maximum pulsed output power of 2.35 W is generated at a repetition rate of 285.7 kHz,approaching or very near the intrinsic upper limit imposed by the recovery time of the Cr^(4+):YAG saturable absorber,and the resulting pulse energy,duration and peak power are,respectively,8.2μJ,39.2ns and 0.209kW.展开更多
We report on a compact, stable, all-fiberized narrow-linewidth(0.045 nm) pulsed laser source emitting laser beam with a wavelength of 266 nm, and tunable pulse width and repetition rate. The system is based on all-fib...We report on a compact, stable, all-fiberized narrow-linewidth(0.045 nm) pulsed laser source emitting laser beam with a wavelength of 266 nm, and tunable pulse width and repetition rate. The system is based on all-fiberized nanosecond amplifier architecture, which consists of Yb-doped fiber preamplifiers and a super-large-mode-area Yb-doped fiber power amplifier. The fiber amplifier with a core of 50 μm is used to raise the threshold of the stimulated Brillouin scattering(SBS) effect and to obtain high output power and single pulse energy. Using lithium triborate(LBO) crystal and betabarium borate(BBO) crystal for realizing the second-harmonic generation(SHG) and fourth-harmonic generation(FHG),we achieve 17 μJ(1.73 W) and 0.66 μJ(66 mW), respectively, at wavelengths of 532 nm and 266 nm and a repetition rate of 100 kHz with pulse width of 4 ns. This source has great potential applications in fluorescence research and solar-blind ultraviolet optical communication.展开更多
We propose and demonstrate a Q-switched erbium-doped fiber laser (EDFL) using an erbium-doped zirconia-alumina silica glass-based fiber (Zr-EDF) as a saturable absorber. As a 16-cm-long Zr-EDF is incorporated into...We propose and demonstrate a Q-switched erbium-doped fiber laser (EDFL) using an erbium-doped zirconia-alumina silica glass-based fiber (Zr-EDF) as a saturable absorber. As a 16-cm-long Zr-EDF is incorporated into a ring EDFL cavity, a stable Q-switching pulse train operating at 1565?nm wavelength is successfully obtained. The repetition rate is tunable from 33.97?kHz to 71.23?kHz by increasing the pump power from the threshold of 26?mW to the maximum of 74?mW. The highest pulse energy of 26.67?nJ is obtained at the maximum pump power.展开更多
This paper presents a Kerr-lens mode-locked Ti:sapphire laser at the repetition rate of 525 MHz, stable laser pulse as short as 10 fs with average output power of 480 mW is obtained. By injecting the pulse into photo...This paper presents a Kerr-lens mode-locked Ti:sapphire laser at the repetition rate of 525 MHz, stable laser pulse as short as 10 fs with average output power of 480 mW is obtained. By injecting the pulse into photonics crystal fibre, octave-spanning spectrum covered from 500 to 1050 nm is generated, carrier-envelope phase frequency with signal-to- noise ratio of 31dB is measured, which paves the way for the generation of a compact frequency comb.展开更多
High repetition rate laser-ablation spark-induced breakdown spectroscopy(HRR LA-SIBS) was first used to analyze trace elements in copper alloy samples. The 1064 nm output of an acoustooptically Q-switched Nd:YAG laser...High repetition rate laser-ablation spark-induced breakdown spectroscopy(HRR LA-SIBS) was first used to analyze trace elements in copper alloy samples. The 1064 nm output of an acoustooptically Q-switched Nd:YAG laser operated at a pulse repetition rate of 1 kHz was utilized to ablate copper alloy and to form original plasma, spark-discharge was applied to further breakdown the ablated samples and enhance the emission of the laser-induced plasma. A compact multichannel fiber spectrometer was used to analyze the plasma emission under nongated operation mode. Under the assistance of high repetition rate spark discharge, the plasma emission was able to be improved significantly. The determined limits of the detection of lead and aluminum were 15.5 ppm and 1.9 ppm by HRR LA-SIBS, respectively, which were 11 and 6 folds better than that determined by HRR LIBS under the same laser-ablation condition. This work demonstrates the feasibility of using fiber spectrometer to analyze plasma emission under non-gated operation mode and the possibility of building a portable HRR LA-SIBS system for rapid elemental analysis of copper alloys and other solid samples.展开更多
The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-indu...The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-induced spectral filtering effect, the dual-wavelength lasing operation can be achieved. In order to enhance the cross coupling effect between the two lasing beams for domain wall pulse formation, a 215-m HNLF is incorporated into the laser cavity. Experimentally, it is found that the dual-wavelength domain wall pulse with a repetition rate of 77.67 kHz could be efficiently obtained through simply rotating the polarization controller (PC). At a maximum pump power of 322 mW, the 655-nJ single pulse energy in cavity is obtained. The proposed configuration provides a simpler and more efficient way to generate high energy pulse with a low repetition rate.展开更多
We demonstrated a monolithic, compact, diode-pumped gain-switched Nd:YVO4 laser at 1.064 μm wavelength with controllable repetition rate of 1 Hz to 25 kHz. Stable gain-switched pulse train with maximum repetition rat...We demonstrated a monolithic, compact, diode-pumped gain-switched Nd:YVO4 laser at 1.064 μm wavelength with controllable repetition rate of 1 Hz to 25 kHz. Stable gain-switched pulse train with maximum repetition rate of 25 kHz and pulse width of 16 ns was obtained.展开更多
Satellite laser ranging(SLR)with higher repetition rate is the recent trend for its various advantages.Laser backscatter(coincidence between recently transmitted pulses and received pulses near the detector)is found t...Satellite laser ranging(SLR)with higher repetition rate is the recent trend for its various advantages.Laser backscatter(coincidence between recently transmitted pulses and received pulses near the detector)is found to be a constraint for the repetition rates higher than 20 kHz,due to,overlapping with photons returning from a satellite with the present constellation of most of the SLR systems.Such an overlap occurs at every 75 km satellite distance change at 2 kHz repetition rate,and remains for about 7.5 km;for a 20 kHz system however,it will occur after every 7.5 km and remains for 7.5 km,resulting in constant backscatter overlap e leaving no chance to avoid it.The resulting noise is 5 times more than before causing a serious problem in detection and lowers the signal to noise ratio of the overall SLR system.However,decreasing energy per shot at higher repetition rates e assuming a constant power laser e the resulting backscatter may decrease fractionally.展开更多
We demonstrate an all-fiberized narrow-linewidth nanosecond amplifier with high peak power,tunable pulse width,and repetition rate.A fiber-coupled narrow-linewidth laser diode operating at 1064.1 nm is employed as the...We demonstrate an all-fiberized narrow-linewidth nanosecond amplifier with high peak power,tunable pulse width,and repetition rate.A fiber-coupled narrow-linewidth laser diode operating at 1064.1 nm is employed as the seed source,which is gain-switched to generate nanosecond pulses with tunable pulse widths of 1-200 ns and tunable repetition rates of10 Hz-100 kHz.By utilizing a very-large-mode-area Yb-doped fiber with a core diameter of 50 μm in the power amplifier,thresholds of the stimulated Brillouin scattering at different pulse widths and repetition rates are increased.The maximum average power reaches 30.8 W at the pulse width of 4 ns and a repetition rate of 100 kHz,corresponding to an optical-tooptical conversion efficiency of ~55.2%.Pulse energy and peak power are calculated to be 0.2 mJ and 50 kW,respectively,which are limited by stimulated Brillouin scattering.The 3-dB spectral linewidth remains around 0.05 nm during the power scaling process.The stimulated Brillouin scattering limited output powers at different pulse widths and repetition rates are investigated.Peak power of 47.5 kW(0.19 mJ) is obtained for the 4 ns pulses at a repetition rate of 50 kHz,which is nearly the same as that of 4 ns pulses at 100 kHz.When the pulse width of the seed source is increased to 8 ns,peak powers/pulse energies are decreased to 19.6 kW/0.11 mJ and 13.3 kW/0.08 mJ at repetition rates of 50 kHz and 100 kHz,respectively.展开更多
Simultaneous metabolic and oxygen imaging is promising to follow up therapy response,dis-ease development and to determine prognostic factors.FLIM of metabolic coenzymes is now widely accepted to be the most reliable ...Simultaneous metabolic and oxygen imaging is promising to follow up therapy response,dis-ease development and to determine prognostic factors.FLIM of metabolic coenzymes is now widely accepted to be the most reliable method to determine cellular bioenergetics.Also,oxygen consumption has to be taken into account to understand treatment responses.The phosphorescence lifetimne of oxygen sensors is able to indicate local oxygen changes.For phosphorescence lifetime imaging(PLIM)dyes based on ruthenium(I)coordination com-plexes are useful,in detaill TLD1433 which possesses a variety of different triplet states,enables complex photochemistry and redox reactions.PLIM is usally reached by two photon exci-tation of the drug with a femtosecond(fs)pulsed Ti:Sapphire laser working at 80 MHz repe-tition rate and(time-correlated single photon counting)(TCSPC)detection electronics.The interesting question was whether it is possible to follow up PLIM 1using faster repetition rates.Faster repetition rates could be advantageous for the induction of specific photochemical reactions because of similar light doses used normally in standard CW light treatments.For this,a default 2p-FLIM-PLIM system was expanded by adding a second fs pulsed laser("helixx")which provides 50 fs pulses at a repetition rate of 250 MHz,more than 2.3 w average power and tunable from 720 nm to 920 nm.The laser beam was coupled into the AOM instead of the default 80 MHz laser.We demonstrated siuccessful applications of the 250 MHz laser for PLIM which correlates well with measurements done by excitation with the conventional 80MHx laser source.展开更多
A multi-shot target assembly and automatic alignment procedure for laser–plasma proton acceleration at high repetition rate are introduced.The assembly is based on a multi-target rotating wheel capable of hosting mor...A multi-shot target assembly and automatic alignment procedure for laser–plasma proton acceleration at high repetition rate are introduced.The assembly is based on a multi-target rotating wheel capable of hosting more than 5000 targets,mounted on a 3D motorized stage to allow rapid replenishment and alignment of the target material between laser irradiations.The automatic alignment procedure consists of a detailed mapping of the impact positions at the target surface prior to the irradiation that ensures stable operation of the target,which alongside the purpose-built design of the target wheel,enables operation at rates up to 10 Hz.Stable and continuous laser-driven proton acceleration at 10 Hz is demonstrated,with observed cut-off energy stability about 15%.展开更多
The stimulated Brillouin scattering phase conjugation mirror (SBS-PCM) based on liquid media is widely used in high-power laser systems due to its robust thermal load capacity, high energy conversion efficiency and im...The stimulated Brillouin scattering phase conjugation mirror (SBS-PCM) based on liquid media is widely used in high-power laser systems due to its robust thermal load capacity, high energy conversion efficiency and improved beam quality. Nevertheless, with an increase in the pump repetition rate, thermally-induced blooming and optical breakdown can emerge, leading to distortions in the Stokes beam. In this study, we delved into the thermal effects in liquid SBS-PCMs employing hydrodynamic analysis, establishing a relationship between beam profile distortion and the thermal convection field. We calculated the temperature and convection velocity distribution based on the pump light parameters and recorded the corresponding beam profiles. The intensities of the beam profiles were modulated in alignment with the convection directions, reaching a velocity peak of 2.85 mm/s at a pump pulse repetition rate of 250 Hz. The residual sum of squares (RSS) was employed to quantify the extent of beam profile distortion relative to a Gaussian distribution. The RSS escalated to 7.8, in contrast to 0.7 of the pump light at a pump pulse repetition rate of 500 Hz. By suppressing thermal convection using a high-viscosity medium, we effectively mitigated beam distortion. The RSS was reduced to 0.7 at a pump pulse repetition rate of 500 Hz, coinciding with a twentyfold increase in viscosity, thereby enhancing the beam quality. By integrating hydrodynamic analysis, we elucidated and mitigated distortion with targeted solutions. Our research offers an interdisciplinary perspective on studying thermal effects and contributes to the application of SBS-PCMs in high-repetition-rate laser systems by unveiling the mechanism of photothermal effects.展开更多
An efficient single-carrier symbol synchronization method is proposed in this paper,which can work under a very low oversampling rate.This method is based on the frequency aliasing squared timing recovery assisted by ...An efficient single-carrier symbol synchronization method is proposed in this paper,which can work under a very low oversampling rate.This method is based on the frequency aliasing squared timing recovery assisted by pilot symbols and time domain filter.With frequency aliasing squared timing recovery with pilots,it is accessible to estimate timing error under oversampling rate less than 2.The time domain filter simultaneously performs matched-filtering and arbitrary interpolation.Because of pilot assisting,timing error estimation can be free from alias and self noise,so our method has good performance.Compared with traditional time-domain methods requiring oversampling rate above 2,this method can be adapted to any rational oversampling rate including less than 2.Moreover,compared with symbol synchronization in frequency domain which can operate under low oversampling rate,our method saves the complicated operation of conversion between time domain and frequency domain.By low oversampling rate and resource saving filter,this method is suitable for ultra-high-speed communication systems under resource-restricted hardware.The paper carries on the simulation and realization under 64QAM system.The simulation result shows that the loss is very low(less than 0.5 dB),and the real-time implementation on field programmable gate array(FPGA)also works fine.展开更多
Objective:To investigate the clinical effect of ultra-low frequency repetitive transcranial magnetic stimulation on dysphagia in elderly patients with acute cerebral infarction and its impact on quality of life.Method...Objective:To investigate the clinical effect of ultra-low frequency repetitive transcranial magnetic stimulation on dysphagia in elderly patients with acute cerebral infarction and its impact on quality of life.Methods:60 elderly patients with dysphagia caused by acute cerebral infarction were randomly divided into rTMS group and control group,30 cases in each group.Both groups received routine drug therapy and swallowing function training.rTMS group was additionally treated by ultra-low frequency(10mHZ)repetitive transcranial magnetic stimulation for 14 days.The changes of NIHSS score andADL score and NSE serum level and Wa Tian drinking water experiment and Fujishima Ichiro dysphagia scale score and SWAL-QOL score and SF-36 score were observed between the two groups before and after treatment.The clinical effect was evaluated by Wa Tian drinking water experiment.Results:After treatment,The clinical effective rate in rTMS group was significantly higher compared with that in the control group(P<0.05),NIHSS score and serum NSE level were significantly lower compared with the control group(P<0.05),ADL score and Fujishima Ichiro dysphagia score and SWAL-QOL score and SF-36 scores were significantly higher compared with the control group(P<0.05).After treatment,SF-36 total score(or SWAL-QOL Score)was negatively correlated with NSE serum level and NIHSS score,which was positively correlated with ADL score and Fujishima Ichiro dysphagia scale score score.Conclusion:Ultra-low frequency rTMS therapy can reduce NSE level,effectively improve dysphagia in elderly patients with acute cerebral infarction and significantly improve the elderly patients'life quality.展开更多
The relationship between the hardware requirement of digital down converters(DDCs)in ultra-low symbol rate receivers and the word length is studied.Through analyzing the impact of word length selection to the system...The relationship between the hardware requirement of digital down converters(DDCs)in ultra-low symbol rate receivers and the word length is studied.Through analyzing the impact of word length selection to the system performance,a modified scheme is presented to decline the resource consumption without too much degradation on the signal to noise ratio(SNR).Theoretical analysis and numerical results demonstrate that compared to the traditional design,the proposed scheme could save dozens of memory resources.The scheme also includes some selectable parameters to achieve desired performance in various circumstances.Different from previous work in DDCs that concentrates mostly on the structure design,this paper considers special applications such as ultra-low symbol rate receivers.展开更多
Introduction: Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for brain stimulation. Repetitive TMS (rTMS) over the medial Prefrontal Cortex (mPFC), Broadman Area 10 (BA10) may stimulate transynapt...Introduction: Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for brain stimulation. Repetitive TMS (rTMS) over the medial Prefrontal Cortex (mPFC), Broadman Area 10 (BA10) may stimulate transynaptically perigenual Anterior Cingulate Cortex (pACC, BA 33), insula, amigdala, hypothalamus and connected branches of the Autonomic Nervous System (ANS) involved in stressorevoked cardiovascular reactivity. Stressors are associated with an increase in sympathetic cardiac control, a decrease in parasympathetic control, or both, and, consequently, an increase in systolic/stroke volume, total vascular impedance/resistance and heart rate, a decrease of baroreflex sensitivity, i.e., an increase in blood pressure/arterial tension. Objectives and Aims: The present work aims, using TMS and accordingly to Gianaros modeling, based on functional neuroimaging studies and previous neuroanatomical data from animal models, to probe the connectivity of brain systems involved in stressor-evoked cardiovascular reactivity and to explore TMS potential as a tool for detection and stratification of individual differences concerning this reactivity and hemorreological risk factors correlated with the development of Coronary Heart Disease (CHD). Methods: Both subjects, a 52 years old male and a 40 years old female with previous increased Low Frequency (LF)/High Frequency (HF) Heart Rate Variability (HRV) ratios (respectively, 4.209/3.028) without decompensated cardiorespiratory symptoms, gave informed consent, and ethico-legal issues have been observed. Electroencephalographic (EEG) monitoring has been performed for safety purposes. Immediately after administration, over the mPFC, of 15 pulses of rTMS, during 60 second, with an inductive electrical current, at the stimulating coil, of 85.9 Ampère per μsecond and 66 Ampère per μsecond, respectively, for male and female subjects (a “figure-of-eight” coil and magnetic stimulator MagLite, Dantec/Medtronic, have been used), HRV spectrum analysis (cStress software) has been performed (during 5 minutes, in supine position). Results: In both subjects, LF power, HF power and LF/HF ratio results, before and after rTMS administration, pointed towards sympathetic attenuation and parasympathetic augmentation (respectively, in male/female subject: decreased LF power—65.1 nu/69.3 nu, before rTMS;56.1 nu/41.6 nu, after rTMS;increased HF power—15.5 nu/22.9 nu, before rTMS;30.9 nu/45.5 nu, after rTMS). Conclusions: In this preliminary investigation, the existence of a link between “mind” and heart’s function has been put in evidence, through a reversible “virtual” lesion, of brain systems involved in cardiovascular control, caused by TMS. Repetitive TMS over mPFC decreased brain function involved in stressorevoked cardiovascular reactivity, suggesting the importance of TMS in the management of stress-related cardiovascular disorders.展开更多
基金This work was supported by the Shanghai Municipal Science and Technology Major Project(No.2017SHZDZX02)the National Natural Science Foundation of China(No.12005282)+1 种基金the Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.2021283)the Shanghai Pilot Program for Basic Research—Chinese Academy of Science,Shanghai Branch(JCYJSHFY-2021-010).
文摘The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three different undulator lines in a bunch-by-bunch mode.The kicker field width must be less than the time interval between bunches.A lumpedinductance kicker prototype was developed using a vacuum chamber with a single-turn coil.The full magnetic field strength was 0.005 T.This paper presents the requirements,design considerations,design parameters,magnetic field calculations,and measurements of the kicker magnets.The relevant experimental results are also presented.The pulse width of the magnetic field was approximately 600 ns,and the maximum operation repetition rate was 1 MHz.The developed kicker satisfies the requirements for the SHINE project.Finally,numerous recommendations for the future optimization of kicker magnets are provided.
基金National Key R&D Program of China(No.2017YFA0304203)National Energy R&D Center of Petroleum Refining Technology(RIPP,SINOPEC),Changjiang Scholars and Innovative Research Team in University of Ministry of Education of China(IRT_17R70)+3 种基金National Natural Science Foundation of China(Nos.61975103,61875108,61775125 and 11434007)Major Special Science and Technology Projects in Shanxi(No.201804D131036)111 Project(No.D18001)Fund for Shanxi’1331KSC’。
文摘The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically thin plasma spectra by setting an appropriate exposure time.In this work,a novel SAF-LIBS technique with high repetition rate acousto-optic gating is developed,in which an acousto-optic modulator is used as the shutter to diffract the optically thin fluorescence,and a high repetition rate laser is used to produce quasi-continuous plasmas to enhance the integral spectral intensity,so that the CCD spectrometer can replace an intensified CCD(ICCD)and echelle spectrometer in SAF-LIBS.Experimental results show that the average absolute prediction error of aluminum is reduced to 0.18%,which is equivalent to that of traditional SAF-LIBS.This technique not only effectively shields continuous background radiation and broadened spectral lines in optically thick plasma,but also has advantages of miniaturization,low cost,convenience and reliability.
基金supported by the National Natural Science Foundation of China(40774013)
文摘Satellite laser ranging (SLR) is one of the major space geodetic instruments, which has various applications in earth science. In this paper, we introduce several issues regarding the key technology implementation of high-repetition-rate SLR system. Compared with traditional technology, using kHz and 8ps pulse width laser component, the data quantity and quality of high-repetition-rate satellite laser ranging (SLR) can be significantly improved. The characteristics of high-repetition-rate laser ranging and the key technologies are presented, including the event timer with the precision of picosecond, the generation of range gate signal, and so on. All of them are based on the Field Programmable Gate Arrays (FPGA) and tested on China mobile SLR system-TROS1000. Finally, the observations of satellite Beacon-C are given.
基金Project supported by the Strategic Priority Research Program of Chinese Academy of Sciences(Grant No.XDB16030200)the National Natural Science Foundation of China(Grant Nos.11774410 and 61575217)+1 种基金the National Key Scientific Instruments Development Program of China(Grant No.2012YQ120047)the Key Research Program of Frontier Sciences of Chinese Academy of Sciences(Grant No.KJZD-EW-L11-03)
文摘A compact high power diode-pumped passively mode-locked Nd:YVO_4 laser with high repetition rate is realized.Using an Nd:YVO_4 crystal and a semiconductor saturable absorber mirror(SESAM) in the oscillator, the picosecond pulse output with an average power of 1.38 W, a repetition rate of 3.24 GHz, and a pulse duration of 11.4 ps is achieved. After one stage of amplification, the final output power reaches 11.34 W, corresponding to a total optical-to-optical efficiency of about 32%. The root mean square(RMS) value of power fluctuation is demonstrated to be less than 0.6% in 24 hours,showing a superior stability with the compact configuration.
基金Supported by the National Natural Science Foundation of China under Grant No 11574170
文摘We demonstrate a diode pumped Yb:LuVO4 laser that can be passively Q-switched by a Cr^(4+):YAG saturable absorber having an initial transmission as high as 99.3%.A maximum pulsed output power of 2.35 W is generated at a repetition rate of 285.7 kHz,approaching or very near the intrinsic upper limit imposed by the recovery time of the Cr^(4+):YAG saturable absorber,and the resulting pulse energy,duration and peak power are,respectively,8.2μJ,39.2ns and 0.209kW.
基金Project supported by the Key Program of Beijing Municipal Natural Science Foundation, China (Grant No. KZ201910005006)the National Nature Science Foundation of China (Grant No. 62005004)+1 种基金the Natural Science Foundation of Beijing Municipality, China (Grant No. 4204091)the National Science Foundation for Postdoctor Scientists of China (Grant No. 212423)。
文摘We report on a compact, stable, all-fiberized narrow-linewidth(0.045 nm) pulsed laser source emitting laser beam with a wavelength of 266 nm, and tunable pulse width and repetition rate. The system is based on all-fiberized nanosecond amplifier architecture, which consists of Yb-doped fiber preamplifiers and a super-large-mode-area Yb-doped fiber power amplifier. The fiber amplifier with a core of 50 μm is used to raise the threshold of the stimulated Brillouin scattering(SBS) effect and to obtain high output power and single pulse energy. Using lithium triborate(LBO) crystal and betabarium borate(BBO) crystal for realizing the second-harmonic generation(SHG) and fourth-harmonic generation(FHG),we achieve 17 μJ(1.73 W) and 0.66 μJ(66 mW), respectively, at wavelengths of 532 nm and 266 nm and a repetition rate of 100 kHz with pulse width of 4 ns. This source has great potential applications in fluorescence research and solar-blind ultraviolet optical communication.
基金Supported by the Postgraduate Research of Malaysia under Grant No PG098-2014Bthe CSIR of Government of India
文摘We propose and demonstrate a Q-switched erbium-doped fiber laser (EDFL) using an erbium-doped zirconia-alumina silica glass-based fiber (Zr-EDF) as a saturable absorber. As a 16-cm-long Zr-EDF is incorporated into a ring EDFL cavity, a stable Q-switching pulse train operating at 1565?nm wavelength is successfully obtained. The repetition rate is tunable from 33.97?kHz to 71.23?kHz by increasing the pump power from the threshold of 26?mW to the maximum of 74?mW. The highest pulse energy of 26.67?nJ is obtained at the maximum pump power.
基金supported by National Natural Science Foundation of China (Grant Nos 60490281 and 60621063)National Basic Research Program of China (Grant No 2007CB815104)
文摘This paper presents a Kerr-lens mode-locked Ti:sapphire laser at the repetition rate of 525 MHz, stable laser pulse as short as 10 fs with average output power of 480 mW is obtained. By injecting the pulse into photonics crystal fibre, octave-spanning spectrum covered from 500 to 1050 nm is generated, carrier-envelope phase frequency with signal-to- noise ratio of 31dB is measured, which paves the way for the generation of a compact frequency comb.
基金financially supported by National Basic Research Program (973 Program) of China under grant number 2012CB921900National Natural Science Foundation of China under grant numbers 11274123 and 11304100
文摘High repetition rate laser-ablation spark-induced breakdown spectroscopy(HRR LA-SIBS) was first used to analyze trace elements in copper alloy samples. The 1064 nm output of an acoustooptically Q-switched Nd:YAG laser operated at a pulse repetition rate of 1 kHz was utilized to ablate copper alloy and to form original plasma, spark-discharge was applied to further breakdown the ablated samples and enhance the emission of the laser-induced plasma. A compact multichannel fiber spectrometer was used to analyze the plasma emission under nongated operation mode. Under the assistance of high repetition rate spark discharge, the plasma emission was able to be improved significantly. The determined limits of the detection of lead and aluminum were 15.5 ppm and 1.9 ppm by HRR LA-SIBS, respectively, which were 11 and 6 folds better than that determined by HRR LIBS under the same laser-ablation condition. This work demonstrates the feasibility of using fiber spectrometer to analyze plasma emission under non-gated operation mode and the possibility of building a portable HRR LA-SIBS system for rapid elemental analysis of copper alloys and other solid samples.
基金supported by the National Natural Science Foundation of China(Grant Nos.11074078,61378036,61307058,11304101,and 61177077)the Specialized Research Fund for the Doctoral Program of Higher Education,China(Grant No.20094407110002)the Ph.D.Start-up Fund of the Natural Science Foundation of Guangdong Province,China(Grant No.S2013040016320)
文摘The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-induced spectral filtering effect, the dual-wavelength lasing operation can be achieved. In order to enhance the cross coupling effect between the two lasing beams for domain wall pulse formation, a 215-m HNLF is incorporated into the laser cavity. Experimentally, it is found that the dual-wavelength domain wall pulse with a repetition rate of 77.67 kHz could be efficiently obtained through simply rotating the polarization controller (PC). At a maximum pump power of 322 mW, the 655-nJ single pulse energy in cavity is obtained. The proposed configuration provides a simpler and more efficient way to generate high energy pulse with a low repetition rate.
文摘We demonstrated a monolithic, compact, diode-pumped gain-switched Nd:YVO4 laser at 1.064 μm wavelength with controllable repetition rate of 1 Hz to 25 kHz. Stable gain-switched pulse train with maximum repetition rate of 25 kHz and pulse width of 16 ns was obtained.
基金the Austrian Academy of Science for providing a placement and Higher education commission of Pakistan to fund this study
文摘Satellite laser ranging(SLR)with higher repetition rate is the recent trend for its various advantages.Laser backscatter(coincidence between recently transmitted pulses and received pulses near the detector)is found to be a constraint for the repetition rates higher than 20 kHz,due to,overlapping with photons returning from a satellite with the present constellation of most of the SLR systems.Such an overlap occurs at every 75 km satellite distance change at 2 kHz repetition rate,and remains for about 7.5 km;for a 20 kHz system however,it will occur after every 7.5 km and remains for 7.5 km,resulting in constant backscatter overlap e leaving no chance to avoid it.The resulting noise is 5 times more than before causing a serious problem in detection and lowers the signal to noise ratio of the overall SLR system.However,decreasing energy per shot at higher repetition rates e assuming a constant power laser e the resulting backscatter may decrease fractionally.
基金Project supported by the National Natural Science Foundation of China (Grant No. 61675009)the Beijing Natural Science Foundation Program, China,Scientific Research Key Program of Beijing Municipal Education Commission, China (Grant No. KZ201910005006)
文摘We demonstrate an all-fiberized narrow-linewidth nanosecond amplifier with high peak power,tunable pulse width,and repetition rate.A fiber-coupled narrow-linewidth laser diode operating at 1064.1 nm is employed as the seed source,which is gain-switched to generate nanosecond pulses with tunable pulse widths of 1-200 ns and tunable repetition rates of10 Hz-100 kHz.By utilizing a very-large-mode-area Yb-doped fiber with a core diameter of 50 μm in the power amplifier,thresholds of the stimulated Brillouin scattering at different pulse widths and repetition rates are increased.The maximum average power reaches 30.8 W at the pulse width of 4 ns and a repetition rate of 100 kHz,corresponding to an optical-tooptical conversion efficiency of ~55.2%.Pulse energy and peak power are calculated to be 0.2 mJ and 50 kW,respectively,which are limited by stimulated Brillouin scattering.The 3-dB spectral linewidth remains around 0.05 nm during the power scaling process.The stimulated Brillouin scattering limited output powers at different pulse widths and repetition rates are investigated.Peak power of 47.5 kW(0.19 mJ) is obtained for the 4 ns pulses at a repetition rate of 50 kHz,which is nearly the same as that of 4 ns pulses at 100 kHz.When the pulse width of the seed source is increased to 8 ns,peak powers/pulse energies are decreased to 19.6 kW/0.11 mJ and 13.3 kW/0.08 mJ at repetition rates of 50 kHz and 100 kHz,respectively.
基金supported by the Ministry of Research and Development,FKZ order:13N14508("OMOXI")by the Ministry of Economics,ZIM-Project,FKZ:ZF4322901RE6("UFEMPU").
文摘Simultaneous metabolic and oxygen imaging is promising to follow up therapy response,dis-ease development and to determine prognostic factors.FLIM of metabolic coenzymes is now widely accepted to be the most reliable method to determine cellular bioenergetics.Also,oxygen consumption has to be taken into account to understand treatment responses.The phosphorescence lifetimne of oxygen sensors is able to indicate local oxygen changes.For phosphorescence lifetime imaging(PLIM)dyes based on ruthenium(I)coordination com-plexes are useful,in detaill TLD1433 which possesses a variety of different triplet states,enables complex photochemistry and redox reactions.PLIM is usally reached by two photon exci-tation of the drug with a femtosecond(fs)pulsed Ti:Sapphire laser working at 80 MHz repe-tition rate and(time-correlated single photon counting)(TCSPC)detection electronics.The interesting question was whether it is possible to follow up PLIM 1using faster repetition rates.Faster repetition rates could be advantageous for the induction of specific photochemical reactions because of similar light doses used normally in standard CW light treatments.For this,a default 2p-FLIM-PLIM system was expanded by adding a second fs pulsed laser("helixx")which provides 50 fs pulses at a repetition rate of 250 MHz,more than 2.3 w average power and tunable from 720 nm to 920 nm.The laser beam was coupled into the AOM instead of the default 80 MHz laser.We demonstrated siuccessful applications of the 250 MHz laser for PLIM which correlates well with measurements done by excitation with the conventional 80MHx laser source.
基金This work was supportedby the Spanish Ministerio de Ciencia,Innovacion y Universidades under grants RTI2018-101578-B-C21,RTI2018-101578-B-C22,FPI predoctorals BES-2017-08917 and PRE2019-090730Unidad de Excelencia Maria de Maetzu under project MdM-2016-0692-17-2+2 种基金the Xuntade Galicia grants GRC ED431C 2017/54 and ED431F2023/21 and a grant of the program Grupos de investigacion consolidados(CIAICO/2022/008)financed by Generalitat Valenciana.Action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional(FEDER)of the Comunitat Valenciana 2014-2020(IDIFEDER/2021/002)This work was supported by‘la Caixa'Foundation(ID 100010434)(fellowship code LCF/BQ/PI20/11760027)grant RYC2021-032654-I funded by MICIU/AEI/10.13039/501100011033 and by‘European Union Next Generation EU'.
文摘A multi-shot target assembly and automatic alignment procedure for laser–plasma proton acceleration at high repetition rate are introduced.The assembly is based on a multi-target rotating wheel capable of hosting more than 5000 targets,mounted on a 3D motorized stage to allow rapid replenishment and alignment of the target material between laser irradiations.The automatic alignment procedure consists of a detailed mapping of the impact positions at the target surface prior to the irradiation that ensures stable operation of the target,which alongside the purpose-built design of the target wheel,enables operation at rates up to 10 Hz.Stable and continuous laser-driven proton acceleration at 10 Hz is demonstrated,with observed cut-off energy stability about 15%.
基金supported by the National Natural Science Foundation of China (Nos. 61927815 and 62075056)the Natural Science Foundation of Tianjin City (No. 22JCYBJC01100)+2 种基金the Natural Science Foundation of Hebei Province (No. F2023202063)the Funds for Basic Scientific Research of Hebei University of Technology (No. JBKYTD2201)support from the Shijiazhuang Overseas Talents Introduction Project (No. 20230004)
文摘The stimulated Brillouin scattering phase conjugation mirror (SBS-PCM) based on liquid media is widely used in high-power laser systems due to its robust thermal load capacity, high energy conversion efficiency and improved beam quality. Nevertheless, with an increase in the pump repetition rate, thermally-induced blooming and optical breakdown can emerge, leading to distortions in the Stokes beam. In this study, we delved into the thermal effects in liquid SBS-PCMs employing hydrodynamic analysis, establishing a relationship between beam profile distortion and the thermal convection field. We calculated the temperature and convection velocity distribution based on the pump light parameters and recorded the corresponding beam profiles. The intensities of the beam profiles were modulated in alignment with the convection directions, reaching a velocity peak of 2.85 mm/s at a pump pulse repetition rate of 250 Hz. The residual sum of squares (RSS) was employed to quantify the extent of beam profile distortion relative to a Gaussian distribution. The RSS escalated to 7.8, in contrast to 0.7 of the pump light at a pump pulse repetition rate of 500 Hz. By suppressing thermal convection using a high-viscosity medium, we effectively mitigated beam distortion. The RSS was reduced to 0.7 at a pump pulse repetition rate of 500 Hz, coinciding with a twentyfold increase in viscosity, thereby enhancing the beam quality. By integrating hydrodynamic analysis, we elucidated and mitigated distortion with targeted solutions. Our research offers an interdisciplinary perspective on studying thermal effects and contributes to the application of SBS-PCMs in high-repetition-rate laser systems by unveiling the mechanism of photothermal effects.
文摘An efficient single-carrier symbol synchronization method is proposed in this paper,which can work under a very low oversampling rate.This method is based on the frequency aliasing squared timing recovery assisted by pilot symbols and time domain filter.With frequency aliasing squared timing recovery with pilots,it is accessible to estimate timing error under oversampling rate less than 2.The time domain filter simultaneously performs matched-filtering and arbitrary interpolation.Because of pilot assisting,timing error estimation can be free from alias and self noise,so our method has good performance.Compared with traditional time-domain methods requiring oversampling rate above 2,this method can be adapted to any rational oversampling rate including less than 2.Moreover,compared with symbol synchronization in frequency domain which can operate under low oversampling rate,our method saves the complicated operation of conversion between time domain and frequency domain.By low oversampling rate and resource saving filter,this method is suitable for ultra-high-speed communication systems under resource-restricted hardware.The paper carries on the simulation and realization under 64QAM system.The simulation result shows that the loss is very low(less than 0.5 dB),and the real-time implementation on field programmable gate array(FPGA)also works fine.
基金Sichuan cadre health research project(2017-1601)Scientific research and development plan project of North Sichuan Medical(CBY13-A-QN17、CBY17-B-YB24).
文摘Objective:To investigate the clinical effect of ultra-low frequency repetitive transcranial magnetic stimulation on dysphagia in elderly patients with acute cerebral infarction and its impact on quality of life.Methods:60 elderly patients with dysphagia caused by acute cerebral infarction were randomly divided into rTMS group and control group,30 cases in each group.Both groups received routine drug therapy and swallowing function training.rTMS group was additionally treated by ultra-low frequency(10mHZ)repetitive transcranial magnetic stimulation for 14 days.The changes of NIHSS score andADL score and NSE serum level and Wa Tian drinking water experiment and Fujishima Ichiro dysphagia scale score and SWAL-QOL score and SF-36 score were observed between the two groups before and after treatment.The clinical effect was evaluated by Wa Tian drinking water experiment.Results:After treatment,The clinical effective rate in rTMS group was significantly higher compared with that in the control group(P<0.05),NIHSS score and serum NSE level were significantly lower compared with the control group(P<0.05),ADL score and Fujishima Ichiro dysphagia score and SWAL-QOL score and SF-36 scores were significantly higher compared with the control group(P<0.05).After treatment,SF-36 total score(or SWAL-QOL Score)was negatively correlated with NSE serum level and NIHSS score,which was positively correlated with ADL score and Fujishima Ichiro dysphagia scale score score.Conclusion:Ultra-low frequency rTMS therapy can reduce NSE level,effectively improve dysphagia in elderly patients with acute cerebral infarction and significantly improve the elderly patients'life quality.
基金Supported by the National Natural Science Foundation of China(60972018)
文摘The relationship between the hardware requirement of digital down converters(DDCs)in ultra-low symbol rate receivers and the word length is studied.Through analyzing the impact of word length selection to the system performance,a modified scheme is presented to decline the resource consumption without too much degradation on the signal to noise ratio(SNR).Theoretical analysis and numerical results demonstrate that compared to the traditional design,the proposed scheme could save dozens of memory resources.The scheme also includes some selectable parameters to achieve desired performance in various circumstances.Different from previous work in DDCs that concentrates mostly on the structure design,this paper considers special applications such as ultra-low symbol rate receivers.
文摘Introduction: Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for brain stimulation. Repetitive TMS (rTMS) over the medial Prefrontal Cortex (mPFC), Broadman Area 10 (BA10) may stimulate transynaptically perigenual Anterior Cingulate Cortex (pACC, BA 33), insula, amigdala, hypothalamus and connected branches of the Autonomic Nervous System (ANS) involved in stressorevoked cardiovascular reactivity. Stressors are associated with an increase in sympathetic cardiac control, a decrease in parasympathetic control, or both, and, consequently, an increase in systolic/stroke volume, total vascular impedance/resistance and heart rate, a decrease of baroreflex sensitivity, i.e., an increase in blood pressure/arterial tension. Objectives and Aims: The present work aims, using TMS and accordingly to Gianaros modeling, based on functional neuroimaging studies and previous neuroanatomical data from animal models, to probe the connectivity of brain systems involved in stressor-evoked cardiovascular reactivity and to explore TMS potential as a tool for detection and stratification of individual differences concerning this reactivity and hemorreological risk factors correlated with the development of Coronary Heart Disease (CHD). Methods: Both subjects, a 52 years old male and a 40 years old female with previous increased Low Frequency (LF)/High Frequency (HF) Heart Rate Variability (HRV) ratios (respectively, 4.209/3.028) without decompensated cardiorespiratory symptoms, gave informed consent, and ethico-legal issues have been observed. Electroencephalographic (EEG) monitoring has been performed for safety purposes. Immediately after administration, over the mPFC, of 15 pulses of rTMS, during 60 second, with an inductive electrical current, at the stimulating coil, of 85.9 Ampère per μsecond and 66 Ampère per μsecond, respectively, for male and female subjects (a “figure-of-eight” coil and magnetic stimulator MagLite, Dantec/Medtronic, have been used), HRV spectrum analysis (cStress software) has been performed (during 5 minutes, in supine position). Results: In both subjects, LF power, HF power and LF/HF ratio results, before and after rTMS administration, pointed towards sympathetic attenuation and parasympathetic augmentation (respectively, in male/female subject: decreased LF power—65.1 nu/69.3 nu, before rTMS;56.1 nu/41.6 nu, after rTMS;increased HF power—15.5 nu/22.9 nu, before rTMS;30.9 nu/45.5 nu, after rTMS). Conclusions: In this preliminary investigation, the existence of a link between “mind” and heart’s function has been put in evidence, through a reversible “virtual” lesion, of brain systems involved in cardiovascular control, caused by TMS. Repetitive TMS over mPFC decreased brain function involved in stressorevoked cardiovascular reactivity, suggesting the importance of TMS in the management of stress-related cardiovascular disorders.