The surface-enhanced Raman scattering(SERS) optical fiber probes were successfully prepared by self-assembling on polyelectrolyte multilayers. Gold nanorods(Au NRs) were used as SERS enhancement material to give excel...The surface-enhanced Raman scattering(SERS) optical fiber probes were successfully prepared by self-assembling on polyelectrolyte multilayers. Gold nanorods(Au NRs) were used as SERS enhancement material to give excellent biological affinity and stability to the SERS optical fiber probes. Au NRs were synthesized by seed growth method. The synergistic effect between AgNO_(3) and surfactant was investigated, and the highest yield was found when AgNO_(3) was 500 uL. Meanwhile, different SERS optical fiber probes were obtained by selecting silane coupling agent, polyelectrolyte multilayer and graphene oxide(GO) to treat quartz fiber. It was found that the SERS optical fiber probes obtained by the self-assembled on polyelectrolyte multilayers method performed better than those by other methods. In addition, Mapping was combined with finite element simulation to analyze the electromagnetic field distribution at the fiber end face.The electromagnetic field distribution of Au NRs was investigated, the difference of electromagnetic field intensity around the Au NRs with different arrangements was compared, the strongest signal was obtained when the Au NRs were head-to-head. Finally, sensitivity of the optimized SERS optical fiber probes could reach 10^(-9)mol/L, with excellent stability and repeatability.展开更多
We present a design, construction and characterization of different variations of GRIN and ball fiber lenses, which were recently proposed for ultra-small biomedical imaging probes. Those fiber lens modules are made o...We present a design, construction and characterization of different variations of GRIN and ball fiber lenses, which were recently proposed for ultra-small biomedical imaging probes. Those fiber lens modules are made of a single mode fiber and a GRIN or ball fiber lens with or without a fiber spacer between them. The lens diameters are smaller than 0.3 mm. We discuss design methods, fabrication techniques, and measuring performance of the fiber lenses. The experimental results are compared to their modeling results. The fabrication of a high quality beam director for both lens types is presented as well. These fiber integrated beam directors could be added on the tips of the fiber lenses for side-view probes. A needle probe made by these fiber lenses is demonstrated as a sample of the ultra-small probe for biomedical imaging application. In vivo human finger images acquired by a swept source optical coherence tomography using the fiber lenses with different beam profiles were shown, which indicates the important impact of展开更多
Ultrasensitive nanomechanical instruments,e.g.atomic force microscopy(AFM),can be used to perform delicate biomechanical measurements and reveal the complex mechanical environment of biological processes.However,these...Ultrasensitive nanomechanical instruments,e.g.atomic force microscopy(AFM),can be used to perform delicate biomechanical measurements and reveal the complex mechanical environment of biological processes.However,these instruments are limited because of their size and complex feedback system.In this study,we demonstrate a miniature fiber optical nanomechanical probe(FONP)that can be used to detect the mechanical properties of single cells and in vivo tissue measurements.A FONP that can operate in air and in liquids was developed by programming a microcantilever probe on the end face of a single-mode fiber using femtosecond laser two-photon polymerization nanolithography.To realize stiffness matching of the FONP and sample,a strategy of customizing the microcantilever’s spring constant according to the sample was proposed based on structure-correlated mechanics.As a proof-of concept,three FONPs with spring constants varying from 0.421 N m^(−1)to 52.6 N m^(−1)by more than two orders of magnitude were prepared.The highest microforce sensitivity was 54.5 nmμN^(−1)and the detection limit was 2.1 nN.The Young’s modulus of heterogeneous soft materials,such as polydimethylsiloxane,muscle tissue of living mice,onion cells,and MCF-7 cells,were successfully measured,which validating the broad applicability of this method.Our strategy provides a universal protocol for directly programming fiber-optic AFMs.Moreover,this method has no special requirements for the size and shape of living biological samples,which is infeasible when using commercial AFMs.FONP has made substantial progress in realizing basic biological discoveries,which may create new biomedical applications that cannot be realized by current AFMs.展开更多
Novel hollow Au Ag alloy nano urchins were synthesized via Ag seeds growth method,and self-assembly coated on the wall and end-tip of silica fiber for fiber probe fabrication.The nano urchins homogeneously distributed...Novel hollow Au Ag alloy nano urchins were synthesized via Ag seeds growth method,and self-assembly coated on the wall and end-tip of silica fiber for fiber probe fabrication.The nano urchins homogeneously distributed on fiber surface because of fiber silanization.The sizes and tip sharpness of the nano-urchins could be controlled by Ag seeds.The elements distribution analysis indicated there was high Ag content in tip-top for better surface enhance Raman scattering performance.The detectable concentration could be as low as 10-8 M using crystal violet molecules as analyte.Moreover,the fiber probes were stable in air,due to Au in the alloy.This fiber probe could be used for low content single molecular analysis.展开更多
We demonstrated a chemical process in the fabrication of a SERS fiber probe with an ultrahigh sensitivity.The synthesis was carried out by preparing Au@Ag core-shell nanorods (Au@Ag-NRs) selfassembled on polyelectroly...We demonstrated a chemical process in the fabrication of a SERS fiber probe with an ultrahigh sensitivity.The synthesis was carried out by preparing Au@Ag core-shell nanorods (Au@Ag-NRs) selfassembled on polyelectrolyte (PE) multilayers,for which Au@Ag-NRs were controlled by adjusting the silver layer thickness.The effect of silver layer thickness of Au@Ag-NRs on the SERS performance of the fiber probe was investigated.The SERS fiber probe shows the best performance when the silver layer thickness is controlled at 8.57 nm.Under the condition of optimizing silver layer thickness,the fiber probe exhibits ultra-high sensitivity (i e,10^(-10) M crystalline violet,CV),good reproducibility (i e,RSD of 3.5%) and stability.Besides,electromagnetic field distribution of the SERS fiber probe was also investigated.The strongest enhancement is found within the core of fiber,whereas a weakened electromagnetic field exists in the fiber cladding layer.The SERS fiber probe can be a good candidate in ultra-trace detection for biomedical and environmental areas.展开更多
Bubble plumes are important during the process of air-sea exchange,and optical-fiber phase detection is a suitable way to observe bubble plumes entrained by breaking waves.This paper designs a new optical-fiber probe(...Bubble plumes are important during the process of air-sea exchange,and optical-fiber phase detection is a suitable way to observe bubble plumes entrained by breaking waves.This paper designs a new optical-fiber probe(OFP)made of sapphire to overcome the limitations of existing materials(e.g.,high brittleness,poor corrosion resistance,and narrow bandwidth)and thereby enhance the detection performance of the OFP by improving its structure.Based on total internal reflection and light refraction,a simulation model of the probe is established in the Zemax optical design software to optimize the probe tip and matching mode of the two probe tips.The results show that the optimum OFP tip is a conical sapphire one with a cone angle of 35°.Tests are then conducted on a bespoke OFP sensor,the results of which are consistent with those predicted theoretically.The simulation results lay the foundation for the integrated design of OFP sensors and the optimization of their internal optics.The findings could also be applied to OFPs with multiple tips.展开更多
Transmission properties of tapered fiber including right cone fiber and bend optical fiber are discussed.The transmission efficiency of the tapered fiber is measured.The curve of transmission efficiency versus taper c...Transmission properties of tapered fiber including right cone fiber and bend optical fiber are discussed.The transmission efficiency of the tapered fiber is measured.The curve of transmission efficiency versus taper cone angle is given.By the scalar wave equation and Gaussian approximation,transmission properties of the two kinds of tapered fibers are analyzed,the power losses caused by taper cone angle and by the bending are also calculated.From the experiments and theoretical analysis,it could come to a conclusion that the wider the taper cone angle is,the higher the transmission efficiency will be.展开更多
粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.12...粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.125 g TNT当量的微型炸药球作为爆炸源,进行填实爆炸产生应力波,通过采集光纤探针端面的运动信息,基于短时傅里叶变换的时频分析方法,解调出端面运动速度,进而反推出粒子速度。实验结果表明:不同光纤镀膜探针测得的速度分别为22.648 m/s、23.505 m/s,将反推的粒子速度与传统的圆环型电磁粒子速度计方法获取到的数据进行对比,两者的相对偏差低于5.00%,验证了光纤镀膜探针测量固体介质中应力波粒子速度的可行性。展开更多
Fabrication method and device of ultra-small gradient-index (GRIN) fiber probe were investigated in order to explore the development of ultra-small probes for optical coherence tomography (OCT) imaging. The beam- ...Fabrication method and device of ultra-small gradient-index (GRIN) fiber probe were investigated in order to explore the development of ultra-small probes for optical coherence tomography (OCT) imaging. The beam- expanding effect of no-core fiber (NCF) and the focusing properties of the GRIN fiber lens were analyzed based on the model of GRIN fiber probe consisting of single-mode fiber (SMF), NCF and GRIN fiber lens. A stereo micro- scope based system was developed to fabricate the GRIN fiber probe. A fiber fusion splicer and an ultrasonic cleaver were used to weld and cut the fiber respectively. A con- focal microscopy was used to measure the dimensions of probe components. The results show that the sizes of probe components developed are at the level of millimeter. Therefore, the proposed experimental system meets the fabrication requirements of an ultra-small self-focusing GRIN fiber probe. This shows that this fabrication device and method can be employed in the fabrication of ultra- small self-focusing GRIN fiber probe and applied in the study of miniaturized optical probes and OCT systems.展开更多
Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power s...Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power signal in a long distance, the fiber technology is applied in this setup.展开更多
A new optical fiber fluoroptic thermometer based on the temperature—fluoroptic characteristic of fluoroptic materials is presented.The ratio technique of intensities of fluorescent emission lines of certain rare eart...A new optical fiber fluoroptic thermometer based on the temperature—fluoroptic characteristic of fluoroptic materials is presented.The ratio technique of intensities of fluorescent emission lines of certain rare earth phosphors is used,making the measurement of temperatures of the system to 0.5 ℃ precision. The characteristics of thermometer are discussed and the experiment results of temperature are given.展开更多
Complex surface shape measurement has been a focus topic in the CAD/CAM field. A popular method for measuring dimensional information is using a 3D coordinate measuring machine (CMM)with a touch trigger probe. The mea...Complex surface shape measurement has been a focus topic in the CAD/CAM field. A popular method for measuring dimensional information is using a 3D coordinate measuring machine (CMM)with a touch trigger probe. The measurement set up with CMM, however, is a time consuming task and the accuracy of the measurement deteriorates as the speed of measurement increase. Non-contact measurement is favored since high speed measurement can be achieved and problems with vibration and friction can be eliminated. Although much research has been conducted in non-contact measurement using image capturing and processing schemes, accuracy is poor and measurement is limited. Some optical technologies developed provide a good accuracy but the dynamic range and versatility is very limited. A novel fiber-optic sensor used for the inspection of complex internal contours is presented in this paper, which is able to measure a surface shape in a non-contact manner with high accuracy and high speed, and is compact and flexible to be incorporated into a CMM. Modulation functions for tilted surface shape measurement, based on the Gaussian distribution of the emitting beam from single-mode fiber (SMF), were derived for specular reflection. The feasibility of the proposed measurement principle was verified by simulations.展开更多
基金Funded by National Natural Science Foundation of China (Nos.51372179, 51772224)the Open Projects Foundation of Yangtze Optical Fiber and Cable Joint Stock Limited Company (YOFC)(No.SKLD1705)。
文摘The surface-enhanced Raman scattering(SERS) optical fiber probes were successfully prepared by self-assembling on polyelectrolyte multilayers. Gold nanorods(Au NRs) were used as SERS enhancement material to give excellent biological affinity and stability to the SERS optical fiber probes. Au NRs were synthesized by seed growth method. The synergistic effect between AgNO_(3) and surfactant was investigated, and the highest yield was found when AgNO_(3) was 500 uL. Meanwhile, different SERS optical fiber probes were obtained by selecting silane coupling agent, polyelectrolyte multilayer and graphene oxide(GO) to treat quartz fiber. It was found that the SERS optical fiber probes obtained by the self-assembled on polyelectrolyte multilayers method performed better than those by other methods. In addition, Mapping was combined with finite element simulation to analyze the electromagnetic field distribution at the fiber end face.The electromagnetic field distribution of Au NRs was investigated, the difference of electromagnetic field intensity around the Au NRs with different arrangements was compared, the strongest signal was obtained when the Au NRs were head-to-head. Finally, sensitivity of the optimized SERS optical fiber probes could reach 10^(-9)mol/L, with excellent stability and repeatability.
文摘We present a design, construction and characterization of different variations of GRIN and ball fiber lenses, which were recently proposed for ultra-small biomedical imaging probes. Those fiber lens modules are made of a single mode fiber and a GRIN or ball fiber lens with or without a fiber spacer between them. The lens diameters are smaller than 0.3 mm. We discuss design methods, fabrication techniques, and measuring performance of the fiber lenses. The experimental results are compared to their modeling results. The fabrication of a high quality beam director for both lens types is presented as well. These fiber integrated beam directors could be added on the tips of the fiber lenses for side-view probes. A needle probe made by these fiber lenses is demonstrated as a sample of the ultra-small probe for biomedical imaging application. In vivo human finger images acquired by a swept source optical coherence tomography using the fiber lenses with different beam profiles were shown, which indicates the important impact of
基金supported by the National Natural Science Foundation of China(NSFC)(62122057,62075136,62175165)Natural Science Foundation of Guangdong Province(2022B1515120061,2019B1515120042)Science and Technology Innovation Commission of Shenzhen(RCYX20200714114524139,JCYJ20200109114001806).
文摘Ultrasensitive nanomechanical instruments,e.g.atomic force microscopy(AFM),can be used to perform delicate biomechanical measurements and reveal the complex mechanical environment of biological processes.However,these instruments are limited because of their size and complex feedback system.In this study,we demonstrate a miniature fiber optical nanomechanical probe(FONP)that can be used to detect the mechanical properties of single cells and in vivo tissue measurements.A FONP that can operate in air and in liquids was developed by programming a microcantilever probe on the end face of a single-mode fiber using femtosecond laser two-photon polymerization nanolithography.To realize stiffness matching of the FONP and sample,a strategy of customizing the microcantilever’s spring constant according to the sample was proposed based on structure-correlated mechanics.As a proof-of concept,three FONPs with spring constants varying from 0.421 N m^(−1)to 52.6 N m^(−1)by more than two orders of magnitude were prepared.The highest microforce sensitivity was 54.5 nmμN^(−1)and the detection limit was 2.1 nN.The Young’s modulus of heterogeneous soft materials,such as polydimethylsiloxane,muscle tissue of living mice,onion cells,and MCF-7 cells,were successfully measured,which validating the broad applicability of this method.Our strategy provides a universal protocol for directly programming fiber-optic AFMs.Moreover,this method has no special requirements for the size and shape of living biological samples,which is infeasible when using commercial AFMs.FONP has made substantial progress in realizing basic biological discoveries,which may create new biomedical applications that cannot be realized by current AFMs.
基金Funded by the Project of Sanya Yazhou Bay Science and Technology City (No.SCKJ-JYRC-2022-44)the Opening Funding of the State Key Laboratory of Silicate Materials for Architecture (SySJJ2018-06)+1 种基金the Fundamental Research Funds for the Central Universities (WUT:2016VA096),Chinathe Research Program (No.S2634339)through a Grant Provided by the Ministry of SMEs and Startups。
文摘Novel hollow Au Ag alloy nano urchins were synthesized via Ag seeds growth method,and self-assembly coated on the wall and end-tip of silica fiber for fiber probe fabrication.The nano urchins homogeneously distributed on fiber surface because of fiber silanization.The sizes and tip sharpness of the nano-urchins could be controlled by Ag seeds.The elements distribution analysis indicated there was high Ag content in tip-top for better surface enhance Raman scattering performance.The detectable concentration could be as low as 10-8 M using crystal violet molecules as analyte.Moreover,the fiber probes were stable in air,due to Au in the alloy.This fiber probe could be used for low content single molecular analysis.
基金Funded by National Natural Science Foundation of China (Nos.51372179, 51772224)the Open Projects Foundation of Yangtze Optical Fiber and Cable Joint Stock Limited Company (YOFC)(No.SKLD1705)。
文摘We demonstrated a chemical process in the fabrication of a SERS fiber probe with an ultrahigh sensitivity.The synthesis was carried out by preparing Au@Ag core-shell nanorods (Au@Ag-NRs) selfassembled on polyelectrolyte (PE) multilayers,for which Au@Ag-NRs were controlled by adjusting the silver layer thickness.The effect of silver layer thickness of Au@Ag-NRs on the SERS performance of the fiber probe was investigated.The SERS fiber probe shows the best performance when the silver layer thickness is controlled at 8.57 nm.Under the condition of optimizing silver layer thickness,the fiber probe exhibits ultra-high sensitivity (i e,10^(-10) M crystalline violet,CV),good reproducibility (i e,RSD of 3.5%) and stability.Besides,electromagnetic field distribution of the SERS fiber probe was also investigated.The strongest enhancement is found within the core of fiber,whereas a weakened electromagnetic field exists in the fiber cladding layer.The SERS fiber probe can be a good candidate in ultra-trace detection for biomedical and environmental areas.
文摘Bubble plumes are important during the process of air-sea exchange,and optical-fiber phase detection is a suitable way to observe bubble plumes entrained by breaking waves.This paper designs a new optical-fiber probe(OFP)made of sapphire to overcome the limitations of existing materials(e.g.,high brittleness,poor corrosion resistance,and narrow bandwidth)and thereby enhance the detection performance of the OFP by improving its structure.Based on total internal reflection and light refraction,a simulation model of the probe is established in the Zemax optical design software to optimize the probe tip and matching mode of the two probe tips.The results show that the optimum OFP tip is a conical sapphire one with a cone angle of 35°.Tests are then conducted on a bespoke OFP sensor,the results of which are consistent with those predicted theoretically.The simulation results lay the foundation for the integrated design of OFP sensors and the optimization of their internal optics.The findings could also be applied to OFPs with multiple tips.
文摘Transmission properties of tapered fiber including right cone fiber and bend optical fiber are discussed.The transmission efficiency of the tapered fiber is measured.The curve of transmission efficiency versus taper cone angle is given.By the scalar wave equation and Gaussian approximation,transmission properties of the two kinds of tapered fibers are analyzed,the power losses caused by taper cone angle and by the bending are also calculated.From the experiments and theoretical analysis,it could come to a conclusion that the wider the taper cone angle is,the higher the transmission efficiency will be.
文摘粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.125 g TNT当量的微型炸药球作为爆炸源,进行填实爆炸产生应力波,通过采集光纤探针端面的运动信息,基于短时傅里叶变换的时频分析方法,解调出端面运动速度,进而反推出粒子速度。实验结果表明:不同光纤镀膜探针测得的速度分别为22.648 m/s、23.505 m/s,将反推的粒子速度与传统的圆环型电磁粒子速度计方法获取到的数据进行对比,两者的相对偏差低于5.00%,验证了光纤镀膜探针测量固体介质中应力波粒子速度的可行性。
基金supported by the National Natural Science Foundation of China(Grant No.41104065)the Dawn Planning Foundation of Shanghai Municipal Education Commission (Grant No.12CG047)by the Scientific Research Innovation Project of Shanghai Municipal Education Commission(Grant No. 13YZ022)
文摘Fabrication method and device of ultra-small gradient-index (GRIN) fiber probe were investigated in order to explore the development of ultra-small probes for optical coherence tomography (OCT) imaging. The beam- expanding effect of no-core fiber (NCF) and the focusing properties of the GRIN fiber lens were analyzed based on the model of GRIN fiber probe consisting of single-mode fiber (SMF), NCF and GRIN fiber lens. A stereo micro- scope based system was developed to fabricate the GRIN fiber probe. A fiber fusion splicer and an ultrasonic cleaver were used to weld and cut the fiber respectively. A con- focal microscopy was used to measure the dimensions of probe components. The results show that the sizes of probe components developed are at the level of millimeter. Therefore, the proposed experimental system meets the fabrication requirements of an ultra-small self-focusing GRIN fiber probe. This shows that this fabrication device and method can be employed in the fabrication of ultra- small self-focusing GRIN fiber probe and applied in the study of miniaturized optical probes and OCT systems.
文摘Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power signal in a long distance, the fiber technology is applied in this setup.
文摘A new optical fiber fluoroptic thermometer based on the temperature—fluoroptic characteristic of fluoroptic materials is presented.The ratio technique of intensities of fluorescent emission lines of certain rare earth phosphors is used,making the measurement of temperatures of the system to 0.5 ℃ precision. The characteristics of thermometer are discussed and the experiment results of temperature are given.
文摘Complex surface shape measurement has been a focus topic in the CAD/CAM field. A popular method for measuring dimensional information is using a 3D coordinate measuring machine (CMM)with a touch trigger probe. The measurement set up with CMM, however, is a time consuming task and the accuracy of the measurement deteriorates as the speed of measurement increase. Non-contact measurement is favored since high speed measurement can be achieved and problems with vibration and friction can be eliminated. Although much research has been conducted in non-contact measurement using image capturing and processing schemes, accuracy is poor and measurement is limited. Some optical technologies developed provide a good accuracy but the dynamic range and versatility is very limited. A novel fiber-optic sensor used for the inspection of complex internal contours is presented in this paper, which is able to measure a surface shape in a non-contact manner with high accuracy and high speed, and is compact and flexible to be incorporated into a CMM. Modulation functions for tilted surface shape measurement, based on the Gaussian distribution of the emitting beam from single-mode fiber (SMF), were derived for specular reflection. The feasibility of the proposed measurement principle was verified by simulations.