期刊文献+
共找到39篇文章
< 1 2 >
每页显示 20 50 100
Multi-model Predictive Control of Ultra-supercritical Coal-fired Power Unit 被引量:6
1
作者 王国良 阎威武 +2 位作者 陈世和 张曦 邵惠鹤 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2014年第7期782-787,共6页
The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi... The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi-model and double layered optimization is introduced for coordinated control of USC unit. The linear programming(LP) combined with quadratic programming(QP) is used in steady optimization for computation of the ideal value of dynamic optimization. Three inputs(i.e. valve opening, coal flow and feedwater flow) are employed to control three outputs(i.e. load, main steam temperature and main steam pressure). The step response models for the dynamic matrix control(DMC) are constructed using the three inputs and the three outputs. Piecewise models are built at selected operation points. Double-layered multi-model predictive controller is implemented in simulation with satisfactory performance. 展开更多
关键词 ultra-supercritical power unit Coordinated control Multi-model constrained predictive control
下载PDF
Exergy Analysis and Thermal Optimization of a Double-Turbine Regeneration System in a Ultra-Supercritical Double-Reheat Unit 被引量:2
2
作者 Shidan Chi Tao Luan +2 位作者 Yan Liang Xundong Hu Yan Gao 《Fluid Dynamics & Materials Processing》 EI 2021年第1期71-80,共10页
Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat ... Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat degree ofextraction steam in an ultra-supercritical (USC) double-reheat unit is considered. Using a 1000 MW power plantas an example, two systems (case 1 and case 2) are proposed, both working in combination with a regenerativesteam turbine. The thermal performances of these two systems are compared with that of the original systemthrough a heat balance method and an exergy balance strategy. The results reveal that the two coupled systemscan significantly reduce the superheat degree of extraction steam, turbine heat rate, and coal consumption of theunit and improve the energy utilization efficiency. These results will provide useful theoretical guidance to futureinvestigators wishing to address the general problem relating to energy conservation and modelling of the coupledextraction steam regenerative system of USC double-reheat units. 展开更多
关键词 ultra-supercritical unit exergy loss thermal performance regenerative steam turbine superheat degree
下载PDF
Vibration of 1000-MW Ultra-Supercritical Turbine-Generator Unit with Simens Technology
3
作者 Zhang Xueyan Zhang Weijun Ge Xiang He Guoan 《Electricity》 2012年第5期48-54,58,共8页
The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration ... The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration diagnosis and treatment for more than 10 units, some typical vibration faults were summarized, such as the vibration fluctuation of the high pressure (HP) rotor, abnormal vibration increases of the No.3 bearing pedestal and large vibration of the exciter rotor during its critical speed range. The vibration characteristics and the causes of faults and countermeasures were analyzed. Three applications for further illustration were given. The vibration fault identification method, control measures, and applications can provide a reference for vibration diagnoses and treatment of same type units. 展开更多
关键词 1 000-MW ultra-supercritical unit VIBRATION single bearing support rotor (thermal) unbalance rotor dynamic (thermal) balance
下载PDF
智能控制系统在超超临界百万机组中的应用
4
作者 于全波 《中国高新科技》 2024年第17期80-82,共3页
智能控制系统是比分散控制系统更智能、更灵活、更可靠的控制系统形式,能够改善分散控制系统无法应用先进算法、重复报警等现象,使超超临界百万机组的运行更稳定、更经济,更符合电力企业的生产发展需要。文章从智能控制系统的组态方案入... 智能控制系统是比分散控制系统更智能、更灵活、更可靠的控制系统形式,能够改善分散控制系统无法应用先进算法、重复报警等现象,使超超临界百万机组的运行更稳定、更经济,更符合电力企业的生产发展需要。文章从智能控制系统的组态方案入手,分析更适合机组的算法,探讨数据进入算法前的预处理,目的在于提升超超临界百万机组的控制智能化水平。 展开更多
关键词 智能控制系统 超超临界百万机组 算法 数据
下载PDF
Energy-Saving Optimization Study on 700℃ Double Reheat Advanced Ultra-Supercritical Coal-Fired Power Generation System
5
作者 WANG Jing DUAN Liqiang +3 位作者 YANG Jinfu YANG Ming JING Yutian TIAN Liguo 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第1期30-43,共14页
700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss prob... 700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss problem caused by the high superheat degrees of regenerative steam extractions in 700°C double reheat advanced ultra-supercritical power generation system,two optimization systems are proposed in this paper.System 1 is integrated with the back pressure extraction steam turbine,and system 2 is simultaneously integrated with both the outside steam cooler and back pressure extraction steam turbine.The system performance models are built by the Ebsilon Professional software.The performances of optimized systems are analyzed by the unit consumption method.The off-design performances of optimization systems are analyzed.The results show that:the standard power generation coal consumption rates of optimization systems 1 and 2 are decreased by 1.88 g·(kW·h)^(–1),2.97 g·(kW·h)^(–1)compared with that of the 700°C reference system;the average superheat degrees of regenerative steam extractions of optimized systems 1 and 2 are decreased by 122.2°C,140.7°C(100%turbine heat acceptance condition),respectively.The comparison results also show that the performance of the optimized system 2 is better than those of the optimized system 1 and the 700°C reference system.The power generation standard coal consumption rate and the power generation efficiency of the optimized system 2 are about 232.08 g·(kW·h)^(–1)and 52.96%(100%turbine heat acceptance condition),respectively. 展开更多
关键词 700℃ advanced ultra-supercritical(A-USC) double reheat cycle extraction steam superheat degree unit consumption method system optimization
原文传递
地学时间单位Ma和Myr及其派生单位用法的探讨 被引量:2
6
作者 李成俊 骆振福 +2 位作者 邓群 靳晓艳 王继红 《煤田地质与勘探》 CAS CSCD 北大核心 2010年第2期79-80,共2页
针对夏明生先生认为"Ma"及其派生单位(如"m/Ma"和"℃/Ma")在地学期刊中属错误用法的观点,查阅了国家标准GB 3100-93和国际地学期刊有关规定。进而提出"Ma"和"Myr"均可表示"100... 针对夏明生先生认为"Ma"及其派生单位(如"m/Ma"和"℃/Ma")在地学期刊中属错误用法的观点,查阅了国家标准GB 3100-93和国际地学期刊有关规定。进而提出"Ma"和"Myr"均可表示"100万年"的观点,并指出这两个单位在国际期刊用法中的区别,即"Ma"用于表示某一地质事件距今的绝对年代(absolute dates),而"Myr"用于表示某一地质事件的延续时间或时间间隔(duration或interval)。另外,还提出了Ma"和"Myr"的派生单位供大家讨论。 展开更多
关键词 地学时间单位 派生单位 百万年 温度速率
下载PDF
全焊接板式换热器在1000万t级炼油装置的应用 被引量:5
7
作者 徐成裕 靳贤锐 刘飞 《石油化工设备技术》 CAS 2016年第5期52-57,5,共6页
全焊接板式换热器具有结构紧凑、换热效率高、耐腐蚀、拆卸方便等特点。为解决常减压装置常顶换热器腐蚀问题,中国石油化工股份有限公司镇海炼化分公司在2012年检修中,将原常顶U型管式换热器替换为全焊接板式换热器,实现了全焊接板式换... 全焊接板式换热器具有结构紧凑、换热效率高、耐腐蚀、拆卸方便等特点。为解决常减压装置常顶换热器腐蚀问题,中国石油化工股份有限公司镇海炼化分公司在2012年检修中,将原常顶U型管式换热器替换为全焊接板式换热器,实现了全焊接板式换热器在1 000万t炼油装置的应用。经过一个周期的使用,大幅减少了常顶腐蚀泄漏的频率,收到了较好的使用效果。文章着重阐述了全焊接板换在本周期使用情况与存在问题,并分析了设备泄漏的原因,提出落实改进方案,同时提出了装置长周期运行的预防措施。 展开更多
关键词 全焊接板式换热器 腐蚀 1000万吨级炼油装置 长周期
下载PDF
凝汽器冷却管长度优化设计研究 被引量:5
8
作者 徐正 于喜文 《黑龙江电力》 CAS 2017年第6期561-564,共4页
考虑到汽轮机厂对冷却管的设计优化仅是对凝汽器本身的优化,其冷却管长度的选取对整个系统而言可能并不是最优值。采用优化后的冷却塔、循环水泵、凝汽器面积、循环水管道的配置,通过对凝汽器进行热力、水力的详细计算,确定最优的冷却... 考虑到汽轮机厂对冷却管的设计优化仅是对凝汽器本身的优化,其冷却管长度的选取对整个系统而言可能并不是最优值。采用优化后的冷却塔、循环水泵、凝汽器面积、循环水管道的配置,通过对凝汽器进行热力、水力的详细计算,确定最优的冷却管长度。经过几种方案的比选,某1 000 MW火力发电机组的凝汽器推荐采用长度为13 m冷却管。 展开更多
关键词 凝汽器 冷却管 循环水系统 百万机组 冷端优化
下载PDF
老年患者用1/20万U肾上腺素的2%利多卡因麻醉拔牙过程中心血管的监护 被引量:1
9
作者 曹军 邓海平 《实用临床医学(江西)》 CAS 2009年第1期86-88,共3页
目的观察含1/20万U肾上腺素的2%利多卡因局部麻醉在老年患者拔牙中对呼吸、心血管的影响。方法130例老年患者采用含1/20万U肾上腺素的2%利多卡因作拔牙麻醉。监护拔牙手术前、局麻后、拔牙后的呼吸、心率、血压及心电图的变化,就其结果... 目的观察含1/20万U肾上腺素的2%利多卡因局部麻醉在老年患者拔牙中对呼吸、心血管的影响。方法130例老年患者采用含1/20万U肾上腺素的2%利多卡因作拔牙麻醉。监护拔牙手术前、局麻后、拔牙后的呼吸、心率、血压及心电图的变化,就其结果进行自身对照分析。结果1/20万U肾上腺素的2%利多卡因局部麻醉对老年拔牙患者的呼吸、心率、血压及心电图均无明显的影响。结论1/20万U肾上腺素的2%利多卡因对老年拔牙患者作局部麻醉是安全的,不应视为禁忌。 展开更多
关键词 1/20万u肾上腺素的2%利多卡因 老年患者 心血管监护
下载PDF
660MW超超临界机组受热面超温优化策略研究
10
作者 夏永俊 夏猛 +2 位作者 幸双喜 王潜 熊体化 《锅炉制造》 2015年第1期1-4,共4页
本文通过试验研究,分析了660MW超超临界机组锅炉在运行过程中出现受热面管壁超温的原因,并总结了经济可行的优化策略。根据该策略进行调整优化后,可使锅炉在主再热汽温升至额定参数时,受热面管壁温度仍然低于超温报警值较多,彻底解决了... 本文通过试验研究,分析了660MW超超临界机组锅炉在运行过程中出现受热面管壁超温的原因,并总结了经济可行的优化策略。根据该策略进行调整优化后,可使锅炉在主再热汽温升至额定参数时,受热面管壁温度仍然低于超温报警值较多,彻底解决了受热面管壁超温的难题。该炉型是同样技术百万机组的缩小版,因此本文研究成果对同炉型的660MW和1000MW机组的锅炉运行具有很强的指导意义。 展开更多
关键词 超超临界 受热面 超温 百万机组
下载PDF
基于1036MW机组循环水系统的节能分析 被引量:4
11
作者 林少国 黄玲燕 江永 《电站辅机》 2014年第2期24-27,共4页
应用理论分析和试验分析相结合的方法,针对火电机组汽轮机、凝汽器、循环水泵和管网系统的主要特性和相互之间的制约关系进行了分析。通过对1 036MW机组循环水系统的运行优化和改造循环泵的控制系统,提出了多种优化运行的组合方案,获得... 应用理论分析和试验分析相结合的方法,针对火电机组汽轮机、凝汽器、循环水泵和管网系统的主要特性和相互之间的制约关系进行了分析。通过对1 036MW机组循环水系统的运行优化和改造循环泵的控制系统,提出了多种优化运行的组合方案,获得循环水系统优化后的运行方式。综合煤价和电价进行比较后,已在百万机组的冷端实现了较大深度的节能降耗,在变流量时获得了最佳的节能控制。 展开更多
关键词 百万千瓦 机组 冷端 优化 循环水泵 凝汽器 节能 降耗
下载PDF
卡环式装配离心压缩机的研制 被引量:1
12
作者 王玉旌 李耀祖 聂万隆 《风机技术》 2011年第1期28-31,共4页
本文介绍了为千万吨级炼油装置研制的全新装配结构压缩机,将新装配结构与传统结构在同种设计参数条件下进行对比,得出卡环式装配结构最佳,并通过实例加以证实。
关键词 千万吨炼油 BCL离心压缩机 卡环装配 转子动力学 气动设计
下载PDF
浅谈火力发电厂锅炉钢结构安装质量控制的几个重要环节 被引量:8
13
作者 张谦 《电力技术》 2010年第7期45-49,共5页
随着机组容量增大,锅炉钢结构跨度及重量也相应增加,结构也变得更为复杂。根据天津北疆发电厂1号机组锅炉钢结构施工经验,对百万机组锅炉钢结构施工质量控制的几个重要环节有针对性地进行了阐述。
关键词 超超临界 百万机组 钢结构 质量控制
下载PDF
国产高压变频器在百万机组的运行可靠性研究 被引量:2
14
作者 赵曙伟 《电气传动》 北大核心 2014年第12期70-72,89,共4页
广东台山电厂二期2台百万机组的凝结水泵使用了国产高压变频器,为了提高运行可靠性,需要从设计选型、运行控制、日常维护等各个环节进行详细分析并采取相应的预控措施,通过对实际应用情况和应用中出现的问题进行阐述,提出对提高高压变... 广东台山电厂二期2台百万机组的凝结水泵使用了国产高压变频器,为了提高运行可靠性,需要从设计选型、运行控制、日常维护等各个环节进行详细分析并采取相应的预控措施,通过对实际应用情况和应用中出现的问题进行阐述,提出对提高高压变频器运行可靠性的一些注意事项,最终达到了提高凝结水系统稳定可靠性的目的。 展开更多
关键词 高压变频器 百万机组 可靠性
下载PDF
百万级燃煤机组630℃二次再热方案增量投资及经济分析 被引量:2
15
作者 李永胜 《黑龙江电力》 CAS 2019年第6期555-558,共4页
与常规的一次再热机组相比,高参数、高性能指标的燃煤发电技术在提高火电机组发电效率、污染物排放控制、节能减排等方面有明显的优势。但同时,先进工艺设备和技术的投入必然引起投资的增加,其经济性值得探讨。依据国内数个百万级燃煤... 与常规的一次再热机组相比,高参数、高性能指标的燃煤发电技术在提高火电机组发电效率、污染物排放控制、节能减排等方面有明显的优势。但同时,先进工艺设备和技术的投入必然引起投资的增加,其经济性值得探讨。依据国内数个百万级燃煤机组工程,在实际运行状况和数据分析的基础上,阐述了百万级燃煤机组630℃二次再热方案与常规600℃一次再热方案相比的增量投资及其主要组成,并结合节煤效益进一步分析其增量投资的经济性。分析结果表明,增量投资约13亿元,三大主机是投资增加的主要因素。在目前给定的条件下测算,15年左右才能回收增量投资,回收期偏长。 展开更多
关键词 百万级燃煤机组 630℃二次再热 增量投资 热经济性
下载PDF
6 Sigma管理法的基本理念与统计参数研究 被引量:1
16
作者 贾新征 曹明兰 《建筑管理现代化》 2007年第5期26-29,共4页
介绍了6 Sigma管理法的基本理念,探讨了连续特性和离散特性Sigma值与DPMO值的计算方法,讨论了长短期Sigma值的相互关系,给出了长期DPMO值与短期Sigma值的换算步骤。
关键词 6 SIGMA DPMO过程能力 过程漂移 DPU
下载PDF
百万机组水电站厂房消防灭火系统设计实践 被引量:1
17
作者 陈丁力 冯正宇 +2 位作者 刘麦桑 曹春建 骆育真 《给水排水》 CSCD 北大核心 2022年第1期100-103,共4页
白鹤滩水电站装机容量16 000MW,电站采用左、右岸两岸厂房,单岸设有8台世界单机容量最大的1 000MW水轮发电机组。考虑到电站厂房尺寸及装机规模较大,如果消防系统不可靠造成火灾蔓延,会直接影响电网运行安全。简要介绍白鹤滩水电站消防... 白鹤滩水电站装机容量16 000MW,电站采用左、右岸两岸厂房,单岸设有8台世界单机容量最大的1 000MW水轮发电机组。考虑到电站厂房尺寸及装机规模较大,如果消防系统不可靠造成火灾蔓延,会直接影响电网运行安全。简要介绍白鹤滩水电站消防灭火系统布置的概况,总结了地下厂房消火栓系统及气体灭火系统的设计要点,提出了主变压器采用高压细水雾灭火系统的解决方案。 展开更多
关键词 白鹤滩水电站 消防灭火系统 百万机组 高压细水雾 设计
下载PDF
百万千瓦等级燃煤机组二次再热与一次再热技术选型经济性对比分析 被引量:3
18
作者 陈正浩 陆正裕 《上海电力大学学报》 CAS 2022年第4期375-378,共4页
在百万千瓦等级燃煤机组技术选型中,采用二次再热技术方案比一次再热技术方案更能有效降低发电煤耗,但同时也需要承担更大投资,二者的经济性对比取决于投资项目选址区域煤价。通过分析一、二次再热机型的主流技术方案,发现二次再热技术... 在百万千瓦等级燃煤机组技术选型中,采用二次再热技术方案比一次再热技术方案更能有效降低发电煤耗,但同时也需要承担更大投资,二者的经济性对比取决于投资项目选址区域煤价。通过分析一、二次再热机型的主流技术方案,发现二次再热技术方案比一次再热技术方案标准煤耗降低约6.5 kg/MWh,厂用电率降低约0.1%,投资增加约47190万元。采用增量内部收益法,以税前项目投资内部收益率8%为基准点,测算选择二次再热机组所要求的标准煤价平衡点约为911元/t。 展开更多
关键词 百万千瓦等级燃煤机组 一次再热 二次再热 经济性对比
下载PDF
尿素水解制氨技术在百万燃煤机组上的应用 被引量:2
19
作者 牟文彪 黄斐鹏 +1 位作者 高强生 陈彪 《广东化工》 CAS 2020年第3期47-48,81,共3页
通过对某电厂两台百万机组处于高负荷工况下脱硝系统各参数的测试,比较氨蒸气流量折算纯氨流量与实测值计算理论喷氨流量得出:在高负荷工况下,1号机组两侧、2号机组A侧脱硝反应器实测值计算理论喷氨流量与氨蒸气流量折算纯氨流量的比值... 通过对某电厂两台百万机组处于高负荷工况下脱硝系统各参数的测试,比较氨蒸气流量折算纯氨流量与实测值计算理论喷氨流量得出:在高负荷工况下,1号机组两侧、2号机组A侧脱硝反应器实测值计算理论喷氨流量与氨蒸气流量折算纯氨流量的比值在0.90~1.13之间;2号机组B侧脱硝反应器实测值计算理论喷氨流量与氨蒸气流量折算纯氨流量的比值在1.24~1.32之间。 展开更多
关键词 百万机组 尿素水解 高负荷 折算值 实测值
下载PDF
核电常规岛超流量凝结水精处理设备运行试验及应用 被引量:1
20
作者 朱来松 袁劲梅 《给水排水》 CSCD 北大核心 2022年第3期80-82,共3页
随着核电机组百万化,核电凝结水精处理的处理水量不断提升,水质要求提高。为了适应处理更大的水量、更高的水质和延长树脂床的运行周期,研究现有规格柱形设备的处理能力和树脂的装填高度的关系,通过工程应用验证其可行性。
关键词 核电 百万机组 凝结水精处理 柱形设备 树脂层高度 超流速 出水硅
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部