In response to the ultrasonic scalpels with the vibrational modal coupling which leads to a decrease in efficiency,an ultrasonic scalpel based on fusiform phononic crystals(PnCs)is proposed.An accurate theoretical mod...In response to the ultrasonic scalpels with the vibrational modal coupling which leads to a decrease in efficiency,an ultrasonic scalpel based on fusiform phononic crystals(PnCs)is proposed.An accurate theoretical model is constructed,which is mainly composed of electromechanical equivalent circuit models to analyze the frequency response function and the frequency response curves of the admittance.Bragg band gaps exist in the fusiform PnCs owing to the periodic constraint,which can suppress the corresponding vibrational modes.The vibration characteristics(vibration mode,frequency,and displacement distribution)of the ultrasonic scalpel are analyzed,and the validity of the electromechanical equivalent circuit method is verified.The results indicate that other vibration modes near the working frequency can be isolated.In addition,blades based on fusiform PnCs have a function akin to that of the horn,which enables displacement amplification.展开更多
Ultrasonic scalpel design for minimally invasive surgical procedures is mainly focused on optimizing cutting performance.However,an important issue is the low fatigue life of traditional ultrasonic scalpels,which affe...Ultrasonic scalpel design for minimally invasive surgical procedures is mainly focused on optimizing cutting performance.However,an important issue is the low fatigue life of traditional ultrasonic scalpels,which affects their long-term reliability and effectiveness and creates hidden dangers for surgery.In this study,a multi-objective optimal design for the cutting performance and fatigue life of ultrasonic scalpels was proposed using finite element analysis and fatigue simulation.The optimal design parameters of resonance frequency and amplitude were determined.By setting the transition fillet and keeping the gain structure away from the node position to enable the scalpel to have a high service life with excellent cutting performance.The frequency modulation method of setting the vibration node bosses at the node position and setting the vibration antinode grooves at the antinode position was compared.Then,the mechanism of the influence of various design elements,such as tip,shank,node position,and antinode position,on the resonance frequency,amplitude,and fatigue life of the ultrasonic scalpel was analyzed,and the optimal design principles of the ultrasonic scalpel were obtained.The proposed ultrasonic scalpel design was confirmed by simulations,impedance measurements,and liver tissue cutting experiments,demonstrating its feasibility and enhanced performance.This research introduces innovative design strategies to improve the fatigue life and performance of ultrasonic scalpels to address an important issue in minimally invasive surgery.展开更多
Minimal invasive techniques have allowed for major surgical advances.We report our initial experience of performing total laparoscopic left hepatectomy(segmentsⅡ-Ⅳ)with the Lotus(laparoscopic operation by torsional ...Minimal invasive techniques have allowed for major surgical advances.We report our initial experience of performing total laparoscopic left hepatectomy(segmentsⅡ-Ⅳ)with the Lotus(laparoscopic operation by torsional ultrasound)Ultrasonic Scalpel.The perioperative and postoperative courses of the young female patient were uneventful and she is in a good general condition without complaints 18 mo after surgery.To the best of our knowledge,this is the first total laparoscopic hemihepatectomy to be performed in Greece,as well as the first laparoscopic liver resection using Lotus shears.展开更多
Male circumcision is one of the most commonly performed operations worldwide, and many novel techniques have been developed for better postoperative outcomes. The purpose of this study was to explore the feasibility o...Male circumcision is one of the most commonly performed operations worldwide, and many novel techniques have been developed for better postoperative outcomes. The purpose of this study was to explore the feasibility of applying the ultracision harmonic scalpel (UHS) for circumcision by using dogs. Sixteen adult male dogs were divided into two groups: the UHS group and the control group. The dogs were circumcised with either the UHS or a conventional scalpel. The UHS circumcision procedure and the effects were imaged 1 week after surgery. The two groups were compared with respect to the operative time and volume of blood loss. Postoperative complications, including oedema, infection, bleeding of the incision and wound dehiscence, were recorded for both groups. The mean operative time for the UHS group was only 5.1 min compared with the 35.5 min of the conventional group. The mean blood loss was less than 2 ml for the UHS group and 15 ml for the conventional group. There was only one case of mild oedema in the UHS group, but the postoperative complications in the conventional group included two cases of mild oedema, one infection of the incision and one Case of bleeding of the incision. In conclusion, circumcision using UHS is a novel technique to treat patients with phimosis and excessive foreskin, and this method has a short operative time, less blood loss and fewer complications than the conventional scalpel method. This small animal study orovides a basis for embarking on a larger-scale clinical trial of the UHS.展开更多
AIM:To compare hemorrhoidectomy with a bipolar electrothermal device or hemorrhoidectomy using an ultrasonically activated scalpel.METHODS:Sixty patients with grade Ⅲ or Ⅳ hemorrhoids were prospectively randomized t...AIM:To compare hemorrhoidectomy with a bipolar electrothermal device or hemorrhoidectomy using an ultrasonically activated scalpel.METHODS:Sixty patients with grade Ⅲ or Ⅳ hemorrhoids were prospectively randomized to undergo closed hemorrhoidectomy assisted by bipolar diathermy(group 1) or hemorrhoidectomy with the ultrasonic scalpel(group 2).Operative data were recorded,and patients were followed at 1,3,and 6 wk to evaluate complications.Independent assessors were assigned to obtain postoperative pain scores,oral analgesic requirement and satisfaction scores.RESULTS:Reduced intraoperative blood loss median 0.9 mL(95% CI:0.8-3.7) vs 4.6 mL(95% CI:3.8-7.0),P = 0.001 and a short operating time median 16(95% CI:14.6-18.2) min vs 31(95% CI:28.1-35.3) min,P < 0.0001 was observed in group 1 compared with group 2.There was a trend towards lower postoperative pain scores on day 1 group 1 median 2(95% CI:1.8-3.5) vs group 2 median 3(95% CI:2.6-4.2),P = 0.135.Reduced oral analgesic requirement during postoperative 24 h after operation median 1(95% CI:0.4-0.9) tablet vs 1(95% CI:0.9-1.3) tablet,P = 0.006 was observed in group 1 compared with group 2.There was no difference between the two groups in the degree of patient satisfaction or number of postoperative complications.CONCLUSION:Bipolar diathermy hemorrhoidectomy is quick and bloodless and,although as painful as closed hemorrhoidectomy with the ultrasonic scalpel,is associated with a reduced analgesic requirement immediately after operation.展开更多
Gastrointestinal stroma tumours(GIST) are the most common mesenchymal tumour in the digestive tract and commonly found in the stomach. The patient described in this report presented with collapse and a palpable abdomi...Gastrointestinal stroma tumours(GIST) are the most common mesenchymal tumour in the digestive tract and commonly found in the stomach. The patient described in this report presented with collapse and a palpable abdominal mass. He was found to have a large gastric GIST that penetrated through the mesocolon. Resection of the GIST was technically challenging but facilitated by a new generation ultrasonic scalpel device. In resection of gastric cancer the use of ultrasonic scalpels has been shown to reduce operating time, blood loss and length of stay. We feel that in technically challenging cases of gastric GIST the use of an ultrasonic scalpel device may be justified as well.展开更多
Since 1985, the no-scalpel vasectomy technique has been widely used outside China. The prevalence of this tech-nique has helped to increase the acceptability of male sterilization in many parts of the world. More than...Since 1985, the no-scalpel vasectomy technique has been widely used outside China. The prevalence of this tech-nique has helped to increase the acceptability of male sterilization in many parts of the world. More than 5000 physi-cians in twenty-five developing countries have been trained in the no-scalpel vasectomy technique. In the United Statesin 1995, nearly one third of vasectomies employed the no-scalpel technique, and in the whole Northern American re-gion, a total of 1100 doctors have been made familiar with the technique. Doctors believe that there are several advan-tages of the no-scalpel technique, including no incision, no stitches, faster procedure, faster recovery, less chance ofbleeding, less discomfort and high efficacy. The key steps of the technique include fixation of the vas and infiltrationanaesthesia of the spermatic cord, as well as grasping, delivering and isolating the vas. No-scalpel technique providesa good approach to expose the vas, in conjunction with which, different vas-end occlusion methods may be used.(Asian J Androl 2000; 2: 21 - 24)展开更多
Objective:The present study aims to compare the clinical efficacy of laparoscopic partial nephrectomy using a harmonic scalpel versus traditional scissor.Methods:A retrospective review was conducted in patients with l...Objective:The present study aims to compare the clinical efficacy of laparoscopic partial nephrectomy using a harmonic scalpel versus traditional scissor.Methods:A retrospective review was conducted in patients with localized renal tumors and scheduled for laparoscopic partial nephrectomy from January 2015 to December 2019.Eventually,225 patients joined this retrospective study.Patients were divided into the harmonic scalpel group or scissor group based on the method used,with 71 cases and 154 cases respectively.Propensity score matching(1:1)was performed to adjust for potential baseline confounders,and each group had 57 cases.Patient characteristics,perioperative clinical results,complications,and oncological results were compared between the two groups.Results:After matching,patient characteristics were not significantly different between the two groups.The scissor group was associated with a significantly shorter operative time(105 min vs.130 min,p<0.001),shorter warm ischemia time(19.35 min vs.22.07 min,p?0.005).However,the harmonic scalpel group was associated with significantly less estimated blood loss(20 mL vs.30 mL,p?0.013)and shorter length of stay(8 d vs.10 d,p?0.040).There was no significantly difference in indwelling time of drainage tube,perioperative complication,oncological outcomes or recurrence rates.Conclusions:The harmonic scalpel is used safely and effectively in laparoscopic partial nephrectomy,and has benefits in intraoperative blood loss and length of stay.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.62204112,12174240,and 11874253)the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20220774).
文摘In response to the ultrasonic scalpels with the vibrational modal coupling which leads to a decrease in efficiency,an ultrasonic scalpel based on fusiform phononic crystals(PnCs)is proposed.An accurate theoretical model is constructed,which is mainly composed of electromechanical equivalent circuit models to analyze the frequency response function and the frequency response curves of the admittance.Bragg band gaps exist in the fusiform PnCs owing to the periodic constraint,which can suppress the corresponding vibrational modes.The vibration characteristics(vibration mode,frequency,and displacement distribution)of the ultrasonic scalpel are analyzed,and the validity of the electromechanical equivalent circuit method is verified.The results indicate that other vibration modes near the working frequency can be isolated.In addition,blades based on fusiform PnCs have a function akin to that of the horn,which enables displacement amplification.
基金Supported by National Natural Science Foundation of China (Grant Nos.52005199,42241149)Shenzhen Fundamental Research Program of China (Grant Nos.JCYJ20200109150425085,JCYJ20220818102601004)+1 种基金Knowledge Innovation Program of Wuhan-Basic Research of China (Grant No.2022010801010203)Shenzhen Science and Technology Program of China (Grant Nos.JSGG20201103100001004,JSGG20220831105800001)。
文摘Ultrasonic scalpel design for minimally invasive surgical procedures is mainly focused on optimizing cutting performance.However,an important issue is the low fatigue life of traditional ultrasonic scalpels,which affects their long-term reliability and effectiveness and creates hidden dangers for surgery.In this study,a multi-objective optimal design for the cutting performance and fatigue life of ultrasonic scalpels was proposed using finite element analysis and fatigue simulation.The optimal design parameters of resonance frequency and amplitude were determined.By setting the transition fillet and keeping the gain structure away from the node position to enable the scalpel to have a high service life with excellent cutting performance.The frequency modulation method of setting the vibration node bosses at the node position and setting the vibration antinode grooves at the antinode position was compared.Then,the mechanism of the influence of various design elements,such as tip,shank,node position,and antinode position,on the resonance frequency,amplitude,and fatigue life of the ultrasonic scalpel was analyzed,and the optimal design principles of the ultrasonic scalpel were obtained.The proposed ultrasonic scalpel design was confirmed by simulations,impedance measurements,and liver tissue cutting experiments,demonstrating its feasibility and enhanced performance.This research introduces innovative design strategies to improve the fatigue life and performance of ultrasonic scalpels to address an important issue in minimally invasive surgery.
文摘Minimal invasive techniques have allowed for major surgical advances.We report our initial experience of performing total laparoscopic left hepatectomy(segmentsⅡ-Ⅳ)with the Lotus(laparoscopic operation by torsional ultrasound)Ultrasonic Scalpel.The perioperative and postoperative courses of the young female patient were uneventful and she is in a good general condition without complaints 18 mo after surgery.To the best of our knowledge,this is the first total laparoscopic hemihepatectomy to be performed in Greece,as well as the first laparoscopic liver resection using Lotus shears.
文摘Male circumcision is one of the most commonly performed operations worldwide, and many novel techniques have been developed for better postoperative outcomes. The purpose of this study was to explore the feasibility of applying the ultracision harmonic scalpel (UHS) for circumcision by using dogs. Sixteen adult male dogs were divided into two groups: the UHS group and the control group. The dogs were circumcised with either the UHS or a conventional scalpel. The UHS circumcision procedure and the effects were imaged 1 week after surgery. The two groups were compared with respect to the operative time and volume of blood loss. Postoperative complications, including oedema, infection, bleeding of the incision and wound dehiscence, were recorded for both groups. The mean operative time for the UHS group was only 5.1 min compared with the 35.5 min of the conventional group. The mean blood loss was less than 2 ml for the UHS group and 15 ml for the conventional group. There was only one case of mild oedema in the UHS group, but the postoperative complications in the conventional group included two cases of mild oedema, one infection of the incision and one Case of bleeding of the incision. In conclusion, circumcision using UHS is a novel technique to treat patients with phimosis and excessive foreskin, and this method has a short operative time, less blood loss and fewer complications than the conventional scalpel method. This small animal study orovides a basis for embarking on a larger-scale clinical trial of the UHS.
文摘AIM:To compare hemorrhoidectomy with a bipolar electrothermal device or hemorrhoidectomy using an ultrasonically activated scalpel.METHODS:Sixty patients with grade Ⅲ or Ⅳ hemorrhoids were prospectively randomized to undergo closed hemorrhoidectomy assisted by bipolar diathermy(group 1) or hemorrhoidectomy with the ultrasonic scalpel(group 2).Operative data were recorded,and patients were followed at 1,3,and 6 wk to evaluate complications.Independent assessors were assigned to obtain postoperative pain scores,oral analgesic requirement and satisfaction scores.RESULTS:Reduced intraoperative blood loss median 0.9 mL(95% CI:0.8-3.7) vs 4.6 mL(95% CI:3.8-7.0),P = 0.001 and a short operating time median 16(95% CI:14.6-18.2) min vs 31(95% CI:28.1-35.3) min,P < 0.0001 was observed in group 1 compared with group 2.There was a trend towards lower postoperative pain scores on day 1 group 1 median 2(95% CI:1.8-3.5) vs group 2 median 3(95% CI:2.6-4.2),P = 0.135.Reduced oral analgesic requirement during postoperative 24 h after operation median 1(95% CI:0.4-0.9) tablet vs 1(95% CI:0.9-1.3) tablet,P = 0.006 was observed in group 1 compared with group 2.There was no difference between the two groups in the degree of patient satisfaction or number of postoperative complications.CONCLUSION:Bipolar diathermy hemorrhoidectomy is quick and bloodless and,although as painful as closed hemorrhoidectomy with the ultrasonic scalpel,is associated with a reduced analgesic requirement immediately after operation.
文摘Gastrointestinal stroma tumours(GIST) are the most common mesenchymal tumour in the digestive tract and commonly found in the stomach. The patient described in this report presented with collapse and a palpable abdominal mass. He was found to have a large gastric GIST that penetrated through the mesocolon. Resection of the GIST was technically challenging but facilitated by a new generation ultrasonic scalpel device. In resection of gastric cancer the use of ultrasonic scalpels has been shown to reduce operating time, blood loss and length of stay. We feel that in technically challenging cases of gastric GIST the use of an ultrasonic scalpel device may be justified as well.
文摘Since 1985, the no-scalpel vasectomy technique has been widely used outside China. The prevalence of this tech-nique has helped to increase the acceptability of male sterilization in many parts of the world. More than 5000 physi-cians in twenty-five developing countries have been trained in the no-scalpel vasectomy technique. In the United Statesin 1995, nearly one third of vasectomies employed the no-scalpel technique, and in the whole Northern American re-gion, a total of 1100 doctors have been made familiar with the technique. Doctors believe that there are several advan-tages of the no-scalpel technique, including no incision, no stitches, faster procedure, faster recovery, less chance ofbleeding, less discomfort and high efficacy. The key steps of the technique include fixation of the vas and infiltrationanaesthesia of the spermatic cord, as well as grasping, delivering and isolating the vas. No-scalpel technique providesa good approach to expose the vas, in conjunction with which, different vas-end occlusion methods may be used.(Asian J Androl 2000; 2: 21 - 24)
基金This study was funded by Medical Health Science and Technology Project of Zhejiang Provincial Health Commission(2020375998).
文摘Objective:The present study aims to compare the clinical efficacy of laparoscopic partial nephrectomy using a harmonic scalpel versus traditional scissor.Methods:A retrospective review was conducted in patients with localized renal tumors and scheduled for laparoscopic partial nephrectomy from January 2015 to December 2019.Eventually,225 patients joined this retrospective study.Patients were divided into the harmonic scalpel group or scissor group based on the method used,with 71 cases and 154 cases respectively.Propensity score matching(1:1)was performed to adjust for potential baseline confounders,and each group had 57 cases.Patient characteristics,perioperative clinical results,complications,and oncological results were compared between the two groups.Results:After matching,patient characteristics were not significantly different between the two groups.The scissor group was associated with a significantly shorter operative time(105 min vs.130 min,p<0.001),shorter warm ischemia time(19.35 min vs.22.07 min,p?0.005).However,the harmonic scalpel group was associated with significantly less estimated blood loss(20 mL vs.30 mL,p?0.013)and shorter length of stay(8 d vs.10 d,p?0.040).There was no significantly difference in indwelling time of drainage tube,perioperative complication,oncological outcomes or recurrence rates.Conclusions:The harmonic scalpel is used safely and effectively in laparoscopic partial nephrectomy,and has benefits in intraoperative blood loss and length of stay.