期刊文献+
共找到16,327篇文章
< 1 2 250 >
每页显示 20 50 100
Effect of Irradiation on Crystallinity and Mechanical Properties of Ultrahigh-Molecular-Weight Polyethylene 被引量:3
1
作者 Yong ZHAO Yun Xia LUO Bing Zheng JIANG Changchun Institute of Applied Chemistry Academia Sinica, Changchun 130022 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第7期627-630,共4页
Ultrahigh-molecular-weight polyethylene(UtlMWPE) has been irradiated (0-40 Mrad) with a Co^(60) source at room temperature under vacuum. Their crystallinity has been investigated by DSC and SAXS A significant increase... Ultrahigh-molecular-weight polyethylene(UtlMWPE) has been irradiated (0-40 Mrad) with a Co^(60) source at room temperature under vacuum. Their crystallinity has been investigated by DSC and SAXS A significant increase of heat of fusion can be seen at low irradiation doses, which is attributed to crystallization caused by chain scission during the process of irradiation. It is also observed that thickness of lamellae changes with irradiation dose. Young's modulus has been improved significantly after irradiation at low doses. 展开更多
关键词 Poly Effect of Irradiation on Crystallinity and Mechanical Properties of ultrahigh-molecular-weight polyethylene SAXS
下载PDF
Hot-Drawing of Ultrahigh-Molecular-Weight Polyethylene Gel Films
2
作者 戚嵘嵘 朱清仁 +2 位作者 周持兴 刘萌戈 周贵恩 《Journal of Shanghai University(English Edition)》 CAS 2004年第1期101-108,共8页
The three stages in the hot-drawing process of ultrahigh-molecular-weight polyethylene gel films can be detected by x-ray diffraction, infrared spectroscopy, birefringence and scanning electron microscopy. In the firs... The three stages in the hot-drawing process of ultrahigh-molecular-weight polyethylene gel films can be detected by x-ray diffraction, infrared spectroscopy, birefringence and scanning electron microscopy. In the first stage of the drawing process, the lamellae in the gel films rotate and/or slip with the b-axis preferentially perpendicular to the drawing direction. With increased drawing, the c-axis of the lamellae become parallel to the stretching direction while unfolding of the chain begins, and the chains of the amorphous phase also orient along the drawing direction in the strain-chain domain. When the draw ratio is large enough, the lamellar structure is transformed into a fibrillar structure in a two-dimensional fashion. 展开更多
关键词 ultrahigh-molecular weight polyethylenes (UHMWPE) gel film hot-drawing morphological changes.
下载PDF
Polyethylene glycol fusion repair of severed rat sciatic nerves reestablishes axonal continuity and reorganizes sensory terminal fields in the spinal cord 被引量:1
3
作者 Emily A.Hibbard Liwen Zhou +5 位作者 Cathy Z.Yang Karthik Venkudusamy Yessenia Montoya Alexa Olivarez George D.Bittner Dale R.Sengelaub 《Neural Regeneration Research》 SCIE CAS 2025年第7期2095-2107,共13页
Peripheral nerve injuries result in the rapid degeneration of distal nerve segments and immediate loss of motor and sensory functions;behavioral recovery is typically poor.We used a plasmalemmal fusogen,polyethylene g... Peripheral nerve injuries result in the rapid degeneration of distal nerve segments and immediate loss of motor and sensory functions;behavioral recovery is typically poor.We used a plasmalemmal fusogen,polyethylene glycol(PEG),to immediately fuse closely apposed open ends of severed proximal and distal axons in rat sciatic nerves.We have previously reported that sciatic nerve axons repaired by PEG-fusion do not undergo Wallerian degeneration,and PEG-fused animals exhibit rapid(within 2–6 weeks)and extensive locomotor recovery.Furthermore,our previous report showed that PEG-fusion of severed sciatic motor axons was non-specific,i.e.,spinal motoneurons in PEG-fused animals were found to project to appropriate as well as inappropriate target muscles.In this study,we examined the consequences of PEG-fusion for sensory axons of the sciatic nerve.Young adult male and female rats(Sprague–Dawley)received either a unilateral single cut or ablation injury to the sciatic nerve and subsequent repair with or without(Negative Control)the application of PEG.Compound action potentials recorded immediately after PEG-fusion repair confirmed conduction across the injury site.The success of PEG-fusion was confirmed through Sciatic Functional Index testing with PEG-fused animals showing improvement in locomotor function beginning at 35 days postoperatively.At 2–42 days postoperatively,we anterogradely labeled sensory afferents from the dorsal aspect of the hindpaw following bilateral intradermal injection of wheat germ agglutinin conjugated horseradish peroxidase.PEG-fusion repair reestablished axonal continuity.Compared to unoperated animals,labeled sensory afferents ipsilateral to the injury in PEG-fused animals were found in the appropriate area of the dorsal horn,as well as inappropriate mediolateral and rostrocaudal areas.Unexpectedly,despite having intact peripheral nerves,similar reorganizations of labeled sensory afferents were also observed contralateral to the injury and repair.This central reorganization may contribute to the improved behavioral recovery seen after PEG-fusion repair,supporting the use of this novel repair methodology over currently available treatments. 展开更多
关键词 AXOTOMY dorsal horn peripheral nerve injury PLASTICITY polyethylene glycol(PEG) sciatic nerve sensory terminals wheat germ agglutinin horseradish peroxidase
下载PDF
Agglomeration of coal and polyethylene mixtures during fixed‑bed co‑gasification
4
作者 Igor G.Donskoy Aleksandr N.Kozlov +2 位作者 Maksim V.Penzik Denis A.Svishchev Lu Ding 《International Journal of Coal Science & Technology》 EI CAS CSCD 2024年第2期91-100,共10页
The article presents the results of experimental studies on the gasification of mixtures of brown coal and polyethylene(up to 20 wt%fraction)in a laboratory reactor.The work aims to study the agglomeration process dur... The article presents the results of experimental studies on the gasification of mixtures of brown coal and polyethylene(up to 20 wt%fraction)in a laboratory reactor.The work aims to study the agglomeration process during the heating and oxidation of the mixtures.The measurement results(gas composition,pressure drop)provide indirect information on the dynamics of thermal decomposition and structural changes in the fuel bed.We have shown that the interaction between polyethylene and a coal surface leads to the formation of dense agglomerates,in which the molten polymer acts as a binder.Clinkers form as a result of interfacial interactions between components and filtration flow rearranging.The hydrogen/carbon ratio in the solid residue of coal-polyethylene co-gasification increases from 0.07–0.2 to 1.11,indicating the formation of stable hydrocarbon compounds on the carbon surface.The conducted research makes it possible to identify possible interactions between chemical reactions and transfer processes that lead to agglomeration in mixtures of coal with polyethylene. 展开更多
关键词 COAL polyethylene GASIFICATION Combustion AGGLOMERATION
下载PDF
Brønsted-acid sites induced photocatalytic cracking of low-polarity polyethylene plastics
5
作者 Qianyou Wen Quan Zhang +6 位作者 Zhengzheng Liu Huining Wang Shuya Hao Fan Zhang Lijuan Zhang Qing Han Gengfeng Zheng 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第9期509-515,共7页
Polyolefins such as polyethylene(PE)are one of the largest-scale synthetic plastics and play a key role in modern society.However,polyethylene is extremely inert to chemical recycling owing to its lack of chemical fun... Polyolefins such as polyethylene(PE)are one of the largest-scale synthetic plastics and play a key role in modern society.However,polyethylene is extremely inert to chemical recycling owing to its lack of chemical functionality and low polarity,making it one of the most challenging environmental hazards globally.Herein,we developed a phosphorylated CeO_(2)catalyst by an organophosphate precursor and featured efficient photocatalysis of low-density polyethylene(LDPE)without the acid or alkaline pre-treatment.Compared to pristine CeO_(2),the surface phosphorylation allows to introduce Brønsted acid sites,which facilitate to form carbonium ions on LDPE via protonation.In addition,the suitable band structure of the phosphorylated CeO_(2)catalyst enables efficient photoabsorption and generates reactive oxygen species,leading to the C–C bond cleavage of LDPE.As a result,the phosphorylated CeO_(2)catalyst exhibited an outstanding carbon conversion rate of>94%after 48 h of photocatalysis under 50 mW/cm^(2)of simulated sunlight,with a high CO_(2)product selectivity of>99%.Furthermore,the PE microparticles with sizes larger than 10μm released from LDPE plastic wrap were directly and completely degraded by photocatalysis within 12 h,suggesting an attractive and environmentally benign strategy of utilizing solar energy-based photocatalysis for reducing potential hazards of LDPE plastic trashes. 展开更多
关键词 Photocatalytic cracking polyethylene Surface phosphorylation Bronsted-acid site Carbon conversion
下载PDF
Molecular Dynamics-Based Simulation of Polyethylene Pipe Degradation in High Temperature and High Pressure Conditions
6
作者 Guowei Feng Qing Li +5 位作者 Yang Wang Nan Lin Sixi Zha Hang Dong Ping Chen Minjun Zheng 《Fluid Dynamics & Materials Processing》 EI 2024年第9期2139-2161,共23页
High-density polyethylene(HDPE)pipes have gradually become the first choice for gas networks because of their excellent characteristics.As the use of pipes increases,there will unavoidably be a significant amount of w... High-density polyethylene(HDPE)pipes have gradually become the first choice for gas networks because of their excellent characteristics.As the use of pipes increases,there will unavoidably be a significant amount of waste generated when the pipes cease their operation life,which,if improperly handled,might result in major environmental contamination issues.In this study,the thermal degradation of polyethylene materials is simulated for different pressures(10,50,100,and 150 MPa)and temperatures(2300,2500,2700,and 2900 K)in the framework of Reactive Force Field(ReaxFF)molecular dynamics simulation.The main gas products,density,energy,and the mean square displacement with temperature and pressure are also calculated.The findings indicate that raising the temperature leads to an increase in the production of gas products,while changing the pressure has an impact on the direction in which the products are generated;the faster the temperature drops,the less dense the air;both temperature and pressure increase impact the system’s energy conversion or distribution mechanism,changing the system’s potential energy as well as its total energy;the rate at which molecules diffuse increases with temperature,and decreases with pressure.The results of this investigation provide a theoretical basis for the development of the pyrolytic treatment of polyethylene waste materials. 展开更多
关键词 ReaxFF MD high-density polyethylene DEGRADATION TEMPERATURE PRESSURE
下载PDF
Comparison between local-made and imported porous polyethylene orbital implant:a randomized controlled equivalence trial and multicenter study
7
作者 Sunisa Sintuwong Kanjana Leelapatranurak +10 位作者 Orapan Aryasit Passorn Preechawai Mingkwan Lumyongsatien Ornvenus Nimitwongsakul Jugchawin Kanokkantapong Unnkade Bhaktikamala Yongyot Tuachob Jirapol Bhuntuveh Pennung Thongtong Waraporn Suvannapruk Jintamai Suwanprateeb 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第10期1857-1863,共7页
AIM:To compare the exposure rate,infection rate,percentage of enhancement,and success rate between Medpor and the three-dimensional printed polyethylene(3DP-PE)orbital implant in a preliminary report.METHODS:This pros... AIM:To compare the exposure rate,infection rate,percentage of enhancement,and success rate between Medpor and the three-dimensional printed polyethylene(3DP-PE)orbital implant in a preliminary report.METHODS:This prospective,randomized,equivalence,controlled trial was conducted at two institutes.The equivalent margin was±10%.The sample size for the equivalence trial was 174 participants per group.Patients who were eligible for enucleations received either Medpor or 3DP-PE implants based on a randomized block of six.The surgeries were performed by five oculoplastic surgeons.The assessor and patients were masked.The magnetic resonance imaging(MRI)of the orbit was performed at least 6mo after operation and the fibrovascular ingrowth was analyzed using the Image J software.Follow-up continued at least 1y after surgery.The intention to treat and per protocol approaches were used.RESULTS:Totally 128 patients met the criteria in the report.Fifty Medpor and 553DP-PE cases completed the trial.The most common cause of blindness was trauma.The mean follow-up times of Medpor and 3DP-PE were 33 and 40mo respectively.The exposure rate was not statistically significant between two groups(6.0%and 7.3%),P<0.05,95%CI(-9.8%,+12.0%).The success rates were 94%(Medpor)and 92.7%(3DP-PE).No postoperative infection was reported.Nine patients had MRI tests and two had implant exposures with 66.3%enhancement at 75mo(Medpor)and 58%enhancement at 57mo(3DP-PE)postoperatively.CONCLUSION:There is no statistically significant difference in exposure rate and success rate between Medpor and 3DP-PE in enucleation in the report.However,we cannot conclude that they are equivalent in terms of the exposure rate and success rate because the 95%CI is wider than±10%.The infection rate is equivalent in both groups. 展开更多
关键词 orbital implants eyeball enucleation polyethylene BLINDNESS eye injuries ORBIT
下载PDF
Vertically aligned montmorillonite aerogel-encapsulated polyethylene glycol with directional heat transfer paths for efficient solar thermal energy harvesting and storage
8
作者 Qijing Guo Cong Guo +2 位作者 Hao Yi Feifei Jia Shaoxian Song 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期907-916,共10页
The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in mon... The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in montmorillonite aerogels(3D-Mt)through vacuum impregnation to prepare 3D-Mt/PEG composite PCMs.When used as a support matrix,3D-Mt can effectively prevent PEG leakage and act as a flame-retardant barrier to reduce the flammability of PEG.Simultaneously,3D-Mt/PEG demonstrates outstanding shape retention,increased thermal energy storage density,and commendable thermal and chemical stability.The phase transition enthalpy of 3D-Mt/PEG can reach 167.53 J/g and remains stable even after 50 heating-cooling cycles.Furthermore,the vertical sheet-like structure of 3D-Mt establishes directional heat transport channels,facilitating efficient phonon transfer.This configuration results in highly anisotropic thermal conductivities that ensure swift thermal responses and efficient heat conduction.This study addresses the shortcomings of PCMs,including the issues of leakage and inadequate flame retardancy.It achieves the development and design of 3D-Mt/PEG with ultrahigh strength,superior flame retardancy,and directional heat transfer.Therefore,this work offers a design strategy for the preparation of high-performance composite PCMs.The 3D-Mt/PEG with vertically aligned and well-ordered array structure developed in this research shows great potential for thermal management and photothermal conversion applications. 展开更多
关键词 montmorillonite aerogel polyethylene glycol phase change materials solar thermal energy storage flame retardant
下载PDF
Detection of internal crack growth in polyethylene pipe using guided wave ultrasonic testing
9
作者 Jay Kumar Shah Hao Wang Said El-Hawwat 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期319-329,共11页
Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe seve... Despite the success of guided wave ultrasonic inspection for internal defect detection in steel pipes,its application on polyethylene(PE)pipe remains relatively unexplored.The growth of internal cracks in PE pipe severely affects its pressure-holding capacity,hence the early detection of internal cracks is crucial for effective pipeline maintenance strategies.This study extends the scope of guided wave-based ultrasonic testing to detect the growth of internal cracks in a natural gas distribution PE pipe.Laboratory experiments and a finite element model were planned to study the wave-crack interaction at different stages of axially oriented internal crack growth with a piezoceramic transducer-based setup arranged in a pitch-catch configuration.Mode dispersion analysis supplemented with preliminary experiments was performed to isolate the optimal inspection frequency,leading to the selection of the T(0,1)mode at 50-kHz for the investigation.A transmission index based on the energy of the T(0,1)mode was developed to trace the extent of simulated crack growth.The findings revealed an inverse linear correlation between the transmission index and the crack depth for crack growth beyond 20%crack depth. 展开更多
关键词 polyethylene pipes internal cracks guided wave ultrasonic testing torsional modes finite element modeling
下载PDF
Efficient and selective removal of Pb(Ⅱ) from landfill leachate using L-serine-modified polyethylene/polypropylene nonwoven fabric synthesized via radiation grafting technique
10
作者 Xin-Xin Feng Cheng Li +6 位作者 Xuan-Zhi Mao Wan-Ning Ren Yang Gao Yu-Long He Zhe Xing Rong Li Guo-Zhong Wu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期144-155,共12页
In this study,to efficiently remove Pb(Ⅱ) from aqueous environments,a novel L-serine-modified polyethylene/polypropylene nonwoven fabric sorbent(NWF-serine)was fabricated through the radiation grafting of glycidyl me... In this study,to efficiently remove Pb(Ⅱ) from aqueous environments,a novel L-serine-modified polyethylene/polypropylene nonwoven fabric sorbent(NWF-serine)was fabricated through the radiation grafting of glycidyl methacrylate and subsequent L-serine modification.The effect of the absorbed dose was investigated in the range of 5–50 kGy.NWF-serine was characterized by Fourier transform infrared spectroscopy,thermogravimetric analysis,and scanning electron microscopy.Batch adsorption tests were conducted to investigate the influences of pH,adsorption time,temperature,initial concentration,and sorbent dosage on the Pb(Ⅱ) adsorption performance of NWF-serine.The results indicated that Pb(Ⅱ) adsorption onto NWF-serine was an endothermic process,following the pseudo-second-order kinetic model and Langmuir isotherm model.The saturated adsorption capacity was 198.1 mg/g.NWF-serine exhibited Pb(Ⅱ) removal rates of 99.8% for aqueous solutions with initial concentrations of 100 mg/L and 82.1% for landfill leachate containing competitive metal ions such as Cd,Cu,Ni,Mn,and Zn.Furthermore,NWF-serine maintained 86% of its Pb(Ⅱ) uptake after five use cycles.The coordination of the carboxyl and amino groups with Pb(Ⅱ) was confirmed using X-ray photoelectron spectroscopy and extended X-ray absorption fine structure analysis. 展开更多
关键词 Landfill leachate Radiation grafting polyethylene/polypropylene nonwoven fabric Pb(Ⅱ)removal
下载PDF
Polyethylene glycol has immunoprotective effects on sciatic allografts, but behavioral recovery and graft tolerance require neurorrhaphy and axonal fusion
11
作者 Tyler A.Smith Liwen Zhou +6 位作者 Cameron L.Ghergherehchi Michelle Mikesh Cathy Z.Yang Haley O.Tucker JuliAnne Allgood Jared S.Bushman George D.Bittner 《Neural Regeneration Research》 SCIE CAS 2025年第4期1192-1206,共15页
Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripher... Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripheral nerve allografts undergo immunological rejection by the host immune system.In contrast,peripheral nerve injuries repaired by polyethylene glycol fusion of peripheral nerve allografts exhibit excellent behavioral recovery within weeks,reduced immune responses,and many axons do not undergo Wallerian degeneration.The relative contribution of neurorrhaphy and polyethylene glycol-fusion of axons versus the effects of polyethylene glycol per se was unknown prior to this study.We hypothesized that polyethylene glycol might have some immune-protective effects,but polyethylene glycol-fusion was necessary to prevent Wallerian degeneration and functional/behavioral recovery.We examined how polyethylene glycol solutions per se affect functional and behavioral recovery and peripheral nerve allograft morphological and immunological responses in the absence of polyethylene glycol-induced axonal fusion.Ablation-type sciatic nerve injuries in outbred Sprague–Dawley rats were repaired according to a modified protocol using the same solutions as polyethylene glycol-fused peripheral nerve allografts,but peripheral nerve allografts were loose-sutured(loose-sutured polyethylene glycol)with an intentional gap of 1–2 mm to prevent fusion by polyethylene glycol of peripheral nerve allograft axons with host axons.Similar to negative control peripheral nerve allografts not treated by polyethylene glycol and in contrast to polyethylene glycol-fused peripheral nerve allografts,animals with loose-sutured polyethylene glycol peripheral nerve allografts exhibited Wallerian degeneration for all axons and myelin degeneration by 7 days postoperatively and did not recover sciatic-mediated behavioral functions by 42 days postoperatively.Other morphological signs of rejection,such as collapsed Schwann cell basal lamina tubes,were absent in polyethylene glycol-fused peripheral nerve allografts but commonly observed in negative control and loose-sutured polyethylene glycol peripheral nerve allografts at 21 days postoperatively.Loose-sutured polyethylene glycol peripheral nerve allografts had more pro-inflammatory and less anti-inflammatory macrophages than negative control peripheral nerve allografts.While T cell counts were similarly high in loose-sutured-polyethylene glycol and negative control peripheral nerve allografts,loose-sutured polyethylene glycol peripheral nerve allografts expressed some cytokines/chemokines important for T cell activation at much lower levels at 14 days postoperatively.MHCI expression was elevated in loose-sutured polyethylene glycol peripheral nerve allografts,but MHCII expression was modestly lower compared to negative control at 21 days postoperatively.We conclude that,while polyethylene glycol per se reduces some immune responses of peripheral nerve allografts,successful polyethylene glycol-fusion repair of some axons is necessary to prevent Wallerian degeneration of those axons and immune rejection of peripheral nerve allografts,and produce recovery of sensory/motor functions and voluntary behaviors.Translation of polyethylene glycol-fusion technologies would produce a paradigm shift from the current clinical practice of waiting days to months to repair ablation peripheral nerve injuries. 展开更多
关键词 allograft rejection AXOTOMY macrophage MYELIN nerve repair polyethylene glycol(PEG) sciatic nerve T cell transplantation Wallerian degeneration
下载PDF
Experimental Study of the Influence of Intrinsic Parameters on the Thermal Reactivity of Sawdust, Polyethylene Terephthalate and Composite
12
作者 Ange Brel Boukongou Timoléon Andzi Barhé 《Journal of Materials Science and Chemical Engineering》 2024年第3期9-20,共12页
Several works have been based on the study of thermal variations in biomass to derive more valuable products such as fuels capable of replacing oil in the event of a crisis or activated carbon used as an adsorbent mat... Several works have been based on the study of thermal variations in biomass to derive more valuable products such as fuels capable of replacing oil in the event of a crisis or activated carbon used as an adsorbent material, widely used in industry for the elimination of unwanted materials, both in liquid and gaseous environments. A study of thermal parameters such as: heating speed, retention time, drying temperature, carbonization temperature, particle size, was carried out with the aim of determining the characteristic factors of the carbonization of Polyethylene terephthalate (PET), sawdust (SC) and sawdust/polyethylene terephthalate (CPS) mixture. The results of the immediate analysis revealed a very low level of ash in PET (0.013%) compared to the level of ash in sawdust (2.9%), as well as a high level of fixed carbon (82.960%), which suggests the presence of mineral oxides and a significant carbon matrix unlike PET, which indicates a very significant organic matrix (essentially made up of organic matter) with the absence of mineral oxides. The study of thermal parameters showed the water loss from Sawdust (SC) and the Sawdust/Polyethylene terephthalate (CPS) mixture, an increase with temperature, unlike that of PET whose variation is essentially zero. Without heat treatment, sawdust alone contains approximately 7% water. The optimal drying temperature for this study is 110˚C for a stay of 24 hours. It appears that the largest mass losses for the PET samples are between 87.19% and 96.05%, followed by that of the mixture, between 47.33% and 64.37%. And the lowest are observed, those of sawdust (from 24.02% to 62.6%). However, here we can say that the influence of the mass is not great, given the slight difference between the losses by temperature. The results of the study of the influence of grain size showed that the differences are insignificant, even if we vary the diameter of the grains from simple to triple. To better minimize physical constraints such as the intragranular diffusibility of the volatile matter and the homogeneity of the temperature in the grains, 75 μm particles are found to be optimal for our study. It can be noted when studying the heating rate that the mass loss at the end of the reaction is approximately the same depending on each precursor material. However, it has been demonstrated that the heating rate strongly influences the nature of the reaction products both for volatile materials and for the solid residue as well as on the kinetic parameters of the chemical reaction. Furthermore, the variation in apparent density shows a decrease as a function of the increase in the residence time of the materials in the reactor. As the carbonization time increases, the apparent density decreases. We note, for the lignocellulosic material, that the apparent density stabilizes after 60 minutes. 展开更多
关键词 Intrinsic Parameters Thermal Reactivity SAWDUST polyethylene Terephthalate COMPOSITE
下载PDF
Enhancing performance of low-temperature processed CsPbI2Br all-inorganic perovskite solar cells using polyethylene oxide-modified TiO_(2)
13
作者 Xu Zhao Naitao Gao +2 位作者 Shengcheng Wu Shaozhen Li Sujuan Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第4期786-794,共9页
CsPbX_(3)-based(X=I,Br,Cl)inorganic perovskite solar cells(PSCs)prepared by low-temperature process have attracted much attention because of their low cost and excellent thermal stability.However,the high trap state d... CsPbX_(3)-based(X=I,Br,Cl)inorganic perovskite solar cells(PSCs)prepared by low-temperature process have attracted much attention because of their low cost and excellent thermal stability.However,the high trap state density and serious charge recombination between low-temperature processed TiO_(2)film and inorganic perovskite layer interface seriously restrict the performance of all-inorganic PSCs.Here a thin polyethylene oxide(PEO)layer is employed to modify TiO_(2)film to passivate traps and promote carrier collection.The impacts of PEO layer on microstructure and photoelectric characteristics of TiO_(2)film and related devices are systematically studied.Characterization results suggest that PEO modification can reduce the surface roughness of TiO_(2)film,decrease its average surface potential,and passivate trap states.At optimal conditions,the champion efficiency of CsPbI_(2)Br PSCs with PEO-modified TiO_(2)(PEO-PSCs)has been improved to 11.24%from 9.03%of reference PSCs.Moreover,the hysteresis behavior and charge recombination have been suppressed in PEO-PSCs. 展开更多
关键词 polyethylene oxide-modified TiO_(2) film low-temperature process CsPbI_(2)Br-based all-inorganic perovskite solar cells photo-voltaic performance
下载PDF
Polyethylene glycol fusion repair of severed sciatic nerves accelerates recovery of nociceptive sensory perceptions in male and female rats of different strains
14
作者 Liwen Zhou Karthik Venkudusamy +9 位作者 Emily A.Hibbard Yessenia Montoya Alexa Olivarez Cathy Z.Yang Adelaide Leung Varun Gokhale Guhan Periyasamy Zeal Pathak Dale R.Sengelaub George D.Bittner 《Neural Regeneration Research》 SCIE CAS 2025年第9期2667-2681,共15页
Successful polyethylene glycol fusion(PEG-fusion)of severed axons following peripheral nerve injuries for PEG-fused axons has been reported to:(1)rapidly restore electrophysiological continuity;(2)prevent distal Walle... Successful polyethylene glycol fusion(PEG-fusion)of severed axons following peripheral nerve injuries for PEG-fused axons has been reported to:(1)rapidly restore electrophysiological continuity;(2)prevent distal Wallerian Degeneration and maintain their myelin sheaths;(3)promote primarily motor,voluntary behavioral recoveries as assessed by the Sciatic Functional Index;and,(4)rapidly produce correct and incorrect connections in many possible combinations that produce rapid and extensive recovery of functional peripheral nervous system/central nervous system connections and reflex(e.g.,toe twitch)or voluntary behaviors.The preceding companion paper describes sensory terminal field reo rganization following PEG-fusion repair of sciatic nerve transections or ablations;howeve r,sensory behavioral recovery has not been explicitly explored following PEG-fusion repair.In the current study,we confirmed the success of PEG-fusion surgeries according to criteria(1-3)above and more extensively investigated whether PEG-fusion enhanced mechanical nociceptive recovery following sciatic transection in male and female outbred Sprague-Dawley and inbred Lewis rats.Mechanical nociceptive responses were assessed by measuring withdrawal thresholds using von Frey filaments on the dorsal and midplantar regions of the hindpaws.Dorsal von Frey filament tests were a more reliable method than plantar von Frey filament tests to assess mechanical nociceptive sensitivity following sciatic nerve transections.Baseline withdrawal thresholds of the sciatic-mediated lateral dorsal region differed significantly across strain but not sex.Withdrawal thresholds did not change significantly from baseline in chronic Unoperated and Sham-operated rats.Following sciatic transection,all rats exhibited severe hyposensitivity to stimuli at the lateral dorsal region of the hindpaw ipsilateral to the injury.However,PEG-fused rats exhibited significantly earlier return to baseline withdrawal thresholds than Negative Control rats.Furthermore,PEG-fused rats with significantly improved Sciatic Functional Index scores at or after 4 weeks postoperatively exhibited yet-earlier von Frey filament recove ry compared with those without Sciatic Functional Index recovery,suggesting a correlation between successful PEG-fusion and both motor-dominant and sensory-dominant behavioral recoveries.This correlation was independent of the sex or strain of the rat.Furthermore,our data showed that the acceleration of von Frey filament sensory recovery to baseline was solely due to the PEG-fused sciatic nerve and not saphenous nerve collateral outgrowths.No chronic hypersensitivity developed in any rat up to 12 weeks.All these data suggest that PEG-fusion repair of transection peripheral nerve injuries co uld have important clinical benefits. 展开更多
关键词 autophagia AXOTOMY collateral sprouting neuropathic pain peripheral nerve repair polyethylene glycol fusion(PEG-fusion) saphenous nerve sensory neurons sex and strain Wallerian degeneration
下载PDF
The Impact of the Inclusion of MgO Nano-Fillers in a Polyethylene Matrix on Dielectric Strength and Resistance to Partial Discharges
15
作者 Virginie Griseri Dominique Mary +1 位作者 David Malec Eric David 《Open Journal of Applied Sciences》 2024年第3期626-634,共9页
One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study fo... One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study focused on the dielectric properties of Low-Density Polyethylene (LDPE) filled with nano-sized Magnesium Oxide (MgO) particles compounded by thermo-mechanical process and one of the purposes was to establish appropriate processing parameters in order to reach the desired dielectric properties. LDPE was used as a matrix and was reinforced by MgO particles having a nominal average size of 30 nm. The MgO nanoparticles were treated with a silane coupling agent (3-Glycidyloxypropyl Trimethoxysilane). The samples were initially prepared in a melt-mixing chamber with a MgO content of 1% wt. These pre-mixed samples were further treated by the means of thermo-mechanical mixing in a conical co-rotating twin-screw extruder in order to improve the dispersion and distribution of the MgO particles. In this report, both lifetime under a PD activity and AC dielectric strength of pure and nano-filled LDPE samples have been measured and compared. Nano-filled LDPE samples were found to exhibit an improve lifetime, without any detrimental impact on their short-term dielectric strength. This suggests that nano-filled LDPE may be for electric applications for which the dielectric materials may be exposed to partial discharge activities. This is significant result for the use of MgO-reinforced PE as an insulating material for HV cables since the resistance to PD is closely related to treeing resistance which is the main electrical degradation mechanism that leads to failure for shielded extruded power cables. 展开更多
关键词 Low Density polyethylene MgO Nanofillers Dielectric Strength Partial Discharges Resistance
下载PDF
Synthesis of Branched Polyethylene via Bulky α-Diimine Nickel(II)-Catalyzed Ethylene Chain-Walking Polymerization
16
作者 Zhengquan Dong Pei Li +1 位作者 Guoyong Xu Fuzhou Wang 《Open Journal of Organic Polymer Materials》 2024年第1期1-12,共12页
The catalysis of olefin polymerization through the chain-walking process is a subject of great interest. In this contribution, the successful synthesis of a Brookhart-type unsymmetrical α-diimine nickel catalyst Ni, ... The catalysis of olefin polymerization through the chain-walking process is a subject of great interest. In this contribution, the successful synthesis of a Brookhart-type unsymmetrical α-diimine nickel catalyst Ni, which contains both dibenzhydryl and phenyl groups, was determined by X-ray crystallography. The compound has a pseudo-tetrahedral geometry at the Ni center, showing pseudo-C2-symmetry. Upon activation with modified methylaluminoxane (MMAO), Ni1 exhibits high catalytic activity up to 1.02 × 107 g PE (mol Ni h)−1 toward ethylene polymerization, enabling the synthesis of high molecular weight branched polyethylene. The molecular weights and branching densities could be tuned over a very wide range. The polymerization results indicated the possibility of precise microstructure control, depending on the polymerization temperature. The branching densities were decreased with increasing the polymerization temperature. 展开更多
关键词 Ethylene Polymerization α-Diimine Ni(II) Complex Chain-Walking Polymerization Branched polyethylene
下载PDF
Influence of molecular weight of modified ultrahigh-molecular-weight polyethylene with Cu(II) chelate of bissalicylaldehyde-ethylenediamine on wear-resistant materials 被引量:1
17
作者 Min LIU Li WU +1 位作者 Fuqing ZHANG Jing FU 《Friction》 CSCD 2016年第2期116-123,共8页
Reciprocating friction and wear performances of pure ultrahigh-molecular-weight polyethylenes (UHMWPEs) with molecular weights (MWs) of 2, 3, 5, and 9 million and their modified UHMWPEs with 15 wt.% Cu(II) chelate of ... Reciprocating friction and wear performances of pure ultrahigh-molecular-weight polyethylenes (UHMWPEs) with molecular weights (MWs) of 2, 3, 5, and 9 million and their modified UHMWPEs with 15 wt.% Cu(II) chelate of bissalicylaldehyde-ethylenediamine (add1) against titanium alloy (Ti6Al4V) were investigated under boundary lubrication with 25 vol.% calf serum deionized water solution. Differential scanning calorimetry (DSC) of purchased UHMWPE powders was performed. The enthalpy changed with an increase in MW. UH300 had the lowest temperature of an extrapolated peak and the best peak symmetry in DSC analysis. The friction coefficient curves of molded pure and modified UHMWPEs/Ti6Al4V were compared, and the volume loss by the wear of polymers was measured. 3D topographies of the worn surfaces of polymers and images of the worn surfaces of polymers and titanium alloy against polymers were analyzed by confocal white light microscopy and scanning electron microscopy, respectively. Results showed that the influence of MW of UHMWPE was obvious on the friction and wear characteristics of pure UHMWPEs and 15% add1 UHMWPEs. An MW of 3 million was the best to reduce the friction of rubbing pairs, enhance the wear resistance of pure UHMWPEs and 15% add1-UHMWPEs, and improve the mating properties of Ti6Al4V. 展开更多
关键词 ultrahigh-molecular-weight polyethylene reciprocating friction and wear boundary lubrication molecular weight Cu(Ⅱ) chelate of bissalicylaldehyde-ethylenediamine
原文传递
Emerging low-density polyethylene/paraffin wax/aluminum composite as a form-stable phase change thermal interface material 被引量:2
18
作者 Chuanchang Li Weixuan Wang +2 位作者 Xiaoliang Zeng Chunxuan Liu Rong Sun 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第4期772-781,共10页
Thermal interface materials(TIMs) play a vital role in the thermal management of electronic devices and can significantly reduce thermal contact resistance(TCR). The TCR between the solid–liquid contact surface is mu... Thermal interface materials(TIMs) play a vital role in the thermal management of electronic devices and can significantly reduce thermal contact resistance(TCR). The TCR between the solid–liquid contact surface is much smaller than that of the solid–solid contact surface, but conventional solid–liquid phase change materials are likely to cause serious leakage. Therefore, this work has prepared a new formstable phase change thermal interface material. Through the melt blending of paraffin wax(PW) and low-density polyethylene(LDPE), the stability is improved and it has an excellent coating effect on PW. The addition of aluminum(Al) powder improves the low thermal conductivity of PW/LDPE, and the addition of 15wt% Al powder improves the thermal conductivity of the internal structure of the matrix by 67%. In addition, the influence of the addition of Al powder on the internal structure, thermal properties, and phase change behavior of the PW/LDPE matrix was systematically studied. The results confirmed that the addition of Al powder improved the thermal conductivity of the material without a significant impact on other properties, and the thermal conductivity increased with the increase of Al addition. Therefore, morphologically stable PW/LDPE/Al is an important development direction for TIMs. 展开更多
关键词 paraffin wax low-density polyethylene phase change materials thermal interface materials form stability
下载PDF
Hyponatremic encephalopathy due to polyethylene glycol-based bowel preparation for colonoscopy:A case report 被引量:1
19
作者 Yuan Zhao Hai-Sheng Dong 《World Journal of Clinical Cases》 SCIE 2023年第1期187-192,共6页
BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause ... BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause electrolyte disturbances and hyponatremia.However,hyponatremic encephalopathy due to hyponatremia induced by PEG solution,although rare,can lead to serious irreversible sequelae and even death.CASE SUMMARY In this report,we discuss a case of neurological dysfunction due to hyponatremia,also known as hyponatremic encephalopathy,observed in a 63-year-old woman who underwent PEG-based bowel preparation for colonoscopy.She was eventually transferred to our intensive care unit for treatment due to her Glasgow Coma Scale score of 9/15(Eye opening 2;Verbal response 1;Motor response 6)and abnormal laboratory tests.CONCLUSION Physicians should be thoroughly familiarized with the patient’s history before prescribing PEG for bowel preparation,and timely identification of patients with hyponatremic encephalopathy is essential as delayed treatment is associated with poor neurological outcomes.An intravenous infusion of 3%sodium chloride is recommended at the onset of early symptoms.The goal of treatment is to adequately treat cerebral edema while avoiding serum sodium correction beyond 15 to 20 m Eq/L within 48 h of treatment to prevent osmotic demyelination syndrome. 展开更多
关键词 polyethylene glycol Intestinal preparation Hyponatremic encephalopathy HYPONATREMIA BRAIN Case report
下载PDF
Natural aging mechanism of buried polyethylene pipelines during long-term service
20
作者 Ying-Chun Chen Yan-Feng Li +3 位作者 Yan Xi Qiang Li Qi Lu Jie Yang 《Petroleum Science》 SCIE EI CSCD 2023年第5期3143-3156,共14页
Currently,accelerated aging tests are widely used to study the aging process of polyethylene pipelines.However,this approach can only simulate one or several main influencing factors in the natural environment,which a... Currently,accelerated aging tests are widely used to study the aging process of polyethylene pipelines.However,this approach can only simulate one or several main influencing factors in the natural environment,which are often quite different from the actual environment of the buried pipelines.In this study,five types of PE80 buried pipelines in service for 9e18 years were taken as the research object,while new PE80 pipelines were taken as the reference group.The aging process and mechanism of polyethylene buried pipelines were studied through mechanical and chemical property tests and microstructural analysis.The results showed that the pipeline exhibited cross-linking as the main aging mechanism after being in service for 0e18 years.The aging degree and law of the inner and outer surface of the pipeline were compared,and the observed mechanism of both surfaces was explained.After 18 years in service,the elongation at the break of the pipe decreased by 16.2%,and the toughness of the matrix in the main collapse area of the tensile sample was the fundamental reason responsible for changes in the mechanical properties.Finally,after 18 years in service,the oxidation induction time of the pipeline was 25.7 min,which was 28.5% higher than the national standard value.There were no potential safety hazards during continuous long-term service.The results of this paper provide reference data and theoretical guidance for the aging process study of buried polyethylene pipelines. 展开更多
关键词 polyethylene Buried pipelines Long-term service Natural aging
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部