TECHNOLOGY OF QUANTITATIVE ANALYSIS ON VIBRATORY STRESS RELIEF BASED ON ULTRASONIC TIME-OF-ARRIVAL METHOD 被引量:4
1
作者 He Wen Ma Zhenyu Wang Xingli 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第3期461-463,共3页
The effect of vibratory stress relief (VSR) is usually evaluated with the indirect method of observing the change of amplitude frequency response characteristics of structures. A new kind of evaluating method of VSR... The effect of vibratory stress relief (VSR) is usually evaluated with the indirect method of observing the change of amplitude frequency response characteristics of structures. A new kind of evaluating method of VSR based on the ultrasonic time-of-arrival method (UTM), which can obtain the residual stress directly through measuring the propagation time of ultrasonic wave in the material, is presented. At first, the principle of the measuring method of residual stress based on UTM is analyzed. Then the measuring system of the method is described, which is in virtue of ultrasonic flaw detector and high-sampling-rate digital oscillograph. And a set of calibration system that contains a piece of standard specimen is also introduced. Experimental results prove the relation between the residual stress and the propagation time of ultrasonic in workpieces. Finally, the measuring and calibration systems are applied in evaluating the effect of VSR. The final test results show that the method is effective. 展开更多
关键词 ultrasonic time-of-arrival method Residual stress Measure Vibratory stress relief
下载PDF
An assessment on the wideband and narrowband methods for ultrasonic blood flow measurements
2
作者 QI Jinyi GAO Shangkai and YANG Fusheng(Dept. of electrical engineering, Tsinghua university Beijing 100084) 《Chinese Journal of Acoustics》 1997年第1期59-70,共12页
A comparison study on the ultrasonic blood flow estimation methods is carried out in this paper. The methods are divided into two classes-narrowband and wideband techniques.The pulsed Doppler systems and the autocorre... A comparison study on the ultrasonic blood flow estimation methods is carried out in this paper. The methods are divided into two classes-narrowband and wideband techniques.The pulsed Doppler systems and the autocorrelation methods are essentially the narrowband estAnators. They give the results with low velocity resolution and probably the aliased spectrum.The wider the frequency band of the signals, the worse the results. Time domain crosscorrelation technique, wideband makimum likelihood estimation and 2D Fourier transform method are three wideband techniques. The high velocity resolution and the ability of anti-aliasing are shown by these wideband estimation strategies. 展开更多
关键词 flow An assessment on the wideband and narrowband methods for ultrasonic blood flow measurements IEEE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部