As a kind of biopolymer,hydrolysates of fish swim bladder,safer than those of land mammals,are widely used in food,cosmetics as well as pharmaceutical and biomedical fields for their biocompatibility,biodegradability,...As a kind of biopolymer,hydrolysates of fish swim bladder,safer than those of land mammals,are widely used in food,cosmetics as well as pharmaceutical and biomedical fields for their biocompatibility,biodegradability,and weak antigenicity.To enhance hydrolysate production,in this paper,the papain and alcalase hydrolysis processes of larimichthys polyactis swim bladder were optimized with orthogonal experiments.With 89.5%hydrolysate yield,the optimal processing conditions for alcalase were solid-liquid ratio of 1:30,enzyme concentration of 0.7%,and extraction time of 6 h.As for papain,under the optimal processing conditions:solid-liquid ratio of 1:20,enzyme concentration of 0.5%,and extraction time of 8 h,the hydrolysate yield was 65.1%.To obtain higher hydrolysate yields,the ultrasonic pretreatments were implemented before the optimal enzyme hydrolysis processes.With ultrasonic waves of 100 W for 50 min,the hydrolysate yields were increased 2.1%(alcalase)and 4.5%(papain),respectively.The Fourier Transform Infrared(FTIR)spectroscopic analysis revealed that the hydrolysates extracted by papain exist in triple-helical forms.The Ultra-Violet(UV)absorption spectra indicated that the aromatic amino acids in the hydrolysates had strong absorptions in the wavelength range of 240 nm–300 nm.The results of this research demonstrate that the alcalase hydrolysates have better solubility in water and the solution is more stable under ambient temperature.However,the hydrolysates extracted by papain have a gel property and are insoluble in weak acid at room temperature,which is more suitable for applications in feedstock of biomedical.展开更多
For building a biosensor, at least two enzyme sources can be employed. The pure enzyme has features with better selectivity and low stability. Crude extract presents better stability and wrong selectivity. Thus, one i...For building a biosensor, at least two enzyme sources can be employed. The pure enzyme has features with better selectivity and low stability. Crude extract presents better stability and wrong selectivity. Thus, one intermediate condition can be feasible joining both benefits of crude extract and pure enzymes. For that result, several procedures of extraction and semi purification of polyphenol oxidase (PPO) enzyme from banana (Musa sp.) were studied. The results showed that cleaned enzymatic extracts presented higher specific activities than crude extracts (2.8 up to 5.3 fold), despite the total protein concentration diminishing from 27% up to 72%, indicating that polyphenol oxidase (PPO) enzyme was preserved in them. The biosensors with 125 AU mL-1 containing cleaned enzymatic extracts performed better by grinding or grinding plus sonication for 30 s. They were linear over the ranges of 5.9 × 10-6 mol·L-1 to 1.4 × 10-3 mol·L-1 and 7.9 × 10-8 mol·L-1 to 4.0 × 10-3 mol·L-1, respectively. The limit of Detection (LOD) was 5.9 × 10-6 mol·L-1 and 7.9 × 10-8 mol·L-1, respectively. The LOD obtained is adequate to adrenaline determination on blood and medicinal samples, and were applied in medicinal samples with satisfactory results.展开更多
基金This research was funded by the Fundamental Research Funds for the Central Universities,Grant No.2572018AB10the Fundamental Research Funds for the Central Universities,Grant No.2572019BB07.
文摘As a kind of biopolymer,hydrolysates of fish swim bladder,safer than those of land mammals,are widely used in food,cosmetics as well as pharmaceutical and biomedical fields for their biocompatibility,biodegradability,and weak antigenicity.To enhance hydrolysate production,in this paper,the papain and alcalase hydrolysis processes of larimichthys polyactis swim bladder were optimized with orthogonal experiments.With 89.5%hydrolysate yield,the optimal processing conditions for alcalase were solid-liquid ratio of 1:30,enzyme concentration of 0.7%,and extraction time of 6 h.As for papain,under the optimal processing conditions:solid-liquid ratio of 1:20,enzyme concentration of 0.5%,and extraction time of 8 h,the hydrolysate yield was 65.1%.To obtain higher hydrolysate yields,the ultrasonic pretreatments were implemented before the optimal enzyme hydrolysis processes.With ultrasonic waves of 100 W for 50 min,the hydrolysate yields were increased 2.1%(alcalase)and 4.5%(papain),respectively.The Fourier Transform Infrared(FTIR)spectroscopic analysis revealed that the hydrolysates extracted by papain exist in triple-helical forms.The Ultra-Violet(UV)absorption spectra indicated that the aromatic amino acids in the hydrolysates had strong absorptions in the wavelength range of 240 nm–300 nm.The results of this research demonstrate that the alcalase hydrolysates have better solubility in water and the solution is more stable under ambient temperature.However,the hydrolysates extracted by papain have a gel property and are insoluble in weak acid at room temperature,which is more suitable for applications in feedstock of biomedical.
文摘For building a biosensor, at least two enzyme sources can be employed. The pure enzyme has features with better selectivity and low stability. Crude extract presents better stability and wrong selectivity. Thus, one intermediate condition can be feasible joining both benefits of crude extract and pure enzymes. For that result, several procedures of extraction and semi purification of polyphenol oxidase (PPO) enzyme from banana (Musa sp.) were studied. The results showed that cleaned enzymatic extracts presented higher specific activities than crude extracts (2.8 up to 5.3 fold), despite the total protein concentration diminishing from 27% up to 72%, indicating that polyphenol oxidase (PPO) enzyme was preserved in them. The biosensors with 125 AU mL-1 containing cleaned enzymatic extracts performed better by grinding or grinding plus sonication for 30 s. They were linear over the ranges of 5.9 × 10-6 mol·L-1 to 1.4 × 10-3 mol·L-1 and 7.9 × 10-8 mol·L-1 to 4.0 × 10-3 mol·L-1, respectively. The limit of Detection (LOD) was 5.9 × 10-6 mol·L-1 and 7.9 × 10-8 mol·L-1, respectively. The LOD obtained is adequate to adrenaline determination on blood and medicinal samples, and were applied in medicinal samples with satisfactory results.