Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patien...Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patients aged 22-79 years were enrolled into the present study. Thirty-eight (55.1%) men with ED who did not respond to four attempts of treatment with 100 mg sildenafil after re-education were classified as sildenafil non-responders. A com- bination of three vasodilator drugs, 1.25 mg papaverine, 0.4 mg phentolamine and 5 ug prostaglandin E1, was given by intracavernous injection before penile Doppler ultrasonography was carried out. The erectile response to intracavernous injection and vascular parameters including peak systolic velocity (PSV), resistance index (RI), end diastolic velocity (EDV) and cavernosa artery diameter (CD) were measured and the results between sildenafil nonresponders and responders were compared. Results: No statistical difference in vascular parameters measured by Doppler ultrasonography studies between non-responders and responders was noted. Sildenafil non-responders had a poorer penile rigidity response to intracavernous injection than responders (P 〈 0.05). Among patients with adequate PSV (〉 30 cm/s) and abnormal EDV (〉 5 cm/s), individuals in the non-responder group had fewer positive responses to intracavernous vasodilator injection than in the responder group (35.3% vs. 72.2%, P 〈 0.05). Advanced age and comorbidity with diabetes mellitus were significantly associated with sildenafil non-response (P 〈 0.05). Conclusion: Sildenafil non-responders were characterized by a poorer penile rigidity response to intracavernous injection and had an associated impaired veno-occlusive mechanism. Advanced age and comorbidity with diabetes mellitus were two common factors associated with non-response.展开更多
AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallb...AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.展开更多
Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagno...Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagnosis rate for prostate cancer. Methods: 31 cases of hypoechoic hypertrophic lesions and 18 cases of hypoechoic cancer lesions in the hypertrophic prostate inner glands were observed by transrectal ultrasonography and comparatively analyze the shape, edge and the systolic peak velocity (Vs) , resistance index (RI) and pulsatility index (PI) of the lesions. Results: In contrast with hypertrophic group, the cancer group presented irregular shape and unclear edge, and obviously higher Vs, RI and PI. Conclusion: The sonographic appearance and Vs. RI. PI have important value in distinguishing hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands.展开更多
<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. &l...<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. <strong>Methods: </strong>48 patients with diabetic lower extremity vascular disease admitted in our hos-pital from September 2018 to September 2019 were included in the study and divided into the observation group, and another 48 patients with the same period of health examination in our hospital were included in the study and divided into the control group. Both groups used color Doppler ultrasound to detect the blood flow of lower extremity vessels. The incidence of blood flow, vascular diameter and stenosis, occlusion and arteriosclerosis of the lower extremity were observed. <strong>Results:</strong> The blood flow and vascular di-ameter of the lower extremity in the observation group were significantly lower than those in the control group (p < 0.05). The incidence of vascular stenosis, vascular occlusion, thrombus, intimal thickening and plaque in the observation group was 85.42%, 22.92%, 10.42% and 93.75% respectively, which was significantly higher than that in the control group was 10.42%, 0.00%, 0.00% and 14.58% (p < 0.05). The incidence of lower extremity vascular lesions in the observation group was significantly higher than that in the control group (p < 0.05). <strong>Conclusion:</strong> Color Doppler ultrasound is of high diagnostic value in the diagnosis of diabetic lower extremity vascular diseases, and can be used to determine the blood flow of the lower extremity and the inner diameter of popliteal artery, thigh artery, dorsalis pedis artery and so on. At the same time, it can also clearly show the specific situation of vascular occlusion, arteriosclerosis and thrombosis, which is of great signif-icance for the prevention and diagnosis of lower extremity vascular lesions, and can provide the basis for the treatment of lower extremity vascular lesions. </div>展开更多
Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results o...Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results of 69 cases of mammary carcinoma proved by surgical pathology and 22 cases of NLM before surgery by multicolor Doppler ultra-sonography. Results: The detection rates of mammary carcinoma and NLM focus by ultrasonic examining were 100%. The shape, envelope, foul line, blood stream between sound and image of two diseases were similar. Of the two diseases, the representation with slight calcification in lump, lower echo in low echo, bloodstream distribution and resistance were different. Conclusion: By analyzing the sound and image representation of mammary lump, we find color Doppler ultrasonography has significant value in identifying and diagnosing mammary carcinoma and non-lactation mastitis lump.展开更多
OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation...OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation were examined by using color Doppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepatic parenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-average blood flow velocity (TAV), resistance index (RI) and diameter of the bile duct. RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17 patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitude single-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepatic arterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepatic artery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosis in the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the 41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of 20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worsening gradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15 patients (75%) and others in 3 patients (15%). CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantation and postoperative complications.展开更多
Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenc...Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenced in its development by several factors, including environment (dietary iodine intake, stress, drugs and infections). The disease is characterized by one or more changes: hyperthyroidism, goiter, ophthalmopathy, skin changes and pretibial myxedema, around 5% less common, and other symptoms 90% to 95%. One of the most relevant clinical practice aspects in Graves’ disease patients management is to distinguish Graves’ disease in initial phase, from other types of destructive thyrotoxicosis, in addition to evaluate therapeutic methods and efficient follow up, as well as predict early recurrence or remission of disease. Scintigraphy with pertechnetate (99 mTc) and TSH levels dosage are considered the choice for this purpose. However, they present some technical difficulties, as they are not widely available and have contraindications. In this scenario, thyroid color-flow doppler ultrasonography (US Doppler) presents a viable alternative, as a widely available, low cost, non-invasive and radiation free method, providing initial diagnosis and patients with Graves’ disease follow up. In adittion, this method is used in differential diagnosis with other causes of thyrotoxicosis in the early stage.展开更多
Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions...Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11); in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT.展开更多
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T...AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG.展开更多
BACKGROUND Irritable bowel syndrome(IBS)is one of the most frequently referred conditions to the gastrointestinal outpatient clinic.The pathophysiology of IBS has not been determined with certainty.Visceral hypersensi...BACKGROUND Irritable bowel syndrome(IBS)is one of the most frequently referred conditions to the gastrointestinal outpatient clinic.The pathophysiology of IBS has not been determined with certainty.Visceral hypersensitivity is indicated as one of the pathophysiologies.The sympathetic nervous system is primarily in charge of controlling the arteries,and its effect is vasospasm in the medium and large arteries,resulting in decreased blood flow.AIM To demonstrate,using Doppler evaluation of the brachial artery,that sympathetic activity impairs vasomotor performance due to autonomic neuropathy,which we believe is associated with IBS.METHODS There were 58 participants in the study.The control group consisted of 29 healthy patients,while the remaining 29 patients had been diagnosed with IBS.Patients who met the Rome IV criteria and had IBS were included in the study.People with known polyneuropathy or non-IBS chronic conditions that can progress were excluded from the trial,as were those with essential hypertension,diabetes mellitus,cardiovascular disease,or peripheral arterial disease,and patients diagnosed with anxiety or depression.Those with moderate to severe carpal tunnel syndrome or a median nerve lesion due to trauma were also excluded from the trial.A Doppler probe was used to measure the baseline diameter and flow rates of the brachial artery from 2 cm superior to the antecubital fossa.The Doppler probe remained stationary throughout the experiment,allowing for continuous measurements.Then,to activate the sympathetic fibers,an electrical stimulus for 5 s with an intensity of 10 mA and a frequency of 1 Hz was applied to the median nerve at the wrist level via the bipolar stimulus electrode.The artery diameter and flow rates were measured again immediately following the fifth stimulus.RESULTS In healthy persons with no history of chronic illness,there was a statistically significant decrease in flow rate after stimulation(P<0.001).In addition,stimulation resulted in a statistically significant reduction in the diameter of the brachial artery(P<0.001).Patients diagnosed with IBS had statistically significant vasodilation and an increase in flow rate.CONCLUSION Sympathetic stimulation causes a reduction in vascular diameter and blood flow,whereas it has the reverse effect on IBS patients.In investigating the involvement of autonomic neuropathy in the development of IBS,significant changes in brachial artery Doppler parameters were observed before and after stimulation of the median nerve with low-current sensory stimulation.This method is thought to be more user-friendly and comfortable than other methods described in the literature.展开更多
Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI...Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility.展开更多
AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN) treatment. METHODS: The subjects in this st...AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN) treatment. METHODS: The subjects in this study were 14 patients (13 men and l woman) with CHC who received IFN treatment. Portal blood flow velocity was measured in the vessels at the porta hepatis at four time points: before IFN administration (pre-IFN), 2 wk after the start of administration (wk 2), 24 wk after the start of administration (wk 24, i.e., the end of IFN administration), and 24 wk after the end of administration (wk 48). RESULTS: The patients with CHC in whom IFN treatment resulted in complete elimination or effective elimination of viruses showed a significant increase in portal blood flow velocity at the end of IFN treatment compared with that before IFN treatment. In contrast, when IFN was ineffective, no significant increase in portal blood flow velocity was observed at wk 24 or 48 compared with the pre-IFN value. In addition, the patients with CHC in whom IFN was ineffective showed significantly lower portal blood flow velocity values than control subjects at all measurement time points. CONCLUSION: Pulse wave Doppler ultrasonography is a noninvasive and easily performed method for evaluating the effects of IFN treatment in patients with CHC. This technique is useful for measuring portal blood flow velocity before and 24 wk after IFN administration in order to evaluate the changes over time, thus assessing the effectiveness of IFN treatment.展开更多
A cross sectional transvaginal color Doppler study of the uteroplacental circulation was performed on 105 pregnant women with normal intrauterine pregnancy. Gestational age was ranged from 4 to 12 weeks. The blood fl...A cross sectional transvaginal color Doppler study of the uteroplacental circulation was performed on 105 pregnant women with normal intrauterine pregnancy. Gestational age was ranged from 4 to 12 weeks. The blood flow velocity waveforms were obtained from four separate parts of the uteroplacental circulation: uterine, arcuate, radial, and spiral arteries. The resistance index (RI) and peak systolic velocity (PSV) were analyzed. The RI significantly decreased and PSV increased with advancing gestation in uterine artery and its branches (P<0 05). The RI gradully decreased from uterine artery through arcuate, radial to spiral arteries (P<0 05). At the same time, the PSV decreased from uterine artery then arcuate to radial artery, but PSV in spiral arteries were higher than that in radial artery (P<0 05). The results showed that transvaginal color Dopper ultrasonography was a simple, reliable method to assess the uteroplacental circulation in the early pregnancy; the detection of PSV was useful parameter for better understanding of physiological and pathophysiological hemodynamic changes as well as RI.展开更多
AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic ...AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (X^2 = 0.250, 0.677, P 〉 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation.展开更多
Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer p...Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer patients were observed in this study. Changes of color Doppler energy (CDE) images before and after TEPS of local points nearby the liver were recorded by using color Doppler ultrasound diagnostic apparatus (ACUSON 128XP/10C). Sum of color pixel area (SCPA), average of color value (ACV) and SCPA×ACV (integral) of the hepatic flow images were analyzed by an image processing system, single blind method and paired t-test. Programmed TEPS (0.5- 150 Hz / 2 000 Hz , 10- 25 V ) was applied to the right Qimen (期门 LR 14)-Jingmen (京门 GB 25), Fuai (腹哀 SP 16)-Ganshu (肝俞 BL 18) respectively for 15 min. Results: Compared with basic values of pretreatment, SCPA, ACV and SCPA×ACV increased significantly (t=2.71, P<0.02; t=3.42, P<0.01; and t=8.15, P<0.001) after TEPS, meaning improvement of hepatic blood flow supply. Conclusion: TEPS of acupoints near the liver can improve hepatic blood flow and hepatic parenchymal microcirculation in patients with fatty liver.展开更多
Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from ...Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from 11 healthy adults were used展开更多
AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patien...AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding.展开更多
Non-invasive Doppler ultrasonographic study of cerebral arteries [transcranial Doppler(TCD)] has been extensively applied on both outpatient and inpatient settings. It is performed placing a low-frequency(≤ 2 MHz) tr...Non-invasive Doppler ultrasonographic study of cerebral arteries [transcranial Doppler(TCD)] has been extensively applied on both outpatient and inpatient settings. It is performed placing a low-frequency(≤ 2 MHz) transducer on the scalp of the patient over specific acoustic windows, in order to visualize the intracranial arterial vessels and to evaluate the cerebral blood flow velocity and its alteration in many different conditions. Nowadays the most widespread indication for TCD in outpatient setting is the research of right to left shunting, responsable of so called "paradoxical embolism", most often due to patency of foramen ovale which is responsable of the majority of cryptogenic strokes occuring in patients younger than 55 years old. TCD also allows to classify the grade of severity of such shunts using the so called "microembolic signal grading score". In addition TCD has found many useful applications in neurocritical care practice. It is useful on both adults and children for day-to-day bedside assessment of critical conditions including vasospasm in subarachnoidal haemorrhage(caused by aneurysm rupture or traumatic injury), traumatic brain injury, brain stem death. It is used also to evaluate cerebral hemodynamic changes after stroke. It also allows to investigate cerebral pressure autoregulation and for the clinical evaluation of cerebral autoregulatory reserve.展开更多
AIM: To study the postoperative complications in patients with preoperative portal vein thrombosis (PVT) undergoing liver transplantation (LT) and to evaluate the complications with Doppler ultrasonography.METHOD...AIM: To study the postoperative complications in patients with preoperative portal vein thrombosis (PVT) undergoing liver transplantation (LT) and to evaluate the complications with Doppler ultrasonography.METHODS: Retrospective studies were performed on 284 patients undergoing LT (286 LT) with respect to pre- and postoperative clinical data and Doppler ultrasonography. According to the presence and grade of preoperative PVT, 286 LTs were divided into three groups: complete PVT (c-PVT), partial PVT (p-PVT) and non-PVT, with 22, 30 and 234 LTs, respectively. Analyses were carried out to compare the incidence of early postoperative complications.RESULTS: PVT, inferior vena cava (IVC) thrombosis, hepatic artery thrombosis (HAT) and biliary complications were found postoperatively. All complications were detected by routine Doppler ultrasonography and diagnoses made by ultrasound were confirmed by clinical data or/and other imaging studies. Nine out of 286 LTs had postoperative PVT. The incidence of the c-Pv-r group was 22.7%, which was higher than that of the p-Pv-r group (3.3%, P 〈 0.05) and non- PVT group (1.3%, P 〈 0.005). No difference was found between the p-PVT and non-PVT groups (P 〉 0.25). Of the 9 cases with postoperative PVT, recanalizations were achieved in 7 cases after anticoagulation under the guidance of ultrasound, 1 case received portal vein thrombectomy and 1 case died of acute injection. Ten LTs had postoperative 1VC thrombosis. The c-PVT group had a higher incidence of IVC thrombosis than the non- PVT group (9.1% vs 2.6%, P 〈 0.05); no significant difference was found between either the c-PV-T and p-PVT groups (9.1% vs 6.7%, P 〉 0.5) or between the p-PVT and non-PVT groups (P 〉 0.25). Nine cases with IVC thrombosis were cured by anticoagulation under the guidance of ultrasound, and 1 case gained natural cure without any medical treatment after 2 mo. HAT was found in 2 non-PVT cases, giving a rate of 0.7% among 286 LTs. Biliary complications were seen in 12 LTs. The incidence of biliary complications in the c-PVT, p-PVT and non-PVT groups was 9.1%, 3.3% and 4.3%, respectively (P 〉 0.25 for all), among which 2 stenosis led retransplantations and others were controlled by relative therapy.CONCLUSION: C-PVT patients tend to have a higher incidence of PVT and IVC thrombosis than non- PVT patients after LT. The incidence of postoperative complications in p-PVT patients does not differ from that of non-PVT patients, A relatively low incidence of HAT was seen in our study, Doppler ultrasonography is a convenient and efficient method for detecting posttransplant complications and plays an important role in guiding treatment.展开更多
The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tu...The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms.展开更多
文摘Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patients aged 22-79 years were enrolled into the present study. Thirty-eight (55.1%) men with ED who did not respond to four attempts of treatment with 100 mg sildenafil after re-education were classified as sildenafil non-responders. A com- bination of three vasodilator drugs, 1.25 mg papaverine, 0.4 mg phentolamine and 5 ug prostaglandin E1, was given by intracavernous injection before penile Doppler ultrasonography was carried out. The erectile response to intracavernous injection and vascular parameters including peak systolic velocity (PSV), resistance index (RI), end diastolic velocity (EDV) and cavernosa artery diameter (CD) were measured and the results between sildenafil nonresponders and responders were compared. Results: No statistical difference in vascular parameters measured by Doppler ultrasonography studies between non-responders and responders was noted. Sildenafil non-responders had a poorer penile rigidity response to intracavernous injection than responders (P 〈 0.05). Among patients with adequate PSV (〉 30 cm/s) and abnormal EDV (〉 5 cm/s), individuals in the non-responder group had fewer positive responses to intracavernous vasodilator injection than in the responder group (35.3% vs. 72.2%, P 〈 0.05). Advanced age and comorbidity with diabetes mellitus were significantly associated with sildenafil non-response (P 〈 0.05). Conclusion: Sildenafil non-responders were characterized by a poorer penile rigidity response to intracavernous injection and had an associated impaired veno-occlusive mechanism. Advanced age and comorbidity with diabetes mellitus were two common factors associated with non-response.
文摘AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.
文摘Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagnosis rate for prostate cancer. Methods: 31 cases of hypoechoic hypertrophic lesions and 18 cases of hypoechoic cancer lesions in the hypertrophic prostate inner glands were observed by transrectal ultrasonography and comparatively analyze the shape, edge and the systolic peak velocity (Vs) , resistance index (RI) and pulsatility index (PI) of the lesions. Results: In contrast with hypertrophic group, the cancer group presented irregular shape and unclear edge, and obviously higher Vs, RI and PI. Conclusion: The sonographic appearance and Vs. RI. PI have important value in distinguishing hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands.
文摘<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. <strong>Methods: </strong>48 patients with diabetic lower extremity vascular disease admitted in our hos-pital from September 2018 to September 2019 were included in the study and divided into the observation group, and another 48 patients with the same period of health examination in our hospital were included in the study and divided into the control group. Both groups used color Doppler ultrasound to detect the blood flow of lower extremity vessels. The incidence of blood flow, vascular diameter and stenosis, occlusion and arteriosclerosis of the lower extremity were observed. <strong>Results:</strong> The blood flow and vascular di-ameter of the lower extremity in the observation group were significantly lower than those in the control group (p < 0.05). The incidence of vascular stenosis, vascular occlusion, thrombus, intimal thickening and plaque in the observation group was 85.42%, 22.92%, 10.42% and 93.75% respectively, which was significantly higher than that in the control group was 10.42%, 0.00%, 0.00% and 14.58% (p < 0.05). The incidence of lower extremity vascular lesions in the observation group was significantly higher than that in the control group (p < 0.05). <strong>Conclusion:</strong> Color Doppler ultrasound is of high diagnostic value in the diagnosis of diabetic lower extremity vascular diseases, and can be used to determine the blood flow of the lower extremity and the inner diameter of popliteal artery, thigh artery, dorsalis pedis artery and so on. At the same time, it can also clearly show the specific situation of vascular occlusion, arteriosclerosis and thrombosis, which is of great signif-icance for the prevention and diagnosis of lower extremity vascular lesions, and can provide the basis for the treatment of lower extremity vascular lesions. </div>
文摘Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results of 69 cases of mammary carcinoma proved by surgical pathology and 22 cases of NLM before surgery by multicolor Doppler ultra-sonography. Results: The detection rates of mammary carcinoma and NLM focus by ultrasonic examining were 100%. The shape, envelope, foul line, blood stream between sound and image of two diseases were similar. Of the two diseases, the representation with slight calcification in lump, lower echo in low echo, bloodstream distribution and resistance were different. Conclusion: By analyzing the sound and image representation of mammary lump, we find color Doppler ultrasonography has significant value in identifying and diagnosing mammary carcinoma and non-lactation mastitis lump.
文摘OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation were examined by using color Doppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepatic parenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-average blood flow velocity (TAV), resistance index (RI) and diameter of the bile duct. RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17 patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitude single-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepatic arterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepatic artery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosis in the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the 41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of 20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worsening gradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15 patients (75%) and others in 3 patients (15%). CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantation and postoperative complications.
文摘Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenced in its development by several factors, including environment (dietary iodine intake, stress, drugs and infections). The disease is characterized by one or more changes: hyperthyroidism, goiter, ophthalmopathy, skin changes and pretibial myxedema, around 5% less common, and other symptoms 90% to 95%. One of the most relevant clinical practice aspects in Graves’ disease patients management is to distinguish Graves’ disease in initial phase, from other types of destructive thyrotoxicosis, in addition to evaluate therapeutic methods and efficient follow up, as well as predict early recurrence or remission of disease. Scintigraphy with pertechnetate (99 mTc) and TSH levels dosage are considered the choice for this purpose. However, they present some technical difficulties, as they are not widely available and have contraindications. In this scenario, thyroid color-flow doppler ultrasonography (US Doppler) presents a viable alternative, as a widely available, low cost, non-invasive and radiation free method, providing initial diagnosis and patients with Graves’ disease follow up. In adittion, this method is used in differential diagnosis with other causes of thyrotoxicosis in the early stage.
文摘Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11); in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT.
文摘AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG.
文摘BACKGROUND Irritable bowel syndrome(IBS)is one of the most frequently referred conditions to the gastrointestinal outpatient clinic.The pathophysiology of IBS has not been determined with certainty.Visceral hypersensitivity is indicated as one of the pathophysiologies.The sympathetic nervous system is primarily in charge of controlling the arteries,and its effect is vasospasm in the medium and large arteries,resulting in decreased blood flow.AIM To demonstrate,using Doppler evaluation of the brachial artery,that sympathetic activity impairs vasomotor performance due to autonomic neuropathy,which we believe is associated with IBS.METHODS There were 58 participants in the study.The control group consisted of 29 healthy patients,while the remaining 29 patients had been diagnosed with IBS.Patients who met the Rome IV criteria and had IBS were included in the study.People with known polyneuropathy or non-IBS chronic conditions that can progress were excluded from the trial,as were those with essential hypertension,diabetes mellitus,cardiovascular disease,or peripheral arterial disease,and patients diagnosed with anxiety or depression.Those with moderate to severe carpal tunnel syndrome or a median nerve lesion due to trauma were also excluded from the trial.A Doppler probe was used to measure the baseline diameter and flow rates of the brachial artery from 2 cm superior to the antecubital fossa.The Doppler probe remained stationary throughout the experiment,allowing for continuous measurements.Then,to activate the sympathetic fibers,an electrical stimulus for 5 s with an intensity of 10 mA and a frequency of 1 Hz was applied to the median nerve at the wrist level via the bipolar stimulus electrode.The artery diameter and flow rates were measured again immediately following the fifth stimulus.RESULTS In healthy persons with no history of chronic illness,there was a statistically significant decrease in flow rate after stimulation(P<0.001).In addition,stimulation resulted in a statistically significant reduction in the diameter of the brachial artery(P<0.001).Patients diagnosed with IBS had statistically significant vasodilation and an increase in flow rate.CONCLUSION Sympathetic stimulation causes a reduction in vascular diameter and blood flow,whereas it has the reverse effect on IBS patients.In investigating the involvement of autonomic neuropathy in the development of IBS,significant changes in brachial artery Doppler parameters were observed before and after stimulation of the median nerve with low-current sensory stimulation.This method is thought to be more user-friendly and comfortable than other methods described in the literature.
文摘Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility.
文摘AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN) treatment. METHODS: The subjects in this study were 14 patients (13 men and l woman) with CHC who received IFN treatment. Portal blood flow velocity was measured in the vessels at the porta hepatis at four time points: before IFN administration (pre-IFN), 2 wk after the start of administration (wk 2), 24 wk after the start of administration (wk 24, i.e., the end of IFN administration), and 24 wk after the end of administration (wk 48). RESULTS: The patients with CHC in whom IFN treatment resulted in complete elimination or effective elimination of viruses showed a significant increase in portal blood flow velocity at the end of IFN treatment compared with that before IFN treatment. In contrast, when IFN was ineffective, no significant increase in portal blood flow velocity was observed at wk 24 or 48 compared with the pre-IFN value. In addition, the patients with CHC in whom IFN was ineffective showed significantly lower portal blood flow velocity values than control subjects at all measurement time points. CONCLUSION: Pulse wave Doppler ultrasonography is a noninvasive and easily performed method for evaluating the effects of IFN treatment in patients with CHC. This technique is useful for measuring portal blood flow velocity before and 24 wk after IFN administration in order to evaluate the changes over time, thus assessing the effectiveness of IFN treatment.
文摘A cross sectional transvaginal color Doppler study of the uteroplacental circulation was performed on 105 pregnant women with normal intrauterine pregnancy. Gestational age was ranged from 4 to 12 weeks. The blood flow velocity waveforms were obtained from four separate parts of the uteroplacental circulation: uterine, arcuate, radial, and spiral arteries. The resistance index (RI) and peak systolic velocity (PSV) were analyzed. The RI significantly decreased and PSV increased with advancing gestation in uterine artery and its branches (P<0 05). The RI gradully decreased from uterine artery through arcuate, radial to spiral arteries (P<0 05). At the same time, the PSV decreased from uterine artery then arcuate to radial artery, but PSV in spiral arteries were higher than that in radial artery (P<0 05). The results showed that transvaginal color Dopper ultrasonography was a simple, reliable method to assess the uteroplacental circulation in the early pregnancy; the detection of PSV was useful parameter for better understanding of physiological and pathophysiological hemodynamic changes as well as RI.
基金Supported by A Grant from the Department of Science & Technology of Hebei Province, No. 052761659
文摘AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (X^2 = 0.250, 0.677, P 〉 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation.
基金This study was subsidized by Zhuhai Bureau of Science and Technology , Guangdong Province (2000-02-08)
文摘Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer patients were observed in this study. Changes of color Doppler energy (CDE) images before and after TEPS of local points nearby the liver were recorded by using color Doppler ultrasound diagnostic apparatus (ACUSON 128XP/10C). Sum of color pixel area (SCPA), average of color value (ACV) and SCPA×ACV (integral) of the hepatic flow images were analyzed by an image processing system, single blind method and paired t-test. Programmed TEPS (0.5- 150 Hz / 2 000 Hz , 10- 25 V ) was applied to the right Qimen (期门 LR 14)-Jingmen (京门 GB 25), Fuai (腹哀 SP 16)-Ganshu (肝俞 BL 18) respectively for 15 min. Results: Compared with basic values of pretreatment, SCPA, ACV and SCPA×ACV increased significantly (t=2.71, P<0.02; t=3.42, P<0.01; and t=8.15, P<0.001) after TEPS, meaning improvement of hepatic blood flow supply. Conclusion: TEPS of acupoints near the liver can improve hepatic blood flow and hepatic parenchymal microcirculation in patients with fatty liver.
文摘Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from 11 healthy adults were used
基金Supported by the Natural Science Foundation of Shanghai, No. 034119921
文摘AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding.
文摘Non-invasive Doppler ultrasonographic study of cerebral arteries [transcranial Doppler(TCD)] has been extensively applied on both outpatient and inpatient settings. It is performed placing a low-frequency(≤ 2 MHz) transducer on the scalp of the patient over specific acoustic windows, in order to visualize the intracranial arterial vessels and to evaluate the cerebral blood flow velocity and its alteration in many different conditions. Nowadays the most widespread indication for TCD in outpatient setting is the research of right to left shunting, responsable of so called "paradoxical embolism", most often due to patency of foramen ovale which is responsable of the majority of cryptogenic strokes occuring in patients younger than 55 years old. TCD also allows to classify the grade of severity of such shunts using the so called "microembolic signal grading score". In addition TCD has found many useful applications in neurocritical care practice. It is useful on both adults and children for day-to-day bedside assessment of critical conditions including vasospasm in subarachnoidal haemorrhage(caused by aneurysm rupture or traumatic injury), traumatic brain injury, brain stem death. It is used also to evaluate cerebral hemodynamic changes after stroke. It also allows to investigate cerebral pressure autoregulation and for the clinical evaluation of cerebral autoregulatory reserve.
文摘AIM: To study the postoperative complications in patients with preoperative portal vein thrombosis (PVT) undergoing liver transplantation (LT) and to evaluate the complications with Doppler ultrasonography.METHODS: Retrospective studies were performed on 284 patients undergoing LT (286 LT) with respect to pre- and postoperative clinical data and Doppler ultrasonography. According to the presence and grade of preoperative PVT, 286 LTs were divided into three groups: complete PVT (c-PVT), partial PVT (p-PVT) and non-PVT, with 22, 30 and 234 LTs, respectively. Analyses were carried out to compare the incidence of early postoperative complications.RESULTS: PVT, inferior vena cava (IVC) thrombosis, hepatic artery thrombosis (HAT) and biliary complications were found postoperatively. All complications were detected by routine Doppler ultrasonography and diagnoses made by ultrasound were confirmed by clinical data or/and other imaging studies. Nine out of 286 LTs had postoperative PVT. The incidence of the c-Pv-r group was 22.7%, which was higher than that of the p-Pv-r group (3.3%, P 〈 0.05) and non- PVT group (1.3%, P 〈 0.005). No difference was found between the p-PVT and non-PVT groups (P 〉 0.25). Of the 9 cases with postoperative PVT, recanalizations were achieved in 7 cases after anticoagulation under the guidance of ultrasound, 1 case received portal vein thrombectomy and 1 case died of acute injection. Ten LTs had postoperative 1VC thrombosis. The c-PVT group had a higher incidence of IVC thrombosis than the non- PVT group (9.1% vs 2.6%, P 〈 0.05); no significant difference was found between either the c-PV-T and p-PVT groups (9.1% vs 6.7%, P 〉 0.5) or between the p-PVT and non-PVT groups (P 〉 0.25). Nine cases with IVC thrombosis were cured by anticoagulation under the guidance of ultrasound, and 1 case gained natural cure without any medical treatment after 2 mo. HAT was found in 2 non-PVT cases, giving a rate of 0.7% among 286 LTs. Biliary complications were seen in 12 LTs. The incidence of biliary complications in the c-PVT, p-PVT and non-PVT groups was 9.1%, 3.3% and 4.3%, respectively (P 〉 0.25 for all), among which 2 stenosis led retransplantations and others were controlled by relative therapy.CONCLUSION: C-PVT patients tend to have a higher incidence of PVT and IVC thrombosis than non- PVT patients after LT. The incidence of postoperative complications in p-PVT patients does not differ from that of non-PVT patients, A relatively low incidence of HAT was seen in our study, Doppler ultrasonography is a convenient and efficient method for detecting posttransplant complications and plays an important role in guiding treatment.
文摘The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms.