期刊文献+
共找到60,805篇文章
< 1 2 250 >
每页显示 20 50 100
Magnetic resonance-guided focused ultrasound for essential tremor:a prospective,single center,single-arm study
1
作者 Rui Zong Xuemei Li +10 位作者 Chunyu Yin Jianfeng He Dekang Zhang Xiangbing Bian Lichao Huang Jiayou Zhou Zhipei Ling Lin Ma Xin Lou Longsheng Pan Xinguang Yu 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第9期2075-2080,共6页
The safety and effectiveness of magnetic resonance-guided focused ultrasound thalamotomy has been broadly established and validated for the treatment of essential tremor.In 2018,the first magnetic resonance-guided foc... The safety and effectiveness of magnetic resonance-guided focused ultrasound thalamotomy has been broadly established and validated for the treatment of essential tremor.In 2018,the first magnetic resonance-guided focused ultrasound system in Chinese mainland was installed at the First Medical Center of the PLA General Hospital.This prospective,single center,open-label,single-arm study was part of a worldwide prospective multicenter clinical trial(ClinicalTrials.gov Identifier:NCT03253991)conducted to confirm the safety and efficacy of magnetic resonance-guided focused ultrasound for treating essential tremor in the local population.From 2019 to 2020,10 patients with medication refractory essential tremor were recruited into this open-label,single arm study.The treatment efficacy was determined using the Clinical Rating Scale for Tremor.Safety was evaluated according to the incidence and severity of adverse events.All of the subjects underwent a unilateral thalamotomy targeting the ventral intermediate nucleus.At the baseline assessment,the estimated marginal mean of the Clinical Rating Scale for Tremor total score was 58.3±3.6,and this improved after treatment to 23.1±6.4 at a 12-month follow-up assessment.A total of 50 adverse events were recorded,and 2 were defined as serious.The most common intraoperative adverse events were nausea and headache.The most frequent postoperative adverse events were paresthesia and equilibrium disorder.Most of the adverse events were mild and usually disappeared within a few days.Our findings suggest that magnetic resonance-guided focused ultrasound for the treatment of essential tremor is effective,with a good safety profile,for patients in Chinese mainland. 展开更多
关键词 efficacy essential tremor magnetic resonance-guided focused ultrasound(MRgFus) movement disorder safety stereotactic therapy THALAMOTOMY ventral intermediate nucleus
下载PDF
Evaluation of hand infections in the emergency department using point-of-care ultrasound
2
作者 David Ahmad Haidar David Mintz +2 位作者 Brandon M Wubben Omar Rizvi Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期283-288,共6页
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana... BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care. 展开更多
关键词 ultrasound Point-of-care ultrasound CELLULITIS ABSCESS Flexor tenosynovitis
下载PDF
Suppression of low-frequency ultrasound broadband vibration using star-shaped single-phase metamaterials
3
作者 Rui Zhao Jian Zheng +4 位作者 Jin Guo Yunbo Shi Hengzhen Feng Jun Tang Jun Liu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期217-224,共8页
In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation pr... In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment. 展开更多
关键词 Star-shaped metamaterials BROADBAND Vibration attenuation Low-frequency ultrasound vibration Transmission loss
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage
4
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 Endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Percutaneous ultrasound-guided coaxial core needle biopsy for the diagnosis of multiple splenic lesions: A case report
5
作者 Sha-Hong Pu Wu-Yong-Ga Bao +2 位作者 Zhen-Peng Jiang Rui Yang Qiang Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期616-621,共6页
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide... BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue. 展开更多
关键词 SPLEEN Splenic disease ultrasound BIOPSY ultrasound-guided coaxial core needle biopsy Case report
下载PDF
Endoscopic ultrasound-guided lauromacrogol injection for treatment of colorectal cavernous hemangioma:Two case reports
6
作者 Hua-Tuo Zhu Wen-Guo Chen +4 位作者 Jing-Jie Wang Jia-Nan Guo Fen-Ming Zhang Guo-Qiang Xu Hong-Tan Chen 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期966-973,共8页
BACKGROUND Colorectal cavernous hemangioma is a rare vascular malformation resulting in recurrent lower gastrointestinal hemorrhage,and can be misinterpreted as colitis.Surgical resection is currently the mainstay of ... BACKGROUND Colorectal cavernous hemangioma is a rare vascular malformation resulting in recurrent lower gastrointestinal hemorrhage,and can be misinterpreted as colitis.Surgical resection is currently the mainstay of treatment,with an emphasis on sphincter preservation.CASE SUMMARY We present details of two young patients with a history of persistent hematochezia diagnosed with colorectal cavernous hemangioma by endoscopic ultrasound(EUS).Cavernous hemangioma was relieved by several EUS-guided lauromacrogol injections and the patients achieved favorable clinical prognosis.CONCLUSION Multiple sequential EUS-guided injections of lauromacrogol is a safe,effective,cost-efficient,and minimally invasive alternative for colorectal cavernous hemangioma. 展开更多
关键词 Endoscopic ultrasound Lauromacrogol injection Colorectal cavernous hemangioma Case report
下载PDF
Pain Efficacy of a Home-Based Low-Intensity Continuous Ultrasound Stimulator for Knee Arthritis: A Single-Arm, Open-Label, Prospective Clinical Trial
7
作者 Md. Habibur Rahman Yeon-Gyu Jang +8 位作者 Johny Bajgai Subham Sharma Kchorng Vira Abdul-Nasir Sofian Seong Hoon Goh Yundeok Kim Cheol-Su Kim Doo-Sup Kim Kyu-Jae Lee 《Health》 2024年第7期703-716,共14页
1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee o... 1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery. 展开更多
关键词 Knee Osteoarthritis Low-Intensity Continuous ultrasound Stimulator Clinical Trial Visual Analogue Scale Western Ontario and McMaster Universities Osteoarthritis Index
下载PDF
Point-of-care ultrasonography spotlight:Could venous excess ultrasound serve as a shared language for internists and intensivists?
8
作者 Anosh Aslam Khan Hasham Saeed +3 位作者 Ibtehaj Ul Haque Ayman Iqbal Doantrang Du Abhilash Koratala 《World Journal of Critical Care Medicine》 2024年第2期126-136,共11页
Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and in... Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties. 展开更多
关键词 Point-of-care ultrasonography ultrasound Venous excess ultrasound Doppler Congestion Heart failure
下载PDF
Comparison of efficacy of lung ultrasound and chest X-ray in diagnosing pulmonary edema and pleural effusion in ICU patients: A single centre, prospective, observational study
9
作者 Kunal Tewari Sumanth Pelluru +5 位作者 Deepak Mishra Nitin Pahuja Akash Ray Mohapatra Jyotsna Sharma Om Bahadur Thapa Manjot Multani 《Open Journal of Anesthesiology》 2024年第3期41-50,共10页
Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LU... Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LUS) in resource-rich ICUs is still under investigation. The present study compares the utility of LUS to that of CXR in identifying pulmonary edema and pleural effusion in ICU patients. In addition, consolidation and pneumothorax were analyzed as secondary outcome measures. Material and Methods This is a prospective, single centric, observational study. Patients admitted in ICU were examined for lung pathologies, using LUS by a trained intensivist;and CXR done within 4 hours of each other. The final diagnosis was ascertained by an independent senior radiologist, based on the complete medical chart including clinical findings and the results of thoracic CT, if available. The results were compared and analyzed. Results Sensitivity, specificity and diagnostic accuracy of LUS was 95%, 94.4%, 94.67% for pleural effusion;and 98.33%, 97.78%, 98.00% for pulmonary edema respectively. Corresponding values with CXR were 48.33%, 76.67%, 65.33% for pleural effusion;and 36.67%, 82.22% and 64.00% for pulmonary edema respectively. Sensitivity, specificity and diagnostic accuracy of LUS was 91.30%, 96.85%, 96.00% for consolidation;and 100.00%, 79.02%, 80.00% for pneumothorax respectively. Corresponding values with CXR were 60.87%, 81.10%, 78.00% for consolidation;and 71.3%, 97.20%, 96.00% for pneumothorax respectively. Conclusion LUS has better diagnostic accuracy in diagnosis of pleural effusion and pulmonary edema when compared with CXR and is thus recommended as an effective alternative for diagnosis of these conditions in acute care settings. Our study recommends that a thoracic CT scan can be avoided in most of such cases. 展开更多
关键词 Chest X ray (CXR) CONSOLIDATION Pulmonary edema Pleural effusion Lung ultrasound (Lus) PNEUMOTHORAX
下载PDF
Evaluating the Efficacy of Cervical Tactile Ultrasound Technique as a Predictive Tool for Spontaneous Preterm Birth
10
作者 Vladimir Egorov Todd Rosen +4 位作者 Jennifer Hill Meena Khandelwal Victors Kurtenoks Brendan Francy Noune Sarvazyan 《Open Journal of Obstetrics and Gynecology》 2024年第5期832-846,共15页
Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical t... Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods: Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results: CM examination data were analyzed for 127 women at 24<sup>0/7</sup> - 28<sup>6/7</sup> gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group’s 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10<sup>−</sup><sup>4</sup>. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion: These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner. 展开更多
关键词 Cervical Elasticity Spontaneous Preterm Birth Tactile ultrasound Probe
下载PDF
The Value of Ultrasound in the Application of Water Enema in Intussusception
11
作者 Min Li 《Journal of Clinical and Nursing Research》 2024年第5期108-113,共6页
Objective:To introduce high-frequency ultrasound diagnostic technology to cooperate with diagnosis and treatment for patients with intussusception,and to observe its clinical application effect.Methods:The study took ... Objective:To introduce high-frequency ultrasound diagnostic technology to cooperate with diagnosis and treatment for patients with intussusception,and to observe its clinical application effect.Methods:The study took patients with intussusception as the object of observation,with a total of 52 cases participating,all of which were clinically admitted from December 2022 to December 2023.After enrollment,the patients underwent high-frequency ultrasound detection in sequence,recording the ultrasound imaging characteristics,and referring to the results of surgical or leaky saline enema reset to confirm the diagnosis(the gold standard)to assess the diagnostic efficacy of high-frequency ultrasound technology.Results:Comparing the confirmed diagnostic results of surgery or leaking saline enema restoration,the detection rate of high-frequency ultrasound technology was 98.07%(P>0.05).Among the 52 patients treated with hydropneumatic enema restoration with the cooperation of high-frequency ultrasound monitoring,39 patients were successfully reset in the first treatment(75.00%),while 9 patients were successfully reset(17.30%)after multiple treatments(≥2 times);the remaining 4 patients were unsuccessful and then converted to surgical treatment,and all of them were successfully treated and cured.Conclusion:For the diagnosis of intussusception,high-frequency color Doppler ultrasound has the advantages of high accuracy and simple operation,which provides a scientific and accurate reference basis for the clinical diagnosis and treatment of patients. 展开更多
关键词 ultrasound INTusSusCEPTION ENEMA Diagnostic efficiency
下载PDF
Clinical Application of Preliminary Breast Cancer Screening for Dense Breasts Using Real-Time AI-Powered Ultrasound with Deep-Learning Computer Vision
12
作者 Zhenzhong Zhou Xueqin Xie +3 位作者 Zongjin Yang Zhongxiong Feng Xiaoling Zheng Qian Huang 《Journal of Clinical and Nursing Research》 2024年第6期36-47,共12页
Objective:We propose a solution that is backed by cloud computing,combines a series of AI neural networks of computer vision;is capable of detecting,highlighting,and locating breast lesions from a live ultrasound vide... Objective:We propose a solution that is backed by cloud computing,combines a series of AI neural networks of computer vision;is capable of detecting,highlighting,and locating breast lesions from a live ultrasound video feed,provides BI-RADS categorizations;and has reliable sensitivity and specificity.Multiple deep-learning models were trained on more than 300,000 breast ultrasound images to achieve object detection and regions of interest classification.The main objective of this study was to determine whether the performance of our Al-powered solution was comparable to that of ultrasound radiologists.Methods:The noninferiority evaluation was conducted by comparing the examination results of the same screening women between our AI-powered solution and ultrasound radiologists with over 10 years of experience.The study lasted for one and a half years and was carried out in the Duanzhou District Women and Children's Hospital,Zhaoqing,China.1,133 females between 20 and 70 years old were selected through convenience sampling.Results:The accuracy,sensitivity,specificity,positive predictive value,and negative predictive value were 93.03%,94.90%,90.71%,92.68%,and 93.48%,respectively.The area under the curve(AUC)for all positives was 0.91569 and the AUC for all negatives was 0.90461.The comparison indicated that the overall performance of the AI system was comparable to that of ultrasound radiologists.Conclusion:This innovative AI-powered ultrasound solution is cost-effective and user-friendly,and could be applied to massive breast cancer screening. 展开更多
关键词 Breast cancer screening ultrasound Lesion detection BI-RADS Deep learning Computer vision Cloud computing
下载PDF
Endoscopic ultrasound guided radiofrequency ablation for pancreatic tumors: A critical review focusing on safety, efficacy and controversies 被引量:2
13
作者 Tawfik Khoury Wisam Sbeit Bertrand Napoléon 《World Journal of Gastroenterology》 SCIE CAS 2023年第1期157-170,共14页
The role of endoscopic ultrasound(EUS)in the last two decades has shifted from a diagnostic tool to an important therapeutic tool treating mainly pancreatobiliary disorders.In recent years,its applications for treatin... The role of endoscopic ultrasound(EUS)in the last two decades has shifted from a diagnostic tool to an important therapeutic tool treating mainly pancreatobiliary disorders.In recent years,its applications for treating pancreatic diseases have broadened,including the implementation of radiofrequency ablation(RFA),which has been traditionally used for treating solid tumors.In this critical indepth review,we summarized all the papers throughout the literature regarding EUS-RFA for pancreatic neuroendocrine neoplasms,adenocarcinoma,and pancreatic cystic lesions.Overall,for pancreatic neuroendocrine neoplasms we identified 16 papers that reported 96 patients who underwent EUS-RFA,with acceptable adverse events that were rated mild to moderate and a high complete radiological resolution rate of 90%.For pancreatic adenocarcinoma,we identified 8 papers with 121 patients.Adverse events occurred in 13%of patients,mostly rated mild.However,no clear survival benefit was demonstrated.For pancreatic cystic lesions,we identified 4 papers with 38 patients.The adverse events were mostly mild and occurred in 9.1%of patients,and complete or partial radiological resolution of the cysts was reported in 36.8%.Notably,the procedure was technically feasible for most of the patients.Nevertheless,a long road remains before this technique finds its definite place in guidelines due to several controversies.EUS-RFA for pancreatic tumors seems to be safe and effective,especially for pancreatic neuroendocrine neoplasms,but multicenter prospective trials are needed to consider this treatment as a gold standard. 展开更多
关键词 Endoscopic ultrasound Radiofrequency ablation EFFICACY SAFETY PANCREAS TUMORS
下载PDF
Percutaneous ultrasound and endoscopic ultrasound-guided biopsy of solid pancreatic lesions: An analysis of 1074 lesions 被引量:1
14
作者 Wei-Lu Chai Xiu-Feng Kuang +4 位作者 Li Yu Chao Cheng Xin-Yan Jin Qi-Yu Zhao Tian-An Jiang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2023年第3期302-309,共8页
Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-g... Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-guided pancreatic biopsies are lacking.This study aimed to evaluate and compare the diagnostic yields of US-and EUS-guided pancreatic biopsies and identify the risk factors for inconclusive biopsies.Methods:Of the 1074 solid pancreatic lesions diagnosed from January 2017 to February 2021 in our center,275 underwent EUS-guided fine needle aspiration(EUS-FNA),and 799 underwent US-guided core needle biopsy(US-CNB/FNA).The outcomes were inconclusive pathological biopsy,diagnostic accuracy and the need for repeat biopsy.All of the included factors and diagnostic performances of both USCNB/FNA and EUS-FNA were compared,and the independent predictors for the study outcomes were identified.Results:The diagnostic accuracy was 89.8%for EUS-FNA and 95.2%for US-CNB/FNA(P=0.001).Biopsy under EUS guidance[odds ratio(OR)=1.808,95%confidence interval(CI):1.083-3.019;P=0.024],lesion size<2 cm(OR=2.069,95%CI:1.145-3.737;P=0.016),hypoechoic appearance(OR=0.274,95%CI:0.097-0.775;P=0.015)and non-pancreatic ductal adenocarcinoma carcinoma(PDAC)diagnosis(OR=2.637,95%CI:1.563-4.449;P<0.001)were identified as factors associated with inconclusive pathological biopsy.Hypoechoic appearance(OR=0.236,95%CI:0.064-0.869;P=0.030),lesions in the uncinate process of the pancreas(OR=3.506,95%CI:1.831-6.713;P<0.001)and non-PDAC diagnosis(OR=2.622,95%CI:1.278-5.377;P=0.009)were independent predictors for repeat biopsy.Biopsy under EUS guidance(OR=2.024,95%CI:1.195-3.429;P=0.009),lesions in the uncinate process of the pancreas(OR=1.776,95%CI:1.014-3.108;P=0.044)and hypoechoic appearance(OR=0.127,95%CI:0.047-0.347;P<0.001)were associated with diagnostic accuracy.Conclusions:In conclusion,both percutaneous US-and EUS-guided biopsies of solid pancreatic lesions are safe and effective;though the diagnostic accuracy of EUS-FNA is inferior to US-CNB/FNA.A tailored pancreatic biopsy should be considered a part of the management algorithm for the diagnosis of solid pancreatic disease. 展开更多
关键词 PANCREATIC BIOPSY Fine needle aspiration ultrasound Endoscopic ultrasound
下载PDF
Value of contrast-enhanced ultrasound in deep angiomyxoma using a biplane transrectal probe:A case report 被引量:1
15
作者 Qiong Zhang Hua-Lin Yan +1 位作者 Qiang Lu Yan Luo 《World Journal of Gastroenterology》 SCIE CAS 2023年第26期4214-4221,共8页
BACKGROUND Deep angiomyxoma(DAM)is a very rare tumor type.Magnetic resonance imaging(MRI)is considered the best imaging modality for diagnosing DAM.Computed tomography(CT)is used mainly to assess the invasion range of... BACKGROUND Deep angiomyxoma(DAM)is a very rare tumor type.Magnetic resonance imaging(MRI)is considered the best imaging modality for diagnosing DAM.Computed tomography(CT)is used mainly to assess the invasion range of DAM.The value of ultrasonography in the diagnosis of DAM is still controversial.Through a literature review,we summarized the current state of ultrasonic examination for DAM and reported for the first time the contrast-enhanced ultrasound(CEUS)features of DAM seen using a biplane transrectal probe.CASE SUMMARY A 37-year-old woman presented with a sacrococcygeal mass that had gradually increased in size over the previous 6 mo.MRI and CT examinations failed to allow a definite diagnosis to be made.Transperineal core needle biopsy(CNB)guided by transrectal ultrasound and CEUS was suggested after a multidisciplinary discussion.Grayscale ultrasound of the lesion showed a layered appearance with alternating hyperechoic and hypoechoic patterns.Transrectal CEUS showed a laminated distribution of the contrast agent that was consistent with the layered appearance of the tumor on grayscale ultrasound.We performed transperineal CNB of the enhanced area inside the tumor under transrectal CEUS guidance and finally made a definitive diagnosis of DAM through histopathology.The patient underwent laparoscopic-assisted transabdominal surgery combined with transperineal surgery for large pelvic tumor resection and pelvic floor peritoneal reconstruction.No recurrence or metastasis was found at the ninemonth follow-up.CONCLUSION Transrectal CEUS can show the layered perfusion characteristics of the contrast agent,guiding subsequent transperineal CNB of the enhanced area within the DAM. 展开更多
关键词 Contrast-enhanced ultrasound Transrectal ultrasound Transperineal core needle biopsy Deep angiomyxoma Pelvic tumor Case report
下载PDF
Vault predicting after implantable collamer lens implantation using random forest network based on different features in ultrasound biomicroscopy images 被引量:1
16
作者 Bin Fang Qiu-Jian Zhu +1 位作者 Hui Yang Li-Cheng Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1561-1567,共7页
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we... AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection. 展开更多
关键词 random forest network ultrasound biomicroscopy images vault prediction implantable collamer lens
下载PDF
基于OBE的多学科协作教学模式在POCUS技术辅助内瘘管理的培训效果分析
17
作者 张洁婷 梁玉婷 +3 位作者 李敬辉 赵代鑫 李茵 魏爽 《中国血液净化》 CSCD 2024年第5期392-395,共4页
目的探讨基于成果导向教育理念(outcome-based education,OBE)的多学科协作教学模式在床边实时超声(point-of-care ultrasound,POCUS)辅助内瘘管理培训中的应用效果。方法招募培训对象,采用基于OBE的多学科协作教学模式设置POCUS技术在... 目的探讨基于成果导向教育理念(outcome-based education,OBE)的多学科协作教学模式在床边实时超声(point-of-care ultrasound,POCUS)辅助内瘘管理培训中的应用效果。方法招募培训对象,采用基于OBE的多学科协作教学模式设置POCUS技术在血液透析患者内瘘管理中应用的培训框架和内容,对来自57家血液透析中心的70例护士实施培训并评价效果。结果实施培训后,护士对使用POCUS进行内瘘管理的信心得分为39.00(38.00,41.00)分,高于培训前的21.00(20.00,25.00)分(Z=7.278,P<0.001)。考核结果显示考核通过率为90.00%,考核总成绩为82.50(69.73,89.78)分,其中55.71%良好,34.29%中等,10.00%较差。结论基于OBE和多学科协作模式开展教学活动,有助于血液透析护士在较短的时间内系统地学习POCUS技术,值得推广。 展开更多
关键词 多学科协作 成果导向教育理念 床边实时超声 血液透析
下载PDF
Diagnostic and therapeutic role of endoscopic ultrasound in liver diseases:A systematic review and meta-analysis 被引量:2
18
作者 Eyad Gadour Abeer Awad +3 位作者 Zeinab Hassan Khalid Jebril Shrwani Bogdan Miutescu Hussein Hassan Okasha 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期742-758,共17页
BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefor... BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases. 展开更多
关键词 Focal liver lesion Liver abscess drainage Fine needle aspiration Gastric varices Endoscopic ultrasound
下载PDF
mpMRI/TRUS融合引导下前列腺靶向穿刺活检中漏诊原因
19
作者 李自亨 史蕾 +1 位作者 刘沧海 张云良 《吉林医学》 CAS 2024年第7期1580-1583,共4页
目的:研究多参数磁共振成像(mpMRl)/手指引导、经直肠超声(TRUS)融合引导下的前列腺靶向穿刺活检(TB)中漏诊的原因。方法:回顾性分析2021年1月~2023年9月山东省荣军总医院行经会阴前列腺穿刺活检的97例患者的临床资料。在mpMRI和Pl-RAD... 目的:研究多参数磁共振成像(mpMRl)/手指引导、经直肠超声(TRUS)融合引导下的前列腺靶向穿刺活检(TB)中漏诊的原因。方法:回顾性分析2021年1月~2023年9月山东省荣军总医院行经会阴前列腺穿刺活检的97例患者的临床资料。在mpMRI和Pl-RADS评分后完成了mpMRI/TRUS融合引导的前列腺经会阴TB+经会阴系统穿刺活检(SB)。比较TB和SB的病理诊断,评价和分析TB漏诊的原因。结果:共有52例患者被确诊为前列腺癌,其中TB漏诊5例(9.62%),SB漏诊6例(11.53%)。TB漏诊组和未漏诊组之间年龄比较差异无统计学意义(P>0.05),但前列腺特异性抗原(PSA)、前列腺体积(PV)、PSA密度(PSAD)及国际泌尿病理学学会(ISUP)等级比较,差异有统计学意义(P<0.05)。将5例TB漏诊的病理结果与磁共振成像(MRI)进行重新比较:3例前列腺癌MRI正常,1例癌灶MRl异常,1例癌灶MRI升级为Pl-RADS 3。结论:早期前列腺癌、大前列腺、局部麻醉及患者的配合、MRI阅读人员和穿刺操作人员的经验都可能是TB漏诊的原因。故个性化的活检计划、更好的成像技术、丰富的操作和阅片经验以及更智能的融合系统能够降低漏诊率,提高TB阳性率。 展开更多
关键词 经直肠超声 磁共振 前列腺癌 靶向活检 系统活检 漏诊
下载PDF
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation 被引量:1
20
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 Point-of-care ultrasound Bedside ultrasound Internal jugular vein Right atrial pressure Central venous pressure
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部