期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
REMOVAL OF INTRACANAL OBSTRUCTIONS WITH ULTRASOUND ANALYSIS OF 206 CASES
1
作者 王晓仪 王哲明 洪瑾 《Chinese Medical Journal》 SCIE CAS CSCD 1994年第6期76-79,共4页
Intracanal obstructions were removed with ultrasound in 206 cases, with a success rate of 97.08%. Six cases (2.92%) failed owing to broken endodonric instruments at the apical third or in the curved and fine canals. T... Intracanal obstructions were removed with ultrasound in 206 cases, with a success rate of 97.08%. Six cases (2.92%) failed owing to broken endodonric instruments at the apical third or in the curved and fine canals. The success rate of retrieval of casting post-core or other foreign objects was 100%. Our experience proves that ultrasonic technique is more effective and safer than any other methods for the removal of intracanal obstructions. 展开更多
关键词 REMOVAL OF INTRACANAL OBSTRUCTIONS WITH ultrasound analysis OF 206 CASES
原文传递
Characterization and analysis of coded excitation ultrasound parameters for rock properties 被引量:2
2
作者 ZHU Wei WU Hezhen 《Chinese Journal of Acoustics》 CSCD 2017年第1期29-42,共14页
Coded excitation technology (CET) can effectively enhance the penetration and resolution of ultrasonic testing. To analyze the influence of rock properties on pulse compression performance (PCP) of coded excitatio... Coded excitation technology (CET) can effectively enhance the penetration and resolution of ultrasonic testing. To analyze the influence of rock properties on pulse compression performance (PCP) of coded excitation signals (CES), a numerical simulation, and an ultrasonic experiment on different rock samples are performed; and the detection ability of several CESs are also investigated and compared. The results of experiments showed that the loss of the signal-to-noise ratio (SNR) of Barker coded signal with tapered linear frequency modulated carrier (BTLFM) is always less than Barker coded signal with sine carrier (BS), while the resolution loss of BTLFM is lower than tapered linear frequency modulated signal (TLFM). In sum, the results not only verifiy the effectiveness of CET, but also provide a basis for the parameter settings of coded signals used in rock ultrasonic testing. 展开更多
关键词 ROCK Characterization and analysis of coded excitation ultrasound parameters for rock properties
原文传递
Simulation and feature analysis for gas emboli Doppler ultrasound signals 被引量:1
3
作者 WANG Teng WANG Yuanyuan 《Chinese Journal of Acoustics》 2013年第1期79-89,共11页
The purpose of this study is to establish the simulation model of the gas emboli by analyzing reasons for features of gas emboli Doppler ultrasound signals. It is useful for the further classification of the solid emb... The purpose of this study is to establish the simulation model of the gas emboli by analyzing reasons for features of gas emboli Doppler ultrasound signals. It is useful for the further classification of the solid emboli and gas emboli. First, the model of the radiation force and the drag force is used to calculate forces acting on the gas emboli. Second, the acceleration of the gas emboli is calculated in both the radial direction and the axial direction of the vessel, which is used to calculate the trajectory of the gas emboli in the vessel. Finally, the computer simulation model is established for the gas emboli. Doppler ultrasound signals of the gas emboli and the solid emboli are generated in the simulation experiment. Experimental results show that compared with the solid emboli, the gas emboli acted by the radiation force and the drag force will result in the frequency-domain broaden in the Doppler spectrogram. When the gas emboli circulate from the low speed area to the high speed one and then from the high speed area back to the low speed one, a "V" shape will be shown in the spectrogram of gas emboli signals. When the gas emboli circulate from the low speed area to the high speed one or from the high speed area to the low speed one, a diagonal shape will be shown for gas emboli signals. It is also shown that features of simulated gas emboli signals match with those of gas emboli signals sampled from clinic. All demonstrate that the simulation method of the gas emboli is reasonable. 展开更多
关键词 Simulation and feature analysis for gas emboli Doppler ultrasound signals HIGH
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部