Endoscopic ultrasound (EUS) devices were first designed and manufactured more than 30 years ago, and since then investigators have reported EUS is effective for determining both the staging and the depth of invasion o...Endoscopic ultrasound (EUS) devices were first designed and manufactured more than 30 years ago, and since then investigators have reported EUS is effective for determining both the staging and the depth of invasion of esophageal and gastric cancers. We review the present status, the methods, and the findings of EUS when used to diagnose and stage early esophageal and gastric cancer. EUS using high-frequency ultrasound probes is more accurate than conventional EUS for the evaluation of the depth of invasion of superficial esophageal carcinoma. The rates of accurate evaluation of the depth of invasion by EUS using high-frequency ultrasound probes were 70%-88% for intramucosal cancer, and 83%-94% for submucosal invasive cancer. But the sensitivity of EUS using high-frequency ultrasound probes for the diagnosis of submucosal invasive cancer was relatively low, making it difficult to confirm minute submucosal invasion. The accuracy of EUS using high-frequency ultrasound probes for early gastric tumor classification can be up to 80% compared with 63% for conventional EUS, although the accuracy of EUS using high-frequency ultrasound probes relatively decreases for those patients with depressed-type lesions, undifferentiated cancer, concomitant ulceration, expanded indications, type 0-I?lesions, and lesions located in the upper-third of the stomach. A 92% overall accuracy rate was achieved when both the endoscopic appearance and the findings from EUS using high-frequency ultrasound probes were considered together for tumor classification. Although EUS using high-frequency ultrasound probes has limitations, it has a high depth of invasion accuracy and is a useful procedure to distinguish lesions in the esophagus and stomach that are indicated for endoscopic resection.展开更多
We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance in...We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.展开更多
Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical t...Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods: Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results: CM examination data were analyzed for 127 women at 24<sup>0/7</sup> - 28<sup>6/7</sup> gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group’s 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10<sup>−</sup><sup>4</sup>. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion: These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner.展开更多
Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clini...Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clinical practice to evaluate the hepatic inflow, yet invasive. The phase-contrast-MRI(PC-MRI) is not invasive and potentially applicable in assessing the hepatic blood flow. In the present study, we compared the hepatic inflow rates using the PC-MRI and the TTUS probe, and evaluated their predictive value of post-hepatectomy adverse events. Methods: Eighteen large white pigs were anaesthetized for PC-MRI and approximately 75% hepatic resection was performed under a unified protocol. The blood flow was measured in the hepatic artery(Qha), the portal vein(Qpv), and the aorta above the celiac trunk(Qca) using PC-MRI, and was compared to the TTUS probe. The Bland-Altman method was conducted and a partial least squares regression(PLS) model was implemented. Results: The mean Qpv measured in PC-MRI was 0.55 ± 0.12 L/min, and in the TTUS probe was 0.74 ± 0.17 L/min. Qca was 1.40 ± 0.47 L/min in the PC-MRI and 2.00 ± 0.60 L/min in the TTUS probe. Qha was 0.17 ± 0.10 L/min in the PC-MRI, and 0.13 ± 0.06 L/min in the TTUS probe. The Bland-Altman method revealed that the estimated bias of Qca in the PC-MRI was 32%(95% CI:-49% to 15%); Qha 17%(95% CI:-15% to 51%); and Qpv 40%(95% CI:-62% to 18%). The TTUS probe had a higher weight in predicting adverse outcomes after 75% resection compared to the PC-MRI( β= 0.35 and 0.43 vs β = 0.22 and 0.07, for tissue changes and premature death, respectively). Conclusions: There is a tendency of the PC-MRI to underestimate the flow measured by the TTUS probes. The TTUS probe measures are more predictive of relevant post-hepatectomy outcomes.展开更多
AIM: To assess the therapeutic value of endoscopic mucosal resection (EMR) under micro-probe ultrasound guidance for rectal carcinoids less than 1 cm in diameter. METHODS: Twenty-one patients pathologically diagnosed ...AIM: To assess the therapeutic value of endoscopic mucosal resection (EMR) under micro-probe ultrasound guidance for rectal carcinoids less than 1 cm in diameter. METHODS: Twenty-one patients pathologically diagnosed with rectal carcinoids following colonoscopy in our hospital from January 2007 to November 2012 were included in this study. The patients consisted of 14 men and 7 women, with a mean age of 52.3 ± 12.2 years (range: 36-72 years). The patients with submucosal tumors less than 1 cm in diameter arising from the rectal and muscularis mucosa detected by micro-probe ultrasound were treated with EMR and followed up with conventional endoscopy and micro-probe ultrasound. RESULTS: All of the 21 tumors were confirmed by micro-probe ultrasound as uniform hypoechoic masses originating from the rectal and muscularis mucosa, without invasion of muscularis propria and vessels, and less than 1 cm in diameter. EMR was successfully completed without bleeding, perforation or other complications. The resected specimens were immunohistochemically confirmed to be carcinoids. Patients were followed up for one to two years, and no tumor recurrence was reported. CONCLUSION: EMR is a safe and effective treatment for rectal carcinoids less than 1 cm in diameter.展开更多
目的探讨超细支气管镜、Guide sheath外周超声小探头K201/K203系统(EBUS-GS)联合快速现场评价(玫瑰系统,rapid on site evaluation,ROSE)对外周肺感染性病灶的诊断价值和安全性。方法回顾性收集胸部螺旋CT显示为外周肺病变且最终确诊为...目的探讨超细支气管镜、Guide sheath外周超声小探头K201/K203系统(EBUS-GS)联合快速现场评价(玫瑰系统,rapid on site evaluation,ROSE)对外周肺感染性病灶的诊断价值和安全性。方法回顾性收集胸部螺旋CT显示为外周肺病变且最终确诊为外周感染性肺病变的196例患者的临床资料。根据诊断技术的不同分为超细支气管镜联合ROSE组、EBUS-GS联合ROSE组、超细支气管镜和EBUS-GS联合ROSE组。记录患者的一般情况、确诊结果、具体操作参数,比较各组诊断率、敏感度以及并发症情况。结果超细支气管镜和EBUS-GS联合ROSE组定位病变时间和操作时间最短、支气管镜到达支气管级数最高,超细支气管镜联合ROSE组定位病变时间和操作时间最长,EBUS-GS联合ROSE组支气管镜到达支气管级数最低,任意两组间差异均有统计学意义(P<0.05)。所有患者、细菌性肺炎患者、肺结核及非结核分枝杆菌病患者中,超细支气管镜和EBUS-GS联合ROSE组经支气管镜明确诊断率、ROSE诊断敏感度最高,跟另外两组相比差异有统计学意义(P<0.05)。各组并发症发生率均较低,任意两组间差异均无统计学意义(P>0.05)。结论超细支气管镜和EBUS-GS联合ROSE可使定位病变时间和操作时间明显缩短,诊断准确率和敏感度明显提高,并发症少,安全可行,报告快速直接,值得临床上推广使用。展开更多
文摘Endoscopic ultrasound (EUS) devices were first designed and manufactured more than 30 years ago, and since then investigators have reported EUS is effective for determining both the staging and the depth of invasion of esophageal and gastric cancers. We review the present status, the methods, and the findings of EUS when used to diagnose and stage early esophageal and gastric cancer. EUS using high-frequency ultrasound probes is more accurate than conventional EUS for the evaluation of the depth of invasion of superficial esophageal carcinoma. The rates of accurate evaluation of the depth of invasion by EUS using high-frequency ultrasound probes were 70%-88% for intramucosal cancer, and 83%-94% for submucosal invasive cancer. But the sensitivity of EUS using high-frequency ultrasound probes for the diagnosis of submucosal invasive cancer was relatively low, making it difficult to confirm minute submucosal invasion. The accuracy of EUS using high-frequency ultrasound probes for early gastric tumor classification can be up to 80% compared with 63% for conventional EUS, although the accuracy of EUS using high-frequency ultrasound probes relatively decreases for those patients with depressed-type lesions, undifferentiated cancer, concomitant ulceration, expanded indications, type 0-I?lesions, and lesions located in the upper-third of the stomach. A 92% overall accuracy rate was achieved when both the endoscopic appearance and the findings from EUS using high-frequency ultrasound probes were considered together for tumor classification. Although EUS using high-frequency ultrasound probes has limitations, it has a high depth of invasion accuracy and is a useful procedure to distinguish lesions in the esophagus and stomach that are indicated for endoscopic resection.
基金supported by Hunan Health and Family Planning Commission program[C2017060]
文摘We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.
文摘Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods: Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results: CM examination data were analyzed for 127 women at 24<sup>0/7</sup> - 28<sup>6/7</sup> gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group’s 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10<sup>−</sup><sup>4</sup>. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion: These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner.
基金supported mainly by the “Agence de la Biomedecine” through its program of Research(AOR 2009)BM,AC,BP,WM,VCI and VE acknowledged funding of project ANR-13-TECS-0006 by the Agence Nationale de la Recherche
文摘Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clinical practice to evaluate the hepatic inflow, yet invasive. The phase-contrast-MRI(PC-MRI) is not invasive and potentially applicable in assessing the hepatic blood flow. In the present study, we compared the hepatic inflow rates using the PC-MRI and the TTUS probe, and evaluated their predictive value of post-hepatectomy adverse events. Methods: Eighteen large white pigs were anaesthetized for PC-MRI and approximately 75% hepatic resection was performed under a unified protocol. The blood flow was measured in the hepatic artery(Qha), the portal vein(Qpv), and the aorta above the celiac trunk(Qca) using PC-MRI, and was compared to the TTUS probe. The Bland-Altman method was conducted and a partial least squares regression(PLS) model was implemented. Results: The mean Qpv measured in PC-MRI was 0.55 ± 0.12 L/min, and in the TTUS probe was 0.74 ± 0.17 L/min. Qca was 1.40 ± 0.47 L/min in the PC-MRI and 2.00 ± 0.60 L/min in the TTUS probe. Qha was 0.17 ± 0.10 L/min in the PC-MRI, and 0.13 ± 0.06 L/min in the TTUS probe. The Bland-Altman method revealed that the estimated bias of Qca in the PC-MRI was 32%(95% CI:-49% to 15%); Qha 17%(95% CI:-15% to 51%); and Qpv 40%(95% CI:-62% to 18%). The TTUS probe had a higher weight in predicting adverse outcomes after 75% resection compared to the PC-MRI( β= 0.35 and 0.43 vs β = 0.22 and 0.07, for tissue changes and premature death, respectively). Conclusions: There is a tendency of the PC-MRI to underestimate the flow measured by the TTUS probes. The TTUS probe measures are more predictive of relevant post-hepatectomy outcomes.
文摘AIM: To assess the therapeutic value of endoscopic mucosal resection (EMR) under micro-probe ultrasound guidance for rectal carcinoids less than 1 cm in diameter. METHODS: Twenty-one patients pathologically diagnosed with rectal carcinoids following colonoscopy in our hospital from January 2007 to November 2012 were included in this study. The patients consisted of 14 men and 7 women, with a mean age of 52.3 ± 12.2 years (range: 36-72 years). The patients with submucosal tumors less than 1 cm in diameter arising from the rectal and muscularis mucosa detected by micro-probe ultrasound were treated with EMR and followed up with conventional endoscopy and micro-probe ultrasound. RESULTS: All of the 21 tumors were confirmed by micro-probe ultrasound as uniform hypoechoic masses originating from the rectal and muscularis mucosa, without invasion of muscularis propria and vessels, and less than 1 cm in diameter. EMR was successfully completed without bleeding, perforation or other complications. The resected specimens were immunohistochemically confirmed to be carcinoids. Patients were followed up for one to two years, and no tumor recurrence was reported. CONCLUSION: EMR is a safe and effective treatment for rectal carcinoids less than 1 cm in diameter.
文摘目的探讨超细支气管镜、Guide sheath外周超声小探头K201/K203系统(EBUS-GS)联合快速现场评价(玫瑰系统,rapid on site evaluation,ROSE)对外周肺感染性病灶的诊断价值和安全性。方法回顾性收集胸部螺旋CT显示为外周肺病变且最终确诊为外周感染性肺病变的196例患者的临床资料。根据诊断技术的不同分为超细支气管镜联合ROSE组、EBUS-GS联合ROSE组、超细支气管镜和EBUS-GS联合ROSE组。记录患者的一般情况、确诊结果、具体操作参数,比较各组诊断率、敏感度以及并发症情况。结果超细支气管镜和EBUS-GS联合ROSE组定位病变时间和操作时间最短、支气管镜到达支气管级数最高,超细支气管镜联合ROSE组定位病变时间和操作时间最长,EBUS-GS联合ROSE组支气管镜到达支气管级数最低,任意两组间差异均有统计学意义(P<0.05)。所有患者、细菌性肺炎患者、肺结核及非结核分枝杆菌病患者中,超细支气管镜和EBUS-GS联合ROSE组经支气管镜明确诊断率、ROSE诊断敏感度最高,跟另外两组相比差异有统计学意义(P<0.05)。各组并发症发生率均较低,任意两组间差异均无统计学意义(P>0.05)。结论超细支气管镜和EBUS-GS联合ROSE可使定位病变时间和操作时间明显缩短,诊断准确率和敏感度明显提高,并发症少,安全可行,报告快速直接,值得临床上推广使用。