A microfiber with large evanescent field encapsulated in PDMS is proposed and demonstrated for ultrasound sensing.The compact size and large evanescent field of microfiber provide an excellent platform for the interac...A microfiber with large evanescent field encapsulated in PDMS is proposed and demonstrated for ultrasound sensing.The compact size and large evanescent field of microfiber provide an excellent platform for the interaction between optical signal and ultrasound wave,exhibiting a high sensitivity of 3.5 mV/kPa,which is approximately 10 times higher than the single-mode fiber sensor.Meanwhile,a phase feedback stabilization module is introduced into the coherent demodulation system for long-term stable measurement.In addition,a photoacoustic tomography experiment with the microfiber ultrasound sensor is implemented to verify the excellent performance on imaging,with the depth of 12 mm,the highest lateral resolution of 65μm and axial resolution of 250μm,respectively.The highly sensitive microfiber ultrasound sensor provides a competitive alternative for various applications,such as industrial non-destructive testing,biomedical ultrasound and photoacoustic imaging.展开更多
Photoacoustic imag ing(PAI)is a nonin vasive biomedical imag ing tech no logy capable of multiscale imag ing of biological samples from orga ns dow n to cells.Multiscale PAI requires differe nt ultraso und tra nsducer...Photoacoustic imag ing(PAI)is a nonin vasive biomedical imag ing tech no logy capable of multiscale imag ing of biological samples from orga ns dow n to cells.Multiscale PAI requires differe nt ultraso und tra nsducers that are flat or focused because the current widely-used piezoelectric transducers are rigid and lack the flexibility to tune their spatial ultrasound responses.Inspired by the rapidly-developing flexible photonics,we exploited the inherent flexibility and low-loss features of optical fibers to develop a flexible fiber-laser ultrasound sensor(FUS)for multiscale PAI.By simply bending the fiber laser from straight to curved geometry,the spatial ultraso und resp onse of the FUS can be tuned for both wide-view optical-resolution photoacoustic microscopy at optical diffraction-limited depth(~1 mm)and photoacoustic computed tomography at optical dissipation-limited depth of several centimeters.A radio-frequency demodulation was employed to get the readout of the beat frequency variation of two orthogonal polarization modes in the FUS output,which ensures low-noise and stable ultrasound detection.Compared to traditional piezoelectrical transducers with fixed ultrasound responses once manufactured,the flexible FUS provides the freedom to design multiscale PAI modalities including wearable microscope,intravascular endoscopy,and portable tomography system,which is attractive to fundamental biologic-al/medical studies and clinical applications.展开更多
Fish finders have already been widely available in the fishing market for a number of years.However,the sizes of these fish finders are too big and their prices are expensive to suit for the research of robotic fish o...Fish finders have already been widely available in the fishing market for a number of years.However,the sizes of these fish finders are too big and their prices are expensive to suit for the research of robotic fish or mini-submarine.The goal of this research is to propose a low-cost fish detector and classifier which suits for underwater robot or submarine as a proximity sensor. With some pre-condition in hardware and algorithms,the experimental results show that the proposed design has good per- formance,with a detection rate of 100 % and a classification rate of 94 %.Both the existing type of fish and the group behavior can be revealed by statistical interpretations such as hovering passion and sparse swimming mode.展开更多
In Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the fuel debris formed in the Reactor Pressure Vessel (RPV) and Primary Containment Vessel (PCV) at Unit 1</span><span style="font-family:Verdan...In Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the fuel debris formed in the Reactor Pressure Vessel (RPV) and Primary Containment Vessel (PCV) at Unit 1</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">-</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">3. To accelerate and decide further decommissioning steps of the FDNPP, it is crucial to obtain realistic information of the debris and localize contaminated water leakage from PCV. Due to high radiation and dark environment inside the PCV, investigating instruments and techniques should necessarily to meet specification of radiation resistance, waterproofness, dust resistance and so on. This study focuses on development of ultrasonic measurement system using a couple of sectorial array sensors to localize contaminated water leakage and visualize shape of object that repre</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">senting fuel debris, simultaneously. In this study, Total Focusing Method</span><span style="font-family:Verdana;"> (TFM) and Ultrasonic Velocity Profiler (UVP) methods are considered to visualize object shape and flow pattern around it, respectively. To demonstrate applicability and reliability of developed measurement system with sectorial array sensors, a mock-up experiment result</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">of simulated water leakage and fuel debris shape were discussed in this paper.展开更多
基金financial supports from National Natural Science Foundation of China (NSFC)(No.61922033)Foundation for Innovative Research Groups of Hubei Province of China (2018CFA004)Innovation Fund of WNLO
文摘A microfiber with large evanescent field encapsulated in PDMS is proposed and demonstrated for ultrasound sensing.The compact size and large evanescent field of microfiber provide an excellent platform for the interaction between optical signal and ultrasound wave,exhibiting a high sensitivity of 3.5 mV/kPa,which is approximately 10 times higher than the single-mode fiber sensor.Meanwhile,a phase feedback stabilization module is introduced into the coherent demodulation system for long-term stable measurement.In addition,a photoacoustic tomography experiment with the microfiber ultrasound sensor is implemented to verify the excellent performance on imaging,with the depth of 12 mm,the highest lateral resolution of 65μm and axial resolution of 250μm,respectively.The highly sensitive microfiber ultrasound sensor provides a competitive alternative for various applications,such as industrial non-destructive testing,biomedical ultrasound and photoacoustic imaging.
基金This work was supported by the National Natural Science Foundation of China(61775083,61705082,61805102,and 61860206002)the Local Innovative and Research Teams Project of Guangdong Pearl River Talents Program(2019BT02X105)Guangzhou Science and Technology Plan(201904020032).
文摘Photoacoustic imag ing(PAI)is a nonin vasive biomedical imag ing tech no logy capable of multiscale imag ing of biological samples from orga ns dow n to cells.Multiscale PAI requires differe nt ultraso und tra nsducers that are flat or focused because the current widely-used piezoelectric transducers are rigid and lack the flexibility to tune their spatial ultrasound responses.Inspired by the rapidly-developing flexible photonics,we exploited the inherent flexibility and low-loss features of optical fibers to develop a flexible fiber-laser ultrasound sensor(FUS)for multiscale PAI.By simply bending the fiber laser from straight to curved geometry,the spatial ultraso und resp onse of the FUS can be tuned for both wide-view optical-resolution photoacoustic microscopy at optical diffraction-limited depth(~1 mm)and photoacoustic computed tomography at optical dissipation-limited depth of several centimeters.A radio-frequency demodulation was employed to get the readout of the beat frequency variation of two orthogonal polarization modes in the FUS output,which ensures low-noise and stable ultrasound detection.Compared to traditional piezoelectrical transducers with fixed ultrasound responses once manufactured,the flexible FUS provides the freedom to design multiscale PAI modalities including wearable microscope,intravascular endoscopy,and portable tomography system,which is attractive to fundamental biologic-al/medical studies and clinical applications.
基金This research was fund by Fundamental Research Fund Program from Indonesia Ministry of Research and Technology in years 2007. ID Number: RD-2009-2550.
文摘Fish finders have already been widely available in the fishing market for a number of years.However,the sizes of these fish finders are too big and their prices are expensive to suit for the research of robotic fish or mini-submarine.The goal of this research is to propose a low-cost fish detector and classifier which suits for underwater robot or submarine as a proximity sensor. With some pre-condition in hardware and algorithms,the experimental results show that the proposed design has good per- formance,with a detection rate of 100 % and a classification rate of 94 %.Both the existing type of fish and the group behavior can be revealed by statistical interpretations such as hovering passion and sparse swimming mode.
文摘In Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the fuel debris formed in the Reactor Pressure Vessel (RPV) and Primary Containment Vessel (PCV) at Unit 1</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">-</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">3. To accelerate and decide further decommissioning steps of the FDNPP, it is crucial to obtain realistic information of the debris and localize contaminated water leakage from PCV. Due to high radiation and dark environment inside the PCV, investigating instruments and techniques should necessarily to meet specification of radiation resistance, waterproofness, dust resistance and so on. This study focuses on development of ultrasonic measurement system using a couple of sectorial array sensors to localize contaminated water leakage and visualize shape of object that repre</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">senting fuel debris, simultaneously. In this study, Total Focusing Method</span><span style="font-family:Verdana;"> (TFM) and Ultrasonic Velocity Profiler (UVP) methods are considered to visualize object shape and flow pattern around it, respectively. To demonstrate applicability and reliability of developed measurement system with sectorial array sensors, a mock-up experiment result</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">of simulated water leakage and fuel debris shape were discussed in this paper.
文摘开关柜是电力系统的重要组成设备,其在出厂和长期运行中不可避免地会出现绝缘缺陷,导致设备故障。局部放电检测是发现开关柜绝缘缺陷的有效手段,为了提高开关柜局部放电检测的灵敏度,提出了超声–暂态对地电压(transient earth voltage,TEV)融合传感技术并设计了融合传感器,实现了超声信号与TEV信号在时空上的同步测量。对融合传感器的校准试验结果表明,超声的平均灵敏度在20~60 kHz内为63.90 dB;TEV的平均灵敏度在1~40 MHz内为46.98 d B,满足开关柜局部放电检测需求。在10 k V开关柜上进行了基于缺陷模型的局部放电试验,结果表明,该文提出的融合传感技术在准确测量局部放电信号的同时可以准确地实现放电定位,为开关柜局部放电检测提供了新的思路与方案。