期刊文献+
共找到474篇文章
< 1 2 24 >
每页显示 20 50 100
Ovarian-adnexal reporting and data system ultrasound evaluation and pathological characteristics of ovarian collision tumor
1
作者 Chan Yin Yong Wang +3 位作者 Zhi-Hui Fei Li-Hong Sun Wei-Ai Zhou Heng Li 《World Journal of Clinical Cases》 SCIE 2024年第22期4932-4939,共8页
BACKGROUND Collision tumor are neoplasms,including two histologically distinct tumors that coexist in the same mass without histological admixture.The incidence of collision tumor is low and is rare clinically.AIM To ... BACKGROUND Collision tumor are neoplasms,including two histologically distinct tumors that coexist in the same mass without histological admixture.The incidence of collision tumor is low and is rare clinically.AIM To investigate ultrasound images and application of ovarian-adnexal reporting and data system(O-RADS)to evaluate the risk and pathological characteristics of ovarian collision tumor.METHODS This study retrospectively analyzed 17 cases of ovarian collision tumor diagnosed pathologically from January 2020 to December 2023.All clinical features,ultrasound images and histopathological features were collected and analyzed.The O-RADS score was used for classification.The O-RADS score was determined by two senior doctors in the gynecological ultrasound group.Lesions with O-RADS score of 1-3 were classified as benign tumors,and lesions with O-RADS score of 4 or 5 were classified as malignant tumors.RESULTS There were 17 collision tumors detected in 16 of 6274 patients who underwent gynecological surgery.The average age of 17 women with ovarian collision tumor was 36.7 years(range 20-68 years),in whom,one occurred bilaterally and the rest occurred unilaterally.The average tumor diameter was 10 cm,of which three were 2-5 cm,11 were 5-10 cm,and three were>10 cm.Five(29.4%)tumors with O-RADS score 3 were endometriotic cysts with fibroma/serous cystadenoma,and unilocular or multilocular cysts contained a small number of parenchymal components.Eleven(64.7%)tumors had an O-RADS score of 4,including two in category 4A,six in category 4B,and three in category 4C;all of which were multilocular cystic tumors with solid components or multiple papillary components.One(5.9%)tumor had an O-RADS score of 5.This case was a solid mass,and a small amount of pelvic effusion was detected under ultrasound.The pathology was high-grade serous cystic cancer combined with cystic mature teratoma.There were nine(52.9%)tumors with elevated serum carbohydrate antigen(CA)125 and two(11.8%)with elevated serum CA19-9.Histological and pathological results showed that epithelial-cell-derived tumors combined with other tumors were the most common,which was different from previous results.CONCLUSION The ultrasound images of ovarian collision tumor have certain specificity,but diagnosis by preoperative ultrasound is difficult.The combination of epithelial and mesenchymal cell tumors is one of the most common types of ovarian collision tumor.The O-RADS score of ovarian collision tumor is mostly≥4,which can sensitively detect malignant tumors. 展开更多
关键词 Ovarian collision tumor Ovarian-adnexal reporting and data system Epithelial tumor Serous cystadenoma ultrasound images
下载PDF
Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions 被引量:18
2
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期610-617,共8页
AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesion... AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesions classified as BI-RADS 4 on conventional ultrasound were evaluated. CEUS was performed within one week before core needle biopsy or surgical resection and a revised BI-RADS classification was assigned based on 10 CEUS imaging characteristics. Receiver operating characteristic curve analysis was then conducted to evaluate the diagnostic performance of CEUS-based BI-RADS assignment with pathological examination as reference criteria. RESULTS: The CEUS-based BI-RADS evaluation classified 116/235(49.36%) lesions into category 3, 20(8.51%), 13(5.53%) and 12(5.11%) lesions into categories 4A, 4B and 4C, respectively, and 74(31.49%) into category 5. Selecting CEUS-based BI-RADS category 4A as an appropriate cut-off gave sensitivity and specificity values of 85.4% and 87.8%, respectively, for the diagnosisof malignant disease. The cancer-to-biopsy yield was 73.11% with CEUS-based BI-RADS 4A selected as the biopsy threshold compared with 40.85% otherwise, while the biopsy rate was only 42.13% compared with 100% otherwise. Overall, only 4.68% of invasive cancers were misdiagnosed.CONCLUSION: This pilot study suggests that evaluation of BI-RADS 4 breast lesions with CEUS results in reduced biopsy rates and increased cancer-to-biopsy yields. 展开更多
关键词 BREAST imaging reporting and data system CONTRAST-ENHANCED ultrasound BIOPSY False POSITIVE BIOPSY
下载PDF
Predictive model for contrast-enhanced ultrasound of the breast: Is it feasible in malignant risk assessment of breast imaging reporting and data system 4 lesions? 被引量:10
3
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期600-609,共10页
AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(B... AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(BI-RADS) 4 solid breast lesions were imaged via CEUS before core needle biopsy or surgical resection. CEUS results were analyzed on 10 enhancing patterns to evaluate diagnostic performance of three benign and three malignant CEUS models, with pathological results used as the gold standard. A logistic regression model was developed basing on the CEUS results, and then evaluated with receiver operating curve(ROC). RESULTS: Except in cases of enhanced homogeneity, the rest of the 9 enhancement appearances were statistically significant(P < 0.05). These 9 enhancement patterns were selected in the final step of the logistic regression analysis, with diagnostic sensitivity and specificity of 84.4% and 82.7%, respectively, and the area under the ROC curve of 0.911. Diagnostic sensitivity, specificity, and accuracy of the malignant vs benign CEUS models were 84.38%, 87.77%, 86.38% and 86.46%, 81.29% and 83.40%, respectively. CONCLUSION: The breast CEUS models can predict risk of malignant breast lesions more accurately, decrease false-positive biopsy, and provide accurate BIRADS classification. 展开更多
关键词 BREAST CONTRAST-ENHANCED ultrasound Qualitative analysis BREAST imaging reporting and data system PREDICTIVE model
下载PDF
Contrast-enhanced ultrasound Liver Imaging Reporting and Data System:Lights and shadows in hepatocellular carcinoma and cholangiocellular carcinoma diagnosis 被引量:6
4
作者 Gianpaolo Vidili Marco Arru +13 位作者 Giuliana Solinas Diego Francesco Calvisi Pierluigi Meloni Assunta Sauchella Davide Turilli Claudio Fabio Antonio Cossu Giordano Madeddu Sergio Babudieri Maria Assunta Zocco Giovanni Iannetti Enza Di Lembo Alessandro Palmerio Delitala Roberto Manetti 《World Journal of Gastroenterology》 SCIE CAS 2022年第27期3488-3502,共15页
BACKGROUND Contrast-enhanced ultrasound(CEUS)is considered a secondary examination compared to computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of hepatocellular carcinoma(HCC),due to the ris... BACKGROUND Contrast-enhanced ultrasound(CEUS)is considered a secondary examination compared to computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of hepatocellular carcinoma(HCC),due to the risk of misdiagnosing intrahepatic cholangiocarcinoma(ICC).The introduction of CEUS Liver Imaging Reporting and Data System(CEUS LI-RADS)might overcome this limitation.Even though data from the literature seems promising,its reliability in real-life context has not been well-established yet.AIM To test the accuracy of CEUS LI-RADS for correctly diagnosing HCC and ICC in cirrhosis.METHODS CEUS LI-RADS class was retrospectively assigned to 511 nodules identified in 269 patients suffering from liver cirrhosis.The diagnostic standard for all nodules was either biopsy(102 nodules)or CT/MRI(409 nodules).Common diagnostic accuracy indexes such as sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NPV)were assessed for the following associations:CEUS LR-5 and HCC;CEUS LR-4 and 5 merged class and HCC;CEUS LR-M and ICC;and CEUS LR-3 and malignancy.The frequency of malignant lesions in CEUS LR-3 subgroups with different CEUS patterns was also determined.Inter-rater agreement for CEUS LI-RADS class assignment and for major CEUS pattern identification was evaluated.RESULTS CEUS LR-5 predicted HCC with a 67.6%sensitivity,97.7%specificity,and 99.3%PPV(P<0.001).The merging of LR-4 and 5 offered an improved 93.9%sensitivity in HCC diagnosis with a 94.3%specificity and 98.8%PPV(P<0.001).CEUS LR-M predicted ICC with a 91.3%sensitivity,96.7%specificity,and 99.6%NPV(P<0.001).CEUS LR-3 predominantly included benign lesions(only 28.8%of malignancies).In this class,the hypo-hypo pattern showed a much higher rate of malignant lesions(73.3%)than the iso-iso pattern(2.6%).Inter-rater agreement between internal raters for CEUS-LR class assignment was almost perfect(n=511,k=0.94,P<0.001),while the agreement among raters from separate centres was substantial(n=50,k=0.67,P<0.001).Agreement was stronger for arterial phase hyperenhancement(internal k=0.86,P<2.7×10-214;external k=0.8,P<0.001)than washout(internal k=0.79,P<1.6×10-202;external k=0.71,P<0.001).CONCLUSION CEUS LI-RADS is effective but can be improved by merging LR-4 and 5 to diagnose HCC and by splitting LR-3 into two subgroups to differentiate iso-iso nodules from other patterns. 展开更多
关键词 Contrast-enhanced ultrasound Liver Imaging reporting and data system Hepatocellular carcinoma Intrahepatic cholangiocarcinoma CIRRHOSIS Contrast-enhanced ultrasound LIVER
下载PDF
Interobserver agreement for contrast-enhanced ultrasound of liver imaging reporting and data system:A systematic review and metaanalysis 被引量:2
5
作者 Jun Li Ming Chen +7 位作者 Zi-Jing Wang Shu-Gang Li Meng Jiang Long Shi Chun-Li Cao Tian Sang Xin-Wu Cui Christoph F Dietrich 《World Journal of Clinical Cases》 SCIE 2020年第22期5589-5602,共14页
BACKGROUND Hepatocellular carcinoma is the most common primary liver malignancy.From the results of previous studies,Liver Imaging Reporting and Data System(LIRADS)on contrast-enhanced ultrasound(CEUS)has shown satisf... BACKGROUND Hepatocellular carcinoma is the most common primary liver malignancy.From the results of previous studies,Liver Imaging Reporting and Data System(LIRADS)on contrast-enhanced ultrasound(CEUS)has shown satisfactory diagnostic value.However,a unified conclusion on the interobserver stability of this innovative ultrasound imaging has not been determined.The present metaanalysis examined the interobserver agreement of CEUS LI-RADS to provide some reference for subsequent related research.AIM To evaluate the interobserver agreement of LI-RADS on CEUS and analyze the sources of heterogeneity between studies.METHODS Relevant papers on the subject of interobserver agreement on CEUS LI-RADS published before March 1,2020 in China and other countries were analyzed.The studies were filtered,and the diagnostic criteria were evaluated.The selected references were analyzed using the“meta”and“metafor”packages of R software version 3.6.2.RESULTS Eight studies were ultimately included in the present analysis.Meta-analysis results revealed that the summary Kappa value of included studies was 0.76[95%confidence interval,0.67-0.83],which shows substantial agreement.Higgins I2 statistics also confirmed the substantial heterogeneity(I2=91.30%,95%confidence interval,85.3%-94.9%,P<0.01).Meta-regression identified the variables,including the method of patient enrollment,method of consistency testing,and patient race,which explained the substantial study heterogeneity.CONCLUSION CEUS LI-RADS demonstrated overall substantial interobserver agreement,but heterogeneous results between studies were also obvious.Further clinical investigations should consider a modified recommendation about the experimental design. 展开更多
关键词 Contrast-enhanced ultrasound Liver imaging reporting and data system Interobserver agreement systematic review DIAGNOSIS META-ANALYSIS
下载PDF
Effect of training on resident inter-reader agreement with American College of Radiology Thyroid Imaging Reporting and Data System
6
作者 Yang Du Meredith Bara +6 位作者 Prayash Katlariwala Roger Croutze Katrin Resch Jonathan Porter Medica Sam Mitchell P Wilson Gavin Low 《World Journal of Radiology》 2022年第1期19-29,共11页
BACKGROUND The American College of Radiology Thyroid Imaging Reporting and Data System(ACR TI-RADS)was introduced to standardize the ultrasound characterization of thyroid nodules.Studies have shown that ACR-TIRADS re... BACKGROUND The American College of Radiology Thyroid Imaging Reporting and Data System(ACR TI-RADS)was introduced to standardize the ultrasound characterization of thyroid nodules.Studies have shown that ACR-TIRADS reduces unnecessary biopsies and improves consistency of imaging recommendations.Despite its widespread adoption,there are few studies to date assessing the inter-reader agreement amongst radiology trainees with limited ultrasound experience.We hypothesize that in PGY-4 radiology residents with no prior exposure to ACR TIRADS,a statistically significant improvement in inter-reader reliability can be achieved with a one hour training session.AIM To evaluate the inter-reader agreement of radiology residents in using ACR TIRADS before and after training.METHODS A single center retrospective cohort study evaluating 50 thyroid nodules in 40 patients of varying TI-RADS levels was performed.Reference standard TI-RADS scores were established through a consensus panel of three fellowship-trained staff radiologists with between 1 and 14 years of clinical experience each.Three PGY-4 radiology residents(trainees)were selected as blinded readers for this study.Each trainee had between 4 to 5 mo of designated ultrasound training.No trainee had received specialized TI-RADS training prior to this study.Each of the readers independently reviewed the 50 testing cases and assigned a TI-RADS score to each case before and after TI-RADS training performed 6 wk apart.Fleiss kappa was used to measure the pooled inter-reader agreement.The relative diagnostic performance of readers,pre-and post-training,when compared against the reference standard.RESULTS There were 33 females and 7 males with a mean age of 56.6±13.6 years.The mean nodule size was 19±14 mm(range from 5 to 63 mm).A statistically significant superior inter-reader agreement was found on the post-training assessment compared to the pre-training assessment for the following variables:1.“Shape”(k of 0.09[slight]pre-training vs 0.67[substantial]post-training,P<0.001),2.“Echogenic foci”(k of 0.28[fair]pre-training vs 0.45[moderate]post-training,P=0.004),3.‘TI-RADS level’(k of 0.14[slight]pre-training vs 0.36[fair]post-training,P<0.001)and 4.‘Recommendations’(k of 0.36[fair]pre-training vs 0.50[moderate]post-training,P=0.02).No significant differences between the preand post-training assessments were found for the variables'composition','echogenicity'and'margins'.There was a general trend towards improved pooled sensitivity with TI-RADS levels 1 to 4 for the post-training assessment while the pooled specificity was relatively high(76.6%-96.8%)for all TI-RADS level.CONCLUSION Statistically significant improvement in inter-reader agreement in the assigning TI-RADS level and recommendations after training is observed.Our study supports the use of dedicated ACR TI-RADS training in radiology residents. 展开更多
关键词 thyroid thyroid nodule American College of Radiology thyroid Imaging reporting and data system Inter-reader agreement ultrasound
下载PDF
BRAF^(V600E) vs. TIRADS in predicting papillary thyroid cancers in Bethesda system Ⅰ, Ⅲ, and Ⅴ nodules 被引量:11
7
作者 Ya Wu Ting Xu +8 位作者 Xingyue Cao Xin Zhao Hongyan Deng Jianxiang Wang Xiao Li Qing Yao Xinhua Ye Meiping Shen Xiaohong Wu 《Cancer Biology & Medicine》 SCIE CAS CSCD 2019年第1期131-138,共8页
Objective: Bethesda System for Reporting Thyroid Cytopathology(BSRTC) categories Ⅰ, Ⅲ, and Ⅴaccount for a significant proportion of fine needle aspiration cytology(FNAC) diagnoses. This study aimed to compare the d... Objective: Bethesda System for Reporting Thyroid Cytopathology(BSRTC) categories Ⅰ, Ⅲ, and Ⅴaccount for a significant proportion of fine needle aspiration cytology(FNAC) diagnoses. This study aimed to compare the diagnostic efficacy of BRAF^(V600E) mutation and the Thyroid Imaging Reporting and Data System(TIRADS) classification in differentiating papillary thyroid cancers(PTCs) from benign lesions among BSRTC I, III, and V nodules.Methods: A total of 472 patients with 479 nodules were enrolled in this prospective study. Ultrasound, BRAF^(V600E) mutation testing, and FNAC were performed in each nodule, followed by surgery or regular ultrasound examination.Results: In the BSRTC I category, BRAF^(V600E) showed similar sensitivity, higher specificity, and lower accuracy when compared with TIRADS. In the BSRTC III/V category, the sensitivity, specificity, and accuracy of BRAF^(V600E) were similar to those of TIRADS. In comparison to BRAF^(V600E) alone, the combination of the two methods significantly improved sensitivity(BSRTC Ⅰ:93.6% vs. 67.7%, P < 0.01; BSRTC Ⅲ: 93.8% vs. 75.0%, P < 0.01; BSRTC V: 96.0% vs. 85.3%, P < 0.001). When compared with TIRADS alone, the combination improved sensitivity in BSRTC Ⅰ nodules(93.6% vs. 74.2%, P < 0.05), increased sensitivity and decreased accuracy in BSRTC III nodules(93.8% vs. 75.0%, P < 0.01, 91.0% vs. 93.6%, P < 0.01), and improved both sensitivity and accuracy in BSRTC V nodules(96.0% vs. 82.0%, P < 0.001; 94.2% vs. 81.3%, P < 0.001).Conclusions: BRAF^(V600E) exhibited higher specificity and lower accuracy compared with TIRADS in BSRTC Ⅰ nodules, while the two methods showed similar diagnostic value in BSRTC Ⅲ/Ⅴ nodules. The combination of the two methods distinctly improved sensitivity in the diagnosis of PTCs in BSRTC Ⅰ, Ⅲ, and Ⅴ nodules. 展开更多
关键词 PAPILLARY thyroid carcinoma FINE-NEEDLE aspiration cytology(FNAC) BRAFV600E thyroid imaging reporting and data system(TIRADS) BETHESDA classification
下载PDF
Contrast-enhanced ultrasound in association with serum biomarkers for differentiating combined hepatocellular-cholangiocarcinoma from hepatocellular carcinoma and intrahepatic cholangiocarcinoma 被引量:14
8
作者 Jie Yang Ya-han Zhang +5 位作者 Jia-Wu Li Ying-Yu Shi Jia-Yan Huang Yan Luo Ji-Bin Liu Qiang Lu 《World Journal of Gastroenterology》 SCIE CAS 2020年第46期7325-7337,共13页
BACKGROUND Combined hepatocellular-cholangiocarcinoma(CHC)is a rare type of primary liver cancer.Due to its complex histopathological characteristics,the imaging features of CHC can overlap with those of hepatocellula... BACKGROUND Combined hepatocellular-cholangiocarcinoma(CHC)is a rare type of primary liver cancer.Due to its complex histopathological characteristics,the imaging features of CHC can overlap with those of hepatocellular carcinoma(HCC)and intrahepatic cholangiocarcinoma(ICC).AIM To investigate the possibility and efficacy of differentiating CHC from HCC and ICC by using contrast-enhanced ultrasound(CEUS)Liver Imaging Reporting and Data System(LI-RADS)and tumor biomarkers.METHODS Between January 2016 and December 2019,patients with histologically confirmed CHC,ICC and HCC with chronic liver disease were enrolled.The diagnostic formula for CHC was as follows:(1)LR-5 or LR-M with elevated alphafetoprotein(AFP)and carbohydrate antigen 19-9(CA19-9);(2)LR-M with elevated AFP and normal CA19-9;or(3)LR-5 with elevated CA19-9 and normal AFP.The sensitivity,specificity,accuracy and area under the receiver operating characteristic curve were calculated to determine the diagnostic value of the criteria.RESULTS After propensity score matching,134 patients(mean age of 51.4±9.4 years,108 men)were enrolled,including 35 CHC,29 ICC and 70 HCC patients.Based on CEUS LI-RADS classification,74.3%(26/35)and 25.7%(9/35)of CHC lesions were assessed as LR-M and LR-5,respectively.The rates of elevated AFP and CA19-9 in CHC patients were 51.4%and 11.4%,respectively,and simultaneous elevations of AFP and CA19-9 were found in 8.6%(3/35)of CHC patients.The sensitivity,specificity,positive predictive value,negative predictive value,accuracy and area under the receiver operating characteristic curve of the aforementioned diagnostic criteria for discriminating CHC from HCC and ICC were 40.0%,89.9%,58.3%,80.9%,76.9%and 0.649,respectively.When considering the reported prevalence of CHC(0.4%-14.2%),the positive predictive value and NPV were revised to 1.6%-39.6%and 90.1%-99.7%,respectively.CONCLUSION CHCs are more likely to be classified as LR-M than LR-5 by CEUS LI-RADS.The combination of the CEUS LI-RADS classification with serum tumor markers shows high specificity but low sensitivity for the diagnosis of CHC.Moreover,CHC could be confidently excluded with high NPV. 展开更多
关键词 Combined hepatocellular-cholangiocarcinoma Contrast-enhanced ultrasound Liver imaging reporting and data system Sensitivity Diagnosis Liver neoplasms
下载PDF
Electronic Synoptic Reporting of Thyroid Nodules: Potential for Reduction in Number of Patients Undergoing Thyroid Nodule Biopsies 被引量:2
9
作者 Jimmy Tanche Wang Paul Babyn +1 位作者 Gary Groot Rob Otani 《Open Journal of Radiology》 2016年第3期233-242,共11页
Purpose: The objective of the study was to design and implement an electronic synoptic report for thyroid sonography that incorporates the thyroid imaging reporting and data system (TIRADS) and assess potential for re... Purpose: The objective of the study was to design and implement an electronic synoptic report for thyroid sonography that incorporates the thyroid imaging reporting and data system (TIRADS) and assess potential for reducing unnecessary fine needle aspiration biopsies (FNAB) of thyroid nodules. Methods: The electronic synoptic report was developed using a relational database based on elements from TIRADS and a multidisciplinary consensus statement for thyroid reporting. A retrospective analysis of 138 patients with previously reported thyroid sonographic exams was evaluated for the presence of these elements. The electronic synoptic report calculates the TIRADS score and generates a formal report. Using the TIRADS score the potential decrease in unnecessary FNAB was estimated. Results: Key TIRADS elements were variously reported ranging from 43% for the thyroid nodule’s architecture as solid or cystic. Thyroid nodule echogenicity and calcification was commented in 27% and 23%, respectively. Other features of the TIRADS score were commented in 0% to 8% of the official reports. Estimated reduction for potentially reduced need for FNAB was 34.5%. Conclusions: This study is the first implementation of synoptic reporting using a relational database for sonography of thyroid nodules. Implementation of an electronic standardized synoptic reporting system may facilitate more accurate, and more comprehensive reporting for thyroid ultrasound scanning of thyroid nodules. The use of TIRADS was estimated to be able to potentially reduce the need for FNAB which was significant. 展开更多
关键词 Synoptic reporting thyroid Nodules thyroid Cancer Fine Needle Aspiration Biopsy thyroid Imaging reporting and data system
下载PDF
Can contrast enhanced ultrasound differentiate intrahepatic cholangiocarcinoma from hepatocellular carcinoma? 被引量:11
10
作者 Jia-Yan Huang Jia-Wu Li +4 位作者 Wen-Wu Ling Tao Li Yan Luo Ji-Bin Liu Qiang Lu 《World Journal of Gastroenterology》 SCIE CAS 2020年第27期3938-3951,共14页
BACKGROUND Hepatocellular carcinoma(HCC)and intrahepatic cholangiocarcinoma(ICC)differ in treatment and prognosis,warranting an effective differential diagnosis between them.The LR-M category in the contrast-enhanced ... BACKGROUND Hepatocellular carcinoma(HCC)and intrahepatic cholangiocarcinoma(ICC)differ in treatment and prognosis,warranting an effective differential diagnosis between them.The LR-M category in the contrast-enhanced ultrasound(CEUS)liver imaging reporting and data system(LI-RADS)was set up for lesions that are malignant but not specific to HCC.However,a substantial number of HCC cases in this category elevated the diagnostic challenge.AIM To investigate the possibility and efficacy of differentiating ICC from HCC classified in the LR-M category according to the CEUS LI-RADS.METHODS Patients with complete CEUS records together with pathologically confirmed ICC and LR-M HCC(HCC classified in the CEUS LI-RADS LR-M category)between January 2015 and October 2018 were included in this retrospective study.Each ICC was assigned a category as per the CEUS LI-RADS.The enhancement pattern,washout timing,and washout degree between the ICC and LR-M HCC were compared using theχ2 test.Logistic regression analysis was used for prediction of ICC.Receiver operating characteristic(ROC)curve analysis was used to investigate the possibility of LR-M criteria and serum tumor markers in differentiating ICC from LR-M HCC.RESULTS A total of 228 nodules(99 ICCs and 129 LR-M HCCs)in 228 patients were included.The mean sizes of ICC and LR-M HCC were 6.3±2.8 cm and 5.5±3.5 cm,respectively(P=0.03).Peripheral rim-like arterial phase hyperenhancement(APHE)was detected in 50.5%(50/99)of ICCs vs 16.3%(21/129)of LR-M HCCs(P<0.001).Early washout was found in 93.4%(93/99)of ICCs vs 96.1%(124/129)of LR-M HCCs(P>0.05).Marked washout was observed in 23.2%(23/99)of ICCs and 7.8%(10/129)of LR-M HCCs(P=0.002),while this feature did not show up alone either in ICC or LR-M HCC.Homogeneous hyperenhancement was detected in 15.2%(15/99)of ICCs and 37.2%(48/129)of LR-M HCCs(P<0.001).The logistic regression showed that rim APHE,carbohydrate antigen 19-9(CA 19-9),and alpha fetoprotein(AFP)had significant correlations with ICC(r=1.251,3.074,and-2.767,respectively;P<0.01).Rim APHE presented the best enhancement pattern for diagnosing ICC,with an area under the ROC curve(AUC)of 0.70,sensitivity of 70.4%,and specificity of 68.8%.When rim hyperenhancement was coupled with elevated CA 19-9 and normal AFP,the AUC and sensitivity improved to 0.82 and 100%,respectively,with specificity decreasing to 63.9%.CONCLUSION Rim APHE is a key predictor for differentiating ICC from LR-M HCC.Rim APHE plus elevated CA 19-9 and normal AFP is a strong predictor of ICC rather than LR-M HCC.Early washout and marked washout have limited value for the differentiation between the two entities. 展开更多
关键词 DIAGNOSIS Contrast enhanced ultrasound Hepatocellular carcinoma Intrahepatic cholangiocarcinoma Liver imaging reporting and data system
下载PDF
Novel model combining contrast-enhanced ultrasound with serology predicts hepatocellular carcinoma recurrence after hepatectomy 被引量:5
11
作者 Hai-Bin Tu Li-Hong Chen +3 位作者 Yu-Jie Huang Si-Yi Feng Jian-Ling Lin Yong-Yi Zeng 《World Journal of Clinical Cases》 SCIE 2021年第24期7009-7021,共13页
BACKGROUND Surgery is the primary curative option in patients with hepatocellular carcinoma(HCC).However,recurrence within 2 years is observed in 30%–50%of patients,being a major cause of mortality.AIM To construct a... BACKGROUND Surgery is the primary curative option in patients with hepatocellular carcinoma(HCC).However,recurrence within 2 years is observed in 30%–50%of patients,being a major cause of mortality.AIM To construct and verify a non-invasive prediction model combining contrastenhanced ultrasound(CEUS)with serology biomarkers to predict the early recurrence of HCC.METHODS Records of 744 consecutive patients undergoing first-line curative surgery for HCC in one institution from 2016–2018 were reviewed,and 292 local patients were selected for analysis.General characteristics including gender and age,CEUS liver imaging reporting and data system(LIRADS)parameters including wash-in time,wash-in type,wash-out time,and wash-out type,and serology biomarkers including alanine aminotransferase,aspartate aminotransferase,platelets,and alpha-fetoprotein(AFP)were collected.Univariate analysis and multivariate Cox proportional hazards regression model were used to evaluate the independent prognostic factors for tumor recurrence.Then a nomogram called CEUS model was constructed.The CEUS model was then used to predict recurrence at 6 mo,12 mo,and 24 mo,the cut-off value was calculate by X-tile,and each C-index was calculated.Then Kaplan-Meier curve was compared by logrank test.The calibration curves of each time were depicted.RESULTS A nomogram predicting early recurrence(ER),named CEUS model,was formulated based on the results of the multivariate Cox regression analysis.This nomogram incorporated tumor diameter,preoperative AFP level,and LIRADS,and the hazard ratio was 1.123(95%confidence interval[CI]:1.041-1.211),1.547(95%CI:1.245-1.922),and 1.428(95%CI:1.059-1.925),respectively.The cut-off value at 6 mo,12 mo,and 24 mo was 100,80,and 50,and the C-index was 0.748(95%CI:0.683-0.813),0.762(95%CI:0.704-0.820),and 0.762(95%CI:0.706-0.819),respectively.The model showed satisfactory results,and the calibration at 6 mo was desirable;however,the calibration at 12 and 24 mo should be improved.CONCLUSION The CEUS model enables the well-calibrated individualized prediction of ER before surgery and may represent a novel tool for biomarker research and individual counseling. 展开更多
关键词 Hepatocellular carcinoma RECURRENCE Prediction Contrast-enhanced ultrasound Liver imaging reporting and data system ALPHA-FETOPROTEIN
下载PDF
Differentiating malignant and benign focal liver lesions in children using CEUS LI-RADS combined with serum alpha-fetoprotein 被引量:2
12
作者 Zhen-Peng Jiang Ke-Yu Zeng +6 位作者 Jia-Yan Huang Jie Yang Rui Yang Jia-Wu Li Ting-Ting Qiu Yan Luo Qiang Lu 《World Journal of Gastroenterology》 SCIE CAS 2022年第21期2350-2360,共11页
BACKGROUND Contrast-enhanced ultrasound(CEUS)can be used to diagnose focal liver lesions(FLLs)in children.The America College of Radiology developed the CEUS liver imaging reporting and data system(LI-RADS)for standar... BACKGROUND Contrast-enhanced ultrasound(CEUS)can be used to diagnose focal liver lesions(FLLs)in children.The America College of Radiology developed the CEUS liver imaging reporting and data system(LI-RADS)for standardizing CEUS diagnosis of FLLs in adult patients.Until now,no similar consensus or guidelines have existed for pediatric patients to improve imaging interpretation as adults.AIM To evaluate the performance of CEUS LI-RADS combined with alpha-fetoprotein(AFP)in differentiating benign and malignant FLLs in pediatric patients.METHODS Between January 2011 and January 2021,patients≤18 years old who underwent CEUS for FLLs were retrospectively evaluated.The following criteria for diagnosing malignancy were proposed:Criterion I considered LR-4,LR-5,or LRM lesions as malignancies;criterion II regarded LR-4,LR-5 or LR-M lesions with simultaneously elevated AFP(≥20 ng/mL)as malignancies;criterion III took LR-4 Lesions with elevated AFP or LR-5 or LR-M lesions as malignancies.The sensitivity,specificity,accuracy and area under the receiver operating characteristic curve(AUC)were calculated to determine the diagnostic value of the aforementioned criteria.RESULTS The study included 63 nodules in 60 patients(mean age,11.0±5.2 years;26 male).There were no statistically significant differences between the specificity,accuracy,or AUC of criterion II and criterion III(95.1%vs 80.5%,84.1%vs 87.3%,and 0.794 vs 0.902;all P>0.017).Notably,criterion III showed a higher diagnostic sensitivity than criterion II(100%vs 63.6%;P<0.017).However,both the specificity and accuracy of criterion I was inferior to those of criterion II and criterion III(all P<0.017).For pediatric patients more than 5 years old,the performance of the three criteria was overall similar when patients were subcategorized by age when compared to all patients in aggregate.CONCLUSION CEUS LI-RADS combined with AFP may be a powerful diagnostic tool in pediatric patients.LR-4 with elevated AFP,LR-5 or LR-M lesions is highly suggestive of malignant tumors. 展开更多
关键词 Pediatric Contrast-enhanced ultrasound Liver imaging reporting and data system Diagnosis Focal liver lesions ALPHA-FETOPROTEIN
下载PDF
The Role of a Pre-Fine Needle Aspiration Clinic in Improving the Quality of Thyroid Nodule Investigation in Saskatchewan
13
作者 Paige Baldwin Terra Arnason +2 位作者 Niomi Singh Robert Otani Gary Groot 《Open Journal of Radiology》 2020年第1期23-34,共12页
Background: The Canadian province of Saskatchewan introduced a pre-fine needle aspiration (FNA) clinic to review adherence of referrals for thyroid biopsy based on the guidelines of the American College of Radiology’... Background: The Canadian province of Saskatchewan introduced a pre-fine needle aspiration (FNA) clinic to review adherence of referrals for thyroid biopsy based on the guidelines of the American College of Radiology’s (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS) scoring system. The intention is to minimize low-yield biopsy rates by improving the quality of thyroid nodule investigation in Saskatchewan through this clinic. TI-RADS is a malignancy risk scoring system for thyroid nodules based on five sonographic characteristics: composition, echogenicity, shape, margin, and echogenic foci (calcium). Recommendations for intervention or clinical follow-up are further determined by the size of the nodule. Methods: Through a retrospective chart review of all thyroid biopsy referrals to the Royal University Hospital (RUH) in Saskatchewan between 22 March 2016 and 17 May 2018, the impact of the multidisciplinary pre-FNA clinic on appropriate thyroid biopsies in Saskatchewan was evaluated. Results: This study evaluated 252 referrals, 203 of which underwent FNA and 23 which received surgical biopsy. TI-RADS scores appended to thyroid biopsy referrals increased upon pre-FNA clinic initiation, yet score quality did not improve. Rates of malignant biopsies were lower than ACR-reporting suggesting inappropriate biopsy of low risk nodules perhaps by overcalling the TI-RADS score. The majority of FNA cytology matched final surgical pathology, with 78% of indeterminate FNAs being malignant, and all non-diagnostic FNAs being benign. Conclusions: The implementation of the pre-FNA clinic reduced the number of thyroid biopsies in Saskatchewan by 11% overall. 展开更多
关键词 thyroid NODULES thyroid Cancer Fine Needle ASPIRATION BIOPSY thyroid Imaging reporting and data system (TIRADS)
下载PDF
Imaging related to underlying immunological and pathological processes in COVID-19
14
作者 Elena Ilieva Alexandra Boyapati +4 位作者 Lyubomir Chervenkov Milena Gulinac Jordan Borisov Kamelia Genova Tsvetelina Velikova 《World Journal of Clinical Infectious Diseases》 2022年第1期1-19,共19页
The introduction of coronavirus disease-2019(COVID-19)as a global pandemic has contributed to overall morbidity and mortality.With a focus on understanding the immunology and pathophysiology of the disease,these featu... The introduction of coronavirus disease-2019(COVID-19)as a global pandemic has contributed to overall morbidity and mortality.With a focus on understanding the immunology and pathophysiology of the disease,these features can be linked with the respective findings of imaging studies.Thus,the constellation between clinical presentation,histological,laboratory,immunological,and imaging results is crucial for the proper management of patients.The purpose of this article is to examine the role of imaging during the particular stages of severe acute respiratory syndrome coronavirus 2 infection–asymptomatic stage,typical and atypical COVID-19 pneumonia,acute respiratory distress syndrome,multiorgan failure,and thrombosis.The use of imaging methods to assess the severity and duration of changes is crucial in patients with COVID-19.Radiography and computed tomography are among the methods that allow accurate characterization of changes. 展开更多
关键词 Coronavirus disease-2019 ultrasound Computed tomography Magnetic resonance imaging Ground-glass opacity Acute respiratory distress syndrome Cytokine storm COVID-19 reporting and data system High-resolution computed tomography Severe acute respiratory syndrome coronavirus 2
下载PDF
超声C-TIRADS联合血清miR-107检测对甲状腺结节性质的诊断价值
15
作者 张媛 鲍应军 +3 位作者 葛妍 武秀兰 张连花 张芬 《中国实验诊断学》 2024年第9期1030-1035,共6页
目的探讨超声甲状腺影像报告和数据系统(C-TIRADS)联合血清微小RNA-107(miR-107)检测对甲状腺结节性质的诊断价值。方法选取2022年4月至2024年1月新疆医科大学附属肿瘤医院患甲状腺结节的患者98例(共113个结节)作为研究对象,均进行C-TIR... 目的探讨超声甲状腺影像报告和数据系统(C-TIRADS)联合血清微小RNA-107(miR-107)检测对甲状腺结节性质的诊断价值。方法选取2022年4月至2024年1月新疆医科大学附属肿瘤医院患甲状腺结节的患者98例(共113个结节)作为研究对象,均进行C-TIRADS分类,并检测血清miR-107水平。根据手术病理是否出现恶性结节分恶性组、良性组。分析超声C-TIRADS分类、血清miR-107水平与甲状腺结节良恶性的关系及其对甲状腺结节的诊断价值,并进行校准曲线分析。结果98例甲状腺结节患者(113个结节)中有83个良性结节,包括结节性甲状腺肿49个、甲状腺腺瘤24个、桥本甲状腺炎10个,其余30个恶性结节均为甲状腺乳头状癌。恶性结节均位于包膜下,结节内部钙化,C-TIRADS分类为4b或4c。恶性组患者血清miR-107水平高于良性组(P<0.05)。行Logistic多因素回归分析结果显示结节位置位于包膜下、结节内部钙化、C-TIRADS分类为4b或4c、miR-107是恶性甲状腺结节的独立危险因素(P<0.05)。超声C-TIRADS联合血清miR-107水平诊断甲状腺结节性质的曲线下面积(AUC)值为0.907,大于二者单独诊断甲状腺结节性质的AUC值(0.702和0.835)(Z=3.300,P=0.001;Z=2.410,P=0.016)。超声C-TIRADS联合血清miR-107水平诊断甲状腺结节性质的预测值与真实值一致性较好,Brier得分为0.114,校准斜率为0.809,校准度良好。结论超声C-TIRADS联合血清miR-107水平在诊断甲状腺结节性质方面具有较高临床应用价值。 展开更多
关键词 超声甲状腺影像报告和数据系统 微小RNA-107 甲状腺结节 血清
下载PDF
2 cm以上的C-TI-RADS 3类甲状腺结节的临床特点分析
16
作者 唐艺峰 王龙龙 +4 位作者 刘益豪 张逸菲 李红强 马润声 殷德涛 《西安交通大学学报(医学版)》 CSCD 北大核心 2024年第1期74-79,共6页
目的统计2 cm以上的中国版甲状腺影像报告及数据系统(C-TI-RADS)3类甲状腺结节的临床特点,并探究其与性别、结节成分、对侧是否有癌、是否弥漫性回声改变、甲状腺过氧化物酶抗体(thyroid peroxidase antibody,TPOAB)、甲状腺球蛋白抗体(... 目的统计2 cm以上的中国版甲状腺影像报告及数据系统(C-TI-RADS)3类甲状腺结节的临床特点,并探究其与性别、结节成分、对侧是否有癌、是否弥漫性回声改变、甲状腺过氧化物酶抗体(thyroid peroxidase antibody,TPOAB)、甲状腺球蛋白抗体(anti-thyroglobulin antibodies,TGAB)等的相关性。方法回顾性分析2022年9月-2023年3月我科收治的甲状腺超声C-TI-RADS 3类且最大直径≥2 cm的94例甲状腺结节患者(均接受细胞病理和/或组织病理检查)的临床病理学信息。统计TBSⅠ类、良性、低风险肿瘤、恶性的比例,并比较性别、结节成分、对侧是否有癌、是否弥漫性回声改变、TPOAB、TGAB等临床特点在良性、低风险肿瘤、恶性三组中的比例有无统计学差异。结果排除7例TBSⅠ类患者,87例结节病理明确患者中,良性72例(细胞学38例、组织学34例)、低风险肿瘤5例(细胞学2例、组织学3例)、恶性10例(PTC 8例、FTC 1例、MTC 1例)。不同病理类型之间,结节成分(囊实性/实性)组间差异具有显著性,差异有统计学意义(χ^(2)=10.369,P=0.006);性别、是否弥漫性回声改变、对侧是否有癌、TPOAB、TGAB组间差异无统计学意义(P均>0.05)。进一步分析结节成分与病理类型的关系,结果表明,低风险肿瘤相对于良性结节实性比例更高,差异有统计学意义(χ^(2)=9.571,P=0.002);而恶性结节相对于低风险肿瘤(χ^(2)=2.143,P=0.143),恶性结节相对于良性结节(χ^(2)=2.165,P=0.141)囊实性比例差异均无统计学意义。结论虽然各种版本的甲状腺影像报告与数据系统均将TI-RADS 3级结节认定为良性可能,但恶性结节在C-TI-RADS 3类甲状腺结节中仍占一定比例,需要重视诸如囊实性结节、甲状腺滤泡性肿瘤、甲状腺髓样癌等超声征象不典型的甲状腺结节。在评估结节良恶性时,超声引导下细针穿刺细胞病理学检查是必要的,需要重视标本不满意或无法诊断的情况,提高诊断的准确性。 展开更多
关键词 中国版甲状腺影像报告及数据系统(C-TI-RADS)3类 甲状腺结节 临床特点
下载PDF
基于临床与超声特征构建的列线图模型在超声医师修饰甲状腺中国(超声)甲状腺影像报告和数据系统分类结果中的应用价值
17
作者 赵银花 梁羽 +4 位作者 王蕴晗 杨丽 胥桐 范尔兮 李璇 《实用临床医药杂志》 CAS 2024年第11期18-22,28,共6页
目的分析基于甲状腺临床与超声特征构建的列线图模型在超声医师修饰甲状腺中国(超声)甲状腺影像报告和数据系统(C-TI-RADS)分类结果中的应用价值。方法回顾性分析2021年1月—2022年12月四川省人民医院(训练集,n=841)以及四川绵阳四0四医... 目的分析基于甲状腺临床与超声特征构建的列线图模型在超声医师修饰甲状腺中国(超声)甲状腺影像报告和数据系统(C-TI-RADS)分类结果中的应用价值。方法回顾性分析2021年1月—2022年12月四川省人民医院(训练集,n=841)以及四川绵阳四0四医院(外部验证集,n=295)外科手术切除的甲状腺结节患者的临床病理及超声资料,并利用术前甲状腺超声进行甲状腺结节C-TI-RADS分类。通过单因素及多因素Logistic回归分析在训练集中筛选独立预测因子并构建列线图模型,通过Bootstrap重抽样进行内部验证;四川绵阳四0四医院超声医师根据构建的列线图模型进行外部验证。绘制受试者工作特征(ROC)曲线及校准曲线,评估模型效能及在超声医师修饰C-TI-RADS分类结果中的临床价值。结果单因素及多因素Logistic回归分析结果显示,性别、年龄、结节最大径、结节数目、颈部淋巴结超声异常和C-TI-RADS分类是预测超声医师修饰C-TI-RADS分类结果的独立因素(P<0.05)。基于上述因素构建的列线图模型的一致性指数为0.842(95%CI:0.816~0.867),曲线下面积(AUC)为0.842,基于最佳截断值的敏感度为92.9%,特异度为63.7%,准确率为75.9%。在训练集和外部验证集中,构建的列线图模型的预测结果与实际情况均具有较好的一致性。结论基于甲状腺临床与超声特征构建的列线图模型在超声医师修饰C-TI-RADS分类结果中显示出良好的预测准确性,具有潜在的临床应用价值。 展开更多
关键词 甲状腺结节 列线图 超声医师 中国(超声)甲状腺影像报告和数据系统 修饰 价值
下载PDF
深度学习联合C-TIRADS在甲状腺4a类结节风险分层管理的应用
18
作者 何美情 张均 +3 位作者 高燕华 张茜茜 韩磊 李艳川 《分子影像学杂志》 2024年第9期921-927,共7页
目的探讨深度学习联合中国超声甲状腺影像报告和数据系统(C-TIRADS)在甲状腺4a类结节风险分层管理的应用。方法纳入陕西省人民医院2018年12月~2022年10月收治的179例甲状腺结节患者,依据病理结果分为良性组(n=76)与恶性组(n=103),所有... 目的探讨深度学习联合中国超声甲状腺影像报告和数据系统(C-TIRADS)在甲状腺4a类结节风险分层管理的应用。方法纳入陕西省人民医院2018年12月~2022年10月收治的179例甲状腺结节患者,依据病理结果分为良性组(n=76)与恶性组(n=103),所有患者均予以超声检查,按照C-TIRADS指南标准、深度学习进行观察诊断。利用多因素Logistic回归分析获取独立预测指标;利用ROC曲线评估预测变量准确性。结果多因素Logistic分析显示,甲状腺结节图像特征的结构、方位、边缘、回声、局灶性强回声及年龄是独立预测甲状腺结节性质的指标(P<0.05)。以病理结果为金标准,深度学习联合C-TIRADS与病理结果完全符合率为96.65%,Kappa值为0.932,一致性好;联合诊断甲状腺4a类结节的符合率、特异度、阳性预测值显著高于深度学习、C-TIRADS(P<0.05)。联合诊断疾病的敏感度、阴性预测值高于深度学习(P<0.001),但与C-TIRADS的差异无统计学意义(P<0.05)。ROC曲线分析显示,C-TIRADS、深度学习及联合诊断的AUC分别为0.873、0.819、0.967;与Az=0.5相比,差异有统计学意义(P<0.001)。结论C-TIRADS在甲状腺4a类结节风险分层管理中敏感性较高,结合深度学习辅助诊断能够准确进行甲状腺结节良恶性鉴别,具备较高诊断效能。 展开更多
关键词 甲状腺结节 中国超声甲状腺影像报告和数据系统 深度学习 恶性风险 指南 诊断
下载PDF
C-TIRADS与ACR-TIRADS对甲状腺结节的诊断效能对比研究
19
作者 王欣 《中国实用医药》 2024年第22期21-25,共5页
目的 对比研究由中华医学会制定的中国甲状腺影像报告与数据系统(C-TIRADS)与美国放射学院制定的甲状腺影像报告与数据系统(ACR-TIRADS)对甲状腺结节的诊断效能。方法 回顾性分析经手术病理证实的511例(527个结节)甲状腺结节患者的超声... 目的 对比研究由中华医学会制定的中国甲状腺影像报告与数据系统(C-TIRADS)与美国放射学院制定的甲状腺影像报告与数据系统(ACR-TIRADS)对甲状腺结节的诊断效能。方法 回顾性分析经手术病理证实的511例(527个结节)甲状腺结节患者的超声图像,分别按照C-TIRADS、ACR-TIRADS标准进行分类。以病理结果作为金标准,计算各分类的恶性率,并与指南推荐恶性率进行对比;绘制受试者工作特征曲线(ROC曲线),计算曲线下面积(AUC)。根据约登指数确定分类的最佳截断值,根据最佳截断值评价两种TIRADS对甲状腺结节良恶性的敏感度、特异度、阳性预测值(PPV)和阴性预测值(NPV)。结果 病理结果显示,527个结节中,良性结节333个,其中结节性甲状腺肿311个,腺瘤12个,桥本甲状腺炎3个、亚急性甲状腺炎3个,单纯囊肿3个,肉芽肿结节1个;恶性结节194个,其中乳头状癌182个,滤泡癌8个,髓样癌2个,转移癌2个。以病理结果作为金标准,C-TIRADS 2、3、4A、4B、4C和5类的恶性率分别为0、1.97%、10.34%、46.58%、88.19%和91.67%;ACR-TIRADS 1、2、3、4和5类的恶性率分别为0、1.30%、3.73%、20.18%和83.42%。C-TIRADS各分类间恶性率对比,差异有统计学意义(P<0.05);ACR-TIRADS各分类间恶性率对比,差异有统计学意义(P<0.05)。除C-TIRADS 5类和ACR-TIRADS 3~5类恶性率高于指南推荐恶性率外,其余各分类实际恶性率低于指南推荐恶性率,或基本相符。C-TIRADS、ACR-TIRADS诊断甲状腺结节良恶性ROC曲线的AUC分别为0.865、0.864,AUC相当。C-TIRADS、ACR-TIRADS诊断甲状腺结节良恶性的最佳截断值分别为4B类、5类。C-TIRADS、ACR-TIRADS的敏感度、特异度、PPV、NPV分别为92.27%(179/194)、82.88%(276/333)、75.85%(179/236)、94.85%(276/291)和85.57%(166/194)、90.09%(300/333)、83.42%(166/199)、91.46%(300/328)。C-TIRADS的敏感度高于ACR-TIRADS,特异度低于ACR-TIRADS,差异有统计学意义(P<0.05);C-TIRADS的NPV略高于ACR-TIRADS,PPV略低于ACRTIRADS,差异均无统计学意义(P>0.05)。结论 C-TIRADS与ACR-TIRADS对甲状腺结节的良恶性鉴别诊断均具有较高的价值,诊断效能相当,但C-TIRADS较ACR-TIRADS更简便易行。 展开更多
关键词 中国甲状腺影像报告与数据系统 美国放射学院 超声图像 甲状腺结节 良恶性
下载PDF
C-TIRADS与K-TIRADS对甲状腺结节良恶性鉴别诊断的对比分析
20
作者 王欣 《影像研究与医学应用》 2024年第16期31-34,共4页
目的:对比分析中国甲状腺影像报告和数据系统(C-TIRADS)和韩国TIRADS(K-TIRADS)两种甲状腺影像报告与数据系统对甲状腺结节良恶性鉴别诊断的价值。方法:回顾性分析2017年3月—2023年3月在青岛大学附属泰安市中心医院经组织病理学证实的... 目的:对比分析中国甲状腺影像报告和数据系统(C-TIRADS)和韩国TIRADS(K-TIRADS)两种甲状腺影像报告与数据系统对甲状腺结节良恶性鉴别诊断的价值。方法:回顾性分析2017年3月—2023年3月在青岛大学附属泰安市中心医院经组织病理学证实的582个甲状腺结节的超声图像。分别按照C-TIRADS、K-TIRADS标准进行分类,以病理结果作为金标准,分析两种方法的诊断效能。结果:所得到的两种方法各分层的甲状腺结节的实际恶性率与指南所推荐的恶性率一致。C-TIRADS与K-TIRADS的AUC面积分别为0.899、0.897,两者比较差异无统计学意义(P>0.05)。C-TIRADS最佳截断值为4B类,K-TIRADS最佳截断值为5类。两者的灵敏度、特异度分别为0.925、0.872;0.818、0.889。结论:C-TIRADS与K-TIRADS对甲状腺结节的良恶性鉴别诊断均具有较高的价值,诊断效能相当,C-TIRADS更适合中国国情。 展开更多
关键词 超声检查 甲状腺结节 影像报告与数据系统
下载PDF
上一页 1 2 24 下一页 到第
使用帮助 返回顶部