期刊文献+
共找到142篇文章
< 1 2 8 >
每页显示 20 50 100
Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy
1
作者 Mitsuki Tomita Takeshi Ogura +5 位作者 Akitoshi Hakoda Saori Ueno Atsushi Okuda Nobu Nishioka Yoshitaro Yamamoto Hiroki Nishikawa 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第2期181-185,共5页
Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal... Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands. 展开更多
关键词 Endoscopic ultrasound-guided hepaticogastrostomy Endoscopic ultrasound-guided biliary drainage Endoscopic retrograde CHOLANGIOPANCREATOGRAPHY
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage
2
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 Endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Endoscopic ultrasound-guided tissue sampling induced pancreatic duct leak resolved by the placement of a pancreatic stent:A case report
3
作者 Ki-Hyun Kim Chang Hwan Park +1 位作者 Eunae Cho Yohan Lee 《World Journal of Clinical Cases》 SCIE 2024年第9期1677-1684,共8页
BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and... BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage. 展开更多
关键词 Endoscopic ultrasound-guided tissue sampling PANCREATITIS Pancreatic duct leak Pancreatic stent Case report
下载PDF
Percutaneous ultrasound-guided coaxial core needle biopsy for the diagnosis of multiple splenic lesions: A case report
4
作者 Sha-Hong Pu Wu-Yong-Ga Bao +2 位作者 Zhen-Peng Jiang Rui Yang Qiang Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期616-621,共6页
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide... BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue. 展开更多
关键词 SPLEEN Splenic disease Ultrasound BIOPSY ultrasound-guided coaxial core needle biopsy Case report
下载PDF
Endoscopic ultrasound-guided pancreatic fluid collection drainage: Where are we?
5
作者 Anupam Kumar Singh Manish Manrai Rakesh Kochhar 《World Journal of Gastrointestinal Endoscopy》 2024年第6期273-281,共9页
Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions... Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions includes percu-taneous,endoscopic,minimally invasive surgery,or a combined approach.Endoscopic drainage is the drainage of PFCs by creating an artificial communi-cation between the collection and gastrointestinal lumen that is maintained by placing a stent across the fistulous tract.In this editorial,we endeavored to update the current status of endoscopic ultrasound-guided drainage of PFCs. 展开更多
关键词 Pancreatic fluid collections Endoscopic ultrasound-guided drainage Endoscopic necrosectomy Lumen apposing metal stent Review
下载PDF
Endoscopic ultrasound-guided tissue acquisition for the diagnosis of focal liver lesion
6
作者 Alina Tantău Cosmina Sutac +1 位作者 Anamaria Pop Marcel Tantău 《World Journal of Radiology》 2024年第4期72-81,共10页
In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspirat... In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspiration(FNA)or more newly fine needle biopsy(FNB)is a well-developed technique in order to evaluate and differentiate the liver masses.The goal of the EUS-FNA or EUS-FNB is to provide an accurate sample for a histopathology examination.Therefore,malignant tumors such as hepatocarcinoma,cholangiocarcinoma and liver metastasis or benign tumors such as liver adenoma,focal hyperplastic nodular tumors and cystic lesions can be accurately diagnosed using EUS-guided tissue acquisition.EUS-FNB using 19 or 22 Ga needle provide longer samples and a higher diagnostic accuracy in patients with liver masses when compared with EUS-FNA.Few data are available on the diagnostic accuracy of EUS-FNB when compared with percutaneously,ultrasound,computer tomography or transjugulary-guided liver biopsies.This review will discuss the EUS-guided tissue acquisition options in patients with liver tumors and its efficacy and safety in providing accurate samples.The results of the last studies comparing EUS-guided liver biopsy with other conventional techniques are presented.The EUS-guided tissue acquisition using FNB can be a suitable technique in suspected liver lesions in order to provide an accurate histopathology diagnosis,especially for those who require endoscopy. 展开更多
关键词 Endoscopic ultrasound-guided liver biopsy Liver tissue acquisition Fine-needle aspiration Fine-needle biopsy Liver tumors Focal liver lesions
下载PDF
Endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction in Mexico
7
作者 Massiel Madelin Rosario-Morel Rodrigo Soto-Solis +5 位作者 Katia Picazo-Ferrera Miriam Idalia Torres-Ruiz JoséAlberto Estradas-Trujillo Mario Alberto Gallardo-Ramírez Gerardo Akram Darwich-del Moral Luis Ariel Waller-González 《World Journal of Surgical Procedures》 2024年第3期15-20,共6页
BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE ... BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE in patients with GOO.METHODS This study was a retrospective,observational,multicenter study in which the data from 10 patients who underwent EUS-GE due to GOO between September 2021 and May 2023 were collected.We analyzed technical success,clinical success,adverse events,and survival.Technical success was defined as adequate positioning and deployment of the stent.Clinical success was defined as the patient’s ability to tolerate oral intake without vomiting 7 d after the procedure.Postprocedural adverse events were recorded.RESULTS Eleven procedures in 10 patients with GOO were included.The mean age of the patients was 67.5 years(range:56-77 years).Malignant GOO was present in 9 patients.Technical success was achieved in 9/11 procedures(82%).Among them,clinical success was achieved in 9 patients(100%).Adverse events occurred in 1 patient(9%).The median survival was 3 months(n=7;range:1-8 months).CONCLUSION EUS-GE is a feasible therapeutic option in the treatment of GOO. 展开更多
关键词 Endoscopic ultrasound-guided gastroenterostomy Gastric outlet obstruction Lumen apposing metal stent Interventional endoscopic ultrasound GASTROJEJUNOSTOMY Duodenal stenting
下载PDF
Endoscopic ultrasound-guided biliary drainage:Are we there yet? 被引量:1
8
作者 Rishi Pawa Troy Pleasant +1 位作者 Chloe Tom Swati Pawa 《World Journal of Gastrointestinal Endoscopy》 2021年第8期302-318,共17页
Endoscopic retrograde cholangiopancreatography(ERCP)is the mainstay procedure of choice for management of obstructive biliary disease.While ERCP is widely performed with high success rates,the procedure is not feasibl... Endoscopic retrograde cholangiopancreatography(ERCP)is the mainstay procedure of choice for management of obstructive biliary disease.While ERCP is widely performed with high success rates,the procedure is not feasible in every patient such as cases of non-accessible papilla.In the setting of unsuccessful ERCP,endoscopic ultrasound-guided biliary drainage(EUS-BD)has become a promising alternative to surgical bypass and percutaneous biliary drainage(PTBD).A variety of different forms of EUS-BD have been described,allowing for both intrahepatic and extrahepatic approaches.Recent studies have reported high success rates utilizing EUS-BD for both transpapillary and transluminal drainage,with fewer adverse events when compared to PTBD.Advancements in novel technologies designed specifically for EUS-BD have led to increased success rates as well as improved safety profile for the procedure.The techniques of EUS-BD are yet to be fully standardized and are currently performed by highly trained advanced endoscopists.The aim of our review is to highlight the different EUSguided interventions for achieving biliary drainage and to both assess the progress that has been made in the field as well as consider what the future may hold. 展开更多
关键词 Endoscopic ultrasound-guided biliary drainage Endoscopic ultrasound-guided rendezvous Endoscopic ultrasound-guided choledochoduodenostomy Endoscopic ultrasound-guided hepaticogastrostomy Endoscopic ultrasound-guided gallbladder drainage Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography
下载PDF
Ultrasound-guided carotid angioplasty and stenting in a patient with iodinated contrast allergy:A case report 被引量:1
9
作者 Le Li Zi-Yan Wang Bo Liu 《World Journal of Clinical Cases》 SCIE 2023年第25期5926-5933,共8页
BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treati... BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treating carotid artery stenosis are drug treatment,carotid endarterectomy(CEA),carotid angioplasty and stenting(CAS).The approach is chosen based on the degree of stenosis.CEA or CAS could have been chosen for the current patient,who had severe carotid stenosis and an iodinated contrast allergy.After thoroughly communicating with the patient,the patient chose CAS for treatment.Therefore,we performed ultrasound-guided CAS to avoid the use of iodinated contrast.CASE SUMMARY The main symptoms of the patient were numbness and weakness of the left limb.Computed tomography angiography of the head and neck at another hospital indicated multiple sites of stenosis in the arteries of the head and neck.The patient requested CAS for treatment but was allergic to iodinated contrast media.Thus,routine digital subtraction angiography(DSA)with iodinated contrast could not be used for the procedure.The diagnosis of this patient was as follows:(1)Right parietal lobe cerebral infarction;(2)multiple sites of stenosis in the arteries of the head and neck(severe stenosis of the right internal carotid artery,severe stenosis of the right subclavian artery);(3)right subclavian steal syndrome;and(4)hypertension(stage 3,high risk).The interventions included routine treatment for cerebral infarction,oral administration of clopidogrel(75 mg qd)and aspirin(100 mg qd),ultrasound-guided CAS,and postoperative follow-up.Postoperative color Doppler ultrasound and cerebrovascular magnetic resonance angiography of the carotid artery showed good vascular recovery,and the postoperative follow-up indicated a good prognosis.CONCLUSION This case study suggests that ultrasound-guided endovascular treatment is a potential option for patients with contraindications to the iodinated contrast agents used in DSA-guided surgery,although excellent surgical operating skills are needed. 展开更多
关键词 Iodinated contrast allergy ultrasound-guideD Gadolinium-based contrast agent Carotid angioplasty and stenting Subclavian artery angioplasty and stenting Digital subtraction angiography Case report
下载PDF
Endoscopic ultrasound-guided biliary drainage-current status and future perspectives 被引量:2
10
作者 Petko Ivanov Karagyozov Ivan Tishkov +1 位作者 Irina Boeva Kiril Draganov 《World Journal of Gastrointestinal Endoscopy》 2021年第12期607-618,共12页
Endoscopic retrograde cholangiopancreatography(ERCP)with stenting is the treatment modality of choice for patients with benign and malignant bile duct obstruction.ERCP could fail in cases of duodenal obstruction,duode... Endoscopic retrograde cholangiopancreatography(ERCP)with stenting is the treatment modality of choice for patients with benign and malignant bile duct obstruction.ERCP could fail in cases of duodenal obstruction,duodenal diverticulum,ampullary neoplastic infiltration or surgically altered anatomy.In these cases percutaneous biliary drainage(PTBD)is traditionally used as a rescue procedure but is related to high morbidity and mortality and lower quality of life.Endoscopic ultrasound-guided biliary drainage(EUS-BD)is a relatively new interventional procedure that arose due to the development of curvilinear echoendoscope and the various endoscopic devices.A large amount of data is already collected that proves its efficacy,safety and ability to replace PTBD in cases of ERCP failure.It is also possible that EUS-BD could be chosen as a first-line treatment option in some clinical scenarios in the near future.Several EUS-BD techniques are developed EUS-guided transmural stenting,antegrade stenting and rendezvous technique and can be personalized depending on the individual anatomy.EUS-BD is normally performed in the same session from the same endoscopist in case of ERCP failure.The lack of training,absence of enough dedicated devices and lack of standardization still makes EUS-BD a difficult and not very popular procedure,which is related to life-threatening adverse events.Developing training models,dedicated devices and guidelines hopefully will make EUS-BD easier,safer and well accepted in the future.This paper focuses on the technical aspects of the different EUS-BD procedures,available literature data,advantages,negative aspects and the future perspectives of these modalities. 展开更多
关键词 Endoscopic ultrasound-guided biliary drainage Malignant bile duct obstruction Endoscopic ultrasound-guided hepaticogastrostomy Endoscopic ultrasoundguided rendezvous technique Endoscopic ultrasound-guided choledochoduodenostomy Endoscopic ultrasound-guided antegrade stenting Endoscopic retrograde cholangiopancreatography
下载PDF
The efficacy and safety of endoscopic ultrasound-guided fine-needle biopsy in gallbladder masses
11
作者 Ting Tong Li Tian +5 位作者 Min-Zi Deng Xue-Jie Chen Tian Fu Ke-Jia Ma Jia-Hao Xu Xiao-Yan Wang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2023年第6期632-638,共7页
Background: Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB) is a widely used modality for acquiring various target samples, but its efficacy in gallbladder masses is unknown. The aim of this retrospective stu... Background: Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB) is a widely used modality for acquiring various target samples, but its efficacy in gallbladder masses is unknown. The aim of this retrospective study was to evaluate the efficacy and safety of EUS-FNB in patients with gallbladder masses. Methods: The study samples were composed of patients from March 2015 to July 2019 who needed to identify the nature of gallbladder masses through EUS-FNB. The outcomes of this study were the adequacy of specimens, diagnostic yields, technical feasibility, and adverse events of the EUS-FNB in gallbladder masses. Results: A total of 27 consecutive patients with a median age of 58 years were included in this study. The 22-gauge FNB needle was feasible in all lesions. The median follow-up period of the patients was 294 days. The specimens sufficient for diagnosis account for 89%(24/27) and 93%(25/27) in cytology and histology, respectively. The overall diagnostic yields for malignancy showed the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.45% [95% confidence interval(CI): 75.12%-99.76%], 100%(95% CI: 46.29%-10 0%), 10 0%(95% CI: 80.76%-100%), 83.33%(95% CI: 36.48%-99.12%), and 96.30%(95% CI: 80.20%-99.99%), respectively. The subgroup analysis revealed that FNB could obtain sufficient specimens and high diagnostic yields in both gallbladder mass < 20.5 mm group and ≥20.5 mm group. One patient experienced mild abdominal pain after the procedure and recovered within one day. Conclusions: EUS-FNB is a reasonable diagnostic tool for the pretreatment diagnosis of patients with gallbladder masses, especially for patients who may miss the opportunity of surgery and need sufficient specimens to identify the pathological type so as to determine chemotherapy regimens. Further largescale studies are needed to confirm our conclusion. 展开更多
关键词 Adverse events Diagnostic yields Endoscopic ultrasound-guided fine-needle biopsy Gallbladder masses Specimen adequacy
下载PDF
Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages:A systematic review focusing on issues and rescue management
12
作者 Elia Armellini Flavio Metelli +4 位作者 Andrea Anderloni Anna Cominardi Giovanni Aragona Michele Marini FabioPace 《World Journal of Gastroenterology》 SCIE CAS 2023年第21期3341-3361,共21页
BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffus... BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffusion in different clinical settings.Nevertheless,the procedure may conceal unexpected pitfalls.LAMS misdeployment is the most frequent cause of technical failure and it can be considered a procedure-related adverse event when it hampers the conclusion of the planned procedure or results in significant clinical consequences.Stent misdeployment can be managed successfully by endoscopic rescue maneuvers to allow the completion of the procedure.To date,no standardized indication is available to guide an appropriate rescue strategy depending on the type of procedure or of misdeployment.AIM To evaluate the incidence of LAMS misdeployment during EUS-guided choledochoduodenostomy(EUS-CDS),gallbladder drainage(EUS-GBD)and pancreatic fluid collections drainage(EUS-PFC)and to describe the endoscopic rescue strategies adopted under the circumstance.METHODS We conducted a systematic review of the literature on PubMed by searching for studies published up to October 2022.The search was carried out using the exploded medical subject heading terms“lumen apposing metal stent”,“LAMS”,“endoscopic ultrasound”and“choledochoduodenostomy”or“gallbladder”or“pancreatic fluid collections”.We included in the review on-label EUS-guided procedures namely EUS-CDS,EUS-GBD and EUS-PFC.Only those publications reporting EUS-guided LAMS positioning were considered.The studies reporting a technical success rate of 100%and other procedure-related adverse events were considered to calculate the overall rate of LAMS misdeployment,while studies not reporting the causes of technical failure were excluded.Case reports were considered only for the extraction of data regarding the issues of misdeployment and rescue techniques.The following data were collected from each study:Author,year of publication,study design,study population,clinical indication,technical success,reported number of misdeployment,stent type and size,flange misdeployed and type of rescue strategy.RESULTS The overall technical success rate of EUS-CDS,EUS-GBD and EUS-PFC was 93.7%,96.1%,and 98.1%respectively.Significant rates of LAMS misdeployment have been reported for EUS-CDS,EUS-GBD and EUS-PFC drainage,respectively 5.8%,3.4%,and 2.0%.Endoscopic rescue treatment was feasible in 86.8%,80%,and 96.8%of cases.Non endoscopic rescue strategies were required only in 10.3%,16%and 3.2%for EUS-CDS,EUS-GBD,and EUS-PFC.The endoscopic rescue techniques described were over-the-wire deployment of a new stent through the created fistula tract in 44.1%,8%and 64.5%and stent-in-stent in 23.5%,60%,and 12.9%,respectively for EUSCDS,EUS-GBD,and EUS-PFC.Further therapeutic option were endoscopic rendezvous in 11.8%of EUS-CDS and repeated procedure of EUS-guided drainage in 16.1%of EUS-PFC.CONCLUSION LAMS misdeployment is a relatively common adverse event in EUS-guided drainages.There is no consensus on the best rescue approach in these cases and the choice is often made by the endoscopist relying upon the clinical scenario,anatomical characteristics,and local expertise.In this review,we investigated the misdeployment of LAMS for each of the on-label indications focusing on the rescue therapies used,with the aim of providing useful data for endoscopists and to improve patient outcomes. 展开更多
关键词 Lams misdeployment Endoscopic ultrasound-guided drainage Lams maldeployment Biliary drainage Gallbladder drainage Pancreatic fluid collections Lumen-apposing metal stents
下载PDF
Comprehensive review on endoscopic ultrasound-guided tissue acquisition techniques for solid pancreatic tumor
13
作者 Sakue Masuda Kazuya Koizumi +11 位作者 Kento Shionoya Ryuhei Jinushi Makomo Makazu Takashi Nishino Karen Kimura Chihiro Sumida Jun Kubota Chikamasa Ichita Akiko Sasaki Masahiro Kobayashi Makoto Kako Uojima Haruki 《World Journal of Gastroenterology》 SCIE CAS 2023年第12期1863-1874,共12页
Pancreatic ductal adenocarcinoma is speculated to become the second leading cause of cancer-related mortality by 2030,a high mortality rate considering the number of cases.Surgery and chemotherapy are the main treatme... Pancreatic ductal adenocarcinoma is speculated to become the second leading cause of cancer-related mortality by 2030,a high mortality rate considering the number of cases.Surgery and chemotherapy are the main treatment options,but they are burdensome for patients.A clear histological diagnosis is needed to determine a treatment plan,and endoscopic ultrasound(EUS)-guided tissue acquisition(TA)is a suitable technique that does not worsen the cancer-specific prognosis even for lesions at risk of needle tract seeding.With the development of personalized medicine and precision treatment,there has been an increasing demand to increase cell counts and collect specimens while preserving tissue structure,leading to the development of the fine-needle biopsy(FNB)needle.EUS-FNB is rapidly replacing EUS-guided fine-needle aspiration(FNA)as the procedure of choice for EUS-TA of pancreatic cancer.However,EUS-FNA is sometimes necessary where the FNB needle cannot penetrate small hard lesions,so it is important clinicians are familiar with both.Given these recent developments,we present an up-to-date review of the role of EUS-TA in pancreatic cancer.Particularly,technical aspects,such as needle caliber,negative pressure,and puncture methods,for obtaining an adequate specimen in EUS-TA are discussed. 展开更多
关键词 Endoscopic ultrasound-guided fine needle biopsy Endoscopic ultrasoundguided tissue acquisition Personalized medicine Genomic profiling test Pancreatic cancer Puncture procedure
下载PDF
Effect of ultrasound-guided lumbar square muscle block on stress response in patients undergoing radical gastric cancer surgery
14
作者 Xin-Ran Wang Dan-Dan Xu +3 位作者 Meng-Jiao Guo Yi-Xin Wang Meng Zhang Dong-Xiao Zhu 《World Journal of Gastrointestinal Oncology》 SCIE 2023年第12期2093-2100,共8页
BACKGROUND Radical surgery is a common treatment for patients with gastric cancer;however,it can lead to postoperative complications and intestinal barrier dysfunction.Ultrasound-guided quadratus lumborum block is oft... BACKGROUND Radical surgery is a common treatment for patients with gastric cancer;however,it can lead to postoperative complications and intestinal barrier dysfunction.Ultrasound-guided quadratus lumborum block is often used for postoperative analgesia,but its effects on stress response and intestinal barrier function are not well understood.AIM To investigate the effects of an ultrasound-guided quadratus lumborum block on stress response and intestinal barrier function in patients undergoing radical surgery for gastric cancer.METHODS A total of 100 patients undergoing radical surgery for gastric cancer were randomly categorized into observation and control groups.Plasma adrenaline and cortisol levels,intestinal mucosal barrier indexes,and complication rates were compared between the two groups before,during,and 1 day after surgery.RESULTS The observation group had significantly lower plasma adrenaline and cortisol levels during surgery and at 1 day postoperatively than that of the control group(P<0.05).Additionally,intestinal barrier indexes(endotoxin and D-dimer)at 1 day postoperatively were significantly lower in the observation group than in the control group(P<0.05).CONCLUSION Ultrasound-guided quadratus lumborum block could reduce stress response,protect intestinal barrier function,and decrease the incidence of complications in patients undergoing radical surgery for gastric cancer.This technique has the potential for clinical applications. 展开更多
关键词 ultrasound-guided quadratus lumborum block Radical gastric cancer surgery Stress response Intestinal barrier function Postoperative analgesia REHABILITATION
下载PDF
Bedside ultrasound-guided water injection assists endoscopically treatment in esophageal perforation caused by foreign bodies: A case report
15
作者 Hua-Xing Wei Song-Yong Lv +2 位作者 Bin Xia Kai Zhang Chen-Ke Pan 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第6期1240-1246,共7页
BACKGROUND Fishbone migration from the esophagus to the neck is relatively uncommon in clinical practice.Several complications secondary to esophageal perforation after ingestion of a fishbone have been described in t... BACKGROUND Fishbone migration from the esophagus to the neck is relatively uncommon in clinical practice.Several complications secondary to esophageal perforation after ingestion of a fishbone have been described in the literature.Typically,a fishbone is detected and diagnosed by imaging examination and is usually removed by a neck incision.CASE SUMMARY Herein,we report a case of a 76-year-old patient with a fishbone in the neck that had migrated from the esophagus and that was in close proximity to the common carotid artery,and the patient experienced dysphagia.An endoscopically-guided neck incision was made over the insertion point in the esophagus,but the surgery failed due to having a blurred image at the insertion site during the operation.After injection of normal saline laterally to the fishbone in the neck under ultrasound guidance,the purulent fluid outflowed to the piriform recess along the sinus tract.With endoscopic guidance,the position of the fish bone was precisely located along the direction of liquid outflow,the sinus tract was separated,and the fish bone was removed.To the best of our knowledge,this is the first case report describing bedside ultrasound-guided water injection positioning combined with endoscopy in the treatment of a cervical esophageal perforation with an abscess.CONCLUSION In conclusion,the fishbone could be located by the water injection method under the guidance of ultrasound and could be accurately located along the outflow direction of the purulent fluid of the sinus by the endoscope and was removed by incising the sinus.This method can be a nonoperative treatment option for foreign body-induced esophageal perforation. 展开更多
关键词 Esophageal perforation Foreign body removal FISHBONE Beside ultrasound-guided ENDOSCOPY Case report
下载PDF
Treatment of posterior interosseous nerve entrapment syndrome with ultrasound-guided hydrodissection:A case report
16
作者 Lan-Hui Qin Wan Cao +2 位作者 Fei-Tong Chen Qi-Bo Chen Xi-Xia Liu 《World Journal of Clinical Cases》 SCIE 2023年第27期6624-6630,共7页
BACKGROUND Posterior interosseous nerve(PIN)entrapment syndrome is one of the causes of weakness and pain of the arm muscles,which is prone to missed diagnosis and misdiagnosis in clinic practice.This paper reports a ... BACKGROUND Posterior interosseous nerve(PIN)entrapment syndrome is one of the causes of weakness and pain of the arm muscles,which is prone to missed diagnosis and misdiagnosis in clinic practice.This paper reports a case of PIN entrapment syndrome,with PIN injury indicated by electrophysiology.Musculoskeletal ultrasound was applied to identify that the entrapment point was located at the inlet of the Frohse arch and the outlet of the supinator muscle.Treatment with ultrasound-guided nerve hydrodissection was performed on the entrapment point,which significantly improved the symptoms.Ultrasound-guided nerve hydrodissection is an effective therapeutic method for PIN entrapment syndrome.CASE SUMMARY A male patient,35 years old,worked as an automobile mechanic.He felt slightly weak extension activity of his right fingers 2 years ago but sought no treatment.Later,the symptoms gradually became aggravated and led to finger drop,particularly severe in the right middle finger,accompanied by supination weakness of the right forearm.Neural electrophysiological examination showed that the patient had partial PIN injury of the right radius.Musculoskeletal ultrasound examination indicated PIN entrapment at the inlet of the Frohse arch and the outlet of the supinator muscle.Therefore,PIN entrapment syndrome was diagnosed.After treatment with ultrasound-guided nerve hydrodissection around the entrapment point,the dorsiflexion weakness of the right hand was significantly improved compared with before treatment.CONCLUSION Ultrasound-guided hydrodissection is efficacious for PIN entrapment syndrome,with high clinical value and great application prospects. 展开更多
关键词 ultrasound-guided injection Nerve hydrodissection Posterior interosseous nerve entrapment syndrome Radial nerve Case report
下载PDF
Analgesic effect of ultrasound-guided bilateral transversus abdominis plane block in laparoscopic gastric cancer
17
作者 Ya-Ya Wang Hua-Jun Fu 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第10期2171-2178,共8页
BACKGROUND Postoperative complications are important factors affecting the survival time and quality of life of patients undergoing radical gastrectomy.AIM To investigate and compare the anesthetic effects of intraven... BACKGROUND Postoperative complications are important factors affecting the survival time and quality of life of patients undergoing radical gastrectomy.AIM To investigate and compare the anesthetic effects of intravenous general anesthesia combined with epidural anesthesia or ultrasound-guided bilateral transversus abdominal plane block(TAPB)in gastric cancer patients undergoing laparoscopic radical gastrectomy.METHODS The clinical data of 85 patients who underwent laparoscopic radical gastrectomy in our hospital from December 2020 to January 2023 were retrospectively collected and divided into a TAPB group(n=45)and epidural anesthesia group(n=40)according to the different anesthesia and analgesia programs used.The TAPB group received general anesthesia combined with TAPB,and the epidural anesthesia group received general anesthesia combined with epidural anesthesia.The pain status,cognitive status,intestinal barrier indicators,recovery quality,and incidence of complications were compared between the two groups.RESULTS Compared with the epidural anesthesia group,the TAPB group’s visual analog scale scores were significantly lower 6 h,12 h,24 h and 48 h after surgery(P<0.05).The incidence of postoperative cognitive dysfunction(POCD)in the TAPB group was significantly lower than that in the epidural anesthesia group,and the Mini-mental State Examination score 24 h after surgery was significantly higher in the TAPB group than the epidural anesthesia group(P<0.05).The levels of diamine oxidase and plasma D-lactate were significantly lower in the TAPB group than the epidural anesthesia group 24 h after surgery(P<0.05).The agitation score and the incidence of agitation during recovery were significantly lower in the TAPB group than epidural anesthesia group(P<0.05).The total incidence of postoperative complications in the TAPB group was 4.44%,significantly lower than the 20.00%in the epidural anesthesia group(P<0.05).CONCLUSION Compared with epidural anesthesia combined with general anesthesia,TAPB combined with general anesthesia had a good analgesic effect in laparoscopic radical gastrectomy and can further reduce the incidence of POCD and postoperative complications,improve the levels of intestinal barrier indicators,and improve postoperative recovery quality. 展开更多
关键词 Laparoscopic radical gastrectomy ultrasound-guided bilateral transversus abdominal plane block Cognitive impairment Intestinal barrier function
下载PDF
Effect of Ultrasound-Guided Transversus Abdominis Plane Block Combined with Lornoxicam on Pain and Recovery Quality After Abdominal Surgery in Patients with Drug Addiction
18
作者 Ling Luo Zhouxu Yang Hongtao Yang 《Journal of Clinical and Nursing Research》 2023年第5期89-96,共8页
Objective:This paper aims to analyze the analgesic effect of ultrasound-guided transversus abdominis plane block(TAPB)combined with non-steroidal anti-inflammatory analgesic drug lornoxicam on abdominal surgery in pat... Objective:This paper aims to analyze the analgesic effect of ultrasound-guided transversus abdominis plane block(TAPB)combined with non-steroidal anti-inflammatory analgesic drug lornoxicam on abdominal surgery in patients with a history of drug addiction.Methods:32 patients aged 18-60 who underwent lower abdominal surgery in the First People's Hospital of Liangshan Yi Autonomous Prefecture and Butuo County People's Hospital of Liangshan Yi Autonomous Prefecture from January 2022 to March 2023 were selected,the patients must have drug abuse history for more than 1 year,with a history of drug withdrawal and relapse.The patients were divided into observation group and control group by the envelope method,with 16 cases in the observation group and 16 cases in the control group.Two groups of patients underwent ultrasound-guided bilateral transversus abdominis plane block after the operation.The observation group was treated with dexmedetomidine hydrochloride 1μg/kg+0.25%ropivacaine hydrochloride 40ml,and the control group was treated with 40ml 0.9%sodium chloride injection,the two groups of patients returned to the ward after operation and given intravenous infusion of lornoxicam for relieving the pain.The visual analogue scale(VAS)score of postoperative pain,the times of rescue analgesia,the time of postoperative anal exhaust,the time of ambulation,nausea and vomiting,withdrawal symptoms,related adverse reactions,and hospitalization days were compared between the two groups.Results:The VAS score of postoperative pain in the observation group was significantly lower than that in the control group,P<0.05.Patients in the observation group used less postoperative rescue analgesics than those in the control group,P<0.05.For postoperative anal exhaust time,the difference between the two groups of patients was relatively small,and the time in the observation group was shorter,P>0.05.The time to get out of bed and the length of hospital stay were not significantly different between the control group and the observation group,P>0.05.The withdrawal symptoms of the patients in the observation group were better,P<0.05,nausea and vomiting,and other adverse reactions were lower in the control group,P<0.05.Conclusion:Ultrasound-guided transversus abdominis plane block combined with lornoxicam can be used to relieve pain in abdominal surgery for patients with drug addiction,which can effectively improve the therapeutic effect of patients and reduce the number of postoperative rescue analgesia.Thus,it has high clinical application value. 展开更多
关键词 ultrasound-guided transversus abdominis plane block LORNOXICAM Patients with drug addiction Nursing effect
下载PDF
Urgent endoscopic ultrasound-guided choledochoduodenostomy for acute obstructive suppurative cholangitis-induced sepsis 被引量:18
19
作者 Kosuke Minaga Masayuki Kitano +7 位作者 Hajime Imai Kentaro Yamao Ken Kamata Takeshi Miyata Shunsuke Omoto Kumpei Kadosaka Tomoe Yoshikawa Masatoshi Kudo 《World Journal of Gastroenterology》 SCIE CAS 2016年第16期4264-4269,共6页
Acute obstructive suppurative cholangitis(AOSC) due to biliary lithiasis is a life-threatening condition that requires urgent biliary decompression. Although endoscopic retrograde cholangiopancreatography(ERCP) with s... Acute obstructive suppurative cholangitis(AOSC) due to biliary lithiasis is a life-threatening condition that requires urgent biliary decompression. Although endoscopic retrograde cholangiopancreatography(ERCP) with stent placement is the current gold standard for biliary decompression, it can sometimes be difficult because of failed biliary cannulation. In this retrospective case series, we describe three cases of successful biliary drainage with recovery from septic shock after urgent endoscopic ultrasound-guided choledochoduodenostomy(EUS-CDS) was performed for AOSC due to biliary lithiasis. In all three cases, technical success in inserting the stents was achieved and the patients completely recovered from AOSC with sepsis in a few days after EUS-CDS. There were no procedure-related complications. When initial ERCP fails, EUS-CDS can be an effective life-saving endoscopic biliary decompression procedure that shortens the procedure time and prevents post-ERCP pancreatitis, particularly in patients with AOSC-induced sepsis. 展开更多
关键词 ENDOSCOPIC ultrasound-guideD biliary drainage CHOLEDOCHODUODENOSTOMY Acute OBSTRUCTIVE SUPPURATIVE c
下载PDF
Endoscopic ultrasound-guided biliary intervention in patients with surgically altered anatomy 被引量:8
20
作者 Aroon Siripun Pimsiri Sripongpun Bancha Ovartlarnporn 《World Journal of Gastrointestinal Endoscopy》 CAS 2015年第3期283-289,共7页
AIM: To evaluate the efficacy of endoscopic ultrasound guided biliary drainage(EUS-BD) in patients with surgically altered anatomies.METHODS: We performed a search of the MEDLINE database for studies published between... AIM: To evaluate the efficacy of endoscopic ultrasound guided biliary drainage(EUS-BD) in patients with surgically altered anatomies.METHODS: We performed a search of the MEDLINE database for studies published between 2001 to July2014 reporting on EUS-BD in patients with surgically altered anatomy using the terms "EUS drainage" and "altered anatomy". All relevant articles were accessed in full text. A manual search of the reference lists of relevant retrieved articles was also performed. Only fulltext English papers were included. Data regarding age, gender, diagnosis, method of EUS-BD and intervention, type of altered anatomy, technical success, clinical success, and complications were extracted and collected. Anatomic alterations were categorized as: group 1, Billroth Ⅰ; group 2, Billroth Ⅱ; group 4, Rouxen-Y with gastric bypass; and group 3, all other types. RESULTS: Twenty three articles identified in the literature search, three reports were from the same group with different numbers of cases. In total, 101 cases of EUS-BD in patients with altered anatomy were identified. Twenty-seven cases had no information and were excluded. Seventy four cases were included for analysis. Data of EUS-BD in patients categorized as group 1, 2 and 4 were limited with 2, 3 and 6 cases with EUS-BD done respectively. Thirty four cases with EUS-BD were reported in group 3. The pooled technical success, clinical success, and complication rates of all reports with available data were 89.18%, 91.07% and 17.5%, respectively. The results are similar to the reported outcomes of EUS-BD in general, however, with limited data of EUS-BD in patients with altered anatomy rendered it difficult to draw a firm conclusion. CONCLUSION: EUS-BD may be an option for patients with altered anatomy after a failed endoscopic-retrogradecholangiography in centers with expertise in EUS-BD procedures in a research setting. 展开更多
关键词 ENDOSCOPIC ultrasound-guideD anterogradeapproach ENDOSCOPIC ultrasound-guideD BILIARY drainage ENDOSCOPIC ultrasound-guideD CHOLEDOCHODUODENOSTOMY ENDOSCOPIC ultrasound-guideD hepaticogastrostomy ENDOSCOPIC ultrasound-rendezvous technique Surgicallyaltered ANATOMY Overtube-assisted enteroscopy-endoscopicretrograde cholangiopancreatography
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部