This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ...This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients.展开更多
Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal...Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands.展开更多
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide...BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.展开更多
BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and...BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage.展开更多
Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions...Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions includes percu-taneous,endoscopic,minimally invasive surgery,or a combined approach.Endoscopic drainage is the drainage of PFCs by creating an artificial communication between the collection and gastrointestinal lumen that is maintained by placing a stent across the fistulous tract.In this editorial,we endeavored to update the current status of endoscopic ultrasound-guided drainage of PFCs.展开更多
BACKGROUND Malignant obstructive jaundice(MOJ)is a condition characterized by varying degrees of bile duct stenosis and obstruction,accompanied by the progressive development of malignant tumors,leading to high morbid...BACKGROUND Malignant obstructive jaundice(MOJ)is a condition characterized by varying degrees of bile duct stenosis and obstruction,accompanied by the progressive development of malignant tumors,leading to high morbidity and mortality rates.Currently,the two most commonly employed methods for its management are percutaneous transhepatic bile duct drainage(PTBD)and endoscopic ultrasound-guided biliary drainage(EUS-BD).While both methods have demonstrated favorable outcomes,additional research needs to be performed to determine their relative efficacy.To compare the therapeutic effectiveness of EUS-BD and PTBD in treating MOJ.METHODS This retrospective analysis,conducted between September 2015 and April 2023 at The Third Affiliated Hospital of Soochow University(The First People’s Hospital of Changzhou),involved 68 patients with MOJ.The patients were divided into two groups on the basis of surgical procedure received:EUS-BD subgroup(n=33)and PTBD subgroup(n=35).Variables such as general data,preoperative and postoperative indices,blood routine,liver function indices,myocardial function indices,operative success rate,clinical effectiveness,and complication rate were analyzed and compared between the subgroups.RESULTS In the EUS-BD subgroup,hospital stay duration,bile drainage volume,effective catheter time,and clinical effect-iveness rate were superior to those in the PTBD subgroup,although the differences were not statistically significant(P>0.05).The puncture time for the EUS-BD subgroup was shorter than that for the PTBD subgroup(P<0.05).Postoperative blood routine,liver function index,and myocardial function index in the EUS-BD subgroup were significantly lower than those in the PTBD subgroup(P<0.05).Additionally,the complication rate in the EUS-BD subgroup was lower than in the PTBD subgroup(P<0.05).CONCLUSION EUS-BD may reduce the number of punctures,improve liver and myocardial functions,alleviate traumatic stress,and decrease complication rates in MOJ treatment.展开更多
In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspirat...In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspiration(FNA)or more newly fine needle biopsy(FNB)is a well-developed technique in order to evaluate and differentiate the liver masses.The goal of the EUS-FNA or EUS-FNB is to provide an accurate sample for a histopathology examination.Therefore,malignant tumors such as hepatocarcinoma,cholangiocarcinoma and liver metastasis or benign tumors such as liver adenoma,focal hyperplastic nodular tumors and cystic lesions can be accurately diagnosed using EUS-guided tissue acquisition.EUS-FNB using 19 or 22 Ga needle provide longer samples and a higher diagnostic accuracy in patients with liver masses when compared with EUS-FNA.Few data are available on the diagnostic accuracy of EUS-FNB when compared with percutaneously,ultrasound,computer tomography or transjugulary-guided liver biopsies.This review will discuss the EUS-guided tissue acquisition options in patients with liver tumors and its efficacy and safety in providing accurate samples.The results of the last studies comparing EUS-guided liver biopsy with other conventional techniques are presented.The EUS-guided tissue acquisition using FNB can be a suitable technique in suspected liver lesions in order to provide an accurate histopathology diagnosis,especially for those who require endoscopy.展开更多
Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (...Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (TRUS-SB) is the primary diagnostic method, prebiopsy multiparametric magnetic resonance imaging (mpMRI) is gaining popularity in identifying suspicious lesions. This study addresses the lack of comprehensive investigations into the efficacy of cognitive registration TRUS targeted biopsy (COG-TB) compared to conventional TRUS-SB, considering the resource limitations of the Malaysian healthcare system. Materials and Methods: A retrospective cohort study was conducted in two Malaysian healthcare facilities. 116 adult patients with a prostate-specific antigen (PSA) level of more than 4 ng/mL who underwent both COG-TB and TRUS-SB between October 2020 and March 2022 were included. Primary outcomes were cancer detection rate and histopathological outcomes, including Gleason score. Results: COG-TB showed a higher overall cancer detection rate (50%) compared to TRUS-SB (44%). Clinically significant cancer detection rates were similar between COG-TB and TRUS-SB (37.1%). Further analysis revealed that both COG-TB and TRUS-SB detected clinically significant cancer in 30.2% of patients, did not detect it in 56.0%, and had conflicting findings in 16 patients (p Conclusion: COG-TB and TRUS-SB have comparable detection rates for clinically significant prostate cancer, with COG-TB showing a higher tendency to detect insignificant prostate cancer. Further studies comparing these methods are warranted.展开更多
BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE ...BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE in patients with GOO.METHODS This study was a retrospective,observational,multicenter study in which the data from 10 patients who underwent EUS-GE due to GOO between September 2021 and May 2023 were collected.We analyzed technical success,clinical success,adverse events,and survival.Technical success was defined as adequate positioning and deployment of the stent.Clinical success was defined as the patient’s ability to tolerate oral intake without vomiting 7 d after the procedure.Postprocedural adverse events were recorded.RESULTS Eleven procedures in 10 patients with GOO were included.The mean age of the patients was 67.5 years(range:56-77 years).Malignant GOO was present in 9 patients.Technical success was achieved in 9/11 procedures(82%).Among them,clinical success was achieved in 9 patients(100%).Adverse events occurred in 1 patient(9%).The median survival was 3 months(n=7;range:1-8 months).CONCLUSION EUS-GE is a feasible therapeutic option in the treatment of GOO.展开更多
Pancreatic ductal adenocarcinoma is speculated to become the second leading cause of cancer-related mortality by 2030,a high mortality rate considering the number of cases.Surgery and chemotherapy are the main treatme...Pancreatic ductal adenocarcinoma is speculated to become the second leading cause of cancer-related mortality by 2030,a high mortality rate considering the number of cases.Surgery and chemotherapy are the main treatment options,but they are burdensome for patients.A clear histological diagnosis is needed to determine a treatment plan,and endoscopic ultrasound(EUS)-guided tissue acquisition(TA)is a suitable technique that does not worsen the cancer-specific prognosis even for lesions at risk of needle tract seeding.With the development of personalized medicine and precision treatment,there has been an increasing demand to increase cell counts and collect specimens while preserving tissue structure,leading to the development of the fine-needle biopsy(FNB)needle.EUS-FNB is rapidly replacing EUS-guided fine-needle aspiration(FNA)as the procedure of choice for EUS-TA of pancreatic cancer.However,EUS-FNA is sometimes necessary where the FNB needle cannot penetrate small hard lesions,so it is important clinicians are familiar with both.Given these recent developments,we present an up-to-date review of the role of EUS-TA in pancreatic cancer.Particularly,technical aspects,such as needle caliber,negative pressure,and puncture methods,for obtaining an adequate specimen in EUS-TA are discussed.展开更多
BACKGROUND Postoperative complications are important factors affecting the survival time and quality of life of patients undergoing radical gastrectomy.AIM To investigate and compare the anesthetic effects of intraven...BACKGROUND Postoperative complications are important factors affecting the survival time and quality of life of patients undergoing radical gastrectomy.AIM To investigate and compare the anesthetic effects of intravenous general anesthesia combined with epidural anesthesia or ultrasound-guided bilateral transversus abdominal plane block(TAPB)in gastric cancer patients undergoing laparoscopic radical gastrectomy.METHODS The clinical data of 85 patients who underwent laparoscopic radical gastrectomy in our hospital from December 2020 to January 2023 were retrospectively collected and divided into a TAPB group(n=45)and epidural anesthesia group(n=40)according to the different anesthesia and analgesia programs used.The TAPB group received general anesthesia combined with TAPB,and the epidural anesthesia group received general anesthesia combined with epidural anesthesia.The pain status,cognitive status,intestinal barrier indicators,recovery quality,and incidence of complications were compared between the two groups.RESULTS Compared with the epidural anesthesia group,the TAPB group’s visual analog scale scores were significantly lower 6 h,12 h,24 h and 48 h after surgery(P<0.05).The incidence of postoperative cognitive dysfunction(POCD)in the TAPB group was significantly lower than that in the epidural anesthesia group,and the Mini-mental State Examination score 24 h after surgery was significantly higher in the TAPB group than the epidural anesthesia group(P<0.05).The levels of diamine oxidase and plasma D-lactate were significantly lower in the TAPB group than the epidural anesthesia group 24 h after surgery(P<0.05).The agitation score and the incidence of agitation during recovery were significantly lower in the TAPB group than epidural anesthesia group(P<0.05).The total incidence of postoperative complications in the TAPB group was 4.44%,significantly lower than the 20.00%in the epidural anesthesia group(P<0.05).CONCLUSION Compared with epidural anesthesia combined with general anesthesia,TAPB combined with general anesthesia had a good analgesic effect in laparoscopic radical gastrectomy and can further reduce the incidence of POCD and postoperative complications,improve the levels of intestinal barrier indicators,and improve postoperative recovery quality.展开更多
BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffus...BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffusion in different clinical settings.Nevertheless,the procedure may conceal unexpected pitfalls.LAMS misdeployment is the most frequent cause of technical failure and it can be considered a procedure-related adverse event when it hampers the conclusion of the planned procedure or results in significant clinical consequences.Stent misdeployment can be managed successfully by endoscopic rescue maneuvers to allow the completion of the procedure.To date,no standardized indication is available to guide an appropriate rescue strategy depending on the type of procedure or of misdeployment.AIM To evaluate the incidence of LAMS misdeployment during EUS-guided choledochoduodenostomy(EUS-CDS),gallbladder drainage(EUS-GBD)and pancreatic fluid collections drainage(EUS-PFC)and to describe the endoscopic rescue strategies adopted under the circumstance.METHODS We conducted a systematic review of the literature on PubMed by searching for studies published up to October 2022.The search was carried out using the exploded medical subject heading terms“lumen apposing metal stent”,“LAMS”,“endoscopic ultrasound”and“choledochoduodenostomy”or“gallbladder”or“pancreatic fluid collections”.We included in the review on-label EUS-guided procedures namely EUS-CDS,EUS-GBD and EUS-PFC.Only those publications reporting EUS-guided LAMS positioning were considered.The studies reporting a technical success rate of 100%and other procedure-related adverse events were considered to calculate the overall rate of LAMS misdeployment,while studies not reporting the causes of technical failure were excluded.Case reports were considered only for the extraction of data regarding the issues of misdeployment and rescue techniques.The following data were collected from each study:Author,year of publication,study design,study population,clinical indication,technical success,reported number of misdeployment,stent type and size,flange misdeployed and type of rescue strategy.RESULTS The overall technical success rate of EUS-CDS,EUS-GBD and EUS-PFC was 93.7%,96.1%,and 98.1%respectively.Significant rates of LAMS misdeployment have been reported for EUS-CDS,EUS-GBD and EUS-PFC drainage,respectively 5.8%,3.4%,and 2.0%.Endoscopic rescue treatment was feasible in 86.8%,80%,and 96.8%of cases.Non endoscopic rescue strategies were required only in 10.3%,16%and 3.2%for EUS-CDS,EUS-GBD,and EUS-PFC.The endoscopic rescue techniques described were over-the-wire deployment of a new stent through the created fistula tract in 44.1%,8%and 64.5%and stent-in-stent in 23.5%,60%,and 12.9%,respectively for EUSCDS,EUS-GBD,and EUS-PFC.Further therapeutic option were endoscopic rendezvous in 11.8%of EUS-CDS and repeated procedure of EUS-guided drainage in 16.1%of EUS-PFC.CONCLUSION LAMS misdeployment is a relatively common adverse event in EUS-guided drainages.There is no consensus on the best rescue approach in these cases and the choice is often made by the endoscopist relying upon the clinical scenario,anatomical characteristics,and local expertise.In this review,we investigated the misdeployment of LAMS for each of the on-label indications focusing on the rescue therapies used,with the aim of providing useful data for endoscopists and to improve patient outcomes.展开更多
BACKGROUND Radical surgery is a common treatment for patients with gastric cancer;however,it can lead to postoperative complications and intestinal barrier dysfunction.Ultrasound-guided quadratus lumborum block is oft...BACKGROUND Radical surgery is a common treatment for patients with gastric cancer;however,it can lead to postoperative complications and intestinal barrier dysfunction.Ultrasound-guided quadratus lumborum block is often used for postoperative analgesia,but its effects on stress response and intestinal barrier function are not well understood.AIM To investigate the effects of an ultrasound-guided quadratus lumborum block on stress response and intestinal barrier function in patients undergoing radical surgery for gastric cancer.METHODS A total of 100 patients undergoing radical surgery for gastric cancer were randomly categorized into observation and control groups.Plasma adrenaline and cortisol levels,intestinal mucosal barrier indexes,and complication rates were compared between the two groups before,during,and 1 day after surgery.RESULTS The observation group had significantly lower plasma adrenaline and cortisol levels during surgery and at 1 day postoperatively than that of the control group(P<0.05).Additionally,intestinal barrier indexes(endotoxin and D-dimer)at 1 day postoperatively were significantly lower in the observation group than in the control group(P<0.05).CONCLUSION Ultrasound-guided quadratus lumborum block could reduce stress response,protect intestinal barrier function,and decrease the incidence of complications in patients undergoing radical surgery for gastric cancer.This technique has the potential for clinical applications.展开更多
BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treati...BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treating carotid artery stenosis are drug treatment,carotid endarterectomy(CEA),carotid angioplasty and stenting(CAS).The approach is chosen based on the degree of stenosis.CEA or CAS could have been chosen for the current patient,who had severe carotid stenosis and an iodinated contrast allergy.After thoroughly communicating with the patient,the patient chose CAS for treatment.Therefore,we performed ultrasound-guided CAS to avoid the use of iodinated contrast.CASE SUMMARY The main symptoms of the patient were numbness and weakness of the left limb.Computed tomography angiography of the head and neck at another hospital indicated multiple sites of stenosis in the arteries of the head and neck.The patient requested CAS for treatment but was allergic to iodinated contrast media.Thus,routine digital subtraction angiography(DSA)with iodinated contrast could not be used for the procedure.The diagnosis of this patient was as follows:(1)Right parietal lobe cerebral infarction;(2)multiple sites of stenosis in the arteries of the head and neck(severe stenosis of the right internal carotid artery,severe stenosis of the right subclavian artery);(3)right subclavian steal syndrome;and(4)hypertension(stage 3,high risk).The interventions included routine treatment for cerebral infarction,oral administration of clopidogrel(75 mg qd)and aspirin(100 mg qd),ultrasound-guided CAS,and postoperative follow-up.Postoperative color Doppler ultrasound and cerebrovascular magnetic resonance angiography of the carotid artery showed good vascular recovery,and the postoperative follow-up indicated a good prognosis.CONCLUSION This case study suggests that ultrasound-guided endovascular treatment is a potential option for patients with contraindications to the iodinated contrast agents used in DSA-guided surgery,although excellent surgical operating skills are needed.展开更多
Ptychographic extreme ultraviolet(EUV)diffractive imaging has emerged as a promising candidate for the next generationmetrology solutions in the semiconductor industry,as it can image wafer samples in reflection geome...Ptychographic extreme ultraviolet(EUV)diffractive imaging has emerged as a promising candidate for the next generationmetrology solutions in the semiconductor industry,as it can image wafer samples in reflection geometry at the nanoscale.This technique has surged attention recently,owing to the significant progress in high-harmonic generation(HHG)EUV sources and advancements in both hardware and software for computation.In this study,a novel algorithm is introduced and tested,which enables wavelength-multiplexed reconstruction that enhances the measurement throughput and introduces data diversity,allowing the accurate characterisation of sample structures.To tackle the inherent instabilities of the HHG source,a modal approach was adopted,which represents the crossdensity function of the illumination by a series of mutually incoherent and independent spatial modes.The proposed algorithm was implemented on a mainstream machine learning platform,which leverages automatic differentiation to manage the drastic growth in model complexity and expedites the computation using GPU acceleration.By optimising over 2oo million parameters,we demonstrate the algorithm's capacity to accommodate experimental uncertainties and achieve a resolution approaching the diffraction limit in reflection geometry.The reconstruction of wafer samples with 20-nm high patterned gold structures on a silicon substrate highlights our ability to handle complex physical interrelations involving a multitude of parameters.These results establish ptychography as an efficient and accurate metrology tool.展开更多
Background: Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB) is a widely used modality for acquiring various target samples, but its efficacy in gallbladder masses is unknown. The aim of this retrospective stu...Background: Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB) is a widely used modality for acquiring various target samples, but its efficacy in gallbladder masses is unknown. The aim of this retrospective study was to evaluate the efficacy and safety of EUS-FNB in patients with gallbladder masses. Methods: The study samples were composed of patients from March 2015 to July 2019 who needed to identify the nature of gallbladder masses through EUS-FNB. The outcomes of this study were the adequacy of specimens, diagnostic yields, technical feasibility, and adverse events of the EUS-FNB in gallbladder masses. Results: A total of 27 consecutive patients with a median age of 58 years were included in this study. The 22-gauge FNB needle was feasible in all lesions. The median follow-up period of the patients was 294 days. The specimens sufficient for diagnosis account for 89%(24/27) and 93%(25/27) in cytology and histology, respectively. The overall diagnostic yields for malignancy showed the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.45% [95% confidence interval(CI): 75.12%-99.76%], 100%(95% CI: 46.29%-10 0%), 10 0%(95% CI: 80.76%-100%), 83.33%(95% CI: 36.48%-99.12%), and 96.30%(95% CI: 80.20%-99.99%), respectively. The subgroup analysis revealed that FNB could obtain sufficient specimens and high diagnostic yields in both gallbladder mass < 20.5 mm group and ≥20.5 mm group. One patient experienced mild abdominal pain after the procedure and recovered within one day. Conclusions: EUS-FNB is a reasonable diagnostic tool for the pretreatment diagnosis of patients with gallbladder masses, especially for patients who may miss the opportunity of surgery and need sufficient specimens to identify the pathological type so as to determine chemotherapy regimens. Further largescale studies are needed to confirm our conclusion.展开更多
BACKGROUND Fishbone migration from the esophagus to the neck is relatively uncommon in clinical practice.Several complications secondary to esophageal perforation after ingestion of a fishbone have been described in t...BACKGROUND Fishbone migration from the esophagus to the neck is relatively uncommon in clinical practice.Several complications secondary to esophageal perforation after ingestion of a fishbone have been described in the literature.Typically,a fishbone is detected and diagnosed by imaging examination and is usually removed by a neck incision.CASE SUMMARY Herein,we report a case of a 76-year-old patient with a fishbone in the neck that had migrated from the esophagus and that was in close proximity to the common carotid artery,and the patient experienced dysphagia.An endoscopically-guided neck incision was made over the insertion point in the esophagus,but the surgery failed due to having a blurred image at the insertion site during the operation.After injection of normal saline laterally to the fishbone in the neck under ultrasound guidance,the purulent fluid outflowed to the piriform recess along the sinus tract.With endoscopic guidance,the position of the fish bone was precisely located along the direction of liquid outflow,the sinus tract was separated,and the fish bone was removed.To the best of our knowledge,this is the first case report describing bedside ultrasound-guided water injection positioning combined with endoscopy in the treatment of a cervical esophageal perforation with an abscess.CONCLUSION In conclusion,the fishbone could be located by the water injection method under the guidance of ultrasound and could be accurately located along the outflow direction of the purulent fluid of the sinus by the endoscope and was removed by incising the sinus.This method can be a nonoperative treatment option for foreign body-induced esophageal perforation.展开更多
Wireless Sensor Network(WSN)is a cornerstone of Internet of Things(IoT)and has rich application scenarios.In this work,we consider a heterogeneous WSN whose sensor nodes have a diversity in their Residual Energy(RE).I...Wireless Sensor Network(WSN)is a cornerstone of Internet of Things(IoT)and has rich application scenarios.In this work,we consider a heterogeneous WSN whose sensor nodes have a diversity in their Residual Energy(RE).In this work,to protect the sensor nodes with low RE,we investigate dynamic working modes for sensor nodes which are determined by their RE and an introduced energy threshold.Besides,we employ an Unmanned Aerial Vehicle(UAV)to collect the stored data from the heterogeneous WSN.We aim to jointly optimize the cluster head selection,energy threshold and sensor nodes’working mode to minimize the weighted sum of energy con-sumption from the WSN and UAV,subject to the data collection rate constraint.To this end,we propose an efficient search method to search for an optimal energy threshold,and develop a penalty-based successive convex approximation algorithm to select the cluster heads.Then we present a low-complexity iterative approach to solve the joint optimization problem and discuss the implementation procedure.Numerical results justify that our proposed approach is able to reduce the energy consumption of the sensor nodes with low RE significantly and also saves energy for the whole WSN.展开更多
文摘This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients.
文摘Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands.
文摘BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.
文摘BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage.
文摘Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions includes percu-taneous,endoscopic,minimally invasive surgery,or a combined approach.Endoscopic drainage is the drainage of PFCs by creating an artificial communication between the collection and gastrointestinal lumen that is maintained by placing a stent across the fistulous tract.In this editorial,we endeavored to update the current status of endoscopic ultrasound-guided drainage of PFCs.
文摘BACKGROUND Malignant obstructive jaundice(MOJ)is a condition characterized by varying degrees of bile duct stenosis and obstruction,accompanied by the progressive development of malignant tumors,leading to high morbidity and mortality rates.Currently,the two most commonly employed methods for its management are percutaneous transhepatic bile duct drainage(PTBD)and endoscopic ultrasound-guided biliary drainage(EUS-BD).While both methods have demonstrated favorable outcomes,additional research needs to be performed to determine their relative efficacy.To compare the therapeutic effectiveness of EUS-BD and PTBD in treating MOJ.METHODS This retrospective analysis,conducted between September 2015 and April 2023 at The Third Affiliated Hospital of Soochow University(The First People’s Hospital of Changzhou),involved 68 patients with MOJ.The patients were divided into two groups on the basis of surgical procedure received:EUS-BD subgroup(n=33)and PTBD subgroup(n=35).Variables such as general data,preoperative and postoperative indices,blood routine,liver function indices,myocardial function indices,operative success rate,clinical effectiveness,and complication rate were analyzed and compared between the subgroups.RESULTS In the EUS-BD subgroup,hospital stay duration,bile drainage volume,effective catheter time,and clinical effect-iveness rate were superior to those in the PTBD subgroup,although the differences were not statistically significant(P>0.05).The puncture time for the EUS-BD subgroup was shorter than that for the PTBD subgroup(P<0.05).Postoperative blood routine,liver function index,and myocardial function index in the EUS-BD subgroup were significantly lower than those in the PTBD subgroup(P<0.05).Additionally,the complication rate in the EUS-BD subgroup was lower than in the PTBD subgroup(P<0.05).CONCLUSION EUS-BD may reduce the number of punctures,improve liver and myocardial functions,alleviate traumatic stress,and decrease complication rates in MOJ treatment.
文摘In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspiration(FNA)or more newly fine needle biopsy(FNB)is a well-developed technique in order to evaluate and differentiate the liver masses.The goal of the EUS-FNA or EUS-FNB is to provide an accurate sample for a histopathology examination.Therefore,malignant tumors such as hepatocarcinoma,cholangiocarcinoma and liver metastasis or benign tumors such as liver adenoma,focal hyperplastic nodular tumors and cystic lesions can be accurately diagnosed using EUS-guided tissue acquisition.EUS-FNB using 19 or 22 Ga needle provide longer samples and a higher diagnostic accuracy in patients with liver masses when compared with EUS-FNA.Few data are available on the diagnostic accuracy of EUS-FNB when compared with percutaneously,ultrasound,computer tomography or transjugulary-guided liver biopsies.This review will discuss the EUS-guided tissue acquisition options in patients with liver tumors and its efficacy and safety in providing accurate samples.The results of the last studies comparing EUS-guided liver biopsy with other conventional techniques are presented.The EUS-guided tissue acquisition using FNB can be a suitable technique in suspected liver lesions in order to provide an accurate histopathology diagnosis,especially for those who require endoscopy.
文摘Introduction: Prostate cancer (PCa) is the third most prevalent cancer among Malaysian males, often diagnosed at advanced stages, leading to suboptimal outcomes. While transrectal ultrasound-guided systematic biopsy (TRUS-SB) is the primary diagnostic method, prebiopsy multiparametric magnetic resonance imaging (mpMRI) is gaining popularity in identifying suspicious lesions. This study addresses the lack of comprehensive investigations into the efficacy of cognitive registration TRUS targeted biopsy (COG-TB) compared to conventional TRUS-SB, considering the resource limitations of the Malaysian healthcare system. Materials and Methods: A retrospective cohort study was conducted in two Malaysian healthcare facilities. 116 adult patients with a prostate-specific antigen (PSA) level of more than 4 ng/mL who underwent both COG-TB and TRUS-SB between October 2020 and March 2022 were included. Primary outcomes were cancer detection rate and histopathological outcomes, including Gleason score. Results: COG-TB showed a higher overall cancer detection rate (50%) compared to TRUS-SB (44%). Clinically significant cancer detection rates were similar between COG-TB and TRUS-SB (37.1%). Further analysis revealed that both COG-TB and TRUS-SB detected clinically significant cancer in 30.2% of patients, did not detect it in 56.0%, and had conflicting findings in 16 patients (p Conclusion: COG-TB and TRUS-SB have comparable detection rates for clinically significant prostate cancer, with COG-TB showing a higher tendency to detect insignificant prostate cancer. Further studies comparing these methods are warranted.
文摘BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE in patients with GOO.METHODS This study was a retrospective,observational,multicenter study in which the data from 10 patients who underwent EUS-GE due to GOO between September 2021 and May 2023 were collected.We analyzed technical success,clinical success,adverse events,and survival.Technical success was defined as adequate positioning and deployment of the stent.Clinical success was defined as the patient’s ability to tolerate oral intake without vomiting 7 d after the procedure.Postprocedural adverse events were recorded.RESULTS Eleven procedures in 10 patients with GOO were included.The mean age of the patients was 67.5 years(range:56-77 years).Malignant GOO was present in 9 patients.Technical success was achieved in 9/11 procedures(82%).Among them,clinical success was achieved in 9 patients(100%).Adverse events occurred in 1 patient(9%).The median survival was 3 months(n=7;range:1-8 months).CONCLUSION EUS-GE is a feasible therapeutic option in the treatment of GOO.
文摘Pancreatic ductal adenocarcinoma is speculated to become the second leading cause of cancer-related mortality by 2030,a high mortality rate considering the number of cases.Surgery and chemotherapy are the main treatment options,but they are burdensome for patients.A clear histological diagnosis is needed to determine a treatment plan,and endoscopic ultrasound(EUS)-guided tissue acquisition(TA)is a suitable technique that does not worsen the cancer-specific prognosis even for lesions at risk of needle tract seeding.With the development of personalized medicine and precision treatment,there has been an increasing demand to increase cell counts and collect specimens while preserving tissue structure,leading to the development of the fine-needle biopsy(FNB)needle.EUS-FNB is rapidly replacing EUS-guided fine-needle aspiration(FNA)as the procedure of choice for EUS-TA of pancreatic cancer.However,EUS-FNA is sometimes necessary where the FNB needle cannot penetrate small hard lesions,so it is important clinicians are familiar with both.Given these recent developments,we present an up-to-date review of the role of EUS-TA in pancreatic cancer.Particularly,technical aspects,such as needle caliber,negative pressure,and puncture methods,for obtaining an adequate specimen in EUS-TA are discussed.
文摘BACKGROUND Postoperative complications are important factors affecting the survival time and quality of life of patients undergoing radical gastrectomy.AIM To investigate and compare the anesthetic effects of intravenous general anesthesia combined with epidural anesthesia or ultrasound-guided bilateral transversus abdominal plane block(TAPB)in gastric cancer patients undergoing laparoscopic radical gastrectomy.METHODS The clinical data of 85 patients who underwent laparoscopic radical gastrectomy in our hospital from December 2020 to January 2023 were retrospectively collected and divided into a TAPB group(n=45)and epidural anesthesia group(n=40)according to the different anesthesia and analgesia programs used.The TAPB group received general anesthesia combined with TAPB,and the epidural anesthesia group received general anesthesia combined with epidural anesthesia.The pain status,cognitive status,intestinal barrier indicators,recovery quality,and incidence of complications were compared between the two groups.RESULTS Compared with the epidural anesthesia group,the TAPB group’s visual analog scale scores were significantly lower 6 h,12 h,24 h and 48 h after surgery(P<0.05).The incidence of postoperative cognitive dysfunction(POCD)in the TAPB group was significantly lower than that in the epidural anesthesia group,and the Mini-mental State Examination score 24 h after surgery was significantly higher in the TAPB group than the epidural anesthesia group(P<0.05).The levels of diamine oxidase and plasma D-lactate were significantly lower in the TAPB group than the epidural anesthesia group 24 h after surgery(P<0.05).The agitation score and the incidence of agitation during recovery were significantly lower in the TAPB group than epidural anesthesia group(P<0.05).The total incidence of postoperative complications in the TAPB group was 4.44%,significantly lower than the 20.00%in the epidural anesthesia group(P<0.05).CONCLUSION Compared with epidural anesthesia combined with general anesthesia,TAPB combined with general anesthesia had a good analgesic effect in laparoscopic radical gastrectomy and can further reduce the incidence of POCD and postoperative complications,improve the levels of intestinal barrier indicators,and improve postoperative recovery quality.
文摘BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffusion in different clinical settings.Nevertheless,the procedure may conceal unexpected pitfalls.LAMS misdeployment is the most frequent cause of technical failure and it can be considered a procedure-related adverse event when it hampers the conclusion of the planned procedure or results in significant clinical consequences.Stent misdeployment can be managed successfully by endoscopic rescue maneuvers to allow the completion of the procedure.To date,no standardized indication is available to guide an appropriate rescue strategy depending on the type of procedure or of misdeployment.AIM To evaluate the incidence of LAMS misdeployment during EUS-guided choledochoduodenostomy(EUS-CDS),gallbladder drainage(EUS-GBD)and pancreatic fluid collections drainage(EUS-PFC)and to describe the endoscopic rescue strategies adopted under the circumstance.METHODS We conducted a systematic review of the literature on PubMed by searching for studies published up to October 2022.The search was carried out using the exploded medical subject heading terms“lumen apposing metal stent”,“LAMS”,“endoscopic ultrasound”and“choledochoduodenostomy”or“gallbladder”or“pancreatic fluid collections”.We included in the review on-label EUS-guided procedures namely EUS-CDS,EUS-GBD and EUS-PFC.Only those publications reporting EUS-guided LAMS positioning were considered.The studies reporting a technical success rate of 100%and other procedure-related adverse events were considered to calculate the overall rate of LAMS misdeployment,while studies not reporting the causes of technical failure were excluded.Case reports were considered only for the extraction of data regarding the issues of misdeployment and rescue techniques.The following data were collected from each study:Author,year of publication,study design,study population,clinical indication,technical success,reported number of misdeployment,stent type and size,flange misdeployed and type of rescue strategy.RESULTS The overall technical success rate of EUS-CDS,EUS-GBD and EUS-PFC was 93.7%,96.1%,and 98.1%respectively.Significant rates of LAMS misdeployment have been reported for EUS-CDS,EUS-GBD and EUS-PFC drainage,respectively 5.8%,3.4%,and 2.0%.Endoscopic rescue treatment was feasible in 86.8%,80%,and 96.8%of cases.Non endoscopic rescue strategies were required only in 10.3%,16%and 3.2%for EUS-CDS,EUS-GBD,and EUS-PFC.The endoscopic rescue techniques described were over-the-wire deployment of a new stent through the created fistula tract in 44.1%,8%and 64.5%and stent-in-stent in 23.5%,60%,and 12.9%,respectively for EUSCDS,EUS-GBD,and EUS-PFC.Further therapeutic option were endoscopic rendezvous in 11.8%of EUS-CDS and repeated procedure of EUS-guided drainage in 16.1%of EUS-PFC.CONCLUSION LAMS misdeployment is a relatively common adverse event in EUS-guided drainages.There is no consensus on the best rescue approach in these cases and the choice is often made by the endoscopist relying upon the clinical scenario,anatomical characteristics,and local expertise.In this review,we investigated the misdeployment of LAMS for each of the on-label indications focusing on the rescue therapies used,with the aim of providing useful data for endoscopists and to improve patient outcomes.
文摘BACKGROUND Radical surgery is a common treatment for patients with gastric cancer;however,it can lead to postoperative complications and intestinal barrier dysfunction.Ultrasound-guided quadratus lumborum block is often used for postoperative analgesia,but its effects on stress response and intestinal barrier function are not well understood.AIM To investigate the effects of an ultrasound-guided quadratus lumborum block on stress response and intestinal barrier function in patients undergoing radical surgery for gastric cancer.METHODS A total of 100 patients undergoing radical surgery for gastric cancer were randomly categorized into observation and control groups.Plasma adrenaline and cortisol levels,intestinal mucosal barrier indexes,and complication rates were compared between the two groups before,during,and 1 day after surgery.RESULTS The observation group had significantly lower plasma adrenaline and cortisol levels during surgery and at 1 day postoperatively than that of the control group(P<0.05).Additionally,intestinal barrier indexes(endotoxin and D-dimer)at 1 day postoperatively were significantly lower in the observation group than in the control group(P<0.05).CONCLUSION Ultrasound-guided quadratus lumborum block could reduce stress response,protect intestinal barrier function,and decrease the incidence of complications in patients undergoing radical surgery for gastric cancer.This technique has the potential for clinical applications.
基金Supported by the Foundation of the Longhua District Health System Project Cooperation 2022(basic and clinical research in ischemic stroke).
文摘BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treating carotid artery stenosis are drug treatment,carotid endarterectomy(CEA),carotid angioplasty and stenting(CAS).The approach is chosen based on the degree of stenosis.CEA or CAS could have been chosen for the current patient,who had severe carotid stenosis and an iodinated contrast allergy.After thoroughly communicating with the patient,the patient chose CAS for treatment.Therefore,we performed ultrasound-guided CAS to avoid the use of iodinated contrast.CASE SUMMARY The main symptoms of the patient were numbness and weakness of the left limb.Computed tomography angiography of the head and neck at another hospital indicated multiple sites of stenosis in the arteries of the head and neck.The patient requested CAS for treatment but was allergic to iodinated contrast media.Thus,routine digital subtraction angiography(DSA)with iodinated contrast could not be used for the procedure.The diagnosis of this patient was as follows:(1)Right parietal lobe cerebral infarction;(2)multiple sites of stenosis in the arteries of the head and neck(severe stenosis of the right internal carotid artery,severe stenosis of the right subclavian artery);(3)right subclavian steal syndrome;and(4)hypertension(stage 3,high risk).The interventions included routine treatment for cerebral infarction,oral administration of clopidogrel(75 mg qd)and aspirin(100 mg qd),ultrasound-guided CAS,and postoperative follow-up.Postoperative color Doppler ultrasound and cerebrovascular magnetic resonance angiography of the carotid artery showed good vascular recovery,and the postoperative follow-up indicated a good prognosis.CONCLUSION This case study suggests that ultrasound-guided endovascular treatment is a potential option for patients with contraindications to the iodinated contrast agents used in DSA-guided surgery,although excellent surgical operating skills are needed.
基金the project Lensless Imaging of 3D Nanostructures with Soft X-Rays(LINX)with project number P16-08 of the Perspectief research programme financed by the Dutch Research Council(NWO).
文摘Ptychographic extreme ultraviolet(EUV)diffractive imaging has emerged as a promising candidate for the next generationmetrology solutions in the semiconductor industry,as it can image wafer samples in reflection geometry at the nanoscale.This technique has surged attention recently,owing to the significant progress in high-harmonic generation(HHG)EUV sources and advancements in both hardware and software for computation.In this study,a novel algorithm is introduced and tested,which enables wavelength-multiplexed reconstruction that enhances the measurement throughput and introduces data diversity,allowing the accurate characterisation of sample structures.To tackle the inherent instabilities of the HHG source,a modal approach was adopted,which represents the crossdensity function of the illumination by a series of mutually incoherent and independent spatial modes.The proposed algorithm was implemented on a mainstream machine learning platform,which leverages automatic differentiation to manage the drastic growth in model complexity and expedites the computation using GPU acceleration.By optimising over 2oo million parameters,we demonstrate the algorithm's capacity to accommodate experimental uncertainties and achieve a resolution approaching the diffraction limit in reflection geometry.The reconstruction of wafer samples with 20-nm high patterned gold structures on a silicon substrate highlights our ability to handle complex physical interrelations involving a multitude of parameters.These results establish ptychography as an efficient and accurate metrology tool.
基金supported by a grant from the National Ma-jor Diseases Multidisciplinary Cooperative Diagnosis and Treat-ment Project-Gastrointestinal Cancer MDT Diagnosis and Treat-ment Project
文摘Background: Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB) is a widely used modality for acquiring various target samples, but its efficacy in gallbladder masses is unknown. The aim of this retrospective study was to evaluate the efficacy and safety of EUS-FNB in patients with gallbladder masses. Methods: The study samples were composed of patients from March 2015 to July 2019 who needed to identify the nature of gallbladder masses through EUS-FNB. The outcomes of this study were the adequacy of specimens, diagnostic yields, technical feasibility, and adverse events of the EUS-FNB in gallbladder masses. Results: A total of 27 consecutive patients with a median age of 58 years were included in this study. The 22-gauge FNB needle was feasible in all lesions. The median follow-up period of the patients was 294 days. The specimens sufficient for diagnosis account for 89%(24/27) and 93%(25/27) in cytology and histology, respectively. The overall diagnostic yields for malignancy showed the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.45% [95% confidence interval(CI): 75.12%-99.76%], 100%(95% CI: 46.29%-10 0%), 10 0%(95% CI: 80.76%-100%), 83.33%(95% CI: 36.48%-99.12%), and 96.30%(95% CI: 80.20%-99.99%), respectively. The subgroup analysis revealed that FNB could obtain sufficient specimens and high diagnostic yields in both gallbladder mass < 20.5 mm group and ≥20.5 mm group. One patient experienced mild abdominal pain after the procedure and recovered within one day. Conclusions: EUS-FNB is a reasonable diagnostic tool for the pretreatment diagnosis of patients with gallbladder masses, especially for patients who may miss the opportunity of surgery and need sufficient specimens to identify the pathological type so as to determine chemotherapy regimens. Further largescale studies are needed to confirm our conclusion.
文摘BACKGROUND Fishbone migration from the esophagus to the neck is relatively uncommon in clinical practice.Several complications secondary to esophageal perforation after ingestion of a fishbone have been described in the literature.Typically,a fishbone is detected and diagnosed by imaging examination and is usually removed by a neck incision.CASE SUMMARY Herein,we report a case of a 76-year-old patient with a fishbone in the neck that had migrated from the esophagus and that was in close proximity to the common carotid artery,and the patient experienced dysphagia.An endoscopically-guided neck incision was made over the insertion point in the esophagus,but the surgery failed due to having a blurred image at the insertion site during the operation.After injection of normal saline laterally to the fishbone in the neck under ultrasound guidance,the purulent fluid outflowed to the piriform recess along the sinus tract.With endoscopic guidance,the position of the fish bone was precisely located along the direction of liquid outflow,the sinus tract was separated,and the fish bone was removed.To the best of our knowledge,this is the first case report describing bedside ultrasound-guided water injection positioning combined with endoscopy in the treatment of a cervical esophageal perforation with an abscess.CONCLUSION In conclusion,the fishbone could be located by the water injection method under the guidance of ultrasound and could be accurately located along the outflow direction of the purulent fluid of the sinus by the endoscope and was removed by incising the sinus.This method can be a nonoperative treatment option for foreign body-induced esophageal perforation.
基金supported in part by the National Nature Science Foundation of China under Grant 62001168in part by the Foundation and Application Research Grant of Guangzhou under Grant 202102020515.
文摘Wireless Sensor Network(WSN)is a cornerstone of Internet of Things(IoT)and has rich application scenarios.In this work,we consider a heterogeneous WSN whose sensor nodes have a diversity in their Residual Energy(RE).In this work,to protect the sensor nodes with low RE,we investigate dynamic working modes for sensor nodes which are determined by their RE and an introduced energy threshold.Besides,we employ an Unmanned Aerial Vehicle(UAV)to collect the stored data from the heterogeneous WSN.We aim to jointly optimize the cluster head selection,energy threshold and sensor nodes’working mode to minimize the weighted sum of energy con-sumption from the WSN and UAV,subject to the data collection rate constraint.To this end,we propose an efficient search method to search for an optimal energy threshold,and develop a penalty-based successive convex approximation algorithm to select the cluster heads.Then we present a low-complexity iterative approach to solve the joint optimization problem and discuss the implementation procedure.Numerical results justify that our proposed approach is able to reduce the energy consumption of the sensor nodes with low RE significantly and also saves energy for the whole WSN.