Objective The growth and repair potential of three typical microorganisms in reclaimed water after UV disinfection was investigated to assess the effects of photo-reactivation and dark repair of microorganisms,and the...Objective The growth and repair potential of three typical microorganisms in reclaimed water after UV disinfection was investigated to assess the effects of photo-reactivation and dark repair of microorganisms,and the microbial safety of reclaimed water following this procedure.Methods The growth and repair potential of Escherichia coli,a fecal coliform strain and Bacillus subtilis in the effluent of a biological wastewater treatment plant disinfected by a low-pressure UV lamp were investigated.Results Any increase in bacterial numbers in the effluent after UV disinfection was due to damage repair.Exposure to photo-reactivating light for 8-10 h after UV irradiation with a dose of 5 mJ/cm 2,the highest percentage of photo-reactivation observed for E.coli and the fecal coliform strain was 29% and 15% respectively.B.subtilis showed little photo-reactivation under these conditions.The percentage of photo-reactivation was related to the UV dose and the photo-reactivating time,and a function was developed to forecast the final concentrations of E.coli and the fecal coliform strain after UV disinfection with possible photo-reactivation.Conclusion Different species of bacteria displayed different responses to UV light and different repair potentials.The repair of indigenous bacteria in wastewater needs to be investigated in future work.展开更多
Two strains H2-410 and H2-419 were obtained from the chemically mutated survivors of wild Haematococcus pluvialis 2 by using ethyl methanesulphonate (EMS). Strains H2-410 and H2-419 showed a fast cell growth with 13% ...Two strains H2-410 and H2-419 were obtained from the chemically mutated survivors of wild Haematococcus pluvialis 2 by using ethyl methanesulphonate (EMS). Strains H2-410 and H2-419 showed a fast cell growth with 13% and 20% increase in biomass compared to wild type, respectively. Then H2-419-4, a fast cell growth and high astaxanthin accumulation strain, was obtained by exposing the strain H2-419 to ultraviolet radiation (UV) further. The total biomass, the astaxanthin content per cell, astaxanthin production of H2-419-4 showed 68%, 28%, and 120% increase compared to wild H. pluvialis 2, respectively. HPLC (High Performance Liquid Chromatography) data showed also an obvious proportional variation of different carotenoid compositions in the extracts of H2-419-4 and the wild type, although no peak of carotenoids appeared or disappeared. Therefore, the main compositions in strain H2-419-4, like its wild one, were free of astaxanthin, monoester, and diester of astaxanthin. The asexual reproduction in survivors after exposed to UV was not synchronous, and different from the normal synchronous asexual reproduction as the mother cells were motile instead of non-motile. Interestingly, some survivors from UV irradiation produced many mini-spores (or gamete?), the spores moved away from the mother cell gradually 4 or 5 days later. This is quite similar to sexual reproduction described by Elliot in 1934. However, whether this was sexual reproduction remains questionable, as no mating process has been observed.展开更多
We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance in...We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.展开更多
The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high ...The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high frequency, and the desired disinfection effect is difficult to be ensured. The particles size and particle-associated fecal coliform (F.C.) contribution, and their influence on UV disinfection were investigated when ClO2 and UV combined disinfection process was used. The results showed that suspended solids content had a major impact on UV disinfection efficiency, especially the large particle size fraction. Particles (D〉10μm) associated F. C. were difficult to be disinfected and were the main part of the railings of F.C. inactivation curve. Pre-ClO2 oxidation could reduce the number of particles in effluent, and make large particles decrease to small ones. Therefore, the influence of particles on UV disinfection could be reduced after pre-ClO2 oxidation, and the resistance ability to particle loadings of combined process was enhanced. Moreover, the combined process has a lot of advantages, such as low toxicity, low operational/maintenance costs; it is also convenient to be established in the existing wastewater plant or the new planned one.展开更多
UV radiation and ozonation were investigated as disinfection alternatives for the wastewater treatment plant. The inactivation of total and fecal coliforms using ozone and ultraviolet radiation as separate treatments ...UV radiation and ozonation were investigated as disinfection alternatives for the wastewater treatment plant. The inactivation of total and fecal coliforms using ozone and ultraviolet radiation as separate treatments was evaluated. Different ozone concentrations (3 to 40 mg O3/L) were applied and UV fluencies ranging from 8.5 to 12 mJ/cm2 at different pH values (from 5 to 9) were tested. Best results were obtained for ozone doses near 20 mg/min with removals of 72% and 78% of fecal and total coliforms, respectively. The ozone also was capable of oxidizing organic matter in the effluent measured as COD (the highest removal obtained was 36% for 20 mg O3/min). Maximum bacterial resistance was observed at pH 7 in both cases. The UV light offered a high bacterial inactivation (over 80%) and the lowest bacterial inactivation was observed at pH 7. Finally, we obtained the electric energy per order (EEO, kWh/m3/order), defined as the electric energy (kW-h) required to degrade a contaminant by one order of magnitude in a unit volume of contaminated water, being noteworthy that EEO values for the UV process resulted were lower than those determined for the process with ozone in all the water flow tested.展开更多
The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is diff...The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is difficult to achieve sometimes. The authors studied the particle size distribution, contribution of particle-associated Fecal Coliform (F.C.), and their influences on UV disinfection. A combined disinfection process (chlorination with a subsequent UV disinfection) was tested to improve the disinfection effect. The results indicated that the content of suspended solids, especially that of large particles, has a strong impact on UV disinfection efficiency; D>10 μm particles associated F.C. are difficult to be disinfected and are the main part of the tailings of F.C. inactivation curves. Pre-chlorination could decrease the number of particles in the secondary effluent and transform the large particles into small ones, reducing the influence of particles on UV disinfection and enhancing the resistance ability of the combined process to particle loading.展开更多
Affected by COVID-19,disinfection and purification in public space,such as ordinary school,had aroused wide public concern.This study presents an improved structure of nowadays medical used UV air purifier and discuss...Affected by COVID-19,disinfection and purification in public space,such as ordinary school,had aroused wide public concern.This study presents an improved structure of nowadays medical used UV air purifier and discusses about its efficiency optimization,by utilizing following processes:Firstly,establishing the inner structure of the machine on computer and setting up the boundary conditions.Secondly,employing CFD(Computational Fluid Dynamics)to proceed the simulation of air swirl and the time used,and analyzing the relationship between different parameters and time.Finally,combining optimized parameters to obtain the best time used.The optimized structure efficaciously reduces the cost of machine,making utilization in the classroom become possible.展开更多
基金supported by the National Science Fund for Distinguished Young Scholars of China
文摘Objective The growth and repair potential of three typical microorganisms in reclaimed water after UV disinfection was investigated to assess the effects of photo-reactivation and dark repair of microorganisms,and the microbial safety of reclaimed water following this procedure.Methods The growth and repair potential of Escherichia coli,a fecal coliform strain and Bacillus subtilis in the effluent of a biological wastewater treatment plant disinfected by a low-pressure UV lamp were investigated.Results Any increase in bacterial numbers in the effluent after UV disinfection was due to damage repair.Exposure to photo-reactivating light for 8-10 h after UV irradiation with a dose of 5 mJ/cm 2,the highest percentage of photo-reactivation observed for E.coli and the fecal coliform strain was 29% and 15% respectively.B.subtilis showed little photo-reactivation under these conditions.The percentage of photo-reactivation was related to the UV dose and the photo-reactivating time,and a function was developed to forecast the final concentrations of E.coli and the fecal coliform strain after UV disinfection with possible photo-reactivation.Conclusion Different species of bacteria displayed different responses to UV light and different repair potentials.The repair of indigenous bacteria in wastewater needs to be investigated in future work.
基金the Innovation Program of the Institute of Oceanology,CAS (No.L86032523)the Project of Ministry of Sciences and Technology of China (No.02EFN216601213)
文摘Two strains H2-410 and H2-419 were obtained from the chemically mutated survivors of wild Haematococcus pluvialis 2 by using ethyl methanesulphonate (EMS). Strains H2-410 and H2-419 showed a fast cell growth with 13% and 20% increase in biomass compared to wild type, respectively. Then H2-419-4, a fast cell growth and high astaxanthin accumulation strain, was obtained by exposing the strain H2-419 to ultraviolet radiation (UV) further. The total biomass, the astaxanthin content per cell, astaxanthin production of H2-419-4 showed 68%, 28%, and 120% increase compared to wild H. pluvialis 2, respectively. HPLC (High Performance Liquid Chromatography) data showed also an obvious proportional variation of different carotenoid compositions in the extracts of H2-419-4 and the wild type, although no peak of carotenoids appeared or disappeared. Therefore, the main compositions in strain H2-419-4, like its wild one, were free of astaxanthin, monoester, and diester of astaxanthin. The asexual reproduction in survivors after exposed to UV was not synchronous, and different from the normal synchronous asexual reproduction as the mother cells were motile instead of non-motile. Interestingly, some survivors from UV irradiation produced many mini-spores (or gamete?), the spores moved away from the mother cell gradually 4 or 5 days later. This is quite similar to sexual reproduction described by Elliot in 1934. However, whether this was sexual reproduction remains questionable, as no mating process has been observed.
基金supported by Hunan Health and Family Planning Commission program[C2017060]
文摘We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.
文摘The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high frequency, and the desired disinfection effect is difficult to be ensured. The particles size and particle-associated fecal coliform (F.C.) contribution, and their influence on UV disinfection were investigated when ClO2 and UV combined disinfection process was used. The results showed that suspended solids content had a major impact on UV disinfection efficiency, especially the large particle size fraction. Particles (D〉10μm) associated F. C. were difficult to be disinfected and were the main part of the railings of F.C. inactivation curve. Pre-ClO2 oxidation could reduce the number of particles in effluent, and make large particles decrease to small ones. Therefore, the influence of particles on UV disinfection could be reduced after pre-ClO2 oxidation, and the resistance ability to particle loadings of combined process was enhanced. Moreover, the combined process has a lot of advantages, such as low toxicity, low operational/maintenance costs; it is also convenient to be established in the existing wastewater plant or the new planned one.
文摘UV radiation and ozonation were investigated as disinfection alternatives for the wastewater treatment plant. The inactivation of total and fecal coliforms using ozone and ultraviolet radiation as separate treatments was evaluated. Different ozone concentrations (3 to 40 mg O3/L) were applied and UV fluencies ranging from 8.5 to 12 mJ/cm2 at different pH values (from 5 to 9) were tested. Best results were obtained for ozone doses near 20 mg/min with removals of 72% and 78% of fecal and total coliforms, respectively. The ozone also was capable of oxidizing organic matter in the effluent measured as COD (the highest removal obtained was 36% for 20 mg O3/min). Maximum bacterial resistance was observed at pH 7 in both cases. The UV light offered a high bacterial inactivation (over 80%) and the lowest bacterial inactivation was observed at pH 7. Finally, we obtained the electric energy per order (EEO, kWh/m3/order), defined as the electric energy (kW-h) required to degrade a contaminant by one order of magnitude in a unit volume of contaminated water, being noteworthy that EEO values for the UV process resulted were lower than those determined for the process with ozone in all the water flow tested.
文摘The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is difficult to achieve sometimes. The authors studied the particle size distribution, contribution of particle-associated Fecal Coliform (F.C.), and their influences on UV disinfection. A combined disinfection process (chlorination with a subsequent UV disinfection) was tested to improve the disinfection effect. The results indicated that the content of suspended solids, especially that of large particles, has a strong impact on UV disinfection efficiency; D>10 μm particles associated F.C. are difficult to be disinfected and are the main part of the tailings of F.C. inactivation curves. Pre-chlorination could decrease the number of particles in the secondary effluent and transform the large particles into small ones, reducing the influence of particles on UV disinfection and enhancing the resistance ability of the combined process to particle loading.
文摘Affected by COVID-19,disinfection and purification in public space,such as ordinary school,had aroused wide public concern.This study presents an improved structure of nowadays medical used UV air purifier and discusses about its efficiency optimization,by utilizing following processes:Firstly,establishing the inner structure of the machine on computer and setting up the boundary conditions.Secondly,employing CFD(Computational Fluid Dynamics)to proceed the simulation of air swirl and the time used,and analyzing the relationship between different parameters and time.Finally,combining optimized parameters to obtain the best time used.The optimized structure efficaciously reduces the cost of machine,making utilization in the classroom become possible.