This paper presents a comparative investigation into unbalanced magnetic force(UMF)of asymmetric permanent magnet machines without rotor eccentricities,particularly focusing on the difference between internal-and exte...This paper presents a comparative investigation into unbalanced magnetic force(UMF)of asymmetric permanent magnet machines without rotor eccentricities,particularly focusing on the difference between internal-and external-rotor topologies.The asymmetric field distribution results in radial and tangential asymmetric force waves.Although the radial and tangential stresses are in different direction,the UMF components they produce are nearly aligned.The UMF from asymmetric radial force wave can be additive or subtractive to that from asymmetric tangential force wave.Investigation shows that for the same pole slot number combination,if the UMFs due to radial and tangential force waves are additive in internal rotor machine,they are subtractive in the external rotor counterpart,and vice versa.Investigation reveals a general rule determining whether additive or cancelling:for a UMF produced by any two field harmonics,they are additive if the higher order is produced by the outer part outside the airgap,but cancelling if the higher order is produced by the inner part.Therefore,for a machine with pole number 2p=3k+1,they are additive if it is an external-rotor machine,but otherwise subtractive.On the other hand,for a machine with pole number 2p=3k-1,they are subtractive if it is an external-rotor machine,but otherwise additive.For the UMF due to armature reaction only,they are subtractive for external-rotor machines,but otherwise additive.The investigation is carried out by an analytical model and validated by finite element analysis.展开更多
The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase f...The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase faulty conditions.The model derivations are extended from previous accurate subdomain models accounting for slotting effects.Compared with most conventional subdomain models for traditional three-phase machines with nonoverlapping winding arrangement,the subdomain model proposed in this paper applied for the 24-slot/4-pole dual three-phase machine with symmetrical overlapping winding arrangement.In order to investigate the postfault electromagnetic performance,the reconfigured phase currents and then current density distribution in stator slots under different open-circuit conditions are discussed.According to the developed model and postfault current density distribution,the steady-state electromagnetic performance,such as the electromagnetic torque and unbalanced magnetic force,under open-circuit faulty conditions are obtained.For validation purposes,finite element analysis(FEA)is employed to validate the analytical results.The result indicate that the postfault electromagnet performance can be accurately predicted by the proposed subdomain model,which is in good agreement with FEA results.展开更多
基金This work was supported in part by the National Natural Science Foundation of China under Grants 51677169 and 51637009.
文摘This paper presents a comparative investigation into unbalanced magnetic force(UMF)of asymmetric permanent magnet machines without rotor eccentricities,particularly focusing on the difference between internal-and external-rotor topologies.The asymmetric field distribution results in radial and tangential asymmetric force waves.Although the radial and tangential stresses are in different direction,the UMF components they produce are nearly aligned.The UMF from asymmetric radial force wave can be additive or subtractive to that from asymmetric tangential force wave.Investigation shows that for the same pole slot number combination,if the UMFs due to radial and tangential force waves are additive in internal rotor machine,they are subtractive in the external rotor counterpart,and vice versa.Investigation reveals a general rule determining whether additive or cancelling:for a UMF produced by any two field harmonics,they are additive if the higher order is produced by the outer part outside the airgap,but cancelling if the higher order is produced by the inner part.Therefore,for a machine with pole number 2p=3k+1,they are additive if it is an external-rotor machine,but otherwise subtractive.On the other hand,for a machine with pole number 2p=3k-1,they are subtractive if it is an external-rotor machine,but otherwise additive.For the UMF due to armature reaction only,they are subtractive for external-rotor machines,but otherwise additive.The investigation is carried out by an analytical model and validated by finite element analysis.
基金supported in part by National Natural Science Foundation of China(NSFC)under Project No.51737010in part by State Key Laboratory of Electrical Insulation and Power Equipment(EIPE19109)。
文摘The paper presents an accurate analytical subdomain model for predicting the electromagnetic performance in the symmetrical dual three-phase surface-mounted permanent magnet synchronous machine(PMSM)under open-phase faulty conditions.The model derivations are extended from previous accurate subdomain models accounting for slotting effects.Compared with most conventional subdomain models for traditional three-phase machines with nonoverlapping winding arrangement,the subdomain model proposed in this paper applied for the 24-slot/4-pole dual three-phase machine with symmetrical overlapping winding arrangement.In order to investigate the postfault electromagnetic performance,the reconfigured phase currents and then current density distribution in stator slots under different open-circuit conditions are discussed.According to the developed model and postfault current density distribution,the steady-state electromagnetic performance,such as the electromagnetic torque and unbalanced magnetic force,under open-circuit faulty conditions are obtained.For validation purposes,finite element analysis(FEA)is employed to validate the analytical results.The result indicate that the postfault electromagnet performance can be accurately predicted by the proposed subdomain model,which is in good agreement with FEA results.