A suitable bearing capacity of foundation is critical for the safety of civil structures.Sometimes foundation reinforcement is necessary and an effective and environmentally friendly method would be the preferred choi...A suitable bearing capacity of foundation is critical for the safety of civil structures.Sometimes foundation reinforcement is necessary and an effective and environmentally friendly method would be the preferred choice.In this study,the potential application of enzyme-induced carbonate precipitation(EICP)was investigated for reinforcing a 0.6 m bedding layer on top of clay to improve the bearing capacity of the foundation underneath an underground cable duct.Laboratory experiments were conducted to determine the optimal operational parameters for the extraction of crude urease liquid and optimal grain size range of sea sands to be used to construct the bedding layer.Field tests were planned based on orthogonal experimental design to study the factors that would significantly affect the biocementation effect on site.The dynamic deformation modulus,calcium carbonate content and longterm ground stress variations were used to evaluate the bio-cementation effect and the long-term performance of the EICP-treated bedding layer.The laboratory test results showed that the optimal duration for the extraction of crude urease liquid is 1 h and the optimal usage of soybean husk powder in urease extraction solution is 100 g/L.The calcium carbonate production rate decreases significantly when the concentration of cementation solution exceeds 0.5 mol/L.The results of site trial showed that the number of EICP treatments has the most significant impact on the effectiveness of EICP treatment and the highest dynamic deformation modulus(Evd)of EICP-treated bedding layer reached 50.55 MPa.The area with better bio-cementation effect was found to take higher ground stress which validates that the EICP treatment could improve the bearing capacity of foundation by reinforcing the bedding layer.The field trial described and the analysis introduced in this paper can provide a practical basis for applying EICP technology to the reinforcement of bedding layer in poor ground conditions.展开更多
The influence of thermal circuit parameters on a buried underground cable is investigated using an ANFIS (adaptive neuro-fuzzy inference system). Finite element solution of the heat conduction equation is used, comb...The influence of thermal circuit parameters on a buried underground cable is investigated using an ANFIS (adaptive neuro-fuzzy inference system). Finite element solution of the heat conduction equation is used, combined with artificial intelligence methods. The cable temperature depends on several parameters, such as the ambient temperature, the currents flowing through the conductor and the resistivity of the surrounding soil. In this paper, ANFIS is used to simulate the problem of the thermal field of underground cables under various parameters variation and climatic conditions. The developed model was trained using data generated from FEM (finite element method) for different configurations (training set) of the thermal field problem. After training, the system is tested for several scenarios, differing significantly from the training cases. It is shown that the proposed method is very time efficient and accurate in calculating the thermal fields compared to the relatively time consuming finite element method; thus ANFIS provides a potential computationally efficient and inexpensive predictive tool for more effective thermal design of underground cable systems.展开更多
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s...Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.展开更多
An analysis of underground power cables is performed using Fourier analysis with the objective of detecting fault and average life of the cables.Three types of cables are used in this experiment:a normal cable,a short...An analysis of underground power cables is performed using Fourier analysis with the objective of detecting fault and average life of the cables.Three types of cables are used in this experiment:a normal cable,a shorted cable, and a cable with holes.The impedance in each case is computed and Fourier transformation is applied so that the resulting impedance magnitude and impedance phase can be examined in the frequency domain.Various windowing techniques are applied to the experimental data to eliminate any interference.Fourier analysis is then applied to the impedance data calculated from both the sending end voltage and differential voltage.This analysis reveals differences in the frequency response of the three different types of a cable and can eventually be used as a measure for fault detection. Preliminary results reveal the differences in the frequency response.Accordingly,Fourier type methods can be effectively used as low cost and viable solutions to identify and detect faults in underground cables.展开更多
One of the factors that affect the parameters of an underground cable is earth return path impedance.Pollaczek developed a formula for the case of one-layer(homogenous) earth.But in practice the earth is composed of s...One of the factors that affect the parameters of an underground cable is earth return path impedance.Pollaczek developed a formula for the case of one-layer(homogenous) earth.But in practice the earth is composed of several layers.In this study we develop a new formula for earth return path impedance in the case of a three-layer earth.To check the accuracy of the obtained results,a comparison has been made with the finite element method(FEM).A comparison between the results of the Pollaczek formula and results of the obtained formula for a three-layer earth has been made,showing that the use of the Pollaczek formula instead of the actual formula can cause serious errors.展开更多
基金The authors gratefully acknowledge the financial support of National Natural Science Foundation of China(Grant No.41972276)Natural Science Foundation of Fujian Province(Grant No.2020J06013)“Foal Eagle Program”Youth Top-notch Talent Project of Fujian Province,China(Grant No.00387088).
文摘A suitable bearing capacity of foundation is critical for the safety of civil structures.Sometimes foundation reinforcement is necessary and an effective and environmentally friendly method would be the preferred choice.In this study,the potential application of enzyme-induced carbonate precipitation(EICP)was investigated for reinforcing a 0.6 m bedding layer on top of clay to improve the bearing capacity of the foundation underneath an underground cable duct.Laboratory experiments were conducted to determine the optimal operational parameters for the extraction of crude urease liquid and optimal grain size range of sea sands to be used to construct the bedding layer.Field tests were planned based on orthogonal experimental design to study the factors that would significantly affect the biocementation effect on site.The dynamic deformation modulus,calcium carbonate content and longterm ground stress variations were used to evaluate the bio-cementation effect and the long-term performance of the EICP-treated bedding layer.The laboratory test results showed that the optimal duration for the extraction of crude urease liquid is 1 h and the optimal usage of soybean husk powder in urease extraction solution is 100 g/L.The calcium carbonate production rate decreases significantly when the concentration of cementation solution exceeds 0.5 mol/L.The results of site trial showed that the number of EICP treatments has the most significant impact on the effectiveness of EICP treatment and the highest dynamic deformation modulus(Evd)of EICP-treated bedding layer reached 50.55 MPa.The area with better bio-cementation effect was found to take higher ground stress which validates that the EICP treatment could improve the bearing capacity of foundation by reinforcing the bedding layer.The field trial described and the analysis introduced in this paper can provide a practical basis for applying EICP technology to the reinforcement of bedding layer in poor ground conditions.
文摘The influence of thermal circuit parameters on a buried underground cable is investigated using an ANFIS (adaptive neuro-fuzzy inference system). Finite element solution of the heat conduction equation is used, combined with artificial intelligence methods. The cable temperature depends on several parameters, such as the ambient temperature, the currents flowing through the conductor and the resistivity of the surrounding soil. In this paper, ANFIS is used to simulate the problem of the thermal field of underground cables under various parameters variation and climatic conditions. The developed model was trained using data generated from FEM (finite element method) for different configurations (training set) of the thermal field problem. After training, the system is tested for several scenarios, differing significantly from the training cases. It is shown that the proposed method is very time efficient and accurate in calculating the thermal fields compared to the relatively time consuming finite element method; thus ANFIS provides a potential computationally efficient and inexpensive predictive tool for more effective thermal design of underground cable systems.
文摘Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.
文摘An analysis of underground power cables is performed using Fourier analysis with the objective of detecting fault and average life of the cables.Three types of cables are used in this experiment:a normal cable,a shorted cable, and a cable with holes.The impedance in each case is computed and Fourier transformation is applied so that the resulting impedance magnitude and impedance phase can be examined in the frequency domain.Various windowing techniques are applied to the experimental data to eliminate any interference.Fourier analysis is then applied to the impedance data calculated from both the sending end voltage and differential voltage.This analysis reveals differences in the frequency response of the three different types of a cable and can eventually be used as a measure for fault detection. Preliminary results reveal the differences in the frequency response.Accordingly,Fourier type methods can be effectively used as low cost and viable solutions to identify and detect faults in underground cables.
文摘One of the factors that affect the parameters of an underground cable is earth return path impedance.Pollaczek developed a formula for the case of one-layer(homogenous) earth.But in practice the earth is composed of several layers.In this study we develop a new formula for earth return path impedance in the case of a three-layer earth.To check the accuracy of the obtained results,a comparison has been made with the finite element method(FEM).A comparison between the results of the Pollaczek formula and results of the obtained formula for a three-layer earth has been made,showing that the use of the Pollaczek formula instead of the actual formula can cause serious errors.