A Fault Feature Extraction Model in Synchronous Generator under Stator Inter-Turn Short Circuit Based on ACMD and DEO3S 被引量:1
1
作者 Yuling He Shuai Li +1 位作者 Chao Zhang Xiaolong Wang 《Structural Durability & Health Monitoring》 EI 2023年第2期115-130,共16页
This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fa... This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model. 展开更多
关键词 Synchronous generator stator inter-turn short circuit vibration signal processing adaptive chirp mode decomposition demodulation energy operator of symmetrical differencing
下载PDF
A fault warning for inter-turn short circuit of excitation winding of synchronous generator based on GRU-CNN 被引量:4
2
作者 Junqing Li Jing Liu Yating Chen 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期236-248,共13页
Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding ... Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally. 展开更多
关键词 Synchronous generator inter-turn short circuit Excitation winding Fault warning GRU-CNN IPSO
下载PDF
The Detection of Inter-Turn Short Circuits in the Stator Windings of Sensorless Operating Induction Motors
3
作者 Jean Blaise Teguia Godpromesse Kenne +2 位作者 Alain Tewa Soup Kammogne Georges Collince Fouokeng Arnaud Nanfak 《World Journal of Engineering and Technology》 2021年第3期653-681,共29页
This work proposes an alternative strategy to the use of a speed sensor in <span style="white-space:normal;font-size:10pt;font-family:;" "="">the implementation of active and reactive po... This work proposes an alternative strategy to the use of a speed sensor in <span style="white-space:normal;font-size:10pt;font-family:;" "="">the implementation of active and reactive power based model reference adaptive system (PQ-MRAS) estimator in order to calculate the rotor and stator resistances of an induction motor (IM) and the use of these parameters for the detection of inter-turn short circuits (ITSC) faults in the stator of this motor. The rotor and stator resistance estimation part of the IM is performed by the PQ-MRAS method in which the rotor angular velocity is reconstructed from the interconnected high gain observer (IHGO). The ITSC fault detection part is done by the derivation of stator resistance estimated by the PQ-</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">MRAS estimator. In addition to the speed sensorless detection of ITSC faults of the IM, an approach to determine the number of shorted turns based on the difference between the phase current of the healthy and faulty machine is proposed. Simulation results obtained from the MATLAB/Simulink platform have shown that the PQ-MRAS estimator using an interconnected high-</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">gain observer gives very similar results to those using the speed sensor. The </span><span style="white-space:normal;font-size:10pt;font-family:;" "="">estimation errors in the cases of speed variation and load torque are al</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">mos</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">t identical. Variations in stator and rotor resistances influence the per</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">formance of the observer and lead to poor estimation of the rotor resistance. The results of ITSC fault detection using IHGO are very similar to the results in the literature using the same diagnostic approach with a speed sensor.</span> 展开更多
关键词 inter-turn short circuits Active and Reactive Power Based Model Reference Adaptive System Interconnected High Gain Observer Fault Detection
下载PDF
Simplified mathematical model of inter-turn short circuit of field windings in hydro-generators and its application 被引量:5
4
作者 HAO LiangLiang WU JunYong +1 位作者 SUN YuGuang WANG XiangHeng 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第4期898-909,共12页
Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers o... Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering application.To deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment method.Through the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the stator.The calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original model.Moreover,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault monitoring.Finally,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is depicted.The result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity. 展开更多
关键词 HYDRO-GENERATOR field windings inter-turn short circuit simplified model on-line monitoring
原文传递
Application of Morphological Max-Lifting Scheme for Identification of Induction Motor Stator Inter-turn Short Circuit 被引量:2
5
作者 Yin Zhang Tianyao Ji +1 位作者 Mengshi Li Q.H.Wu 《CSEE Journal of Power and Energy Systems》 SCIE 2015年第4期92-100,共9页
The harmonic components of stator winding current in induction motor will change under the condition of stator inter-turn short circuit.According to these characteristics,in this paper,a novel technique based on morph... The harmonic components of stator winding current in induction motor will change under the condition of stator inter-turn short circuit.According to these characteristics,in this paper,a novel technique based on morphological maxlifting scheme is proposed for identification of induction motor stator inter-turn short circuit.A max-lifting scheme is applied to process stator winding currents to extract these characteristics.An indicator,r,is computed to identify the short circuit.The transient model of induction motor is employed to simulate oneturn to six-turn stator inter-turn short circuits in an induction motor.Extensive simulation work has been conducted under normal conditions,abnormal conditions(voltage imbalance and varying load),stator inter-turn short circuit conditions,and conditions of any combinations of the above.The results have shown that the scheme proposed in this paper has a high identification rate for induction motor stator inter-turn short circuit. 展开更多
关键词 Identification induction motor inter-turn short circuit mathematical morphology max-lifting scheme varying load voltage imbalance
原文传递
一起基于重复脉冲法的发电机转子绕组匝间短路故障分析
6
作者 潘剑南 李浩良 《黑龙江电力》 CAS 2022年第5期402-406,410,共6页
阐述一起发电机转子绕组匝间短路故障,在直流电阻测量、极间电压试验和交流阻抗及功率损耗试验均未能有效诊断出故障的情况下,通过静态多角度的重复脉冲法试验,诊断出转子绕组存在和轴体角度有关系的不稳定匝间短路故障。转子抽出定子... 阐述一起发电机转子绕组匝间短路故障,在直流电阻测量、极间电压试验和交流阻抗及功率损耗试验均未能有效诊断出故障的情况下,通过静态多角度的重复脉冲法试验,诊断出转子绕组存在和轴体角度有关系的不稳定匝间短路故障。转子抽出定子膛外后,进行了交流电压分布试验,试验结果表明转子绕组存在匝间短路故障。转子返厂解体发现的匝间短路故障位置与重复脉冲法试验结果一致,验证了重复脉冲法试验诊断转子绕组不稳定匝间短路的有效性和准确性。 展开更多
关键词 发电机 转子绕组 不稳定匝间短路 重复脉冲法 故障诊断
下载PDF
Stator Fault Diagnosis of Induction Motor Based on Discrete Wavelet Analysis and Neural Network Technique 被引量:2
7
作者 Abdelelah Almounajjed Ashwin Kumar Sahoo +1 位作者 Mani Kant Kumar Sanjeet Kumar Subudhi 《Chinese Journal of Electrical Engineering》 CSCD 2023年第1期142-157,共16页
A novel approach by introducing a statistical parameter to estimate the severity of incipient stator inter-turn short circuit(ITSC)faults in induction motors(IMs)is proposed.Determining the incipient ITSC fault and it... A novel approach by introducing a statistical parameter to estimate the severity of incipient stator inter-turn short circuit(ITSC)faults in induction motors(IMs)is proposed.Determining the incipient ITSC fault and its severity is challenging for several reasons.The stator currents in the healthy and faulty cases are highly similar during the primary stage of the fault.Moreover,the conventional statistical parameters resulting from the analysis of fault signals do not consistently show a systematic variation with respect to the increase in fault intensity.The objective of this study is the early detection of incipient ITSC faults.Furthermore,it aims to determine the percentage of shorted turns in the faulty phase,which acts as an indicator for severe damage to the stator winding.Modeling of the motor in healthy and defective cases is performed using the Clarke Concordia transform.A discrete wavelet transform is applied to the motor currents using a Daubechies-8 wavelet.The statistical parameters L1 and L2 norms are computed for the detailed coefficients.These parameters are obtained under a variety of loads and defects to acquire the most accurate and generalized features related to the fault.Combining L1 and L2 norms creates a novel statistical parameter with notable characteristics to achieve the research aim.An artificial neural network-based back propagation algorithm is employed as a classifier to implement the classification process.The classifier output defines the percentage of defective turns with a high level of accuracy.The competency of the adopted methodology is validated via simulations and experiments.The results confirm the merits of the proposed method,with a classification test correctness of 95.29%. 展开更多
关键词 Discrete wavelet transform induction motor inter-turn short circuit fault neural networks statistical parameters
原文传递