With the advantages of high combustion efficiency, wide fuel flexibility and low concentrations of discharged pollutants, circulating fluid- ized bed (CFB) boiler has been widely used in recent years. However, in or...With the advantages of high combustion efficiency, wide fuel flexibility and low concentrations of discharged pollutants, circulating fluid- ized bed (CFB) boiler has been widely used in recent years. However, in order to meet the requirement of new emission standard, it's necessary to add flue gas desulfurization and denitration devices. In this paper, the choice of flue gas purification processes for CFB boiler has been discussed firstly, and then the economy and rationality of the SNCR + CFB-FGD + COA comprehensive solution to flue gas desulfurization and denitration have been analyzed.展开更多
An experimental investigation is performed on side wall deformation at the pendant convective pass (PCP) in a 300 MW and a 600 MW utility boiler. The temperature distributions are measured on the side wall areas of th...An experimental investigation is performed on side wall deformation at the pendant convective pass (PCP) in a 300 MW and a 600 MW utility boiler. The temperature distributions are measured on the side wall areas of the water-cooled wall, the PCP and the horizontal convective pass (HCP) in the two utility boilers. These experiments show that there are great temperature differences in the side wall areas during the startup process in both utility boilers. These temperature differences can reach 80~150 °C with the side wall temperature in the PCP area higher than those in the water-cooled wall and the HCP. The highest temperature in the PCP is close to the flue gas side temperature at the same position in the horizontal flue gas pass. Thermal stress analyses are conducted in the side wall areas in the water-cooled wall, the PCP and the HCP with the software ANSYS. The results show that, at great temperature differences, the PCP side wall undergoes negative thermal stresses that exceed the yield strength causing deformation in the PCP side wall.展开更多
Since the first batch of 350-MW supercritical utility boilers was put into operation, the exhaust flue gas temperature of the boilers has always been higher than the designed value. The main reason is that the heat ab...Since the first batch of 350-MW supercritical utility boilers was put into operation, the exhaust flue gas temperature of the boilers has always been higher than the designed value. The main reason is that the heat absorbed by the air heater is not sufficient. In Huaneng Dongfang Power Plant, the exhaust flue gas temperature is lowered through modifications to the economizer and the air heater. The experimental results reveal that every year, each boiler could save 3 850 tons of standard coal and reduce 85 tons of SO2 and 9 000 tons of CO2 respectively after retrofit.展开更多
基金Supported by the National High Technology Research and Develop-ment Program of China(863 Program)(2013AA065403)Major Sci-ence and Technology Project of Fujian Province,China(2011HZ0005-1)+1 种基金International Science and Technology CooperationProgram(2010DFB93990)Natural Science Foundation of FujianProvince,China(2014J06020)
文摘With the advantages of high combustion efficiency, wide fuel flexibility and low concentrations of discharged pollutants, circulating fluid- ized bed (CFB) boiler has been widely used in recent years. However, in order to meet the requirement of new emission standard, it's necessary to add flue gas desulfurization and denitration devices. In this paper, the choice of flue gas purification processes for CFB boiler has been discussed firstly, and then the economy and rationality of the SNCR + CFB-FGD + COA comprehensive solution to flue gas desulfurization and denitration have been analyzed.
基金supported by Program for Changjiang Scholars and Innovative Research Team in University (No. PCSIRT0720)the Overseas Returnee Scholar Foundation of North China Electric Power University, China
文摘An experimental investigation is performed on side wall deformation at the pendant convective pass (PCP) in a 300 MW and a 600 MW utility boiler. The temperature distributions are measured on the side wall areas of the water-cooled wall, the PCP and the horizontal convective pass (HCP) in the two utility boilers. These experiments show that there are great temperature differences in the side wall areas during the startup process in both utility boilers. These temperature differences can reach 80~150 °C with the side wall temperature in the PCP area higher than those in the water-cooled wall and the HCP. The highest temperature in the PCP is close to the flue gas side temperature at the same position in the horizontal flue gas pass. Thermal stress analyses are conducted in the side wall areas in the water-cooled wall, the PCP and the HCP with the software ANSYS. The results show that, at great temperature differences, the PCP side wall undergoes negative thermal stresses that exceed the yield strength causing deformation in the PCP side wall.
文摘Since the first batch of 350-MW supercritical utility boilers was put into operation, the exhaust flue gas temperature of the boilers has always been higher than the designed value. The main reason is that the heat absorbed by the air heater is not sufficient. In Huaneng Dongfang Power Plant, the exhaust flue gas temperature is lowered through modifications to the economizer and the air heater. The experimental results reveal that every year, each boiler could save 3 850 tons of standard coal and reduce 85 tons of SO2 and 9 000 tons of CO2 respectively after retrofit.