Objective To assess the test-retest reliability and criterion validity of the Simplified Chinese-character version of the International Physical Activity Questionnaire Long form (IPAC).-L) in urban community-dwelli...Objective To assess the test-retest reliability and criterion validity of the Simplified Chinese-character version of the International Physical Activity Questionnaire Long form (IPAC).-L) in urban community-dwelling adults in Hanghzou, China. Methods A total of 158 eligible participants aged 25-59 years from 6 neighbourhoods in two central districts of Hangzhou completed the IPAQ-L questionnaire twice within a 7-day interval. Half of the subjects wore pedometers during the first 7 days. Test-retest reliability was examined by comparing the first (Day 1) and the second (Day 9) survey of IPAQ-L Criterion validity was assessed by comparing IPAO,-L with pedometer data. Results Modest to good test-retest reliability was found with intraclass correlation coefficients of 0.67 for total PA, 0.37 to 0.73 for specific dimensions, and 0.56 to 0.71 for different intensities of PA. Total PA measured by IPAO.-L was moderately correlated with exercise levels (partial r = 0.27, P = 0.020) and walking distance (partial r = 0.31, P = 0.007), which were measured by a pedometer, after adjusting for gender, age, educational attainment and employment status. Conclusion Our results indicate that the IPAO.-L is a reliable and validated measure for assessing physica activity levels in this population and possibly the adult population in other mainland Chinese cities.展开更多
An isocratic reverse phase liquid chromatography (RP-LC) method has been developed and subsequently validated for the determination of Ranolazine in Bulk and its pharmaceutical formulation. Separation was achieved wit...An isocratic reverse phase liquid chromatography (RP-LC) method has been developed and subsequently validated for the determination of Ranolazine in Bulk and its pharmaceutical formulation. Separation was achieved with a X-terra RP-18 ((Make: Waters Corporation;150 mm × 4.6 mm I.D.;particle size 5 μm)) Column and Sodium di-hydrogen phosphate monohydrate buffer with Tri ethyl amine (pH adjusted to 5.0 with diluted orthophosphoric acid): Acetonitrile (600:400) v/v as eluent at a flow rate of 1.0 mL/min. UV detection was performed at 225 nm. The method is simple, rapid, and selective. The described method of Ranolazine is linear over a range of 11.98 μg/mL to 37.92 μg/mL. The method precision for the determination of assay was below 1.0%RSD. The percentage recoveries of active pharmaceutical ingredient (API) from dosage forms ranged from 99.1% to 100.9%. The results showed that the proposed method is suitable for the precise, accurate and rapid determination of Ranolazine in bulk, its capsule dosage forms.展开更多
A simple efficient isocratic reversed-phase HPLC method was developed and validated for the determination of clindamycin palmitate hydrochloride (CPH) and its commercially available oral solution products. Separation ...A simple efficient isocratic reversed-phase HPLC method was developed and validated for the determination of clindamycin palmitate hydrochloride (CPH) and its commercially available oral solution products. Separation was achieved on a Phenomenex Zorbax (Luna) cyano column (150 × 4.6 mm, 5 μm) with a Phenomenex cyano guard cartridge (4 × 3.0 mm) on Agilent 1050 series HPLC system. CPH and its resolution standard lincomycin were eluted isocratically at a flow rate of 1 mL/min with a simplified mobile phase (potassium phosphate buffer (5 mM, pH 3.0)—acetonitrile—tetrahydrofuran (20:75:5, v/v/v)) and detected at 210 nm. The column was maintained at 25?C. The method was validated according to USP category I requirements. Robustness and forced degradation studies were also conducted. CPH marketed drug products were obtained from a drug distributor and assayed for potency using the validated method. Validation acceptance criteria were met in all cases. The analytical range for CPH was 15 - 500 μg/mL and the linearity was r2 > 0.999 over three days. The method was determined to be specific and robust. Both accuracy (92.0% - 103.8%) and precision (0.67% - 1.52%) were established across the analytical range for low, intermediate and high QC concentrations. Method applicability was demonstrated by analyzing two marketed products of CPH, in which results showed potency >98%. The method was determined to be an enhancement over the current USP methodology for assay as a result of increased efficiency, reduced organic solvents and the elimination of matrix modifiers. This method was successfully applied for the quality assessment of: 1) currently marketed drug products and 2) will in future assess the product quality of novel dosage forms of CPH for pediatric use.展开更多
基金supported by the National Nature Science Foundation of China(No.81072373)the Health Science and Technology Planning Key Project of Hangzhou City(No.HWS2011Z017)
文摘Objective To assess the test-retest reliability and criterion validity of the Simplified Chinese-character version of the International Physical Activity Questionnaire Long form (IPAC).-L) in urban community-dwelling adults in Hanghzou, China. Methods A total of 158 eligible participants aged 25-59 years from 6 neighbourhoods in two central districts of Hangzhou completed the IPAQ-L questionnaire twice within a 7-day interval. Half of the subjects wore pedometers during the first 7 days. Test-retest reliability was examined by comparing the first (Day 1) and the second (Day 9) survey of IPAQ-L Criterion validity was assessed by comparing IPAO,-L with pedometer data. Results Modest to good test-retest reliability was found with intraclass correlation coefficients of 0.67 for total PA, 0.37 to 0.73 for specific dimensions, and 0.56 to 0.71 for different intensities of PA. Total PA measured by IPAO.-L was moderately correlated with exercise levels (partial r = 0.27, P = 0.020) and walking distance (partial r = 0.31, P = 0.007), which were measured by a pedometer, after adjusting for gender, age, educational attainment and employment status. Conclusion Our results indicate that the IPAO.-L is a reliable and validated measure for assessing physica activity levels in this population and possibly the adult population in other mainland Chinese cities.
文摘An isocratic reverse phase liquid chromatography (RP-LC) method has been developed and subsequently validated for the determination of Ranolazine in Bulk and its pharmaceutical formulation. Separation was achieved with a X-terra RP-18 ((Make: Waters Corporation;150 mm × 4.6 mm I.D.;particle size 5 μm)) Column and Sodium di-hydrogen phosphate monohydrate buffer with Tri ethyl amine (pH adjusted to 5.0 with diluted orthophosphoric acid): Acetonitrile (600:400) v/v as eluent at a flow rate of 1.0 mL/min. UV detection was performed at 225 nm. The method is simple, rapid, and selective. The described method of Ranolazine is linear over a range of 11.98 μg/mL to 37.92 μg/mL. The method precision for the determination of assay was below 1.0%RSD. The percentage recoveries of active pharmaceutical ingredient (API) from dosage forms ranged from 99.1% to 100.9%. The results showed that the proposed method is suitable for the precise, accurate and rapid determination of Ranolazine in bulk, its capsule dosage forms.
文摘A simple efficient isocratic reversed-phase HPLC method was developed and validated for the determination of clindamycin palmitate hydrochloride (CPH) and its commercially available oral solution products. Separation was achieved on a Phenomenex Zorbax (Luna) cyano column (150 × 4.6 mm, 5 μm) with a Phenomenex cyano guard cartridge (4 × 3.0 mm) on Agilent 1050 series HPLC system. CPH and its resolution standard lincomycin were eluted isocratically at a flow rate of 1 mL/min with a simplified mobile phase (potassium phosphate buffer (5 mM, pH 3.0)—acetonitrile—tetrahydrofuran (20:75:5, v/v/v)) and detected at 210 nm. The column was maintained at 25?C. The method was validated according to USP category I requirements. Robustness and forced degradation studies were also conducted. CPH marketed drug products were obtained from a drug distributor and assayed for potency using the validated method. Validation acceptance criteria were met in all cases. The analytical range for CPH was 15 - 500 μg/mL and the linearity was r2 > 0.999 over three days. The method was determined to be specific and robust. Both accuracy (92.0% - 103.8%) and precision (0.67% - 1.52%) were established across the analytical range for low, intermediate and high QC concentrations. Method applicability was demonstrated by analyzing two marketed products of CPH, in which results showed potency >98%. The method was determined to be an enhancement over the current USP methodology for assay as a result of increased efficiency, reduced organic solvents and the elimination of matrix modifiers. This method was successfully applied for the quality assessment of: 1) currently marketed drug products and 2) will in future assess the product quality of novel dosage forms of CPH for pediatric use.