期刊文献+
共找到7,755篇文章
< 1 2 250 >
每页显示 20 50 100
Bunch-length measurement at a bunch-by-bunch rate based on time–frequency-domain joint analysis techniques and its application
1
作者 Hong-Shuang Wang Xing Yang +2 位作者 Yong-Bin Leng Yi-Mei Zhou Ji-Gang Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期165-175,共11页
This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si... This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings. 展开更多
关键词 Bunch-by-bunch diagnostic Bunch-length measurement Synchronous phase measurement Joint time–frequency-domain analysis Longitudinal instability
下载PDF
Semi-empirical modeling of volumetric efficiency in engines equipped with variable valve timing system 被引量:1
2
作者 Mostafa Ghajar Amir Hasan Ka Kaee Behrooz Mashadi 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第12期3132-3142,共11页
Volumetric efficiency and air charge estimation is one of the most demanding tasks in control of today's internal combustion engines.Specifically,using three-way catalytic converter involves strict control of the ... Volumetric efficiency and air charge estimation is one of the most demanding tasks in control of today's internal combustion engines.Specifically,using three-way catalytic converter involves strict control of the air/fuel ratio around the stoichiometric point and hence requires an accurate model for air charge estimation.However,high degrees of complexity and nonlinearity of the gas flow in the internal combustion engine make air charge estimation a challenging task.This is more obvious in engines with variable valve timing systems in which gas flow is more complex and depends on more functional variables.This results in models that are either quite empirical(such as look-up tables),not having interpretability and extrapolation capability,or physically based models which are not appropriate for onboard applications.Solving these problems,a novel semi-empirical model was proposed in this work which only needed engine speed,load,and valves timings for volumetric efficiency prediction.The accuracy and generalizability of the model is shown by its test on numerical and experimental data from three distinct engines.Normalized test errors are 0.0316,0.0152 and 0.24 for the three engines,respectively.Also the performance and complexity of the model were compared with neural networks as typical black box models.While the complexity of the model is less than half of the complexity of neural networks,and its computational cost is approximately 0.12 of that of neural networks and its prediction capability in the considered case studies is usually more.These results show the superiority of the proposed model over conventional black box models such as neural networks in terms of accuracy,generalizability and computational cost. 展开更多
关键词 engine modeling modeling and simulation spark ignition engine volumetric efficiency variable valve timing
下载PDF
Review of low timing jitter mode-locked fiber lasers and applications in dual-comb absolute distance measurement 被引量:10
3
作者 Haosen Shi Youjian Song +6 位作者 Runmin Li Yuepeng Li Hui Cao Haochen Tian Bowen Liu Lu Chai Minglie Hu 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2018年第4期205-217,共13页
Passively mode-locked fiber lasers emit femtosecond pulse trains with excellent short-term stability. The quantum-limited timing jitter of a free running femtosecond erbium-doped fiber laser working at room temperatur... Passively mode-locked fiber lasers emit femtosecond pulse trains with excellent short-term stability. The quantum-limited timing jitter of a free running femtosecond erbium-doped fiber laser working at room temperature is considerably below one femtosecond at high Fourier frequency. The ultrashort pulse train with ultralow timing jitter enables absolute time-of-flight measurements based on a dual-comb implementation, which is typically composed of a pair of optical frequency combs generated by femtosecond lasers. Dead-zone-free absolute distance measurement with sub-micrometer precision and kHz update rate has been routinely achieved with a dual-comb configuration, which is promising for a number of precision manufacturing applications, from large step-structure measurements prevalent in microelectronic profilometry to three coordinate measurements in large-scale aerospace manufacturing and shipbuilding. In this paper, we first review the sub-femtosecond precision timing jitter characterization methods and approaches for ultralow timing jitter mode-locked fiber laser design. Then, we provide an overview of the state-of-the-art dual-comb absolute ranging technology in terms of working principles, experimental implementations, and measurement precisions. Finally, we discuss the impact of quantum-limited timing jitter on the dual-comb ranging precision at a high update rate. The route to highprecision dual-comb range finder design based on ultralow jitter femtosecond fiber lasers is proposed. 展开更多
关键词 timing JITTER MODE-LOCKED lasers Dual-comb ABSOLUTE distance measurement
下载PDF
Gear Drive Mechanism for Continuous Variable Valve Timing of IC Engines
4
作者 Osama H. M. Ghazal Mohamad S. H. Dado 《Engineering(科研)》 2013年第3期245-250,共6页
Continuous variable valve actuating (CVVA) technology provides high potential in achieving high performance, low fuel consumption and pollutant reduction. To get full benefits from (CVVT) various types of mechanisms h... Continuous variable valve actuating (CVVA) technology provides high potential in achieving high performance, low fuel consumption and pollutant reduction. To get full benefits from (CVVT) various types of mechanisms have been proposed and designed. Some of these mechanisms are in production and have shown significant benefits in improving engine performance. In this investigation a newly designed gear drive mechanism that controls the intake valve opening (IVO) and closing (IVC) angles is studied. The control scheme is based on maximizing the engine brake power (P) and specific fuel consumption (BSFC) at any engine speed by continuously varying the phase between the cam shaft angle and the crank shaft angle. A single-cylinder engine is simulated by the “LOTUS” software to find out the optimum phase angle for maximum power and minimum fuel consumption at a given engine speed. The mechanism is a planetary gear drive designed for precise and continuous control. This mechanism has a simple design and operation conditions which can change the phase angle without limitation. 展开更多
关键词 Mechanism Design PLANETARY GEAR Variable valve timing Spark IGNITION Engines Performance
下载PDF
A Measurement Study of the Ethereum Underlying P2P Network
5
作者 Mohammad ZMasoud Yousef Jaradat +3 位作者 Ahmad Manasrah Mohammad Alia Khaled Suwais Sally Almanasra 《Computers, Materials & Continua》 SCIE EI 2024年第1期515-532,共18页
This work carried out a measurement study of the Ethereum Peer-to-Peer(P2P)network to gain a better understanding of the underlying nodes.Ethereum was applied because it pioneered distributed applications,smart contra... This work carried out a measurement study of the Ethereum Peer-to-Peer(P2P)network to gain a better understanding of the underlying nodes.Ethereum was applied because it pioneered distributed applications,smart contracts,and Web3.Moreover,its application layer language“Solidity”is widely used in smart contracts across different public and private blockchains.To this end,we wrote a new Ethereum client based on Geth to collect Ethereum node information.Moreover,various web scrapers have been written to collect nodes’historical data fromthe Internet Archive and the Wayback Machine project.The collected data has been compared with two other services that harvest the number of Ethereumnodes.Ourmethod has collectedmore than 30% more than the other services.The data trained a neural network model regarding time series to predict the number of online nodes in the future.Our findings show that there are less than 20% of the same nodes daily,indicating thatmost nodes in the network change frequently.It poses a question of the stability of the network.Furthermore,historical data shows that the top ten countries with Ethereum clients have not changed since 2016.The popular operating system of the underlying nodes has shifted from Windows to Linux over time,increasing node security.The results have also shown that the number of Middle East and North Africa(MENA)Ethereum nodes is neglected compared with nodes recorded from other regions.It opens the door for developing new mechanisms to encourage users from these regions to contribute to this technology.Finally,the model has been trained and demonstrated an accuracy of 92% in predicting the future number of nodes in the Ethereum network. 展开更多
关键词 Ethereum measurement ethereum client neural network time series forecasting web-scarping wayback machine blockchain
下载PDF
TIME-SPACE CONCEPT FOR PRECISION MEASUREMENT 被引量:4
6
作者 LIU Xiaokang PENG Donglin ZHU Ge WANG Xianquan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第3期112-115,共4页
The transformation between time and space is discussed. To improve real-time response speed of intelligent measuring system, the concept of exchanging program execution time with more circuitry is presented working in... The transformation between time and space is discussed. To improve real-time response speed of intelligent measuring system, the concept of exchanging program execution time with more circuitry is presented working in cycle mode. Displacement measuring by magnification is achieved with period measurement by magnification. To change the condition that traditional precision measurement depends on machining precision greatly, the concept of measuring space with time and theory of time-space coordinate transformation are proposed. Guided by the idea of measuring space with time, differential frequency measurement system and time grating displacement sensor are developed based on the proposed novel methods. And high-precision measurement is achieved without high-precision manufacture, which embeds the remarkable characteristics of low cost but high precision to the devices. Experiment and test results conform the validity of the proposed time-space concept. 展开更多
关键词 Time-space Precision measurement Control flow Differential frequency Time grating
下载PDF
Noise analysis and measurement of time delay and integration charge coupled device 被引量:4
7
作者 王德江 张涛 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期348-353,共6页
Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp... Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs. 展开更多
关键词 time delay and integration charge coupled device noise measurement remote sensingapplication
下载PDF
Simultaneous measurements of global vibrational spectra and dephasing times of molecular vibrational modes by broadband time-resolved coherent anti-Stokes Raman scattering spectrography 被引量:2
8
作者 尹君 于凌尧 +3 位作者 刘星 万辉 林子扬 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期385-391,共7页
In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of variou... In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of various spectral components of SC in an enough bandwidth. By numerical simulations, the optimal experimental conditions for improving the SC are obtained. The broadband time-resolved CARS spectrography based on the SC with required temporal and spectral distributions is realised. The global molecular vibrational spectrum with well suppressed nonresonant background noise can be obtained in a single measurement. At the same time, the measurements of dephasing times of various molecular vibrational modes can be conveniently achieved from intensities of a sequence of time-resolved CARS signals. It will be more helpful to provide a complete picture of molecular vibrations, and to exhibit a potential to understand not only both the solvent dynamics and the solute-solvent interactions, but also the mechanisms of chemical reactions in the fields of biology, chemistry and material science. 展开更多
关键词 coherent anti-Stokes Raman scattering photonic crystal fibre SUPERCONTINUUM molecular vibrational spectrum dephasing time time-resolved measurement
下载PDF
Precise measurement method of optical fiber length based on timestamp technique
9
作者 缪新育 周波 周峰 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第3期302-306,共5页
A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchr... A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchronization time deviation is used, and the difference between two-path delays could be deduced by measuring the synchronization time deviation reversely. Then the length of optical fiber on one path could be calculated if that on the other path is known Due to the fact that the path of Sync and Delay_Req message is symmetric, the optical pulse dispersion and the asymmetry of photoelectric detector performance on two paths are averaged by exchanging two optical fibers. The time difference between master and slave clocks is eliminated by sharing the same time base. At last, the lengths of two single-mode optical fibers are measured with the uncertainty of 0. 578 m for 3 227. 722 m and 0. 758 m for 25 491. 522 m, respectively. Thus this method has high precision and long range. 展开更多
关键词 TIMESTAMP fiber length measurement time synchronization
下载PDF
Vibrations measurements for shrouded blades of steam turbines based oneddy current sensors with high frequency response 被引量:4
10
作者 YE De-chao DUAN Fa-jie +3 位作者 ZHOU Qi CHENG Zhong-hai LI Xu NIU Guang-yue 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第4期315-321,共7页
With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the uns... With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the unstable operating conditions brought by flexible operation.A vibration measuring method for the shrouded blades of a steam turbine based on eddy current sensors with high frequency response is proposed,meeting the requirements of non-contact heath monitoring.The eddy current sensors produce the signals which are related to the area changing of every blade’s shroud resulting from the rotation of stator.Then an improved blade tip timing(BTT)technique is proposed to detect the vibrations of shrouded blades by measuring the arrival time of each area changing signal.A structure of eddy current sensors is developed in steam turbines and an amplitude modulation/demodulation circuit is designed to improve the response bandwidth up to 250 kHz.Vibration tests for the last stage blades of a steam turbine were carried out and the results validate the efficiency of the improved BTT technique and the high frequency response of the eddy current sensors presented. 展开更多
关键词 steam turbine blade vibration measurement eddy current sensor blade tip timing
下载PDF
Digital image stabilization system based on inertial measurement module 被引量:1
11
作者 金锋 李田 《Journal of Beijing Institute of Technology》 EI CAS 2013年第2期222-227,共6页
In order to stabilize the video module to build digital image stabilization image sequence, a method of using inertial measurement system is proposed. Through applying real-time attitude in- formation of the camera th... In order to stabilize the video module to build digital image stabilization image sequence, a method of using inertial measurement system is proposed. Through applying real-time attitude in- formation of the camera that obtained by high-precision attitude sensor to estimate the image motion vector and then to compensate for image, the purpose of stabilizing the image sequence can be a- chieved. Experiments demonstrate that this method has a high image stabilization precision, and the up to 16 frame/s video output rate completely meets the real-time requirements. 展开更多
关键词 inertial measurement module digital image stabilization system motion vector real- time
下载PDF
FPGA-based High-precision Measurement Algorithm for the Ultrasonic Echo Time of Flight 被引量:3
12
作者 王伯雄 张金 《Journal of Measurement Science and Instrumentation》 CAS 2010年第2期103-107,共5页
Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the req... Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the requirements for the measurement of echo time of flight put forward by the ultrasonic flow measurement are analyzed. A new high-precision time interval measurement algorithm is presented, which combines the pulse counting method with the phase delay interpolation. The pulse counting method is used to ensure a large dynamic measuring range, and a double-edge triggering counter is designed to improve the accuracy and reduce the counting quantization error. The phase delay interpolation is used to reduce the quantization error of pulse counting for further improving the time measurement resolution. Test data show that the systexn for the measurement of the ultrasonic echo time of flight based on this algorithm and implemented on an Field Programmable Gate Army(FleA) needs a relatively short time for measurement, and has a measurement error of less than 105 ps. 展开更多
关键词 ultrasonic flow measurement time of flight phase delay interpolation
下载PDF
Effect of Measurement Time on Emission Flux of CO_2 and N_2O in Black Soil Region
13
作者 乔云发 韩晓增 赵兰坡 《Agricultural Science & Technology》 CAS 2012年第2期361-364,共4页
[Objective] The aim was to investigate and reveal effect of measurement time on emission flux of CO2 and N2O to ensure the optimum time of emission flux, in order to provide scientific reference for emission reduction... [Objective] The aim was to investigate and reveal effect of measurement time on emission flux of CO2 and N2O to ensure the optimum time of emission flux, in order to provide scientific reference for emission reduction of greenhouse gas in black soil region. [Method] Based on experiment of long-term fertilizer location in black soil region, the paper studied on daily dynamic variation of CO2 and N2O discharge in 3 key growth periods (booting stage, grain-filling stage and mature stage) to reveal differences of CO2 and N2O emission flux in different times. [Result] Daily variations of CO2 and N2O emission flux were large, from 205 mg/(m2·h) to 552 mg/(m2·h) for CO2 and from 51 h to 295 μg/(m2·h) for N2O. Trend of CO2 discharge in different growth times showed a unimodal curve, and the peak was at noon of 12:00 and the peak valley was at 3:00 am; discharge of N2O was small in day time at booting stage and large at night. Regardless of rice growth period effect on CO2 and N2O emission flux, representative time of CO2 discharge was 6:00-8:00 or 16:00-21:00; and time of N2O was 8:00-10:00 or 16:00-21:00; if CO2 and N2O emission fluxes were measured simultaneously, the optimum time was 16:00-18:00; if the measurement was started during 9:00-12:00, correction coefficients of CO2 and N2O were 0.81 and 0.90, respectively. [Conclusion] The result provided scientific reference for reduction of greenhouse gas emission in black soil region. 展开更多
关键词 CO2 N2O Black soil measurement time
下载PDF
The Fundamental Definitions in Radar Measurement Principle and Theory of Space and Time
14
作者 Lin JinFirst Academy, Ministry of Aero -Space Industry, P.R China P.O.Box 142-30-409, Beijing 100854,China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1992年第3期11-22,共12页
Fundamental definitions of distance and velocity in radar measurement principle are examined and revised from strict theoretical point of view. Synchronization scheme - for clocks in uniform, translatory relative moti... Fundamental definitions of distance and velocity in radar measurement principle are examined and revised from strict theoretical point of view. Synchronization scheme - for clocks in uniform, translatory relative motion is introduced as theoretical foundation for GPS and GLONASS type navigation and positioning technology. Traditional definitions of two-way radar measurement, based on arithmetic mean vlaue concept, turn out to be special cases of revised definitions for one-way radar measurement, based on geometric mean concept, derived from synchronization of moving clocks in accordance with the principle of relativity. The essential physical meaning of Lorentz transformation is interpreted in terms of radar measured parameters. Invariance or absoluteness of four dimensional interval turns out to be invariance or absoluteness of geometric mean time interval. The Lorentz factor turns out to be ratio of geometric mean and arithmetic mean time intervals in terms of radar measured parameters. Theoretical results are illustrated transparently by numerical examples. A crucial experiment for direct testing of the second postulate of special relativity by means of GPS of GLONASS type technology is proposed in this paper. 展开更多
关键词 Radar measurement Theory of space and time Special relativity GPS GLONASS.
下载PDF
Strong-field response time and its implications on attosecond measurement
15
作者 Chao Chen Jiayin Che +3 位作者 Xuejiao Xie Shang Wang Guoguo Xin Yanjun Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第3期16-23,共8页
To measure and control the electron motion in atoms and molecules by the strong laser field on the attosecond time scale is one of the research frontiers of atomic and molecular photophysics. It involves many new phen... To measure and control the electron motion in atoms and molecules by the strong laser field on the attosecond time scale is one of the research frontiers of atomic and molecular photophysics. It involves many new phenomena and processes and raises a series of questions of concepts, theories, and methods. Recent studies show that the Coulomb potential can cause the ionization time lag(about 100 attoseconds) between instants of the field maximum and the ionization-rate maximum. This lag can be understood as the response time of the electronic wave function to the strong-field-induced ionization event. It has a profound influence on the subsequent ultrafast dynamics of the ionized electron and can significantly change the time–frequency properties of electron trajectory(an important theoretical tool for attosecond measurement). Here, the research progress of response time and its implications on attosecond measurement are briefly introduced. 展开更多
关键词 response time strong-field ionization Coulomb effect attosecond measurement
下载PDF
Accuracy estimation of site coordinates derived from GNSS-observations by non-classical error theory of measurements
16
作者 Petro Dvulit Stepan Savchuk Iryna Sosonka 《Geodesy and Geodynamics》 CSCD 2021年第5期347-355,共9页
The velocities of tectonic plates derived from GNSS time series are regularly used as input data for geophysical models. However, as shown by numerous researches, the coordinates time series contain residual errors of... The velocities of tectonic plates derived from GNSS time series are regularly used as input data for geophysical models. However, as shown by numerous researches, the coordinates time series contain residual errors of a systematic nature, which can significantly affect the reliability of the obtained velocity estimates. This research shows that using non-classical error theory of measurement(NETM)for processing GNSS time series allows detecting the presence of weak, not removed from GNSS processing, sources of systematic errors. Based on the coordinate time series of selected permanent GNSS stations in Europe, we checked the empirical distributions of errors by the NETM on G. Jeffries’ recommendations and on the principles of the theory of hypothesis tests according to Pearson’s criterion. It is established that the obtained coordinates time series of GNSS-stations only partially confirm the hypothesis of their conformity to the normal Gaussian distribution law, and this may be the main reason for their unrepresentative classification. In the future, it is necessary to identify and take into account the causes of residual errors that distort the real distribution of the results of the GNSS time series. 展开更多
关键词 GNSS data Processing GNSS time Series Discontinuities in time series Non-classical error theory of measurements Noise analysis
下载PDF
H-infinity measurement-feedback control for discrete-time systems with a single measurement delay 被引量:1
17
作者 Mei LIU Huanshui ZHANG Guangren DUAN 《控制理论与应用(英文版)》 EI 2006年第2期121-127,共7页
H-infinity control problem for linear discrete-time systems with instantaneous and delayed measurements is studied. A necessary and sufficient condition for the existence of the H-infinity controller is derived by app... H-infinity control problem for linear discrete-time systems with instantaneous and delayed measurements is studied. A necessary and sufficient condition for the existence of the H-infinity controller is derived by applying reorganized innovation analysis approach in Krein space. The measurement-feedback controller is designed by performing two Riccati equations. The presented approach does not require the state augmentation. 展开更多
关键词 H-infinity control Delayed measurement Discrete-time systems
下载PDF
Time-resolved measurement of atomic emission enhancement by fs-ns dual-pulsed laser-induced breakdown spectroscopy 被引量:1
18
作者 颜立新 张永生 +3 位作者 郑国鑫 刘晶儒 程建平 吕敏 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第10期2271-2274,共4页
Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG ... Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG laser pulse. The ultra-short pulse serves as an igniter of the gas jet, and the subsequent ns-laser pulse significantly enhances the atomic emission. Analysis shows that the contributions to the enhancement effect are made mainly by the bremsstrahlung radiation and cascade ionization. 展开更多
关键词 time-resolved measurement atomic emission enhancement dual-pulse LIBS
下载PDF
Energy and flux measurements of laser-induced silver plasma ions by using Faraday cup
19
作者 Muhammad Usman Aslam BHATTI Shazia BASHIR +4 位作者 Asma HAYAT Khaliq MAHMOOD Rana AYUB Mubashir JAVED Muhammad Shahzad KHAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第8期188-198,共11页
Silver(Ag)plasma has been generated by employing Nd:YAG laser(532 nm,6 ns)laser irradiation.The energy and flux of ions have been evaluated by using Faraday cup(FC)using time of flight(TOF)measurements.The dual peak s... Silver(Ag)plasma has been generated by employing Nd:YAG laser(532 nm,6 ns)laser irradiation.The energy and flux of ions have been evaluated by using Faraday cup(FC)using time of flight(TOF)measurements.The dual peak signals of fast and slow Ag plasma ions have been identified.Both energy and flux of fast and slow ions tend to increase with increasing irradiance from 7 GW cm-2 to 17.9 GW cm-2 at all distances of FC from the target surface.Similarly a decreasing trend of energies and flux of ions has been observed with increasing distance of FC from the target.The maximum value of flux of the fast component is21.2×10^(10) cm^(-2),whereas for slow ions the maximum energy and flux values are 8.8 keV,8.2×10^(10) cm^(-2) respectively.For the analysis of plume expansion dynamics,the angular distribution of ion flux measurement has also been performed.The overall analysis of both spatial and angular distributions of Ag ions revealed that the maximum flux of Ag plasma ions has been observed at an optimal angle of~15°.In order to confirm the ion acceleration by ambipolar field,the self-generated electric field(SGEF)measurements have also been performed by electric probe;these SGEF measurements tend to increase by increasing laser irradiance.The maximum value of 232 V m^(-1) has been obtained at a maximum laser irradiance of 17.9 GW cm^(-2). 展开更多
关键词 laser ablation laser-induced plasma ions Faraday cup time of flight measurements self-generated electric field angular distribution
下载PDF
High sampling-rate measurement of turbulence velocity fluctuations in Mach 1.8 Laval jet using interferometric Rayleigh scattering 被引量:4
20
作者 Li Chen Fu-Rong Yang +4 位作者 Tie Su Wei-Yi Bao Bo Yan Shuang Chen Ren-Bing Li 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期341-344,共4页
Interferometric Rayleigh scattering diagnostic technique for the time-resolved measurement of flow velocity is studied. Theoretically, this systematic velocity-measured accuracy can reach up to 1.23 m/s. Measurement a... Interferometric Rayleigh scattering diagnostic technique for the time-resolved measurement of flow velocity is studied. Theoretically, this systematic velocity-measured accuracy can reach up to 1.23 m/s. Measurement accuracy is then evaluated by comparing with hot wire anemometry results. Moreover, the distributions of velocity and turbulence intensity in a supersonic free jet from a Laval nozzle with a Mach number of 1.8 are also obtained quantitatively. The sampling rate in this measurement is determined to be approximately 10 k Hz. 展开更多
关键词 Fabry–Pérot interferometer Rayleigh scattering time-resolved velocity measurement turbulence
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部