Professor T. T. Soong is one of the early pioneers in field of earthquake responsc control of structures. A new type of smart damper, which is based on an Energy Dissipating Restraint (EDR), is presented in this pap...Professor T. T. Soong is one of the early pioneers in field of earthquake responsc control of structures. A new type of smart damper, which is based on an Energy Dissipating Restraint (EDR), is presented in this paper. The EDR by Nims and Kelly, which has a triangle hysteretic loop, behaves like an active variable stiffness system (AVS) and possesses the basic characteristics of a linear viscous damper but has difficulty in capturing the output and large stroke simultaneously needed for practical applicataions in engineering structures. In order to overcome this limitation, the friction surface in the original Sumitomo EDR is divided into two parts with low and high friction coefficients in this paper. The results of finite element analysis studies show that the new type of smart friction damper enables large friction force in proportion to relative displacement between two ends of the damper and has a large allowable displacement to fit the demands of engineering applications. However, unlike the EDR by Nims and Kelly, this type of friction variable damper cannot self re-center. However, the lateral stiffness can be used to restore the structure. The nonlinear time history analysis of earthquake response for a structure equipped with the proposed friction variable dampers was carried out using the IDARC computer program. The results indicate that the proposed damper can successfully reduce the earthquake response of a structure.展开更多
This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented...This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented by replacing the conventional columns fixed to the foundations by seismic isolating ones. These columns allow horizontal displacement between the superstructure and the foundations and decouple the building from the damaging earthquake motion. As a result, the forces in the structural elements decrease and damage that may be caused to the building by the earthquake significantly decreases. However, this positive effect is achieved on account of displacements occurring in the isolating columns. These displacements become very large when the structure is subjected to a strong earthquake. In this case, impact may occur between the parts of the isolating column yielding their damage or collapse. In order to limit the displacements in the isolating columns, it is proposed to add variable friction dampers. A method for selecting the dampers' properties is proposed. It is carried out using an artificial ground motion record and optimal active control algorithm. Numerical simulation of a sevenstory structure shows that the proposed method allows efficient reduction in structural response and limits the displacements at the seismic isolating columns.展开更多
One of the challenges in civil engineering is to find an innovative means of suppressing the structural vibration due to earthquake and wind loadings. This paper presents an approach for effectively suppressing vibrat...One of the challenges in civil engineering is to find an innovative means of suppressing the structural vibration due to earthquake and wind loadings. This paper presents an approach for effectively suppressing vibrations of a structure with variable friction damper using a new Bang-Bang control input. A continuous function of story velocities is used to represent the improved control to reduce chatter, high frequency switching and avoid instability. With a genetic algorithm, the amplitudes of control and preloading friction forces individually prescribed in the controller and damper are optimized for enhancing the seismic performance of buildings. The control strategy for the friction damper is proposed for a three story building with one variable friction damper installed at the first story for seismic reduction. The numerical results indicate that a better reduction of peak response accelerations of floors can be achieved than those of the unmodified controller, and the adaptability of the control system is also improved greatly by comparison with the reduction ratios of the structural response energy excited by different earthquake intensities.展开更多
基金National Basic Research Program of China (973 Program) Under Grant No. 2007CB714200
文摘Professor T. T. Soong is one of the early pioneers in field of earthquake responsc control of structures. A new type of smart damper, which is based on an Energy Dissipating Restraint (EDR), is presented in this paper. The EDR by Nims and Kelly, which has a triangle hysteretic loop, behaves like an active variable stiffness system (AVS) and possesses the basic characteristics of a linear viscous damper but has difficulty in capturing the output and large stroke simultaneously needed for practical applicataions in engineering structures. In order to overcome this limitation, the friction surface in the original Sumitomo EDR is divided into two parts with low and high friction coefficients in this paper. The results of finite element analysis studies show that the new type of smart friction damper enables large friction force in proportion to relative displacement between two ends of the damper and has a large allowable displacement to fit the demands of engineering applications. However, unlike the EDR by Nims and Kelly, this type of friction variable damper cannot self re-center. However, the lateral stiffness can be used to restore the structure. The nonlinear time history analysis of earthquake response for a structure equipped with the proposed friction variable dampers was carried out using the IDARC computer program. The results indicate that the proposed damper can successfully reduce the earthquake response of a structure.
文摘This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented by replacing the conventional columns fixed to the foundations by seismic isolating ones. These columns allow horizontal displacement between the superstructure and the foundations and decouple the building from the damaging earthquake motion. As a result, the forces in the structural elements decrease and damage that may be caused to the building by the earthquake significantly decreases. However, this positive effect is achieved on account of displacements occurring in the isolating columns. These displacements become very large when the structure is subjected to a strong earthquake. In this case, impact may occur between the parts of the isolating column yielding their damage or collapse. In order to limit the displacements in the isolating columns, it is proposed to add variable friction dampers. A method for selecting the dampers' properties is proposed. It is carried out using an artificial ground motion record and optimal active control algorithm. Numerical simulation of a sevenstory structure shows that the proposed method allows efficient reduction in structural response and limits the displacements at the seismic isolating columns.
基金The project supported by the National Science Fund for Distinguished Young Scholars(50025823).
文摘One of the challenges in civil engineering is to find an innovative means of suppressing the structural vibration due to earthquake and wind loadings. This paper presents an approach for effectively suppressing vibrations of a structure with variable friction damper using a new Bang-Bang control input. A continuous function of story velocities is used to represent the improved control to reduce chatter, high frequency switching and avoid instability. With a genetic algorithm, the amplitudes of control and preloading friction forces individually prescribed in the controller and damper are optimized for enhancing the seismic performance of buildings. The control strategy for the friction damper is proposed for a three story building with one variable friction damper installed at the first story for seismic reduction. The numerical results indicate that a better reduction of peak response accelerations of floors can be achieved than those of the unmodified controller, and the adaptability of the control system is also improved greatly by comparison with the reduction ratios of the structural response energy excited by different earthquake intensities.