Large-scale wind turbine generator systems have strong nonlinear multivariable characteristics with many uncertain factors and disturbances. Automatic control is crucial for the efficiency and reliability of wind turb...Large-scale wind turbine generator systems have strong nonlinear multivariable characteristics with many uncertain factors and disturbances. Automatic control is crucial for the efficiency and reliability of wind turbines. On the basis of simplified and proper model of variable speed variable pitch wind turbines, the effective wind speed is estimated using extended Kaiman filter. Intelligent control schemes proposed in the paper include two loops which operate in synchronism with each other. At below-rated wind speed, the inner loop adopts adaptive fuzzy control based on variable universe for generator torque regulation to realize maximum wind energy capture. At above-rated wind speed, a controller based on least square support vector machine is proposed to adjust pitch angle and keep rated output power. The simulation shows the effectiveness of the intelligent control.展开更多
To control the position of differential cylinder closed loop without usingany throttle elements, a flew idea that two speed variable pumps are used to compensate thenon-symmetric flow of differential cylinder is carri...To control the position of differential cylinder closed loop without usingany throttle elements, a flew idea that two speed variable pumps are used to compensate thenon-symmetric flow of differential cylinder is carried out. According to the leaking property of thesystem, a speed offset principle is also proposed to eliminate the cavitation and tension caused bythe leakage and condensation of oil, which makes the system be in the same state as a valvecontrolled circuit. This principle is explained theoretically and experimentally. Further therelationship that the pressures in cylinder chambers change with load and leakage, and therelationship between biasing speed and pre-load pressures in cylinder chambers are established. Theresearch has proved that the new system has similar technique features as those of controlled withservo valves, but due to the elimination of all the throttle lose the efficiency of system can beimproved greatly.展开更多
To reduce the pitch link loads of variable speed rotors, variable tuning frequency fluid- lastic isolators are proposed. This isolator utilizes the variation of centrifugal force due to the change of rotor speed to ch...To reduce the pitch link loads of variable speed rotors, variable tuning frequency fluid- lastic isolators are proposed. This isolator utilizes the variation of centrifugal force due to the change of rotor speed to change the tuning port area ratio, which can change the tuning frequency of the isolator. A rotor model including the model of fluidlastic isolator is coupled with a fuselage model to predict the steady responses of the rotor system in forward flight. The aeroelastic analyses indicate that distinct performance improvement in pitch link load control can be achieved by the utilization of variable frequency isolators compared with the constant tuning frequency isolators. The 4/rev (per revolution) pitch link load is observed to be reduced by 87.6% compared with the increase of 56.3% by the constant frequency isolator, when the rotor speed is reduced by 16.7%. The isolation ability at different rotor speeds in different flight states is investigated. To achieve overall load reduction within the whole range of rotor speed, the strategy of the variation of tuning frequency is adjusted. The results indicate that the 4/rev pitch link load within the whole rotor speed range is decreased.展开更多
文摘Large-scale wind turbine generator systems have strong nonlinear multivariable characteristics with many uncertain factors and disturbances. Automatic control is crucial for the efficiency and reliability of wind turbines. On the basis of simplified and proper model of variable speed variable pitch wind turbines, the effective wind speed is estimated using extended Kaiman filter. Intelligent control schemes proposed in the paper include two loops which operate in synchronism with each other. At below-rated wind speed, the inner loop adopts adaptive fuzzy control based on variable universe for generator torque regulation to realize maximum wind energy capture. At above-rated wind speed, a controller based on least square support vector machine is proposed to adjust pitch angle and keep rated output power. The simulation shows the effectiveness of the intelligent control.
基金This project is supported by National Natural Science Foundation of China(No.50275102) National Foundation for Abroad Return People, China (No.2001345).
文摘To control the position of differential cylinder closed loop without usingany throttle elements, a flew idea that two speed variable pumps are used to compensate thenon-symmetric flow of differential cylinder is carried out. According to the leaking property of thesystem, a speed offset principle is also proposed to eliminate the cavitation and tension caused bythe leakage and condensation of oil, which makes the system be in the same state as a valvecontrolled circuit. This principle is explained theoretically and experimentally. Further therelationship that the pressures in cylinder chambers change with load and leakage, and therelationship between biasing speed and pre-load pressures in cylinder chambers are established. Theresearch has proved that the new system has similar technique features as those of controlled withservo valves, but due to the elimination of all the throttle lose the efficiency of system can beimproved greatly.
基金co-supported by the National Natural Science Foundation of China (Nos. 11202097 and 11472129)Aeronautical Science Foundation of China (No. 2013ZA52014)the Fundamental Research Funds for the Central Universities (No. NS2014007)
文摘To reduce the pitch link loads of variable speed rotors, variable tuning frequency fluid- lastic isolators are proposed. This isolator utilizes the variation of centrifugal force due to the change of rotor speed to change the tuning port area ratio, which can change the tuning frequency of the isolator. A rotor model including the model of fluidlastic isolator is coupled with a fuselage model to predict the steady responses of the rotor system in forward flight. The aeroelastic analyses indicate that distinct performance improvement in pitch link load control can be achieved by the utilization of variable frequency isolators compared with the constant tuning frequency isolators. The 4/rev (per revolution) pitch link load is observed to be reduced by 87.6% compared with the increase of 56.3% by the constant frequency isolator, when the rotor speed is reduced by 16.7%. The isolation ability at different rotor speeds in different flight states is investigated. To achieve overall load reduction within the whole range of rotor speed, the strategy of the variation of tuning frequency is adjusted. The results indicate that the 4/rev pitch link load within the whole rotor speed range is decreased.