Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(V...Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.展开更多
In 2006, except the basic improvement on HL-2A tokamak control system, data acquisition and processing system, a series of research activities have been developed in computer and control division. They include the con...In 2006, except the basic improvement on HL-2A tokamak control system, data acquisition and processing system, a series of research activities have been developed in computer and control division. They include the construction of the high performance computer (HPC) system, the plasma configuration real-time reconstruction with EFIT code, the immigration of plasma simulation codes, the improvement of the poloidal field control system with circulating current, the design of the new data acquiring device with higher anti-disturbing power, the new software on soft X-ray spectrum measurement providing the multi-channel Te evolution, the upgrade to the HL-2A data storage system and experimental net. On the other hand, according to the arrangement of HL-2A modification project, a series of designs such as new plasma configuration, poloidal field coils distribution and plasma shape and position control system are on the processing.展开更多
Taking the element specific-heat interpolation function into account, a one-dimensional (l-D) finite ele- ment temperature field model for the on-line control of the ultra fast cooling process was developed based on...Taking the element specific-heat interpolation function into account, a one-dimensional (l-D) finite ele- ment temperature field model for the on-line control of the ultra fast cooling process was developed based on the heat transfer theory. This 1-D model was successfully implemented in one 4 300 mm plate production line. To improve the calculation accuracy of this model, the temperature-dependent material properties inside an element were considered during the modeling process. Furthermore, in order to satisfy the real-time requirements of the on-line model, the variable bandwidth storage method and the Cholesky decomposition method were used in the programming to storage the data and carry out the numerical solution. The on-line application of the proposed model indicated that the devia- tion between the calculated cooling stop temperature and the measured one was less than ± 15 ℃.展开更多
基金the output of a research project (Title: Application of Doubly Fed Asynchronous machine in Pumped Storage Hydropower Plant in Generate Mode, supported by Islamic Azad University South Tehran Branch)
文摘Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.
文摘In 2006, except the basic improvement on HL-2A tokamak control system, data acquisition and processing system, a series of research activities have been developed in computer and control division. They include the construction of the high performance computer (HPC) system, the plasma configuration real-time reconstruction with EFIT code, the immigration of plasma simulation codes, the improvement of the poloidal field control system with circulating current, the design of the new data acquiring device with higher anti-disturbing power, the new software on soft X-ray spectrum measurement providing the multi-channel Te evolution, the upgrade to the HL-2A data storage system and experimental net. On the other hand, according to the arrangement of HL-2A modification project, a series of designs such as new plasma configuration, poloidal field coils distribution and plasma shape and position control system are on the processing.
基金Item Sponsored by National Key Technologies Research and Development Program of China(2012BAF04B01)
文摘Taking the element specific-heat interpolation function into account, a one-dimensional (l-D) finite ele- ment temperature field model for the on-line control of the ultra fast cooling process was developed based on the heat transfer theory. This 1-D model was successfully implemented in one 4 300 mm plate production line. To improve the calculation accuracy of this model, the temperature-dependent material properties inside an element were considered during the modeling process. Furthermore, in order to satisfy the real-time requirements of the on-line model, the variable bandwidth storage method and the Cholesky decomposition method were used in the programming to storage the data and carry out the numerical solution. The on-line application of the proposed model indicated that the devia- tion between the calculated cooling stop temperature and the measured one was less than ± 15 ℃.