期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
GNSS spoofing detection for single antenna receivers via CNR variation monitoring
1
作者 LIAO Maoyou LYU Xu +1 位作者 MENG Ziyang YOU Zheng 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第5期1276-1286,共11页
In this paper,a method for spoofing detection based on the variation of the signal’s carrier-to-noise ratio(CNR)is proposed.This method leverages the directionality of the antenna to induce varying gain changes in th... In this paper,a method for spoofing detection based on the variation of the signal’s carrier-to-noise ratio(CNR)is proposed.This method leverages the directionality of the antenna to induce varying gain changes in the signals across different incident directions,resulting in distinct CNR variations for each signal.A model is developed to calculate the variation value of the signal CNR based on the antenna gain pattern.This model enables the differentiation of the variation values of the CNR for authentic satellite signals and spoofing signals,thereby facilitating spoofing detection.The proposed method is capable of detecting spoofing signals with power and CNR similar to those of authentic satellite signals.The accuracy of the signal CNR variation value calculation model and the effectiveness of the spoofing detection method are verified through a series of experiments.In addition,the proposed spoofing detection method works not only for a single spoofing source but also for distributed spoofing sources. 展开更多
关键词 spoofing detection global navigation satellite system(GNSS) variation of carrier-to-noise ratio(CNR) antenna directionality
下载PDF
Rapid determination of C1^- by light-absorption ratio variation approach using Cl^--eosin Y-Ag^+ adsorptive precipitation 被引量:1
2
作者 Jing Bai Hong Yan Wang Hong Wen Gao 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第5期569-572,共4页
The adsorptive precipitation between eosin Y (EY) and AgCl colloids at pH 3.73 caused the sensitive color change of the solution. The reaction mechanism between EY and AgCl was analyzed and this reaction was used fo... The adsorptive precipitation between eosin Y (EY) and AgCl colloids at pH 3.73 caused the sensitive color change of the solution. The reaction mechanism between EY and AgCl was analyzed and this reaction was used for determination of Cl^- in trace level by the light-absorption radio variation approach. 展开更多
关键词 Determination of chloride Eosin Y Adsorptive precipitation Light-absorption ratio variation approach
下载PDF
Measures of Variability for Qualitative Variables Using the R Software
3
作者 José Moral de la Rubia 《Open Journal of Statistics》 2024年第3期259-293,共35页
Although there are many measures of variability for qualitative variables, they are little used in social research, nor are they included in statistical software. The aim of this article is to present six measures of ... Although there are many measures of variability for qualitative variables, they are little used in social research, nor are they included in statistical software. The aim of this article is to present six measures of variation for qualitative variables of simple calculation, as well as to facilitate their use by means of the R software. The measures considered are, on the one hand, Freemans variation ratio, Morals universal variation ratio, Kvalseths standard deviation from the mode, and Wilcoxs variation ratio which are most affected by proximity to a constant random variable, where the measures of variability for qualitative variables reach their minimum value of 0. On the other hand, the Gibbs-Poston index of qualitative variation and Shannons relative entropy are included, which are more affected by the proximity to a uniform distribution, where the measures of variability for qualitative variables reach their maximum value of 1. Point and interval estimation are addressed. Bootstrap by the percentile and bias-corrected and accelerated percentile methods are used to obtain confidence intervals. Two calculation situations are presented: with a sample mode and with two or more modes. The standard deviation from the mode among the six considered measures, and the universal variation ratio among the three variation ratios, are particularly recommended for use. 展开更多
关键词 variation ratio Relative Entropy Index of Qualitative variation Standard Deviation from Mode Bootstrap Confidence Interval
下载PDF
Seismic ground motion variations resulting from site conditions 被引量:1
4
作者 Silacheva N Kulbayeva U Kravchenko N 《Geodesy and Geodynamics》 2014年第2期9-15,共7页
Amplification of seismic ground motions in the territory of Almaty city is evaluated by using different methods. The pattern and probable causes of ground motion variations in different engineering-geological conditio... Amplification of seismic ground motions in the territory of Almaty city is evaluated by using different methods. The pattern and probable causes of ground motion variations in different engineering-geological conditions are characterized. An expeditious application of these techniques within a complex methodical approach for Almaty city microzonation is considered. 展开更多
关键词 ground motion variations spectral ratio methodical approach
下载PDF
Health status assessment of axial piston pump under variable speed 被引量:1
5
作者 Guo Rui Li Hucheng +3 位作者 Zhao Zhiqian Zhang Rongbing Zhao Jingyi Gao Dianrong 《High Technology Letters》 EI CAS 2020年第3期315-322,共8页
The axial piston pump usually works under variable speed conditions.It is important to evaluate the health status of the axial piston pump under the variable speed condition.Aiming at the characteristic signals obtain... The axial piston pump usually works under variable speed conditions.It is important to evaluate the health status of the axial piston pump under the variable speed condition.Aiming at the characteristic signals obtained under different wear levels of the port plate,a feature signal extraction method under variable speed conditions is proposed.Firstly,the combination of complete ensemble empirical mode decomposition with adaptive noise(CEEMDAN)energy spectrum and fast spectral kurtosis principle is used to accurately extract the intrinsic mode function(IMF)component containing the sensitive information of the degraded feature.Then,the aspect ratio analysis method of the angle domain variational mode decomposition(VMD)is used to process the feature index containing the sensitive information of the degraded feature.In order to evaluate the health status of the axial piston pump under variable speed,the vibration reliability analysis method for axial piston pump based on Weibull proportional failure rate model is proposed.The experimental results show that the proposed method can accurately evaluate the health status of the axial piston pump. 展开更多
关键词 axial piston pump variable speed condition order ratio variational mode decomposition(VMD)in angle domain health status assessment
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部